G-41 G Laser Scan Micrometer Non-contact, high-speed, high-precision measurement Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice. 50 5 8 170 74 90 70 190 70min 420 Measuring range Center of (measuring point) 70 200 120 60 15 90 ø3.1 8-M3 (Measuring position) 50 22 60 100 11 11 3 70 (Center of measuring point) Cable space 25 15.5 10.5 56 7 35 70 SERIES 544 Laser Scan Micrometer LSM-902/6900 Non-contact laser-based measuring system, mainly for outside diameter measurement. Suitable for delicate or moving workpieces. • Accuracy of ±0.5μm in the ø0.1 - ø25mm range can be achieved. It is highly suitable suited for pin gage measurement. • Narrow range accuracy of ±(0.3+0.1 D)μm for high precision measurement. • Ultra-high repeatability of ±0.05μm. • The system consists of a measuring unit (LSM-902) and a display unit (LSM-6900). Optional Accessories (Refer to page G-44 for details.) Standard calibration gage set (ø1.0, ø25.0) : 02AGD180 Workstage : 02AGD270 Adjustable workstage : 02AGD280 Digimatic code output unit (2-ch) : 02AGC840 2nd I/O analog interface unit : 02AGC880 BCD interface unit : 02AGC910 Printer & cable set (100V AC C-type plug) : 02AGD600A Printer & cable set (120V AC C-type plug) : 02AGD600B Printer & cable set (230V AC C-type plug) : 02AGD600C Printing paper TP411-28CL / 1Pack = 10pcs : 223663 Digimatic code output cable : 936937 Foot switch : 937179T SPECIFICATIONS Set Order No. 544-494 544-495* 544-496* Measuring unit Type mm mm inch/mm Applicable standards JIS IEC, FDA Measuring range 0.1 to 25mm (.004 - 1.0") Resolution 0.01 to 10μm (selectable) (.000001 - .0005") Repeatability* 1 ±0.05μm (±.000002") Accuracy* 2 (20°C) Whole range ±0.5μm (±.000020") Small range ±(0.3+0.1 D) [D:mm]* 5 ±(.000012+.001 D) [D:inch] Positional error* 3 ±0.5μm (±.000020") Measuring range* 4 ±1.5×25mm (±0.6x1.0") Scanning rate 800 scans/s Laser wavelength 650nm (Visible) Laser scanning speed 56m/s (2240"/sec) Operating environment Temperature 0 to 40°C Humidity RH 35 to 85% (no condensation) *1: Determined by the value of ±2 ( : standard deviation) when measuring ø25mm at the interval of 1.28 sec. (average 1024 times). *2: At the center of the measuring range. *3: An error due to variation in workpiece position either in the optical axis direction or in the scanning direction. *4: The area given by [optical axis direction]×[scanning direction] *5: D=Difference in diameter between the master gage and workpiece (Unit: mm) Note: To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE. Display unit Display 16-digit plus 11-digit fluorescent display, and guide message LED Segment 1 to 7 (1 to 3, transparent) or 1 to 255 edges Averaging times Arithmetic average: per 1 to 2048/ Moving average: per 32 to 2048 Judgment Selection from "target value + tolerance", "lower tolerance + upper tolerance", or "7 classes multi- limit tolerance zone". Measurement mode Standby, Single measurement, Continuous measurement Statistical analysis Maximum, Minimum, Average, Dispersion, (S.D) External dimensions 335 (W)×134 (H)×250 (D)mm Power supply 100 - 240 V AC ±10%, 50W, 50/60Hz Standard I/F RS-232C, Analog I/O Optional I/F Digimatic code output unit (2-ch), 2nd I/O analog I/F, BCD I/F Operating environment 0 to 40°C, RH 35 to 85% (no condensation) Others Nominal setting, sample setting, selection of unnecessary digits, transparent object measurement, automatic measurement in edge mode, output timer, abnormal data elimination, SHL change, group judgment, simultaneous measurement, statistical processing, mastering, buzzer function, automatic workpiece detection (dimension/position), zero-set/offset * Measuring unit dual connection, extra-fine line measurement, and some of the communication commands are not available. Unit: mm Measuring Unit External Dimensions Refer to the Laser Scan Micrometer (Catalog No. E13004) for more details. Laser safety Mitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC60825- 1 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.

Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

Embed Size (px)

Citation preview

Page 1: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-41

G

Laser Scan MicrometerNon-contact, high-speed, high-precision measurement

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

505

817

0

749070190

70min 420

Measuringrange

Center of (measuring point)70

200 12060

1590ø3.1

8-M3(Measuring position) 50

22

60100

1111 3

70 (C

ente

r of m

easu

ring

poin

t)

Cable space

25

15.5

10.5

567

35

70

SERIES 544 Laser Scan MicrometerLSM-902/6900

•Non-contact laser-based measuring system, mainly for outside diameter measurement. Suitable for delicate or moving workpieces.

•Accuracyof±0.5μmintheø0.1-ø25mmrange can be achieved. It is highly suitable suited for pin gage measurement.

•Narrowrangeaccuracyof±(0.3+0.1 D)μmfor high precision measurement.

•Ultra-highrepeatabilityof±0.05μm.•Thesystemconsistsofameasuringunit

(LSM-902)andadisplayunit(LSM-6900).

