7.3
Lenel Access Hardware Demo System User Guide
Lenel® OnGuard® 7.3 Lenel Access Hardware Demo System User GuideThis guide is item number DOC-971, revision 7.002, May 2016.© 2016 United Technologies Corporation. All rights reserved.
Lenel®, OnGuard® and Prism® (Registered trademarks of UTC Fire & Security Americas Corporation, Inc.) Lenel is a part of UTC Climate, Controls & Security, a unit of United Technologies Corporation.All trademarks are the property of their respective owners.Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of UTC Fire & Security Americas Corporation, Inc.Non-English versions of Lenel documents are offered as a service to our global audiences. We have attempted to provide an accurate translation of the text, but the official text is the English text, and any differences in the translation are not binding and have no legal effect.The software described in this document is furnished under a license agreement and may only be used in accordance with the terms of that agreement. Crystal Reports for Windows is a trademark of Crystal Computer Services, Inc.
OnGuard includes ImageStream® Graphic Filters. © 2002 eBT International, Inc. (f/k/a Inso Corporation). All rights reserved. ImageStream Graphic Filters and ImageStream are registered trademarks of eBT International, Inc. (f/k/a Inso Corporation).Integral and FlashPoint are trademarks of Integral Technologies, Inc. Portions of this product were created using LEADTOOLS ©1991-2011, LEAD Technologies, Inc. ALL RIGHTS RESERVED. Portions of this product are licensed under US patent 5,327,254 and foreign counterparts. Active Directory, Microsoft, SQL Server, Windows, and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Oracle is a registered trademark of Oracle and/or its affiliates. Other names may be trademarks of their respective owners.Other product names mentioned may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Table of Contents
CHAPTER 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
CHAPTER 2 Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7Intelligent System Controller (ISC) LNL-2220 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7Single Reader Interface Module LNL-1300 Series 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8XceedID (LNL-PR10) Proximity Mini-Mullion Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8HID (800-8045-3020) MIFARE Sector Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8HID (RWKL550) OSDP LCD iCLASS Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
CHAPTER 3 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11User Name and Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11LNL-2220 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
LAN Connection (Default Connection) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
LNL-1300 Single Reader Interface Configuration (Port 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13LNL-2220 IDRC Onboard Reader 1 Configuration (Port 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15LNL-2220 IDRC Onboard Reader 2 Configuration (Port 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16LNL-2220 IDRC Reader Interface Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18LNL-2220 IDRC Reader Interface Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19Local I/O Setup for Auxiliary Inputs and Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20Card Formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Enabling User Commands/Extended Hold Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Command Keypad Templates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Command Programming Assignment (HID OSDP Reader) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Lenel Access Hardware Demo System User Guide 3
Table of Contents
APPENDIX A Configuration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
ISC Communication Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32ISC Setup Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Single Reader Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
AUX Output 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Dual Reader Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Reader 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34AUX Input 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35AUX Output 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35AUX Input 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Reader 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36AUX Input 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37AUX Output 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37AUX Input 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
APPENDIX B Demonstration Scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Valid User Presents Card to Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39User Presents Invalid Badge to Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Valid User Arms the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
APPENDIX C Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4 Lenel Access Hardware Demo System User Guide
CHAPTER 1 Introduction
The Lenel Access Hardware Demo System (referred to throughout this guide as “Demo Case”) includes the following hardware:
• ISC LNL-2220• SRI LNL-1300
Lenel Access Hardware Demo System User Guide 5
Introduction
6
• XceedID (LNL-PR10) Proximity Mini-Mullion Reader• HID (800-8045-3020) Mifare Sector Reader• HID (RWKL550) OSDP LCD iClass Reader• Three inputs• Three outputs• Output reset button• Amber LED power indicator• Three door contacts with tipped LED• RS-485 asset reader connection• 6-foot retractable CAT 5e crossover cable• LenelProx w/Magstripe Sample Card• HID 2k/2 application area iClass sample card• Mifare Sample Card• 12 VDC universal power supply• Soft-sided carrying caseIn addition, a laptop PC is required to run OnGuard software that was installed with the Demo Case database.
• For information on how to install SQL Server and OnGuard with the Demo database, refer to the OnGuard Installation Guide.
• For a description of the hardware installed in the Demo Case, refer to Chapter 2: Hardware on page 7.
• For a description of the Lenel hardware and OnGuard database configuration for the Demo Case, refer to Chapter 3: Configuration on page 11.
• For a reference table overview of the OnGuard Demo Case database configuration, refer to Appendix A: Configuration Overview on page 31.
• For a description of scenarios you can use to demonstrate the Lenel access hardware and OnGuard software, refer to Appendix B: Demonstration Scenarios on page 39.
• For a Demo Case wiring interconnect diagram, refer to Appendix C: Wiring Diagram on page 41.
Lenel Access Hardware Demo System User Guide
CHAPTER 2 Hardware
This chapter describes the hardware included in the Lenel Access Hardware Demo System. For wiring interconnections, refer to Wiring Diagram on page 41.
Intelligent System Controller (ISC) LNL-2220The LNL-2220 Intelligent System Controller (IDRC) by Lenel provides a single board solution for interfacing one or two doors with the OnGuard software. In addition, other I/O and reader interface modules can be added on the LNL-2220's downstream port to expand its capabilities. The LNL-2220 revolutionizes access control system architecture by allowing Ethernet connection directly from an entry location to the OnGuard server, while still providing the security, functionality, and modularity of Lenel’s proven access series hardware platform. The LNL-2220 is scalable for any access control application, from the most basic to the most sophisticated. In the event of communication loss, the LNL-2220 allows nearly all local functionality to continue unimpaired until the server connection is restored.
