LIGHT MEASUREMENT SYSTEMS
WIDE DYNAMIC RANGE SPECTROMETERS
SOLUTION-BASED SOFTWARE
LIGHT MEASUREMENT ACCESSORIESwww.labsphere.com/illumia
LEADING THE WAY in Light Measurement Systems
Welcome to Labsphere! ILLUMIA®
Since 1894, when Richard Ulbricht built the first working integrating sphere, the integrating sphere photometer has been used to measure the total luminous flux of light sources.
Today, the name Labsphere has become synonymous with the integrating sphere while, total radiant flux, luminous flux, and associated color parameters are measured and applied for the determination of lamp lumen efficacy, color rendering, appearance, optical performance and quality.
With applications that include test and calibration in general lighting, automotive lighting, fiber illuminators, LCD backlighting, solid state lighting, LEDs, architectural lighting, lasers and laser diodes, Labsphere integrating sphere photometers, radiometers and spectrometers have become a staple tool in light test labs and industry
throughout the world.
Labsphere light measurement systems are designed to minimize spatial distribution sensitivity associated with directional and divergent light sources and provide easy to use systems designed in concert with industry measurement standards.
Labsphere has created thousands of light measurement systems from universal bench top applications to fully integrated automated production line systems with cus-tomers ranging from universities and innovative start ups to the world leaders in general and automotive lighting industry and government organizations.
Our customers rely upon our extensive knowledge and experience to provide high-end products that address their specific requirements.
FEATURES INCLUDE:
• Wide dynamic range allows a single sphere to measure a wide range of light levels• NIST traceable standards for in-house recalibration• Spectral results in milliseconds• Spectraflect® interior sphere coating• Conforms to national standard measurement geometries
MEASURE:
• Total Spectral Flux • Luminous Flux • Radiant Flux • Chromaticity• CCT & CRI • Peak Wavelength • Dominant Wavelength • I, V and Luminous Efficacy • And Many More Measurements
*NVLAP is in full conformance with the standards of the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC), including ISO/IEC 17025 and Guide 58.
History
illumia® Light Measurement Systems are designed to minimize spatial distribution sensitivity associated with directional and divergent light sources and provide easy to use systems designed in concert with industry measurement standards.
All systems are certified by our calibration laboratory team with extensive experience in performing application specific calibrations, all of which are traceable to the National Institute of Standards and Technologies (NIST).
Labsphere’s Spectraflect® sphere coating is a proprietary, high-reflectance coating that is useful over a wide wave-length range. This non-toxic material is near-Lambertian in character and easily applied by spray to any substrate. Spectraflect® is a specially formulated barium sulfate
coating which produces a nearly perfect diffuse reflectance surface. Spectraflect® is generally used as a reflectance coating in the UV-VIS-NIR region and is most effective over the wavelength range from 300 to 2400 nm. The range can be stretched to 185 nm before binder absorption peaks begin to appear.
The coating is opaque with reflectance up to 98% over the wavelength range from 400 to 1100 nm. Spectraflect® is thermally stable to approximately 100°C.
illumia® Light Measurement Systems are easily custom-ized with a choice of three high-speed spectrometer series and a variety of interchangeable light measurement accessories. Achieve spectral results in milliseconds and conform to national standard measurement geometries.
This Product Guide is intended to give you an introduction and overview of Labsphere light measurement products and services.
Labsphere’s Light Measurement Systems offer a turn-key solution for R&D, production and quality assurance. They feature systems withthe highest accuracy and dynamic range available today
Labsphere offers three Light Measurement Series –
illumia®lite illumia® illumia®pro We invite you to visit our website at www.labsphere.com to view detailed data sheets for each product as well as our online library of technical articles and application notes.
We look forward to earning your business!
CDS-600 / 610
The highly sensitive CDS-600 and CDS-610 mini CCD Array Spectrometers offer low noise and a broad spectral response with calibrated ranges from 200 to 850 nm or 350 to 1050 nm.