Optional Accessories (RefertopageG-44fordetails.)• Standardcalibrationgageset(ø1.0,ø25.0) : 02AGD180• Workstage : 02AGD270• Adjustableworkstage : 02AGD280• Digimaticcodeoutputunit(2-ch) : 02AGC840• 2ndI/Oanaloginterfaceunit : 02AGC880• BCD interface unit : 02AGC910• Printer&cableset(100V AC C-type plug) : 02AGD600A• Printer&cableset(120V AC C-type plug) : 02AGD600B• Printer&cableset(230V AC C-type plug) : 02AGD600C• PrintingpaperTP411-28CL/ 1Pack = 10pcs : 223663• Digimatic code output cable : 936937• Foot switch : 937179T

SPECIFICATIONSSetOrderNo. 544-494 544-495* 544-496*Measuring unitType mm mm inch/mmApplicablestandards JIS IEC,FDAMeasuring range 0.1to25mm(.004-1.0")Resolution 0.01to10μm(selectable)(.000001-.0005")Repeatability*1 ±0.05μm(±.000002")

Accuracy*2 (20°C)

Whole range ±0.5μm(±.000020")

Small range ±(0.3+0.1 D) [D:mm]*5

±(.000012+.001 D) [D:inch]Positional error*3 ±0.5μm(±.000020")Measuring range*4 ±1.5×25mm(±0.6x1.0")Scanning rate 800scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 56m/s(2240"/sec)Operatingenvironment

Temperature 0to40°CHumidity RH35to85%(nocondensation)

*1:Determinedbythevalueof±2 ( : standard deviation) whenmeasuringø25mmattheintervalof1.28sec.(average1024times).

*2:Atthecenterofthemeasuringrange.*3:Anerrorduetovariationinworkpiecepositioneitherinthe

opticalaxisdirectionorinthescanningdirection.*4:Theareagivenby[opticalaxisdirection]×[scanningdirection]*5: D=Difference in diameter between the master gage and

workpiece(Unit:mm)Note:TodenoteyourACpowercableaddthefollowingsuffixes

totheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredfor PSE.

Display unit

Display 16-digitplus11-digitfluorescentdisplay,andguidemessageLED

Segment 1to7(1to3,transparent)or1to255edgesAveragingtimes

Arithmeticaverage:per1to2048/Movingaverage:per32to2048

JudgmentSelectionfrom"targetvalue+tolerance","lowertolerance+uppertolerance",or"7classesmulti-limittolerancezone".

Measurement mode

Standby, Single measurement, Continuous measurement

Statistical analysis Maximum,Minimum,Average,Dispersion, (S.D)

Externaldimensions 335(W)×134(H)×250(D)mm

Power supply 100-240VAC±10%,50W,50/60HzStandardI/F RS-232C,AnalogI/O

OptionalI/F Digimaticcodeoutputunit(2-ch),2ndI/OanalogI/F,BCDI/F

Operatingenvironment 0to40°C,RH35to85%(nocondensation)

Others

Nominal setting, sample setting, selection of unnecessary digits,transparentobjectmeasurement,automaticmeasurement in edge mode, output timer, abnormal dataelimination,SHLchange,groupjudgment,simultaneous measurement, statistical processing, mastering, buzzer function, automatic workpiece detection(dimension/position),zero-set/offset*Measuringunitdualconnection,extra-finelinemeasurement,and some of the communication commands are not available.

Unit:mmMeasuring Unit External Dimensions

RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.

Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.

Page 2: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-42

G

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

Cable space

Measuring range

(Measuring position)

M3, depth 6 (×4)ø3.1, depth 6

55126181

2

1

34324610370min

2532

.5

8440

15.5

10.5 17.5

1111

Working distance

40

SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-500S

•Capableofmeasuringdownto5μmoutsidediameter*1.

•Providesultra-highaccuracyof±0.3μmovertheentiremeasuringrange(5μmto2mm).

•Ultra-highspeedmeasurementof3200scan/sec.

Suitable for high speed lines or in applications subjecttovibration.

Optional Accessories• Multifunctional display unit, LSM-6200:

• Easy-to-operate display unit, LSM-5200:

•Standardcalibrationgageset(ø0.1,ø2.0) : 02AGD110• Guide pulley : 02AGD200•Airblower : 02AGD220

Unit:mmDIMENSIONS

RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.

OrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m

OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual

OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing

suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."

SPECIFICATIONSOrderNo. 544-531 544-532Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 0.005to2mm*1

Resolution 0.01to10μm(selectable)Repeatability*2 ±0.03μmAccuracy(20°C)*3 ±0.3μmPositional error*4 ±0.4μmMeasuring range*5 1×2mm(0.005to2mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 76m/sOperatingenvironment

Temperature 0to40°CHumidity RH35to85%(nocondensation)

ProtectionLevel IP64*6

*1:Themeasuringrangeforthetransparentobjectwillbe0.05mmto2mm.PleaseconsultyourlocalMitutoyoofficeforobjectssmallerthan0.05mm.

Themeasuringrangewillbe0.1mmto2mminthe1to255edgemeasurementmodeorwhenactivatingtheautomaticworkpiece detection.

IfusingtheoptionaldualconnectionunitforLSM-6200,themeasuringrangewillbe0.05mmto2mm.*2:Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø2mmattheintervalof0.32sec.(average1024times).*3:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*4: Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,theunitmaymalfunction.Note:Whenusingextra-finelinemeasurementfunction(FINE),guidemessagesforsettingthefollowingwillnotbedisplayed:dual-

measurement,segmentdesignation,automaticworkpiecedetection,andgroupjudgment.

Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.

Page 3: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-43

G

Laser Scan MicrometerNon-contact, high-speed, high-precision measurement

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

8-M3

42 6453

10.5

15.5

2250

2084

104

57.5

23070min123 3968

34 34*7

10

48 8

18.5

4040

110 40.5 38.5 30

9.5

9.5

14.5

9.5

150

6

40 40

157 73

ø3.1 hole, depth 6(Measuring position)

Signal cable

Cable space

Relay cable

Emission Unit Base

Max. 100

Measuring range

Reception Unit

Measuring position

M4, depth 8 (×3) M4, depth 8 (×3)

To Reception Unit(Cable length 0.6m)

ø3.1 hole, depth 6

ø3.1 hole, depth 6

Dimension when disconnected (bottom view)

<Mass>Emission Unit: 0.7kgReception Unit: 0.4kgBase: 0.3kgSignal cable (5m): 0.5kg*7: Extendable up to 66mm.

SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-501S

•Providesultra-highaccuracyof±0.5μmovertheentiremeasuringrange(0.05to10mm).

•Narrowrangeaccuracyof±(0.3+0.1 D)μmforhigh precision measurement.

•Ultra-highspeedmeasurementof3200scan/sec.

Suitable for high speed lines or in applications subjecttovibration.

Optional Accessories• Multifunctional display unit, LSM-6200:

• Easy-to-operate display unit, LSM-5200:

•Standardcalibrationgageset(ø0.1,ø10.0) : 02AGD120• Wire guiding pulley : 02AGD210•Adjustableworkstage : 02AGD400•Airblower : 02AGD230• Workstage : 02AGD270•Extensionsignalcable

SPECIFICATIONSOrderNo. 544-533 544-534Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 0.05to10mmResolution 0.01to10μm(selectable)Repeatability*1 ±0.04μm

Accuracy*2(20°C) Whole range ±0.5μmSmall range ±(0.3+0.1 D)μm*3

Positional error*4 ±0.5μmMeasuring range*5 2×10mm(ø0.05toø0.1mm)4×10mm(ø0.1toø10mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 113m/sOperatingenvironment

Temperature 0to40°CHumidity RH35to85%(nocondensation)

ProtectionLevel IP64*6

*1: Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø10mmattheintervalof0.32sec.(average1024times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4: Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Theprotectionlevelprovidedfortheinterior.Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,

the unit may malfunction.

Unit:mmDIMENSIONS

RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.

OrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m

•ExtensionrelaycableOrderNo. Cable length02AGC150A 1m

Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.

OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual

OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing

suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."

Page 4: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-44

G

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

ø3.1

8-M3

805.

5

10525054.584.5

42 42

70 min

170 5580 50*7

88

482594857202

6

18.5

5022

10.5

15.5

9.5

9.5

14.5

9.5

415790

12 11090

20

10

30

355

46

53 6842

95.5 65.5

150

57.5

130

(Measuring position)

Signal cable

Cable space

Relay cable

Emission Unit

Max. 350

Measuring range

Measuring range

Reception Unit

Base

M4, depth 8, ø3.3 through hole (×3)For mounting side plate (same in the back)

M4, depth 8, ø3.3 through hole (×2)For mounting side plate (same in the back)

To Reception Unit(Cable length 1.4m)

ø3.1, depth 6 (Reference hole)

M4, depth 8 (×3)For mounting base

ø3.1, depth 6 (Reference hole)

M4, depth 8 (×3)For mounting base

Dimension when disconnected (bottom view)

<Mass>Emission Unit: 1.1kgReception Unit: 0.6kgBase: 0.5kgSignal cable (5m): 0.5kg*7: Extendable up to 270mm

SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-503S

•Ensures±1.0μmaccuracyovertheentiremeasuringrange(0.3to30mm).

•Narrowrangeaccuracyof±(0.6+0.1 D)μmforhigh precision measurement.

•Ultra-highspeedmeasurementof3200scan/sec.

Suitable for high speed lines or in applications subjecttovibration.

Optional Accessories• Multifunctional display unit, LSM-6200:

• Easy-to-operate display unit, LSM-5200:

•Standardcalibrationgageset(ø0.1,ø30.0) : 02AGD130•Adjustableworkstage : 02AGD490•Airblower : 02AGD240• Workstage : 02AGD270•Extensionsignalcable

Unit:mmDIMENSIONS

RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.

OrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m02AGN780D 20m

•ExtensionrelaycableOrderNo. Cable length02AGC150A 1m02AGC150B 3m02AGC150C 5m

SPECIFICATIONSOrderNo. 544-535 544-536Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 0.3to30mmResolution 0.02to100μm(selectable)Repeatability*1 ±0.11μmAccuracy*2

(20°C)Whole range ±1.0μmSmall range ±(0.6+0.1 D)μm*3

Positional error*4 ±1.5μmMeasuring range*5 10×30mm(0.3to30mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 226m/sOperatingenvironment

Temperature 0to40°CHumidity RH35to85%(nocondensation)

ProtectionLevel IP64*6

*1: Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø30mmattheintervalof0.32sec.(average1024times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4: Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Theprotectionlevelprovidedfortheinterior.Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,

the unit may malfunction.

Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.

OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual

OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing

suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."

Page 5: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-45

G

Laser Scan MicrometerNon-contact, high-speed, high-precision measurement

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

12-M3

ø3.1

15.5

10.5

110*716388

192348

66

20

60

42

4218

.5

90 360 90

2250

100

58 70

7

258 102

540

185 82

70min

2011

013

0

12

115.5 71

797

168.587 87

42

14.5

9.5

162 174.5 121 63

9.5

9.5

273

(Measuring position)

Signal cable

Cable space

Relay cable

Emission Unit

Max. 700

Measuring range

Measuring range

Reception Unit

Base

M5, depth 10, ø4.2 through hole (×3)For mounting side plate (same in the back)

M5, depth 10, ø4.2 through hole (×2)For mounting side plate (same in the back)

To Reception Unit(Cable length 1.4m)

ø3.1, depth 6 (Reference hole)

M5, depth 10 (×3)For mounting base

ø3.1, depth 6 (Reference hole)

M5, depth 10 (×3)For mounting base

Dimension when disconnected (bottom view)

<Mass>Emission Unit: 1.4kgReception Unit: 0.8kgBase: 0.8kgSignal cable (5m): 0.5kg*7: Extendable up to 537mm

SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-506S

•Ensures±3μmaccuracyovertheentiremeasuringrange(1to60mm).