Utilizing its native Ethernet communications and an advanced 32-bit processor, the LNL-2220 can communicate upstream to the host computer through its Ethernet port (with a throughput up to eight times greater than the fastest serial connections) or at up to 115.2Kbps using RS-232 communication directly or through an external dial-up modem. The LNL-2220 can store up to 250,000 cardholders in non-volatile flash memory, and supports selective download for larger cardholder databases. The downstream RS-485 two-wire port can be used to connect up to 32 devices (maximum 64 doors).
Two on-board reader ports support Data1/Data0, Clock/Data, Bioscrypt RS-485 readers and the bidirectional RS-485 Open Supervised Device Protocol (OSDP) communications. Each LNL-2220 supports up to eight different card formats. The LNL-2220 includes eight inputs that support normally open, normally closed, supervised and unsupervised circuits. In addition, four output relays support fail-safe or fail-secure operation.
Lenel Access Hardware Demo System User Guide 7
Hardware
8
Single Reader Interface Module LNL-1300 Series 2UTC Fire & Security Americas Corporation, Inc. offers a Single Reader Interface (SRI) module for access control solutions. Access control card readers, keypads, or readers with keypads that use standard Wiegand Data1/Data0 or Clock/Data communication are supported, as are those that support the new bidirectional RS-485 Lenel OnGuard Supervised Device Protocol (OSDP). Lock, unlock, and facility code offline access modes are supported on all readers connected to the SRI. Each DRI supports up to eight different card formats as well as issue codes for both magnetic and Wiegand card formats.
The SRI provides a vital link between the Intelligent System Controller (ISC) and the card reader attached to the interface. As many as 32 SRI modules can be multi-dropped using RS-485 2-wire communication up to 4,000 feet per port away from the ISC. Each SRI module is individually addressed for increased reporting capabilities with OnGuard access control software applications. The SRI includes two inputs that support normally open, normally closed, supervised, and non-supervised circuits. Two output relays support fail-safe or fail-secure operation.
XceedID (LNL-PR10) Proximity Mini-Mullion ReaderThe XceedID LNL-PR10 Proximity Mini-Mullion Reader is a great option for a tight space in a proximity-only access control installation. This cost-effective reader is well suited for both indoor and outdoor installations. Similar to all Ingersoll Rand Readers, the LNL-PR10 operates on a Wiegand interface, is compatible with all industry-leading 125 kHz proximity credentials, and is completely ISO compliant. Its small but attractive design mirrors the styling of the aptiQ Multi-Technology Reader line-up, and is available in a variety of color options.
HID (800-8045-3020) MIFARE Sector ReaderThe HID MIFARE Sector Reader is a flexible, highly secure and stylish contactless smart card reader ideal for customers that require a customizable reader for new or existing installations. The reader is designed for a wide variety of applications from entry-level access control to secure ID management.
The reader’s keypad adds an extra layer of protection for higher security installations.
HID (RWKL550) OSDP LCD iCLASS ReaderUsing 13.56 MHz contactless smart card technology, the HID OSDP LCD iCLASS Reader provides users with new options for supporting multi-factor identity authentication. Combine a contactless card presentation with a personal identification number (PIN) to securely control access to high security areas. Turn the reader into a remotely controlled device, enabling a host to read and write data on an iCLASS card in addition to controlling the LCD to display time, badge holder information, and so on.
Versatile communication interfaces allow any host to connect to and communicate with the reader. Local operation mode (access control) allows the reader to interface with the highly secure iCLASS access control application, sending card data one-way to a host over a Wiegand, RS232 or RS485 (point-to-point) physical link while displaying canned messages to the user (multi-language support configurable). Use remote operation mode (pass-through) to open up two-way communications over
Lenel Access Hardware Demo System User Guide
HID (RWKL550) OSDP LCD iCLASS Reader
RS232, RS485 (point-to-point) or USB interfaces. Read and write unique application data on iCLASS cards while controlling the LCD, beeper and LEDs.
Lenel Access Hardware Demo System User Guide 9
Hardware
10
Lenel Access Hardware Demo System User GuideCHAPTER 3 Configuration
This chapter describes the hardware and software configuration of the Lenel Access Hardware Demo System.
User Name and PasswordFor the Lenel Access Hardware Demo System, the user name is SA and the password is l3n3l.
LNL-2220 Configuration
LAN Connection (Default Connection)The Lenel Access Hardware Demo System has a network cable cutout on the top of the unit where the cable will connect directly into the LNL-2220. By default, all dip switches are set to OFF and the factory default IP address is set to 192.168.0.251, Address 0. To assign a different parameters to the ISC, refer to the OnGuard Hardware Installation Guide.
LNL-2220 TabSystem Administration > Access Control > Access Panels
LNL-2220 Settings
Parameter Setting
Address 0
Baud rate 38.4 kbps
RAM 16 MB
PIN 1 to 4 digits
Lenel Access Hardware Demo System User Guide 11
Configuration
12
Connection Tab
Options Tab
Lenel Access Hardware Demo System User Guide
LNL-1300 Single Reader Interface Configuration (Port 2)
LNL-1300 Single Reader Interface Configuration (Port 2)System Administration > