4
10 Point Specification Fiberlock Technologies 150 Dascomb Rd Andover, MA 01810 www.fiberlock.com 800.342.3755 LBC® Professional Lead Encapsulant/Sealant (Type III) 1. Product Name LBC ® Lead Barrier Compound Type III - Interior/Exterior Encapsulant/En- casement Coating for lead-based paint (#5801 - tintable white) 2. Manufacturer Fiberlock Technologies, Inc. 150 Dascomb Road Andover, MA 01810 USA Toll Free: 800-342-3755 Internet: www.fiberlock.com 3. Product Description BASIC USE • LBC Type III is a high-solids, thermoplastic- elastomeric water-based copolymer blend- ed specifically to form a durable yet flexible barrier between lead-based paint and the environment. • LBC Type III is a encapsulant for lead-based paint formulated to offer unparalleled cov- erage, economics and paint-like aesthetics while preserving historic and architectural detail. • LBC Type III contains Bitrex ® , a very bitter- tasting anti-ingestant to discour-age oral contact with lead paint. COMPOSITION & MATERIALS LBC is a water-based elastomeric thermo- plastic. SIZE Packaged in 1 gallon cans and 5 gallon pails. YIELD LBC will yield as much as 120 ft 2 per gallon at the required thickness of 7 dry mils (14 wet mils) in ideal conditions. COLORS LBC is available in white, or can be tinted to a wide array of colors. Contact the manu- facturer for more details. LIMITATIONS Do not use LBC Type III on friction surfaces or movable closures such as door and win- dow jambs. Do not dilute or thin LBC Type III. Some states require a surface assessment by a licensed lead inspector before appli- cation. Contact your state Department of Health, or Fiberlock for more information. The minimum application surface tempera- ture is 45°F. If applying on wood substrate, ensure mois- ture content is 11% or below. 4. Technical Data APPLICABLE STANDARDS ASTM E-1795 Standard Specification for Non- Reinforced Liquid Coating Encapsulation Products for Leaded Paint in Buildings. PHYSICAL/CHEMICAL PROPERTIES Refer to Table 1 for physical and chemical properties of LBC Type III. APPROVALS • LBC has been independently tested at DL Laboratories, and met or surpassed the ASTM E-1795 Standard Specification for Non-Reinforced Liquid Coating Encapsula- tion Products for Leaded Paint in Buildings. Refer to Table 2 for ASTM E-1795 results. • LBC Type III satisfies all HUD and EPA re- quirements which define encapsulation as a permanent abatement method. • LBC Type III has been certified by the Mas- sachusetts Department of Public Health (No. DL-12362), approved by the State of Ohio Department of Health, is accepted by Properties Product Specifications Solids by Weight ± 2%: Solids by Volume ± 2%: Viscosity at 70°F: Specular Gloss: Flash Point: Shelf Life: Calculated VOC: LBC complies with the requirements for LEED® EQ Credit 4.2, low-emitting materials: paints and coatings. Coverage Smooth Surfaces: Porous Surfaces: Drying Times (@ 70 - 77°F , 50% R.H.) To Touch: To Recoat: Minimum Application Temperature: 45°F (7.2°C) Available Package Sizes 5 gallon containers Weight Per Gallon ± 0.5 lbs: Product Testing Meets Standard: Certified For Use: 59.0% 45.0% 95-120 Kreb Units 5.5º ± 1 @ 60º Non-combustible 24 Months Min. (Original Sealed Containers) 88 grams/liter 120 ft 2 /gal 80-120 ft 2 /gal 1-2 hours 8-16 hours 11.24 lbs/gal ASTM E-1795 All 50 States

LBC® - Inline Distributing Company · 2019-05-17 · LBC Type III’s use and assume any and all risks and liabilities which may arise in connection with the application of LBC Type

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LBC® - Inline Distributing Company · 2019-05-17 · LBC Type III’s use and assume any and all risks and liabilities which may arise in connection with the application of LBC Type

10 Point Specification

Fiberlock Technologies • 150 Dascomb Rd • Andover, MA 01810 • www.fiberlock.com • 800.342.3755

LBC®Professional Lead Encapsulant/Sealant (Type III)

1. Product NameLBC® Lead Barrier CompoundType III - Interior/Exterior Encapsulant/En-casement Coating for lead-based paint

(#5801 - tintable white)

2. ManufacturerFiberlock Technologies, Inc.150 Dascomb RoadAndover, MA 01810 USAToll Free: 800-342-3755

Internet: www.fiberlock.com

3. Product DescriptionBASIC USE• LBC Type III is a high-solids, thermoplastic-elastomeric water-based copolymer blend-ed specifically to form a durable yet flexible barrier between lead-based paint and the

environment.• LBC Type III is a encapsulant for lead-based paint formulated to offer unparalleled cov-erage, economics and paint-like aesthetics while preserving historic and architectural

detail.• LBC Type III contains Bitrex®, a very bitter-tasting anti-ingestant to discour-age oral

contact with lead paint.