•Narrowrangeaccuracyof±(1.5+0.5 D)μminfor high precision measurement.

•Ultra-highspeedmeasurementof3200scan/sec. Suitable for high speed lines or in applications

subjecttovibration.

SPECIFICATIONSOrderNo. 544-537 544-538Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 1to60mmResolution 0.05to100μm(selectable)Repeatability*1 ±0.36μmAccuracy*2

(20°C)Whole range ±3μmSmall range ±(1.5+0.5 D)μm*3

Positional error*4 ±4μmMeasuring range*5 20×60mm(1to60mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 452m/sOperatingenvironment

Temperature 0to40°CHumidity RH35to85%(nocondensation)

ProtectionLevel IP64*6

*1: Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø60mmattheintervalof0.32sec.(average1024times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4: Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Theprotectionlevelprovidedfortheinterior.Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,

the unit may malfunction.

Unit:mmDIMENSIONS

RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.

Optional Accessories• Multifunctional display unit, LSM-6200:

• Easy-to-operate display unit, LSM-5200:

•Standardcalibrationgageset(ø1.0,ø60.0) : 02AGD140•Adjustableworkstage : 02AGD520•Airblower : 02AGD250•ExtensionsignalcableOrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m02AGN780D 20m

•ExtensionrelaycableOrderNo. Cable length02AGC150A 1m02AGC150B 3m02AGC150C 5m

Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.

OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual

OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing

suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."

Page 6: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-46

G

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

8-M4

ø3.1

312 88

48

7

48

146

9

146

9

200100

521379696 263

8068

18.5

4816

230

192

84

99131*7190

700107321272

238462

70 min

19

819

8

85144256192

198

150400150

120

30

(Measuring position)

Signal cable

Cable space

Relay cable

Emission Unit

Max. 700

Measuring range

Measuring range

Reception Unit

Base

M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)

M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)

M6, depth 12 (×3)For mounting base

M6, depth 12 (×3)For mounting base

To Reception Unit(Cable length 1.4m)

ø3.1, depth 6 (Reference hole)

ø3.1, depth 6 (Reference hole)

Dimension when disconnected (bottom view)

<Mass>Emission Unit: 3.0kgReception Unit: 1.2kgBase: 1.8kgSignal cable (5m): 0.5kg*7: Extendable up to 510mm

SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-512S

•Ensures±6μmaccuracyovertheentiremeasuringrange(1to120mm).

•Narrowrangeaccuracyof±(4.0+0.5 D)μminfor high precision measurement.

•Ultra-highspeedmeasurementof3200scan/sec. Suitable for high speed lines or in applications

subjecttovibration.

Unit:mmDIMENSIONS

RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.

Optional Accessories• Multifunctional display unit, LSM-6200:

• Easy-to-operate display unit, LSM-5200:

•Standardcalibrationgageset(ø20.0,ø120.0) : 02AGD150•Airblower : 02AGD260•ExtensionsignalcableOrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m02AGN780D 20m

•ExtensionrelaycableOrderNo. Cable length02AGC150A 1m02AGC150B 3m02AGC150C 5m

SPECIFICATIONSOrderNo. 544-539 544-540Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 1to120mmResolution 0.1to100μm(selectable)Repeatability*1 ±0.85μmAccuracy*2 (20°C)

Whole range ±6μmSmall range ±(4.0+0.5 D)μm*3

Positional error*4 ±8μmMeasuring range*5 30×120mm(1to120mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 904m/sOperatingenvironment

Temperature 0to40°CHumidity RH35to85%(nocondensation)

ProtectionLevel IP64*6

*1: Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø120mmattheintervalof0.32sec.(average1024times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4: Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Theprotectionlevelprovidedfortheinterior.Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,

the unit may malfunction.

Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.

OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual

OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing

suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."

Page 7: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-47

G

Laser Scan MicrometerNon-contact, high-speed, high-precision measurement

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

ø3.1 (Measuring position)8-M4

84110 10

841

9 9

378

170 110600350 250

9

200100

120

100

7420

.5

880320 160400

8.7200 200

8.7

224

2524

9

206 87.5360520

306107100

40

200400 13 13688218

160

208

208

Min. 70

Cable space

Measuring range

M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)

M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)

M6, depth 12 (×3)For mounting base

M6, depth 12 (×3)For mounting base

Measuring position ø3.1 hole, depth 6(Reference hole)

Note1: Distance between emission unit and reception unit: 400mm to 800mm

Note1

SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-516S

•Ensures±7μmaccuracyovertheentiremeasuringrange(1to160mm).

•Narrowrangeaccuracyof±(4.0+2.0 D)μmforhigh precision measurement.

•Ultra-highspeedmeasurementof3200scan/sec.

Suitable for high speed lines or in applications subjecttovibration.

SPECIFICATIONSOrderNo. 544-541 544-542Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 1to160mmResolution 0.1to100μm(selectable)Repeatability*1 ±1.4μmAccuracy*2 (20°C)

Whole range ±7μmSmall range ±(4.0+2.0 D)μm*3

Positional error*4 ±8μmMeasuring range*5 40×160mm(1to160mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 1206m/sOperatingenvironment

Temperature 0to40°CHumidity RH35to85%(nocondensation)

ProtectionLevel IP64*6

*1: Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø160mmattheintervalof0.32sec.(average1024times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4: Anerroroftheoutsidediameterduetovariationincylinderpositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Theprotectionlevelprovidedfortheinterior.Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,

the unit may malfunction.

RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.

Optional Accessories• Multifunctional display unit, LSM-6200:

• Easy-to-operate display unit, LSM-5200:

•Standardcalibrationgageset(ø20,ø160) : 02AGM300•ExtensionsignalcableOrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m02AGN780D 20m

•ExtensionrelaycableOrderNo. Cable length02AGC150A 1m02AGC150B 3m02AGC150C 5m

Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.

