Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
• EasyInstallation&Retrofitting:SimplyBypassBallastandPlug-in.Runson ACDirectLineVoltage.EliminatesCompatibility,PowerLoss&Lifetime IssuesandMaintenanceCostsassociatedwithBallasts
• FullBrightnesswithInstantOnandInstantRestrike
• OptimalDesignforHorizontalorVerticalMountSockets
• >80CRIforGreatVisibility
• SuitableforDryorDampLocation
• LowPowerConsumption
• UniversalVoltage:100-277V,AC
• Heat&ImpactResistant,UVProtected,Non-Yellowing,OpticalGradeLens
• ExcellentHeatDissipationwithProprietary-DesignedHeatSink
• CoolOperation:DoesnotaddtoHeatLoad(upto90%lessheatthan Incandescent)whileproducingBrilliantlyBrightLight
• Non-Combustible.MadefromFlameRetardant,EngineeredPolymer, theBaseisMechanicallyStrongandHeat-Resistantupto435°F(225°C)
• SafeandReliable:IsolatedCircuitDesign
• Maintenance-FreeOperation:Lastsupto50timeslongerthan IncandescentBulb.LowersCostsbyReducingRelampFrequency
•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalRequirements. FacilitatesLEED®points
•NoElectro-Magnetic(EMi)orRadioFrequencyInterference(RFi)
•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable
• 5YearLimitedWarranty
Page:1of2
HighPerformance12WLEDPLLamp
MercuryFree
IdealforHigh-qualityIlluminationin:
• DownLights • WallScones • Bollards • WallPacks
• DecorativeLighting • AccentLighting • CeilingLights • TaskLighting
• PedestrianTunnels • PendantLights • WalkwayLighting
• StairwellLighting • CorridorLighting • CarriageLanterns
32W / 42WCFL Equivalent
IncreasedSustainability
Up to50,000Hours
Longer Life
Reduction ofup to 90%
Energy Costs
Radiation-FreeNo Humming
IRUV
No IR/UV
No Noise
LM-80 TestedISTMT Tested
Reliability
Vibration andShock Resistant
Solid State
120 LpWLM-79 Tested
Lumen Efficacy
Reliable andLong-Lasting
Warranty
5years
LowConsumption
Power
Zero Interference
No EMi / RFi
Wide andUniform
Beam Angle
120°
PLUG-iN LAMP TM
LED
Lampcanbeorientedinanyposition-doesnotaffectordiminishthelifeofthelamp
Universal Burning Positioning
BaseDown Base
Sideways
BaseUp
G24d G24q Gx24d Gx24q
G24d-1 G24q-1 Gx24d-2 Gx24q-1 G24d-2 G24q-2 Gx24d-3 Gx24q-2 G24d-3 G24q-3 Gx24q-3 Gx24q-4
HyLiteLEDPLlampsofferatrulyuniversalG24base-designedtoreplaceboth2-pinand4-pinG24baseslisted:
NOLEAD, MERCURY, HEAVY METALS
OR TOXIC GASES
98%RECYCLABLE
1.75”
(45m
m)
0.6”
(15m
m)
6.75
" (17
1mm
)
1.4” (35mm)
12WHL-G24-12W
Incandescent Halogen CFL HyLite
120W 90W 32W / 42W 12W
90% 87% 63%-72% Energy Savings (%)
Replacewith 12W
HL-G24-12W
TheHyLiteHighPerformanceLEDPLLampisanidealEnergy-EfficientreplacementforCFLandIncandescentBulbinstallationsinExistingandNewFixtures.The12WLEDPLLampprovidesEnergy-EfficientIlluminationataWideBeamAngleof120°andreplaces32W/42WCFLBulbs,effectivelyreducingEnergyConsumptionby63%-72%andasmuchas90%whenreplacing120WIncandescentBulbs.HyLiteLEDPLLampsareratedatupto50,000hoursofLampLife.Thisis50timeslongerthanatraditionalIncandescentBulb,and7timeslongerthanaCFLBulb.ThissignificantlyreducesEnergyUsageandCostsaswellasMaintenanceExpenditures.
350° Rotatable Base for
Directional Lighting
E361357
Not Suitable for
Enclosed Fixtures
AC Direct Type B
• ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-20°C(-4°F)toaMaximumof+45°C(113°F)
• Efficacy:120LpW • CRI:>80 • BeamAngle:120º • Max.THD(%):<10%
• PowerFactor:>0.9 • Protection:IP20 • RatedLife:50,000Hrs.* • Warranty:5Years
• AmbientWorkingTemperature:-4ºF~+113ºF(-20ºC~+45ºC) • BaseType:G24 • UniversalInputVoltage
• CCT:3500K(NeutralWhite),4000K(CoolWhite)and5000K(DayLight) 100~277V,AC50/60Hz.
