10 Point Specification
Fiberlock Technologies • 150 Dascomb Rd • Andover, MA 01810 • www.fiberlock.com • 800.342.3755
LBC®Professional Lead Encapsulant/Sealant (Type III)
1. Product NameLBC® Lead Barrier CompoundType III - Interior/Exterior Encapsulant/En-casement Coating for lead-based paint
(#5801 - tintable white)
2. ManufacturerFiberlock Technologies, Inc.150 Dascomb RoadAndover, MA 01810 USAToll Free: 800-342-3755
Internet: www.fiberlock.com
3. Product DescriptionBASIC USE• LBC Type III is a high-solids, thermoplastic-elastomeric water-based copolymer blend-ed specifically to form a durable yet flexible barrier between lead-based paint and the
environment.• LBC Type III is a encapsulant for lead-based paint formulated to offer unparalleled cov-erage, economics and paint-like aesthetics while preserving historic and architectural
detail.• LBC Type III contains Bitrex®, a very bitter-tasting anti-ingestant to discour-age oral
contact with lead paint.
COMPOSITION & MATERIALSLBC is a water-based elastomeric thermo-plastic.
SIZEPackaged in 1 gallon cans and 5 gallon
pails.
YIELDLBC will yield as much as 120 ft2 per gallon at the required thickness of 7 dry mils (14 wet
mils) in ideal conditions.
COLORS
LBC is available in white, or can be tinted to a wide array of colors. Contact the manu-facturer for more details.
LIMITATIONS
Do not use LBC Type III on friction surfaces or movable closures such as door and win-dow jambs. Do not dilute or thin LBC Type III. Some states require a surface assessment by a licensed lead inspector before appli-cation. Contact your state Department of Health, or Fiberlock for more information. The minimum application surface tempera-ture is 45°F.If applying on wood substrate, ensure mois-
ture content is 11% or below.
4. Technical DataAPPLICABLE STANDARDS
• ASTM E-1795 Standard Specification for Non-Reinforced Liquid Coating Encapsulation
Products for Leaded Paint in Buildings.
PHYSICAL/CHEMICAL PROPERTIES
Refer to Table 1 for physical and chemical
properties of LBC Type III.
APPROVALS
• LBC has been independently tested at DL Laboratories, and met or surpassed the ASTM E-1795 Standard Specification forNon-Reinforced Liquid Coating Encapsula-tion Products for Leaded Paint in Buildings. Refer to Table 2 for ASTM E-1795 results.
• LBC Type III satisfies all HUD and EPA re-quirements which define encapsulation asa permanent abatement method.
• LBC Type III has been certified by the Mas-sachusetts Department of Public Health(No. DL-12362), approved by the State of
Ohio Department of Health, is accepted by
Properties
Product Specifications
Solids by Weight ± 2%:Solids by Volume ± 2%:Viscosity at 70°F:Specular Gloss:Flash Point: Shelf Life:
Calculated VOC:
LBC complies with the requirements for LEED® EQ Credit
4.2, low-emitting materials: paints and coatings.
Coverage
Smooth Surfaces:Porous Surfaces:
Drying Times (@ 70 - 77°F , 50% R.H.)
To Touch:To Recoat:Minimum Application Temperature: 45°F (7.2°C)
Available Package Sizes
5 gallon containersWeight Per Gallon ± 0.5 lbs:
Product Testing
Meets Standard:Certified For Use:
59.0%45.0%
95-120 Kreb Units5.5º ± 1 @ 60º
Non-combustible 24 Months Min.
(Original Sealed Containers)88 grams/liter
120 ft2/gal
80-120 ft2/gal
1-2 hours8-16 hours
11.24 lbs/gal
ASTM E-1795All 50 States
Fiberlock Technologies • 150 Dascomb Rd • Andover, MA 01810 • www.fiberlock.com • 800.342.3755
10 Point Specification
5801 - White LBCProfessional Lead Encapsulant / Sealant (Type III)
the New York State Department of Health, and meets or exceeds the abatement requir ments of all 50 states.
FIRE RATING
LBC has been tested by UL Labratories with a
Class “A” fire rating when tested in accordance
with ASTM E84, with a Flame Spread of “5”
and Smoke Developed of “0”.