When coupled with a Labsphere integrating sphere, the spectrometers avoid the inherent photometric errors associated with filter-based photometers; data is accurate even for narrow-band light sources such as LEDs, fluorescent lamps, and discharge lamps.
In production, these systems can increase the throughput of quality assurance testing which facilitates improved statistical process control for higher manufacturing consistency and greater product quality.
CDS-1100 / 2100
The CDS-1100 and CDS-2100 are based on the proven Crossed Czerny-Turner spectrograph with an electrically cooled back thinned CCD detector designed for efficient stray-light rejection.
These spectral engines include user activated integrated shutters for real-time dark correction and intuitive software modules for research, development and production.
When calibrated for the application with auxiliary hardware and MtrX-SPEC software, these multi-channel spectral analyzers provide rapid data acquisition for spectroradiometric, photopic, colorimetric, and electrical characteristics of the device under test (DUT).
CDS-3010 / 3030
Labsphere continues to set the standard in developing efficient test and measurement instruments for the lighting and LED industries with the introduction of the CDS-30x0 High Speed CCD array spectrometer series.
This best in class spectrometer series is designed to measure critical spectral and optical characteristics of devices with the greatest reliability, speed and accuracy for demanding manufacturing environments.
The fiberoptic connectors easily connect the CDS-30x0 series to a variety of measurement devices for both spectroradiometric and photometric measurement.
SPECTROMETERS
* with stray light correction software** with ND filters
see brochurefor product details
see brochurefor product details
www.labsphere.com/illumia
illumia®lite illumia® 600/610 illumia® 1100/2100 illumia® 30x0 illumia®pro 500
Luminous Flux Measurement 3 3 3 3 3
Spectral Measurements 3 3 3 3 3
Overall System Accuracy ++ ++ +++ +++ ++Sphere Sizes 25cm dia to 3m dia 3 3 3 3
Absorption Correction Lamps 3 3 3 3 3
Calibration Lamps 3 3 3 3
Dynamic Range ++ + ++ +++** +Single Scan Dynamic Range ++ + ++ +++ +Low Stray Light + ++ +++ +++ ++* Continuous Measurements + + + +++ ++Speed of Minimum Exposure Time +++ +++ + ++ +++ Sensitivity + ++ + +++ ++ Maximum Exposure Time + + ++ +++ +Low Level Light Measurement ++ + ++ +++ +Stability for Long Integration Times @ Low Light Levels ++ + ++ +++ +Shutter 3 3 3 Temperature Controller Active Device Temperature Control 3
Temperature Sweeps 3
Voltage Sweeps 3
Current Sweeps 3
Soak Time Triggering 3
Performance Incandescent lamps +++ +++ +++ +++ +++HID / CFL Lamps + +++ +++ +Low Level Sources + + +++ +++ +Blue LEDs + ++ +++ +++ ++* White LEDs ++ ++ +++ +++ ++* Customization Options Customized Ports / Baffles 3 3 3 3 3
Rotation Systems 3 3 3 3
Ambient Temp. Controlled Systems 3 3 3 3
Software Options MtrX-SPEC 3 3 3 3 illumia®pro Software 3
Standards LM-79 Compliant 3 3 3 3
LM-80 Compliant 3
SPHERES
The MtrX-SPEC software module is the most intuitive plat-form for calibrating and analyzing spectral radiometric, photometric and colorimetric properties of light sources ranging from simple lamps and LEDs to solid state lighting assemblies and traditional indoor and outdoor lighting systems. Need to track life or performance with time? Want to know how the dominant wavelength shifts with operation? The MtrX-SPEC temporal feature allows you to monitor optical and electrical performance versus elapsed operating time.
3m light measurement sphere design.