Unit:mmDIMENSIONS

OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual

OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing

suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."

Page 8: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-48

G

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

ø3.1 (Measuring position)

12-M3

Measuring range

80Ca

ble

spac

e18

0

11

25

60

98

1005022

647

60

120

1011 882365

52.540

382 85180

528

202

11

10.5

15.5

1010

0

10150

83 97

100 100

172 13.5

SERIES 544 Laser Scan Micrometer (Display Unit Integrated Model)LSM-9506

•Highaccuracyof±2.5μm,integrateddisplayunitwithmanyfunctionsequivalenttothemulti-functiondisplay unit.

Optional Accessories• Standardcalibrationgageset(ø1,ø60) : 02AGD170

Unit:mmDIMENSIONS

RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.

SPECIFICATIONSOrderNo. 544-115* 544-116**Type mm inch/mmMeasuring range 0.5to60mm .02”-2.36”/0.5-60mmResolution 0.05to100μm(selectable) .000002”-.005/0.00005-0.1mmRepeatability*1 ±0.6μm(±.00003")Accuracy*2(20°C) ±2.5μm(±.0001")Positional error*3

(opticalaxis/scanningdirection)±2.5μm(±.0001")

L:DisplacementbetweenworkpiececenterandopticalaxiscenterMeasuring range*4 ±5x60mm(±.2x2.36")Scanning rate 1600scans/sLaserwavelength 650nm(Visible)*5

Laserscanningspeed 226m/s(8900"/s)Display unit 16-digitdotmatrix(uppercolumn)+7segment11-digit(lowercolumn),guidanceLEDsStandard interface RS-232C,Digimaticcodeoutputunit(1ch)Optionalinterface NoPower supply AC100V-240V±10%,40VA,50/60HzOperatingenvironment 0to40°C,RH35to85%(nocondensation)*1:Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø10mmattheintervalof0.32sec. (average512times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4:Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanning

direction.*5:FDAClassII(544-116-1A)/IECClass2(Allmodelsexcept544-116-1A)semiconductorlaserforscanning(Maximumpower:1.0mW)*TodenoteyourACpowercableaddthefollowingsuffixestotheorderNo.:DforCEE,DCforCCC,EforBS,FforSAA,KforKC,

CandNosuffixarerequiredforPSE.**TodenoteyourACpowercableaddthefollowingsuffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,Kfor

KC,CandNosuffixarerequiredforPSE.

Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.

Page 9: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-49

G

Laser Scan MicrometerNon-contact, high-speed, high-precision measurement

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

Cabl

e sp

ace

キーロック CAL オフセット 統計処理 同時測定

BUSYRUN+NGGO-NG

LD2 ON

LD1 ON 0 +/-

1 2 3

654

7 8 9

L.CAL

H.CAL

読込み

シフト 測定 設定

C

合否判定

基準値

入力単位

葦字

統計処理

PROG.

SW.FOOT

I/O ANALOG RS-232C REMOTE INTERLOCK

SCAN SIG.-1

TRANSMITTER-1

ID ROM 1

A1A6

B1B6DI

335

80

125

1313

428

1.4

121

13.5

250

12°

•2-axisdisplayunitenabless2itemsbedisplayedsimultaneously.

•Capableofstatisticalanalysissuchas:average,maximumvalue,minimumvalue,range(max.-min.).

•Segmentmeasurement(7points)oredgemeasurement(1to255edge)canbeselected.

•Afunctiontoeliminateabnormalvaluesisstandard.

•100tolerancevalues,presetvalues,orsettingscan be stored.

SERIES 544 Laser Scan Micrometer (Multifunctional Display Unit)LSM-6200

RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.

SPECIFICATIONSOrderNo. 544-071* 544-072*Type mm inch/mmDisplay 16-digitplus11-digitfluorescentdisplay,andguidemessageLEDSegment 1to7(1to3,transparent)or1to255edges*1

Averagingtimes Arithmeticaverage:per2to2048/Movingaverage:per32to2048(Arithmeticaverageisper16to2048when using 544-531, 544-532)

Judgment Selectionfrom"targetvalue+tolerance","lowertolerance+uppertolerance",or"7classesmulti-limittolerancezone".

Measurement mode Standby, Single measurement, Continuous measurementStatistical analysis Maximum,Minimum,Average,Dispersion, (S.D)Size 335(W)×134(H)×250(D)mmPower supply 100-240VAC±10%,40VA,50/60HzStandardI/F RS-232C,AnalogI/OOptionalI/F Digimaticcodeoutputunit(2-ch),2ndI/OanalogI/F,BCDI/FOperatingenvironment 0to+40°C,RH35to85%(nocondensation)

Others

Nominalsetting,samplesetting,selectionofunnecessarydigits,transparentobjectmeasurement*2, measurement of odd fluted parts, automatic measurement in edge mode, output timer, abnormal data

elimination,SHLchange,groupjudgment,simultaneousmeasurement,statisticalprocessing,mastering,buzzerfunction,automaticworkpiecedetection(dimension/position)*1,zero-set/offset,dualmeasurement(optional)

*1:Themeasuringrangewillbe0.1mmto2mminthe1to255edgemeasurementmodeorwhenactivatingtheautomaticworkpiece detection with 544-531, 544-532.

Each function has its combination limit.*2:Themeasuringrangeis50μmto2mmwhenusing544-531, 544-532. For smaller range, contact your local Mitutoyo sales office.*TodenoteyourACpowercableaddthefollowingsuffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,Ffor

SAA,KforKC,CandNosuffixarerequiredforPSE.** Cannot be connected to 544-495, 544-496.** Previous models such as 544-451 cannot be connected.