COMPOSITION & MATERIALSLBC is a water-based elastomeric thermo-plastic.

SIZEPackaged in 1 gallon cans and 5 gallon

pails.

YIELDLBC will yield as much as 120 ft2 per gallon at the required thickness of 7 dry mils (14 wet

mils) in ideal conditions.

COLORS

LBC is available in white, or can be tinted to a wide array of colors. Contact the manu-facturer for more details.

LIMITATIONS

Do not use LBC Type III on friction surfaces or movable closures such as door and win-dow jambs. Do not dilute or thin LBC Type III. Some states require a surface assessment by a licensed lead inspector before appli-cation. Contact your state Department of Health, or Fiberlock for more information. The minimum application surface tempera-ture is 45°F.If applying on wood substrate, ensure mois-

ture content is 11% or below.

4. Technical DataAPPLICABLE STANDARDS

• ASTM E-1795 Standard Specification for Non-Reinforced Liquid Coating Encapsulation

Products for Leaded Paint in Buildings.

PHYSICAL/CHEMICAL PROPERTIES

Refer to Table 1 for physical and chemical

properties of LBC Type III.

APPROVALS

• LBC has been independently tested at DL Laboratories, and met or surpassed the ASTM E-1795 Standard Specification forNon-Reinforced Liquid Coating Encapsula-tion Products for Leaded Paint in Buildings. Refer to Table 2 for ASTM E-1795 results.

• LBC Type III satisfies all HUD and EPA re-quirements which define encapsulation asa permanent abatement method.

• LBC Type III has been certified by the Mas-sachusetts Department of Public Health(No. DL-12362), approved by the State of

Ohio Department of Health, is accepted by

Properties

Product Specifications

Solids by Weight ± 2%:Solids by Volume ± 2%:Viscosity at 70°F:Specular Gloss:Flash Point: Shelf Life:

Calculated VOC:

LBC complies with the requirements for LEED® EQ Credit

4.2, low-emitting materials: paints and coatings.

Coverage

Smooth Surfaces:Porous Surfaces:

Drying Times (@ 70 - 77°F , 50% R.H.)

To Touch:To Recoat:Minimum Application Temperature: 45°F (7.2°C)

Available Package Sizes

5 gallon containersWeight Per Gallon ± 0.5 lbs:

Product Testing

Meets Standard:Certified For Use:

59.0%45.0%

95-120 Kreb Units5.5º ± 1 @ 60º

Non-combustible 24 Months Min.

(Original Sealed Containers)88 grams/liter

120 ft2/gal

80-120 ft2/gal

1-2 hours8-16 hours

11.24 lbs/gal

ASTM E-1795All 50 States

Page 2: LBC® - Inline Distributing Company · 2019-05-17 · LBC Type III’s use and assume any and all risks and liabilities which may arise in connection with the application of LBC Type

Fiberlock Technologies • 150 Dascomb Rd • Andover, MA 01810 • www.fiberlock.com • 800.342.3755

10 Point Specification

5801 - White LBCProfessional Lead Encapsulant / Sealant (Type III)

the New York State Department of Health, and meets or exceeds the abatement requir ments of all 50 states.

FIRE RATING

LBC has been tested by UL Labratories with a

Class “A” fire rating when tested in accordance

with ASTM E84, with a Flame Spread of “5”

and Smoke Developed of “0”.

5. InstallationPREPARATORY WORKBefore using LBC Type III, it is important to determine if the existing paint system is stable and well-adhered. This is done by perform-ing an adhesion tape test on the surface to be coated. Perform this test at least once on each different type of surface to be coated. Clean a small area, rinse with clean water, and allow to dry. Apply a 6-10” strip of pressure-sensitive tape (packing tape). Press the tape down with the rubber end of a pencil. After 90 seconds, remove (do not yank) the tape by pulling smoothly and slowly away from

the surface. If more than one square inch of paint is removed along with the tape, the adhesion of the existing paint system is poor. When this occurs, additional preparation (i.e., wet sanding, scraping, cleaning, etc.) must be done to remove poorly adhered paint. If less than one square inch of paint is removed from the substrate, the surface is sound and can be encapsulated.