SOFTWARE
• Environmentally and Optically Stable Coatings• Provides High Diffuse Reflectance for Applications in UV-VIS-NIR • IESNA LM-78, LM-79 and LM-80• Light-Tight Closure• Base-up or Base-down Lamp Mounting• Socket Mounting Plate• Adjustable Fluorescent Lamp Holder• Variable Height Electrical Supply Tube• Interchangeable Baffles• Temperature Sensor Mounting Port• Absorption Correction Lamp Port• Absorption Correction Lamp Baffle
LAMPS
Labsphere’s Light Measurement Spheres are avail-able in 10", 20", 40", 65", 76", 3m and 4m. The sphere design complies with IESNA LM-78, LM-79 and LM-80 standards to deliver accurate and reproducible measurements.
The near lambertian properties of the sphere’s interior coating, Spectraflect®, provides a uniform dispersion of light that integrates and reduces hotspots better than any other sphere coating available. Spectraflect® exhibits reflectance values up to 98% and is spectrally flat throughout the visible spectrum, therefore providing higher optical efficiency for low lumen lamps.
The three meter lamp measurement integrating sphere accommodates light sources positioned base up, base-down or longitudinally to easily and efficiently measure virtually any lamp type, including fluorescent up to 2 meter in length. The
design also allows for forward and partial flux measurement of test sources that are board-mounted or heat-sinked.
The large sphere better integrates light for more reliable testing of a device’s photometric and colorimetric performance with measurements of Total Spectral Flux, Luminous Flux, Correlated Color Temperature (CCT), Color Rendering Index and Chromaticity.
LM-79: Select sphere size
Omnidirectional - area of the light source not larger than 2% of your sphere.2Pi measurement - opening of sphere should be less than 1/3 of the sphere diameter.Tubular - the size of the light source should be less than 2/3 of sphere diameter.
Auxiliary Lamps for Absorption Correction Industry standards and Labsphere recommend applying absorption correction techniques Self-absorption correc-tion is critical, since the physical size and shape of SSL products and lamps under test are typically very different from the reference lamp size and shape. The use of an absorption correction lamp can correct for self-absorption errors.
Lamp assemblies mount onto a Labsphere 1-inch port frame and auxiliary lamp port on our Light Measurement Spheres with no modifications required.
Calibrated Lamp StandardsLabsphere’s Total Spectral and Total Lumi-nous Flux Lamp Standards are selected for their stability and reproducibility. Each lamp has
been carefully screened, seasoned and calibrated at our Optical Calibration Laboratory under the guidelines recommended by the IESNA (Illuminating Engineering Society of North America) to provide the highest degree of accuracy. A calibration certificate verifying traceability
to NIST is provided with each lamp.
Calibrated Forward Flux Standards Labsphere’s Lamp Standards of Total Spectral Flux provide an exceptional artifact for cali-brating integrating sphere spectrometers for total spectral radiant flux responsivity from 350 to 1050 nm. Labsphere’s Lamp Standards
of Forward Spectral Flux are selected for their stability and reproducibility.The selected lamps
are then calibrated directly to the NIST lumen, for a calibration result you can rely on.
1.5m and 2m light measurement sphere design.
POWER SUPPLIES
LPS-100 / LPS-150
LPS-100 and the LPS-150 Power Supplies ramp up in only 20 seconds, extending the life and performance of the lamp. Timers track lamp operation time and power supply operations can be run from the front panel or remotely off a TTL connection.
The LPS Power Supplies operate single-supply or intricate multi-power. Light measurement system upgrades and sensor calibration systems are easily implemented through a wide variety of interchangeable light source assemblies, lamp stan-dards, and complimentary power supplies.