5. InstallationPREPARATORY WORKBefore using LBC Type III, it is important to determine if the existing paint system is stable and well-adhered. This is done by perform-ing an adhesion tape test on the surface to be coated. Perform this test at least once on each different type of surface to be coated. Clean a small area, rinse with clean water, and allow to dry. Apply a 6-10” strip of pressure-sensitive tape (packing tape). Press the tape down with the rubber end of a pencil. After 90 seconds, remove (do not yank) the tape by pulling smoothly and slowly away from
the surface. If more than one square inch of paint is removed along with the tape, the adhesion of the existing paint system is poor. When this occurs, additional preparation (i.e., wet sanding, scraping, cleaning, etc.) must be done to remove poorly adhered paint. If less than one square inch of paint is removed from the substrate, the surface is sound and can be encapsulated.
SURFACE PREPARATION
Wood: Remove or mask electrical plates,
hardware, light fixture trim, and similar fittings prior to beginning encapsulation operations. Correct defects and clean surfaces affecting work in this section. Remove existing coatings that are flaking or unacceptable condition to receive coating. (All scraping and sanding should be done wet in order to avoid creat-ing lead dust. Check local, state, and federal regulations and guidelines regarding specific lead-based paint abatement practices.) Seal any marks or defects that might bleed through encapsulant with an appropriate primer. Clean mold-contaminated surfaces with IAQ 1000, or use an EPA Registered antimicrobial disinfectant cleaner such as Fiberlock IAQ 2000, Fiberlock IAQ 2500, Shockwave or
Shockwave RTU. Rinse with clean water and allow surface to dry.
Concrete and masonry: Remove dirt, chalk, loose mortar scale, salt alkalis, oil and grease with a lead-specific detergent. Rinse well and allow surface to dry. Apply masonry condi-tioner, such as Powerstone Plus, to prevent future chalking.
Plaster, Gypsum Wallboard: Fill all surface defects, wet sand smooth and spot prime with stain blocking primer, such as Power-Block. Glossy surfaces must be wet sanded or otherwise deglossed prior to application of encapsulant.
Ferrous Metal: Remove rust and scale by wire brushing. Remove dust, dirt, oil and grease with lead specific detergent. When dry, im-mediately apply a rust-inhibiting direct to metal primer, such as Power Rust Stop, to
prevent flash rusting.
Galvanized Metal: Remove dust, dirt, oil and grease with a lead-specific detergent. For areas where the galvanization has been dam-aged, apply a rust-inhibiting direct-to-metal primer, such as Power Rust Stop, to prevent
flash rusting.
Aluminum: Remove dust, dirt, oil and grease with a lead-specific detergent. Etch the surface using an etching type metal prep, or apply a tie-coat once the aluminum surface
is clean and dry.
MIXING
Mix LBC Type III thoroughly prior to applica-tion.
APPLICATION METHODS
Apply LBC Type III only after the existing paint system has been rendered clean, dry, sound and dull. LBC Type III can be applied using a brush, roller or airless sprayer. One application by airless spray, or two applications by brush/roller are typically sufficient to achieve the required minimum dry film thickness of 7 mils. When applying LBC by airless sprayer the best results can generally be achieved by using a tip size of 0.019 to 0.021 at 2500- 3000 psi. Spray in a “crosshatch” pattern (see figure 3) to
Lead-painted steel coated with LBC, National Gallery of Art, Washington, DC
Fiberlock Technologies • 150 Dascomb Rd • Andover, MA 01810 • www.fiberlock.com • 800.342.3755
10 Point Specification
5801 - White LBCProfessional Lead Encapsulant / Sealant (Type III)
achieve the greatest film thickness in a single coat. Clean up tools and drippings with warm,
soapy water before LBC Type III dries.
PRECAUTIONSLBC Type III must be applied when the atmo-sphere and surface temperatures during ap-plication and for 12 hours thereafter are above 45°F. Protect from freezing. Keep container
tightly sealed when not in use.
6. Availability and CostAVAILABILITYLBC Type III is available through a network of authorized distributors and paint stores. Contact Fiberlock Technologies, Inc. at 1-800-342-3755 for distributor information or visit
www.fiberlock.com.
COSTMaterial cost per square foot can be estimat-ed by dividing the price per gallon from an
authorized distributor by 120 ft2 per gallon.
7. WarrantyFiberlock Technologies, Inc., warrants LBC Type III for a minimum of 20 years from the date that the product is applied to form an effective barrier from the hazards of the encapsulated lead-based paint. The warranty described in this paragraph, expressed or implied, is includ-ing but not limited to the implied warranties of the salability and fitness for a particular purpose. User shall determine the suitability of LBC Type III’s use and assume any and all risks and liabilities which may arise in connection with the application of LBC Type III. This war-ranty is extended only to the purchaser of LBC Type III and does not apply to any damages which are a direct result of improper surface
preparation and/or application, including, but not limited to:1. The failure to properly apply LBC Type
III to a sound surface, which has been cleaned of foreign matter and dry at the time of application.