SURFACE PREPARATION

Wood: Remove or mask electrical plates,

hardware, light fixture trim, and similar fittings prior to beginning encapsulation operations. Correct defects and clean surfaces affecting work in this section. Remove existing coatings that are flaking or unacceptable condition to receive coating. (All scraping and sanding should be done wet in order to avoid creat-ing lead dust. Check local, state, and federal regulations and guidelines regarding specific lead-based paint abatement practices.) Seal any marks or defects that might bleed through encapsulant with an appropriate primer. Clean mold-contaminated surfaces with IAQ 1000, or use an EPA Registered antimicrobial disinfectant cleaner such as Fiberlock IAQ 2000, Fiberlock IAQ 2500, Shockwave or

Shockwave RTU. Rinse with clean water and allow surface to dry.

Concrete and masonry: Remove dirt, chalk, loose mortar scale, salt alkalis, oil and grease with a lead-specific detergent. Rinse well and allow surface to dry. Apply masonry condi-tioner, such as Powerstone Plus, to prevent future chalking.

Plaster, Gypsum Wallboard: Fill all surface defects, wet sand smooth and spot prime with stain blocking primer, such as Power-Block. Glossy surfaces must be wet sanded or otherwise deglossed prior to application of encapsulant.

Ferrous Metal: Remove rust and scale by wire brushing. Remove dust, dirt, oil and grease with lead specific detergent. When dry, im-mediately apply a rust-inhibiting direct to metal primer, such as Power Rust Stop, to

prevent flash rusting.

Galvanized Metal: Remove dust, dirt, oil and grease with a lead-specific detergent. For areas where the galvanization has been dam-aged, apply a rust-inhibiting direct-to-metal primer, such as Power Rust Stop, to prevent

flash rusting.

Aluminum: Remove dust, dirt, oil and grease with a lead-specific detergent. Etch the surface using an etching type metal prep, or apply a tie-coat once the aluminum surface

is clean and dry.

MIXING

Mix LBC Type III thoroughly prior to applica-tion.

APPLICATION METHODS

Apply LBC Type III only after the existing paint system has been rendered clean, dry, sound and dull. LBC Type III can be applied using a brush, roller or airless sprayer. One application by airless spray, or two applications by brush/roller are typically sufficient to achieve the required minimum dry film thickness of 7 mils. When applying LBC by airless sprayer the best results can generally be achieved by using a tip size of 0.019 to 0.021 at 2500- 3000 psi. Spray in a “crosshatch” pattern (see figure 3) to

Lead-painted steel coated with LBC, National Gallery of Art, Washington, DC

Page 3: LBC® - Inline Distributing Company · 2019-05-17 · LBC Type III’s use and assume any and all risks and liabilities which may arise in connection with the application of LBC Type

Fiberlock Technologies • 150 Dascomb Rd • Andover, MA 01810 • www.fiberlock.com • 800.342.3755

10 Point Specification

5801 - White LBCProfessional Lead Encapsulant / Sealant (Type III)

achieve the greatest film thickness in a single coat. Clean up tools and drippings with warm,

soapy water before LBC Type III dries.

PRECAUTIONSLBC Type III must be applied when the atmo-sphere and surface temperatures during ap-plication and for 12 hours thereafter are above 45°F. Protect from freezing. Keep container

tightly sealed when not in use.

6. Availability and CostAVAILABILITYLBC Type III is available through a network of authorized distributors and paint stores. Contact Fiberlock Technologies, Inc. at 1-800-342-3755 for distributor information or visit

www.fiberlock.com.

COSTMaterial cost per square foot can be estimat-ed by dividing the price per gallon from an

authorized distributor by 120 ft2 per gallon.

7. WarrantyFiberlock Technologies, Inc., warrants LBC Type III for a minimum of 20 years from the date that the product is applied to form an effective barrier from the hazards of the encapsulated lead-based paint. The warranty described in this paragraph, expressed or implied, is includ-ing but not limited to the implied warranties of the salability and fitness for a particular purpose. User shall determine the suitability of LBC Type III’s use and assume any and all risks and liabilities which may arise in connection with the application of LBC Type III. This war-ranty is extended only to the purchaser of LBC Type III and does not apply to any damages which are a direct result of improper surface

preparation and/or application, including, but not limited to:1. The failure to properly apply LBC Type

III to a sound surface, which has been cleaned of foreign matter and dry at the time of application.