LMS-025 250 - 2500 Ambient temp can not exceed 100C
unlimited N/A Ambient temp can not exceed 100C
.25cm diameter
LMS-050 250 - 2500 Ambient temp can not exceed 100C
unlimited N/A Ambient temp can not exceed 100C
< 7cm diameter, < 33cm long
LMS-100 250 - 2500 Ambient temp can not exceed 100C
unlimited N/A Ambient temp can not exceed 100C
< 14cm diameter, < 67cmm long
LMS-165 250 - 2500 Ambient temp can not exceed 100C
unlimited Ambient temp can not exceed 100C
Ambient temp can not exceed 100C
< 23cm diameter, < 110cm long
LMS-195 250 - 2500 Ambient temp can not exceed 100C
unlimited Ambient temp can not exceed 100C
Ambient temp can not exceed 100C
< 27cm diameter, < 130cm long
SPHERE SPECIFICATIONS
Spheres Size Order No Required Footprint L x W x H
Sphere Weight
Sphere Assembly
Frame Style
Spectraflect®
Coating Reflectance
LMS-025 25cm AA-80000-025 closed45.9cm x 30.2cm x 39.1cmopen
64.2cm x 46.8cm x 39.1cm
4kg Extruded Au 400nm 97.1% 500nm 97.4%600nm 97.2% 700nm 96.8%800nm 96.3%900nm 96.2% 1000nm 96.0%
LMS-050 50cm AA-80000-050 closed74.1cm x 50.4cm x 74.0cmopen
103.7cm x 89.9cm x 74.0cm
20kg Extruded Au 400nm 97.1% 500nm 97.4%600nm 97.2% 700nm 96.8%800nm 96.3%900nm 96.2% 1000nm 96.0%
LMS-100 100cm AA-80000-100 closed128.0cm x 98.1cm x 166.7cm
open174.4cm x 165.9cm x 166.7cm
91kg Extruded Au 400nm 97.1% 500nm 97.4%600nm 97.2% 700nm 96.8%800nm 96.3%900nm 96.2% 1000nm 96.0%
LMS-165 165cm AA-80000-165 closed/open188.6cm x 285.0cm x 213.7cm
300kg Extruded Au 400nm 97.1% 500nm 97.4%600nm 97.2% 700nm 96.8%800nm 96.3%900nm 96.2% 1000nm 96.0%
LMS-195 195cm AA-80000-195 closed/open213.2cm x 285.0cm x 232.6cm
347kg Extruded Au 400nm 97.1% 500nm 97.4%600nm 97.2% 700nm 96.8%800nm 96.3%900nm 96.2% 1000nm 96.0%
Spheres Radiometric Range of
the Coating
Max. Lamp Wattage
Incandascent
Max. Lamp Wattage
White LED
Max. Lamp Wattage HID
Max. Lamp Wattage
UV
Max. Lamp Size (LM-79) 4pi geometry
ILLUMIA® 600 / 610 SPECIFICATIONS
System illumia®
with 25cm sphere
illumia® with 50cm
sphere
illumia® with 100cm
sphere
illumia® with 165cm
sphere
illumia® with 195cm
sphere
illumia® 600 AA-80020-025 AA-80020-050 AA-80020-100 AA-80020-165 AA-80020-195
illumia® 610 AA-80030-025 AA-80030-050 AA-80030-100 AA-80030-165 AA-80030-195
Sphere LMS-025 LMS-050 LMS-100 LMS-165 LMS-195
SpectrallyCalibrated Lamp
SCL-600AS-01335-000
2PI-1-INT-600AS-80003-000
2PI-1-INT-1400AS-80004-000
2PI-1-INT-1400AS-80004-000
2PI-1-INT-1400AS-80004-000
Lamp Socket Assy. 4pi 2pi 2pi 2pi 2pi
Power Supply LPS-100-0260AS-02600-260
LPS-100-0260AS-02600-260
LPS-150-0268AS-02656-268
LPS-150-0268AS-02656-268
LPS-150-0268AS-02656-268
Aux Lamp AUX-35AS-02576-035
AUX-35AS-02576-035
AUX-75AS-02576-075
AUX-75AS-02576-075
AUX-75AS-02576-075