2. The failure to apply LBC Type III above the recommended minimum applica-tion temperature.
3. The failure to apply LBC Type III in full accordance with Fiberlock Technologies’ written application instructions and guidelines.
This warranty does not extend to, nor shall Fi-berlock Technologies be liable for any damage resulting from any abuse of the encapsulated surface by the tenants or occupants, improper maintenance, water damage, or other condi-tions beyond Fiberlock Technologies’ control. The sole and only liability under this warranty shall be, at Fiberlock Technologies’ option, ei-ther to replace the product if proved defective or to refund the purchase price paid. Fiberlock Technologies shall not be held liable for any incidental damages, or for any consequential damages to property, or any losses of revenue which may have been caused by a defect or failure of the product. The purchaser of this product must notify Fiberlock at 150 Das-comb Road, Andover, Massachusetts 01810 (800-342-3755) within 45 days to advise of any suspected manufacturing defects. This warranty gives the purchaser specific legal
rights and possible additional rights which may vary from state to state.
8. MaintenanceIf surfaces coated with LBC Type III are dam-aged, repair and re-apply LBC Type III immedi-
ately. Inspect for damage periodically.
9. Technical ServicesFiberlock Technologies, Inc. employs a knowledgeable factory trained team of field representatives. In addition, technical questions can be answered by one of our full time technical service representatives by calling 1-800-342-3755. Complete speci-fications and technical information can also
be obtained online at www.fiberlock.com.
10. Filing SystemAdditional information is available upon request.
.019- .021 TIP SIZE
2500-3000 PSI
*LEED® and related logo is a trademark owned by the U.S. Green
Building Council and is used by permission.
LBC over wood door frames at Fort Knox, KY.
Proper spray application of LBC Lead Barrier Compound
These suggestions and data are based on information we believe to be reliable. They are offered in good faith, but without guarantee, as conditions and methods of use of this product are beyond our control. Neither Fiberlock Technologies, Inc., nor its agents shall be responsible for the use or results of use of this product or any injury, loss or damage, direct or consequential. We recommend that the prospective user determine the suitability of this product for each specific project and for the health and safety of personnel working in the area.
For Technical Information call 800.342.3755
Fiberlock Technologies • 150 Dascomb Rd • Andover, MA 01810 • www.fiberlock.com • 800.342.3755
10 Point Specification
1048-0219
5801 - White LBCProfessional Lead Encapsulant / Sealant (Type III)
ASTM E-1795 RESULTS FOR LBC TYPE III
Requirement ASTM Test Result
Adhesion D 3359 5A Chalking D 4214 8Density or weight per gallon D 1475 11.5 lbs./gal.Dry abrasion resistance D 4060 7.9%Dry-film thickness D 1005, D 1186 7 milsFlexibility D 522 conformsImpact resistance D 2794 160 + in. lbs. Mildew resistance D 3273, D 3274 10Paintability D 3359 5A Scrub resistance D 2486 1350 cyclesSurface burning characteristics E 84 flame spread 5 smoke developed 0Tensile properties D 2370 tensile strength 565 psi elongation 48.9% elongation at 100 psi 1.2%VOC content D 3960 grams/liter 85 pounds/gallon 0.7Water and chemical resistance D 1308 50% ethanol conforms 5% acetic acid conforms 5% sodium hydroxide conforms 5% hydrochloric acid conforms 5% citric acid conforms corn oil conforms 2% phosphoric acid conforms 5% trisodium phosphate conforms distilled water conformsWater vapor transmission (perms) D 1653 0.28 grains/ft2/hr.Weathering/aging G 53 Weathering 1000 Hrs.: chalking 8 adhesion 5A flexibility conforms tensile strength 695 psi elongation -34.4% Aging 12 cycles: adhesion 5A flexibility conforms tensile strength 635 psi elongation -22.7% Aging 2 weeks at 40°C: adhesion 5A flexibility conforms tensile strength 633 psi elongation -5.5%
The ten part format used in this data sheet conforms to the editorial style prescribed byThe Construction Specifications Institute. The manufacturer is responsible for technical accuracy. ©2007 Fiberlock Technologies, Inc.