*Depending upon the ambient temperature of the installation location
Page:2of2
Model Delivered InputLine Dimensions&Weight(each) No. Watts Lumens Current Width Height NetWeight
HL-G24-12W 12 1308~1360 96mA@120V 1.4”(35mm) 5.75”(145mm) 4oz.(115g)
HyLite PL Lamp, HL-G24-12W
Photometrics
Intensity: (Unit, cd)0
30
60
90
120
150-/+180
-150
-120
-90
-60
-30
Note: The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance
1 m3.3 ft.
Height
2 m6.5 ft.
3 m9.8 ft.
4 m13.1 ft.
5 m16.4 ft.
Angle: 113.80° DiameterCenter E (lx/fc)
3.06 m10 ft.
6.11 m20 ft.
9.16 m30 ft.
12.22 m40 ft.
15.27 m50 ft.
458.90 lx42.63 fc
114.73 lx10.66 fc
50.99 lx4.74 fc
28.68 lx2.66 fc
18.36 lx1.71 fc
Ave. E (lx/fc)
179.47 lx16.67 fc
44.87 lx4.17 fc
19.94 lx1.85 fc
11.22 lx1.04 fc
7.18 lx0.67 fc
IlluminanceDistance Curve
0
93.5
187.0
280.5
374.0
467.5 Angle [50% Max.] [10% Max]C180/360 113.8° 169.4°C0/180 113.8° 169.4°C90/270 107.6° 152.5°
OrderingforHyLite12WLEDPLLampwithG24Base
Model Suffix (CCT,ºK)
HL-G24-12W -35K 3500K=NeutralWhite(NW) -40K 4000K=CoolWhite(CW) -50K 5000K=Daylight(DL)
PLUG-iN LAMP TM
LED
As part of the company’s continuous product improvement program, HyLite reserves the right to change materials or modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.
AC Direct Type B
Warning - Risk of Fire or Electric Shock• DisableallPowertotheLampbeforeInspection,Installation,orRemoval.FailuretodosowillcreateaHazardousandFatalWorkingEnvironment.TheInstallermustdetermineandverify whether120Vto277VACisbeingutilizedattheLuminairebeforeInstallation.ImproperVoltagematchingcanresultinPerformanceDegradationand/orPhysicalDamage.
• WiringmodificationforHyLiteLEDLampInstallationrequiresknowledgeofLuminaireElectricalSystems.Ifnotqualified,DONOTattemptInstallation.ContactaQualifiedElectrician. DONOTMakeorAlteranyOpenHolesinanEnclosureforWiringorElectricalComponentsduringInstallation.
• SuitableforuseinDryorDampLocations.DonotusewheredirectlyexposedtoLiquid,Vapor,RainorWeather.Non-Submergible(notwatertight).Lampmustbeinstalledinaccordancewith National,State,and/orLocalElectricalCodes.DoNotOpen–NoUserServiceablePartsInside.
• TopreventearlyLampfailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaminimumof-20°C(-4°F)toamaximumof+45°C(113°F).
• LuminaireWiring,Ballast,orotherElectricalPartsmaybeDamagedwhenInstalling.AlwayscheckforenclosedWiringandComponents.DONOTBlockLightemanatingfromProductinWhole orPart,asthismayCauseanUnsafeCondition.TopreventWiringDamageorAbrasion,DONOTexposeWiringtoedgesofSheetMetalorotherSharpObjects.
• OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation.ThiswillensureLumen MaintenanceandextenditsWorkingLife.WhenproductsareusedinOutdoorFixtures,ensurethespaceisWaterproofandWellVentilated.
• NotforuseonaDimmerorRemoteControls.ThisLampmustbecontrolledonlybyeitheraSwitchoranElectronicPhotosensor.DonotuseaMechanicalSensor.
• NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.
• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.
©2017-2020HyLiteLED,LLC.,USA Formoreinformation,pleasevisit:https://hyliteledlighting.com/ 022820
WARNINGNotSuitableforTotallyEnclosedLuminairesorFullyEnclosedFixtures
Not Suitable for
Enclosed Fixtures
Installation:HyLiteLEDLampsaredesignedtoworkoff100Vto277V,AC.Ballast(ifequipped)mustbebypassedorremovedfromthefixturebeforeinstallingthelamp.EliminatingtheBallastsavesadditionalcostsrelatedtoMaintenance,EnergyConsumptionandPerformance.By-passingBallastwillalsoensurethatthereisnoEMi/RFinterference.
Failure to Follow Instructionswill VOIDWarranty. It canalso result in an ElectricShock,orFire.NOTFORTOTALLYENCLOSEDLUMINAIRESOREMERGENCYLIGHTING.NOTFORUSEWITHDIMMERS.