Power Supply LPS-100-0307AS-02600-307
LPS-100-0307AS-02600-307
LPS-100-0625AS-02600-625
LPS-100-0625AS-02600-625
LPS-100-0625AS-02600-625
Software (required, sold separately)
Light Measurement
Software, MtrX-Spec
Light Measurement
Software, MtrX-Spec
Light Measurement
Software, MtrX-Spec
Light Measurement
Software, MtrX-Spec
Light Measurement
Software, MtrX-Spec
Typical Min Power in 350-400nm range (W) with 100 S/N ratio
TBD TBD TBD TBD TBD
Typical Min Luminous Power white(lm)
0.40 1.6 6.4 17 23
Typical Min Power in Blue (lm)
0.04 0.16 0.64 1.7 2.3
Typical Min Powerin Green (lm)
0.12 0.48 1.9 5.1 6.9
Typical Min Power in Red (lm)
0.06 0.24 0.96 2.5 3.5
Upper range Ambient temperature
can not exceed 100C
Ambient temperature
can not exceed 100C
Ambient temperature
can not exceed 100C
Ambient temperature
can not exceed 100C
Ambient temperature
can not exceed 100C
4pi Kit included AS-80001-050 AS-80001-100 AS-80001-165 AS-80001-195
Ambient Temp Probe and Monitor
TPM-100 TPM-100 TPM-400 TPM-400 TPM-400
Forward Flux Std FFS-100-400 FFS-100-400 FFS-100-1000 FFS-100-1000 FFS-100-1000
Above Systems Include:
Performance:
Optional Accessories:
ILLUMIA® 1100 / 2100 SPECIFICATIONS ILLUMIA® 3020 / 3030 SPECIFICATIONS
ILLUMIA® 1100 / 2100 SPECIFICATIONS
System illumia®
with 25cm sphere
illumia® with 50cm
sphere
illumia® with 100cm
sphere
illumia® with 165cm
sphere
illumia® with 195cm
sphere
illumia® 1100 AA-80040-025 AA-80040-050 AA-80040-100 AA-80040-165 AA-80040-195
illumia® 2100 AA-80050-025 AA-80050-050 AA-80050-100 AA-80050-165 AA-80050-195
Sphere LMS-025 LMS-050 LMS-100 LMS-165 LMS-195
SpectrallyCalibrated Lamp
SCL-600AS-01335-000
2PI-1-INT-600AS-80003-000
2PI-1-INT-1400AS-80004-000
2PI-1-INT-1400AS-80004-000
2PI-1-INT-1400AS-80004-000
Lamp Socket Assy. 4pi 2pi 2pi 2pi 2pi
Power Supply LPS-100-0260AS-02600-260
LPS-100-0260AS-02600-260
LPS-150-0268AS-02656-268
LPS-150-0268AS-02656-268
LPS-150-0268AS-02656-268
Aux Lamp AUX-35AS-02576-035
AUX-35AS-02576-035
AUX-75AS-02576-075
AUX-75AS-02576-075
AUX-75AS-02576-075
Power Supply LPS-100-0307AS-02600-307
LPS-100-0307AS-02600-307
LPS-100-0625AS-02600-625
LPS-100-0625AS-02600-625
LPS-100-0625AS-02600-625
Software (required, sold separately)
Light Measurement
Software, MtrX-Spec
Light Measurement
Software, MtrX-Spec
Light Measurement
Software, MtrX-Spec
Light Measurement
Software, MtrX-Spec
Light Measurement
Software, MtrX-Spec
Typical Min Power in 350-400nm range (W) with 100 S/N ratio
TBD TBD TBD TBD TBD
Typical Min Luminous Power white(lm)
0.56 2.2 9.0 24 32
Typical Min Power in Blue (lm)
0.14 0.56 2.2 5.9 8.1
Typical Min Powerin Green (lm)
0.34 1.4 5.4 14 20
Typical Min Power in Red (lm)
0.10 0.40 1.6 4.2 5.8
Upper range Ambient temperature
can not exceed 100C