Unit:mmDIMENSIONS

Page 10: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-50

G

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

SERIES 544 Laser Scan Micrometer (Panel-mount Type Display Unit)LSM-5200

•Acompactcontrollerwhichcouldbeusedformulti-unit system configurations.

•CapableofsimpleconnectiontoaPCviaUSB.

•APanel-mounttypedisplayunitdesignedfortheLSM-Sseries.

•AnalogI/OandRS-232Cisstandard.•Measurement of odd fluted parts, and

simultaneousmeasurement/2-programfunctionareequipped.

138 0+1

72

144

140.4

68

138 (Aluminum case)

197.1 (20.5)

Front view

Rear view

68+0

.7 0

Dimensions of panel mounting slot (DIN 43 700-144×76)Panel thickness: 1.6mm to 6mmMass: 1.4kg

Support for mounting plate

Bottom view

Panel thickness: 1.6mm to 6mm

*240

.3 +

(t-

0.6)

(4.4

)

(Alum

inum

case

)

Side view

RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.

Unit:mmDIMENSIONS

SPECIFICATIONSOrderNo. 544-047Display 9digitsplus8digitsLED,guidemessageLEDSegment 1to7(1to3,transparent)or1to255edges*1

Averagingmethod Arithmeticaverage:from4to2048;Movingaverage:from32to2048(Arithmeticaverageisfrom16to2048whenusingLSM-500S.)

Judgment Selectingfrom"targetvalue±tolerancevalue"or"lowerlimit/upperlimit".Measurement mode Standby, Single measurement, Continuous measurementStatistical analysis CalculationresultisoutputviaUSBorRS-232C.Externaldimensions 144(W)×72(H)×197.1(D)mmPower supply*3 24VDC±10%,1.3AormoreStandardI/F USB2.0,RS-232C,I/OanalogOperatingenvironment 0to40°C,RH35to85%(nocondensation)

Preservation environments −20to70°C,RH35to85%(nocondensation)

Others

Measurement of odd fluted parts, simultaneous measurement, nominal setting, sample setting, selection of unnecessarydigits,transparentobjectmeasurement*2

Automaticworkpiecedetection(dimension/positiondetected)*1, abnormal data elimination, mastering, statistical processing(whenusingUSB,RS-232C),outputtimer,automaticmeasurementinedgemode,presetting

Note that every function is limited in its combination possibilities. See the user manual for details.Mass 1.4 kg

*1:Themeasuringrangewillbe0.1mmto2mminthe1to255edgemeasurementmodeorwhenactivatingtheautomaticworkpiece detection with 544-531, 544-532.

Each function has its combination limit.*2:Themeasuringrangeis50μmto2mmwhenusing544-531, 544-532. For smaller ranges, contact your local Mitutoyo sales office.*3:DC24Vexternalpowersupply(commercialitem)isrequiredseparately.Note 1: Cannot be connected to 544-495, 544-496.Note2:Previousmodelssuchas544-451 cannot be connected.Note3:ForUSBcommunicationwithaPC,adedicateddevicedriverisrequired.Fordetails,contactyourlocalMitutoyosalesoffice.

Page 11: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-51

G

Laser Scan MicrometerNon-contact, high-speed, high-precision measurement

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefi t of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specifi cation without notice.

Sample Screen Measurement ExamplesPrinter roll multi-point simultaneous measurement

LSMPAK•SoftwarecanimportmeasurementdatafrommultipleLSM-5200displayunitstoaPCallowinga

variety of measuring systems to be constructed.•Capableofprocessingamaximumof10channelsofmeasurementdata(USB-HUBconnection).•CapableofCalculation between channels, statistical analysis, fi le output of calculation results.•Variousdisplayfunctionssuchascounterdisplay,graphdisplay,andcalculationresultareequipped. *RefertopageG-50forspecificationsofLSM-5200.

SERIES 544 Laser Scan Micrometer (Display Unit)Optional Accessories

544-047

544-531, 532

LSMPAK

Commercially available products, such as USB hubs and cables, areavailable for connecting to the display unit.

SPECIFICATIONSOrderNo. 02NGA002(English) 02NGA003(Korean) 02NGA004(German)

Applicablemodels Display unit: 544-047(Ver.1.004Aorlater)Measuring unit: 544-531, 532 series

Display function Max.12windows(counter,meter,chart,overalljudgment)

Setup function Presetting,dataoutput,samplemeasurement,resolutionselect,judgmentsetting,measurementofodd number fluted parts, simultaneous measurement *Each function has its combination limit.

Measurement function Single, continuous measurement, single automatic repetitionCalculation function Arithmeticoperation,maximum,minimum,range,average,total(anycombinationavailable)GO/NGjudgment 3-step(–NG,GO,+NG)Interface USB2.0(Hi-Speedcommunicationrecommended)Maximumconnection 10units

Operatingenvironment (PC)

OS WindowsXP,7(32-bit)CPU Pentium4,2GHzorbetterrecommendedMemory 1GB or moreHDD free space 500MBormoreDisplay 1024×768dot,TrueColor(32-bit)ormorerecommended

Page 12: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-52

G

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

SERIES 544 Laser Scan Micrometer (Measuring Unit)Optional Accessories

•Standard cylinder gage set suitable for calibrationofLaserScanMicrometers.

•Nominalgagediameters(1to160mm)areasgiven in Specifications.

Standard calibration gage set

Installationexample(LSM-902)

•Easy set-up and height adjustmentenableshigh-precisionmeasurement.

Workstage

•Pin gage or plug gage•Rollerofcopyingmachine

Measurement Examples

•Vertical/horizontalslidemechanismenableseasymeasurement of various workpiece diameters.

•Bestsuitedforqualityassuranceofhighprecision pin gages.

