4
LED T8 InstantFit Lamp 12T8/48-3500 IF 10/1 Philips LED T8 InstantFit Lamps are an ideal energy saving choice for existing linear fluorescent fixtures. Product data General Characteristics Main Application Industrial Cap-Base G13 Rated Avg. Life (Hours) 40000 hr Nominal Lifetime hours 40000 hr B50L70 40000 Light Technical Characteristics Color Code 835 Beam Angle 160 D Correlated Color Temperature 3500 K CRI 83 Rated Luminous Flux 1500 Lm LLMF - end nominal lifetime 70 % Colour consistency <6 Rated Beam Angle 160 D Electrical Characteristics Wattage 12 W Voltage 120-277 V Line Frequency 50/60 Hz Power Factor 0.9 (min) - Dimmable No Rated Wattage 12.0 W Starting Time 0.5 (max) s Lamp voltage 120-277 V Warm-up Time to 60% Light Outp instant full light Energy saving product Yes Suitable for accent lighting No Temperature Characteristics T-case maximum 42 (max) C Operating tempera- ture -20 (min), 45 (max) C T-Storage -45 (min), 65 (max) C Environmental characteristics Energy Efficiency Label (EEL) A+ Energy consumption kWh/1000h 14.5 kWh Measuring Conditions Switching cycle 50000X Product Dimensions Length A1 1198.0 mm Fixing Hole Distance A2 Length 1205.0 mm Length A3 1212.0 mm Mounting hole diam- eter 25.68 mm Circular outline dimension 28 mm Approval & Application Chars VDE marking No CE marking Yes UL certificate Yes

LED T8 InstantFit Lamp - Total Bulk Lighting · LED T8 InstantFit Lamp 12T8/48-3500 IF 10/1 Philips LED T8 InstantFit Lamps are an ideal energy saving choice for existing linear fluorescent

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LED T8 InstantFit Lamp - Total Bulk Lighting · LED T8 InstantFit Lamp 12T8/48-3500 IF 10/1 Philips LED T8 InstantFit Lamps are an ideal energy saving choice for existing linear fluorescent

LED T8 InstantFit Lamp12T8/48-3500 IF 10/1

Philips LED T8 InstantFit Lamps are an ideal energy saving choice forexisting linear fluorescent fixtures.

Product data

• General CharacteristicsMain Application IndustrialCap-Base G13Rated Avg. Life(Hours)

40000 hr

Nominal Lifetimehours

40000 hr

B50L70 40000

• Light Technical CharacteristicsColor Code 835Beam Angle 160 DCorrelated ColorTemperature

3500 K

CRI 83Rated Luminous Flux 1500 LmLLMF - end nominallifetime

70 %

Colour consistency <6Rated Beam Angle 160 D

• Electrical CharacteristicsWattage 12 WVoltage 120-277 VLine Frequency 50/60 HzPower Factor 0.9 (min) -Dimmable NoRated Wattage 12.0 WStarting Time 0.5 (max) sLamp voltage 120-277 VWarm-up Time to60% Light Outp

instant full light

Energy savingproduct

Yes

Suitable for accentlighting

No

• Temperature CharacteristicsT-case maximum 42 (max) COperating tempera-ture

-20 (min), 45 (max) C

T-Storage -45 (min), 65 (max) C

• Environmental characteristicsEnergy EfficiencyLabel (EEL)

A+

Energy consumptionkWh/1000h

14.5 kWh

• Measuring ConditionsSwitching cycle 50000X

• Product DimensionsLength A1 1198.0 mmFixing Hole DistanceA2 Length

1205.0 mm

Length A3 1212.0 mmMounting hole diam-eter

25.68 mm

Circular outlinedimension

28 mm

• Approval & Application CharsVDE marking NoCE marking YesUL certificate Yes

Page 2: LED T8 InstantFit Lamp - Total Bulk Lighting · LED T8 InstantFit Lamp 12T8/48-3500 IF 10/1 Philips LED T8 InstantFit Lamps are an ideal energy saving choice for existing linear fluorescent