Ambient temperature
can not exceed 100C
Ambient temperature
can not exceed 100C
Ambient temperature
can not exceed 100C
Ambient temperature
can not exceed 100C
4pi Kit included AS-80001-050 AS-80001-100 AS-80001-165 AS-80001-195
Ambient Temp Probe and Monitor
TPM-100 TPM-100 TPM-400 TPM-400 TPM-400
Forward Flux Std FFS-100-400 FFS-100-400 FFS-100-1000 FFS-100-1000 FFS-100-1000
Above Systems Include:
Performance:
Optional Accessories:
ILLUMIA® 1100 / 2100 SPECIFICATIONS
ILLUMIA® 3020 / 3030 SPECIFICATIONS
Above Systems Include:
Performance:
Optional Accessories:
System illumia®
with 50cm sphere
illumia® with 100cm
sphere
illumia® with 165cm
sphere
illumia® with 195cm
sphere
illumia® 3020 AA-80080-050 AA-80080-100 AA-80080-165 AA-80040-195
illumia® 3030 AA-80090-050 AA-80090-100 AA-80090-165 AA-80050-195
Sphere LMS-050 LMS-100 LMS-165 LMS-195
SpectrallyCalibrated Lamp
2PI-1-INT-050AS-80006-000
2PI-1-INT-050AS-80006-000
2PI-1-INT-600AS-80003-000
2PI-1-INT-600AS-80003-000
Lamp Socket Assy. 2pi 2pi 2pi 2pi
Power Supply LPS-100-0105AS-02600-105
LPS-100-0105AS-02600-105
LPS-100-0260AS-02600-260
LPS-100-0260AS-02600-260
Aux Lamp AUX-10AS-02576-010
AUX-35AS-02576-035
AUX-35AS-02576-035
AUX-35AS-02576-035
Power Supply LPS-100-0167AS-02600-167
LPS-100-0307AS-02600-307
LPS-100-0307AS-02600-307
LPS-100-0307AS-02600-307
Software (required, sold separately)
Light Measurement
Software, MtrX-Spec
Light Measurement
Software, MtrX-Spec
Light Measurement
Software, MtrX-Spec
Light Measurement
Software, MtrX-Spec
Typical Min Power in 350-400nm range (W) with 100 S/N ratio
<1.97e-4 <7.86e-4 <2.14e-3 <2.99e-3
Typical Min Luminous Power white(lm)
0.281.1 3.0 4.0
Typical Min Power in Blue (lm)
0.07 0.28 0.74 1.0
Typical Min Powerin Green (lm)
0.17 0.68 1.8 2.5
Typical Min Power in Red (lm)
0.05 2.0 0.53 0.72
Upper range Ambient temperature
can not exceed 100C
Ambient temperature
can not exceed 100C
Ambient temperature
can not exceed 100C
Ambient temperature
can not exceed 100C
4pi Kit AS-80001-050 AS-80001-100 AS-80001-165 AS-80001-195
Ambient Temp Probe and Monitor
TPM-100 TPM-400 TPM-400 TPM-400
Forward Flux Std FFS-100-400 FFS-100-1000 FFS-100-1000 FFS-100-1000
231 Shaker Street • North Sutton • New Hampshire 03260 • USAPhone: +1.603.927.4266 Fax: +1.603.927.4694 www.labsphere.com
Labsphere Locations and Dealers Around the Globe:
North America
CanadaMexico United States
South America
BrazilColombia
Europe
AustriaBelgiumDenmarkFinlandFranceGermanyGreeceHungaryIrelandItalyLuxembourgNetherlandsNorwayPolandPortugalRussiaSpainSwedenSwitzerlandTurkeyUnited Kingdom
Africa & Middle East
EgyptIsraelSaudi Arabia
Asia/Pacific
AustraliaChinaHong KongIndiaIndonesiaJapanKoreaMalaysiaNew ZealandRussiaSingaporeTaiwanThailandTurkey