Adjustable workstage

SPECIFICATIONSFor calibrating models 544-495, 544-496 544-531, 544-532 544-533, 544-534 544-535, 545-536 544-537, 544-538 544-539, 544-540 544-541, 544-542 544-115, 544-116Set No. 02AGD180 02AGD110 02AGD120 02AGD130 02AGD140 02AGD150 02AGM300 02AGD170

Configuration(OrderNo.)

Stand 02AGD181 02AGD111 02AGD121 02AGD131 02AGD141 02AGD151 02AGM320 02AGD171

Gages ø1:02AGD920ø25:02AGD963

ø0.1:958200ø2:958202

ø0.1:958200ø10:229317

ø1:02AGD920ø30:02AGD961

ø1:02AGD920ø60:02AGD962

ø20:229730ø120:234072

ø20:229730ø160:02AGM303

ø1:02AGD920ø60:02AGD962

Carrying case 02AGD190 958203 958203 02AGD980 02AGD980 02AGD990 02AGM310 02AGD970

SPECIFICATIONS

Model544-533, 544-534544-535, 544-536544-495, 544-496

OrderNo. 02AGD270

Basic configurationBasic set OrderNo. Model StandardAccessories Measuringrange(mm) Horizontalstroke(mm) Verticalstroke(mm)

(1)Mainunit(2)V-block(3)Stop

02AGD280 544-495, 544-496V-block(02AGD420),2pcsStopper(02AGD430),1pc

0.1-25 130 4702AGD400 544-533, 544-534 0.05-10 130 3202AGD490 544-535, 544-536 0.3-30 200 3502AGD520 544-537, 544-538 V-blockA(02AGD550),2pcs

V-blockB(02AGD560),1pcV-blockC(02AGD570),1pc

1-60 300 4502AGD370 544-115, 544-116 0.5-60 200 4502AGD680 0.5-60 300 45

* The stop is not included in the basic set for 544-537, 544-538, 544-115, 544-116. •Optionalpartfortheadjustableworkstage,suchascentersupport,adjustableV-block(up/down)etc.,areavailable.

Aninspectioncertificateissuppliedasstandard.RefertopageXfordetails.

Page 13: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-53

G

Laser Scan MicrometerNon-contact, high-speed, high-precision measurement

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

SERIES 544 Laser Scan Micrometer (Measuring Unit)Optional Accessories

•Usedforsupportingmeasurementofoutsidediameter of fine wirelike materials such as magnetic wire or fiber.

Guide pulley

•Airblowsfromtheairoutletinstalledonthelasersection to clear dust adhering to the laser window.

Air shield

•Extensionsignalcablesarenecessarywhenthemeasuringunitanddisplayunitareseparatedinoperation;Extensionrelay cables are necessary when the optical section is separated in operation.

Extension signal cable / Extension relay cable

SPECIFICATIONSModel 544-531, 544-532 544-533, 544-534OrderNo. 02AGD200 02AGD210Each measurement range is as follows:544-531, 544-532:ø5μmtoø1.6mm544-533, 544-534:ø50μmtoø2mm

For calibration, the calibration gage set for 544-531, 544-532(02AGD110)isrequired.

SPECIFICATIONSAirsupplyunit Airshield Applicablemodels

957608

02AGD220 544-531, 544-53202AGD230 544-533, 544-53402AGD240 544-535, 544-53602AGD250 544-537, 544-53802AGD260 544-539, 544-540

*Airshieldissuppliedwith5mairtube(OutsideDiameter:6mm).

Extension signal cable

Relay cable, 1.4m(0.6m for 544-533, 544-534) Not equipped with 544-531, 544-532 (and 544-495, 544-496 )

Extension relay cable

Signal cable (5m) No.02AGN770A

Display unit

Emission Unit

Reception Unit

SPECIFICATIONSExtension signal cable Extension relay cableOrderNo. Cable length OrderNo. Cable length02AGN780A 5m 02AGC150A 1m02AGN780B 10m 02AGC150B 3m02AGN780C 15m 02AGC150C 5m02AGN780D 20m* For 544-531, 544-532 and 544-533, 544-534theallowablemaximumlengthforsignalcableis20m;relaycableis2m.* For 544-535, 544-536, 544-537, 544-538, 544-539, 544-540 and 544-541, 544-542theallowablemaximumlengthfor

signalcableis30m;relaycableis5m.*Themaximumextensionlengthofthesignalcableandrelaycableis32mintotal.* Cannot be used with 544-495, 544-496.

Page 14: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-54

G

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

•Measurementdatacanbeprinted.

SERIES 544 Laser Scan Micrometer (Display Unit)Optional Accessories

Thermal printer DPU-414

•OutputsmeasurementdatainBCDoutput(7-digit)orHEXoutput.

•Datalogiccanbeswitched.•IsolatedI/Ocircuitry•Availablefor544-071, 544-072, 544-495,

544-496.

Interface for LSM6200, 6900Optional Accessories

BCD Interface

Foot switch

SPECIFICATIONS

OrderNo.

02AGD600A02AGD600B02AGD600C02AGD600D

Printing method ThermaldotmatrixPrinting capacity 40Columns(Normal)Character configuration 9×8dotmatrix

Printing direction BidirectionalInterface RS-232CPower supply AC100-240V50/60Hz(ACadapter)

StandardAccessories Printercable2m(02AGD620A), Printer paper1roll,ACadapter

Printerpaper(optional) OrderNo.223663(10-rollset)

•937179T•ForLSMOrder544-071, 544-072, 544-495,

544-496, 544-115, 544-116

SPECIFICATIONSOrderNo. 02AGC910StandardAccessories Connector(DDK)57-30360(214188)

Page 15: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-55

G

Laser Scan MicrometerNon-contact, high-speed, high-precision measurement

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

XY Measurement

(X–Y): flatness(X+Y)/2:average*XYrequires10mm-interval.