RoHS compliance YesKEMA Keur certifi-cate

Yes

• Product DataProduct number 453597Full product name 12T8/48-3500 IF 10/1

Short product name 12T8/48-3500 IF 10/1Pieces per Sku 1eop_pck_cfg 10Skus/Case 10Bar code on pack 46677453596Bar code on case 50046677453591Logistics code(s) 929001124004eop_net_weight_pp 0.000 kg

Dimensional drawing

A1

A2

A3

D2

D1

12T8/48-3500 IF 10/1Product A (Norm) A1 (Norm) A2 (Norm) A3 (Norm) B (Min) B (Norm) B (Max) D (Min) D (Norm) D (Max) D1 (Norm) D2 (Norm)

LEDtube 1200mm 12W G13/835 - 1198.0 1205.0 1212.0 - - - - - - 25.68 28

13

G13

LED T8 InstantFit Lamp

© 2014 Koninklijke Philips N.V. (Royal Philips)All rights reserved.

Specifications are subject to change without notice. Trademarks are the property ofKoninklijke Philips N.V. (Royal Philips) or their respective owners.

www.philips.com/lighting

2014, November 18data subject to change

Page 3: LED T8 InstantFit Lamp - Total Bulk Lighting · LED T8 InstantFit Lamp 12T8/48-3500 IF 10/1 Philips LED T8 InstantFit Lamps are an ideal energy saving choice for existing linear fluorescent

Installation, Ballast & Specification GuidePhilips LED T8 InstantFit Lamp

Please take the time to read this quick installation guide. The guide contains importantinformation and notes regarding the installation and operation.

• Please keep this Quick Installation Guide for future reference.

• Product is not dimmable

• Operates on instant-start ballasts only1.

• Philips LED T8 InstantFit lamps are not compatible with luminaires that use a remote starter.

• Modifications to the product void the warranty.

• Suitable to replace T8 fluorescent lamps as specified on the product label.

1 Please refer to www.philips.com/instantfit for latest ballast compatibility guide.

FF0002

DQD 507 Rev. 2012-05-22 Page 1

Certificate of Compliance Certificate: 2662008 Master Contract: 155397

Project: 2662008 Date Issued: September 27, 2013

Issued to: Philips Lighting Company, A Div. of 200 Franklin Square Dr. Somerset, NJ 08873 USA Attention: J. Cyre

The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent

indicator 'US' for US only or without either indicator for Canada only

Issued by:

Robin Huang

PRODUCTS

CLASS 3426 36 - LUMINAIRES- Luminaire Fittings LED Tubular Lamp Retrofit Kits

LED tubular lamps as direct replacements for 25W/48T8/HF, 28W/48T8/HF, 30W/48T8/HF, 32W/48T8/RS; F32T8, 25W; F32T8, 28W; F32T8, 30W; F32T8, 32W fluorescent lamp type, for dry or damp location use, Models 9290002840, 9290002841, 9290002842, 9290002862.

The Ballast models that the LED Tubular Lamp can be used with are:

Philips Models: GOPA-2P32-SC, GOPA-4P32-SC, GOPA-2P32-LW-SC, GOPA-4P32-LW-SC, IOPA-2P32-N, IOPA-4P32-N, IOPA-2P32-LW-N, IOPA-4P32-LW-N, IOP-2P32-N, IOP-4P32-N, IOP-2P32-LW-N, IOP-4P32-LW-N, ICN-2P32-N, ICN-4P32-N ULT Models: B232I347HP-A, B432I347HP GE Models: GE232MAX347-N, GE432MAX347-N UltraSave Models: UT232347, UT432347

Page 4: LED T8 InstantFit Lamp - Total Bulk Lighting · LED T8 InstantFit Lamp 12T8/48-3500 IF 10/1 Philips LED T8 InstantFit Lamps are an ideal energy saving choice for existing linear fluorescent

Instructions

1. Switch-off power to the luminaire

2. Remove diffuser (if provided)

3. Remove the existing fluorescent lamps from the luminaire.

- Note: Verify the fluorescent tube type is listed on the label of Philips LED T8 InstantFit lamp.