2. The failure to apply LBC Type III above the recommended minimum applica-tion temperature.

3. The failure to apply LBC Type III in full accordance with Fiberlock Technologies’ written application instructions and guidelines.

This warranty does not extend to, nor shall Fi-berlock Technologies be liable for any damage resulting from any abuse of the encapsulated surface by the tenants or occupants, improper maintenance, water damage, or other condi-tions beyond Fiberlock Technologies’ control. The sole and only liability under this warranty shall be, at Fiberlock Technologies’ option, ei-ther to replace the product if proved defective or to refund the purchase price paid. Fiberlock Technologies shall not be held liable for any incidental damages, or for any consequential damages to property, or any losses of revenue which may have been caused by a defect or failure of the product. The purchaser of this product must notify Fiberlock at 150 Das-comb Road, Andover, Massachusetts 01810 (800-342-3755) within 45 days to advise of any suspected manufacturing defects. This warranty gives the purchaser specific legal

rights and possible additional rights which may vary from state to state.

8. MaintenanceIf surfaces coated with LBC Type III are dam-aged, repair and re-apply LBC Type III immedi-

ately. Inspect for damage periodically.

9. Technical ServicesFiberlock Technologies, Inc. employs a knowledgeable factory trained team of field representatives. In addition, technical questions can be answered by one of our full time technical service representatives by calling 1-800-342-3755. Complete speci-fications and technical information can also

be obtained online at www.fiberlock.com.

10. Filing SystemAdditional information is available upon request.

.019- .021 TIP SIZE

2500-3000 PSI

*LEED® and related logo is a trademark owned by the U.S. Green

Building Council and is used by permission.

LBC over wood door frames at Fort Knox, KY.

Proper spray application of LBC Lead Barrier Compound

Page 4: LBC® - Inline Distributing Company · 2019-05-17 · LBC Type III’s use and assume any and all risks and liabilities which may arise in connection with the application of LBC Type

These suggestions and data are based on information we believe to be reliable. They are offered in good faith, but without guarantee, as conditions and methods of use of this product are beyond our control. Neither Fiberlock Technologies, Inc., nor its agents shall be responsible for the use or results of use of this product or any injury, loss or damage, direct or consequential. We recommend that the prospective user determine the suitability of this product for each specific project and for the health and safety of personnel working in the area.

For Technical Information call 800.342.3755

Fiberlock Technologies • 150 Dascomb Rd • Andover, MA 01810 • www.fiberlock.com • 800.342.3755

10 Point Specification

1048-0219

5801 - White LBCProfessional Lead Encapsulant / Sealant (Type III)

ASTM E-1795 RESULTS FOR LBC TYPE III

Requirement ASTM Test Result

Adhesion D 3359 5A Chalking D 4214 8Density or weight per gallon D 1475 11.5 lbs./gal.Dry abrasion resistance D 4060 7.9%Dry-film thickness D 1005, D 1186 7 milsFlexibility D 522 conformsImpact resistance D 2794 160 + in. lbs. Mildew resistance D 3273, D 3274 10Paintability D 3359 5A Scrub resistance D 2486 1350 cyclesSurface burning characteristics E 84 flame spread 5 smoke developed 0Tensile properties D 2370 tensile strength 565 psi elongation 48.9% elongation at 100 psi 1.2%VOC content D 3960 grams/liter 85 pounds/gallon 0.7Water and chemical resistance D 1308 50% ethanol conforms 5% acetic acid conforms 5% sodium hydroxide conforms 5% hydrochloric acid conforms 5% citric acid conforms corn oil conforms 2% phosphoric acid conforms 5% trisodium phosphate conforms distilled water conformsWater vapor transmission (perms) D 1653 0.28 grains/ft2/hr.Weathering/aging G 53 Weathering 1000 Hrs.: chalking 8 adhesion 5A flexibility conforms tensile strength 695 psi elongation -34.4% Aging 12 cycles: adhesion 5A flexibility conforms tensile strength 635 psi elongation -22.7% Aging 2 weeks at 40°C: adhesion 5A flexibility conforms tensile strength 633 psi elongation -5.5%

The ten part format used in this data sheet conforms to the editorial style prescribed byThe Construction Specifications Institute. The manufacturer is responsible for technical accuracy. ©2007 Fiberlock Technologies, Inc.