Parallel Measurement

SERIES 544 Laser Scan Micrometer (Display Unit)Optional Accessories

•2-channelDigimaticcodeoutput•Insimultaneousmeasurement,measurement

data are output as follows:ProgramNo.0toNo.4inOUTPUT-1ProgramNo.5toNo.9inOUTPUT-2(10

programs operated)•10pinMILtypeconnector.•Outputcableisnotsupplied.Connectingcable(optional)1m(936937)•Availablefor544-071, 544-072, 544-495,

544-496.*Outputis6digitsofmeasurementdata.*Displaying6thand7thdigitafterthedecimalpointisnot

supported.

Digimatic code output unit

•Enables second unit connection to the 544-071, 544-072.(bothunitsmustbethesamemodel)

* Cannot be used for 544-495, 544-496.•Depending on the layout of the two measuring units,

large-diameter measurement, XY measurement, and parallel measurement are possible.

•Bothofthemeasuringunitsanddisplayunitscan be simultaneously operated.

120±10

47.8

200±10

Dual connection unit

•I/O,analogoutput.•Simultaneous measurement is supported by two

pairsofGO/NGjudgmentoutputs.•Availablefor544-071, 544-072, 544-495, 544-

496.

2nd I/O analog I/F

X Y

•BothBCD(02AGC910)and2ndI/OanalogI/F(02AGC880) can be mounted on 544-071, 544-072, 544-495, 544-496 using this cable.

* If using this cable, the dual connection unit (02AGP150) cannot be used.

Cable for BCD and 2nd I/O simultaneous mount

SPECIFICATIONSOrderNo. 02AGC840

SPECIFICATIONSOrderNo. 02AGP150

SPECIFICATIONSOrderNo. 02AGC880StandardAccessories Connector(DDK)57-30360(214188)

SPECIFICATIONSOrderNo. 02AGE060

Unit:mmDIMENSIONS

Page 16: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-56

G

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

G-56

G

■ CompatibilityYourLaserScanMicrometerhasbeenadjustedtogetherwiththeIDUnit,whichissuppliedwiththemeasuringunit.TheIDUnit,whichhasthesamecode number and the same serial number as the measuring unit, must be installedinthedisplayunit.ThismeansthatiftheIDUnitisreplacedthemeasuring unit can be connected to another corresponding display unit.

■ The workpiece and measuring conditionsDepending on whether the laser is visible or invisible, the workpiece shape, and the surface roughness, measurement errors may result. If this is the case, perform calibration with a master workpiece which has dimensions, shape, and surface roughness similar to the actual workpiece to be measured. If measurement values show a large degree of dispersion due to the measuring conditions, increase the number of scans for averaging to improve the measurement accuracy.

■ Electrical interferenceTo avoid operational errors, do not route the signal cable and relay cable oftheLaserScanMicrometeralongsideahighvoltagelineorothercables capable of inducing noise current in nearby conductors. Ground all appropriate units and cable shields.

■ Connection to a computerIftheLaserScanMicrometeristobeconnectedtoanexternalpersonalcomputerviatheRS-232Cinterface,ensurethatthecableconnectionsconform to the specification.

■ Re assembly after removal from the baseObserve the following limits when re assembling the emission unit and reception unit to minimize measurement errors due tomisalignment of the laser's optical axis with the reception unit.

■ Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright,areattachedtotheLaserScanMicrometers as is appropriate.

Laser Scan Micrometers Quick Guide to Precision Measuring Instruments

a. Parallel deviation between reference lines C and D: X(inthetransversedirection)

■ Alignment within the horizontal plane

b.AnglebetweenreferencelinesCandD:θx(angle)

c.ParalleldeviationbetweenreferenceplanesAandB:Y(inheight)

■ Alignment within the vertical plane

d.AnglebetweenreferenceplanesAandB:θy(angle)

ModelDistance between

Emission Unitand Reception Unit

X and Y θx and θy

544-533, 544-53468mm(2.68")orless within0.5mm(.02") within0.4˚(7mrad)100mm(3.94")orless within0.5mm(.02") within0.3˚(5.2mrad)

544-535, 544-536130mm(5.12")orless within1mm(.04") within0.4˚(7mrad)350mm(13.78")orless within1mm(.04") within0.16˚(2.8mrad)

544-537, 544-538273mm(10.75")orless within1mm(.04") within0.2˚(3.5mrad)700mm(27.56")orless within1mm(.04") within0.08˚(1.4mrad)

544-539, 544-540321mm(12.64")orless within1mm(.04") within0.18˚(3.6mrad)700mm(27.56")orless within1mm(.04") within0.08˚(1.4mrad)

544-541, 544-542 800mm(31.50")orless within1mm(.04") within0.05˚(1.6mrad)

l Allowable limits of optical axis misalignment

X

Reference line CReference line D

x

Reference line C

Reference line D

Y

Reference plane A

Reference plane B

y

Reference plane A

Reference plane B

Page 17: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-57

Laser Scan MicrometerNon-contact, high-speed, high-precision measurement

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

G-57

G

■ Measurement Examples

Diameter

Dia.

Out of roundness

Reference edge

Reference edge

Reference edge

Reference edge

Gap

In-line measurement of glass fiber or fine wire diameter

Measurement of outer diameter of cylinder

Measurement of outer diameter and roundness of cylinder

X- and Y-axis measurement of electric cables and fibers

Measurement of thickness of film and sheet

Measurement of spacing of IC chip leads

Measurement of film sheet thickness

Measurement of laser disk and magnetic disk head movement

Measurement of gap between rollers

Measurement of tape width

Measurement of outer diameter of optical connector and ferrule

Measurement of form

Dual system for measuring a large outside diameter

Page 18: Laser Scan Micrometer - jaindah.com.t · Laser Scan Micrometer ... If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction

G-58

G

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.

G-58

G