6. Switch on power to the luminaire.

1 2 Fluorescent 3 Fluorescent 5 LED T8 InstantFit 6 LED T8 InstantFit 6

CAUTION – IF THE LAMP OR LUMINAIRE EXHIBITS UNDESIRABLE OPERATION (BUZZING, FLICKERING, ETC.), IMMEDIATELY TURN OFF POWER, REMOVE LAMP FROM LUMINAIRE AND CONTACT THE MANUFACTURERCAUTION – RISK OF FIRE. DO NOT INSTALL IN A PRE-HEAT LUMINAIREWARNING: RISK OF FIRE, USE ONLY IN PLACE OF FLUORESCENT LAMPS SPECIFIED ON LABEL. SEE INSTRUCTIONS. THIS LAMP ONLY OPERATES ON ELECTRONIC BALLASTS. IF LAMP DOES NOT LIGHT WHEN THE LUMINAIRE IS ENERGIZED, REMOVE LAMP FROM LUMINAIRE AND CONTACT LAMP MANUFACTURER OR QUALIFIED ELECTRICIANTHIS PRODUCT MAY CAUSE INTERFERENCE TO RADIO EQUIPMENT AND SHOULD NOT BE INSTALLED NEAR MARITIME SAFETY COMMUNICATIONSEQUIPMENT OR OTHER CRITICAL NAVIGATION OR COMMUNICATION EQUIPMENT OPERATING BETWEEN 0.45 – 30MHZ.

Lamps must be operated within an ambient fixture temperature of -4F (-20c) and 113F (45c) to ensure UL compliance.

MISE EN GARDE – SI LA LAMPE OU LE LUMINAIRE MONTRE UN FONCTIONNEMENT INAPPROPRIÉ (BOURDONNEMENT, CLIGNOTEMENT, ETC.), INTERROMPRE IMMÉDIATEMENT LE COURANT, ENLEVER LA LAMPE DU LUMINAIRE ET CONTACTER LE FABRICANT.

MISE EN GARDE – RISQUE D’INCENDIE. NE PAS INSTALLER DANS UN LUMINAIRE DU TYPE À PRÉCHAUFFAGE.

CETTE LAMPE FONCTIONNE SEULEMENT SUR UN BALLAST ÉLECTRONIQUE. SI LA LAMPE NE S’ALLUME PAS LORSQUE LE LUMINAIRE EST MIS SOUS TENSION, RETIRER LA LAMPE DU LUMINAIRE ET CONTACTER LE FABRICANT DE LA LAMPE OU UN ÉLECTRICIEN QUALIFIÉ.CE PRODUIT EST SUSCEPTIBLE DE CAUSER DE L’INTERFÉRENCE AVEC LES ÉQUIPEMENTS RADIO ET NE DEVRAIT PAS ÊTRE INSTALLÉPRÈS DES APPAREILS DE COMMUNICATION DE SÉCURITÉ MARITIME OU TOUT AUTRE ÉQUIPEMENT DE COMMUNICATION OU DE LA NAVIGATION QUI FONCTIONNE À UNE BANDE ENTRE 0,45 ET 30 MHZ.

© 2014 Koninklijke Philips N.V. All rights reserved.06/14

www.philips.com

Philips Lighting North America Corporation200 Franklin Square Drive Somerset, NJ 08873Phone: 85 5-486-2216

Philips Lighting281 Hillmount RoadMarkham, OntarioCanada L6C 2S3Phone: 800-555-0050

1 -3 Fluorescent 4 LED T8 InstantFit 6

U - Bend

AVERTISSEMENT: RISQUE D’INCENDIE. UTILISER UNIQUEMENT SUR PLACE DES LAMPES FLUORESCENTES PRÉCISÉES SUR L'ÉTIQUETTE. VOIR LES INSTRUCTIONS

Lampes doivent être exploités dans une température ambiante de fixation de-4F (-20c) et 113F (45c) pour assurer la conformité UL.

CES DISPOSITIFS NE DOIT ÊTRE UTILISÉE QU'AVEC APPAREILS D'URGENCE DE SORTIE OU FEUX D'URGENCE DE SORTIE

THESE DEVICES ARE NOT INTENDED FOR USE WITH EMERGENCY EXIT FIXTURES OR EMERGENCY EXIT LIGHTS.

5 LED T8 InstantFit

4-5. Install the Philips LED T8 InstantFit lamp (One for each fluorescent lamp removed, ensure pins are firmly seated in lampholders).

- For U-bend only, please ensure lamp is secured by clip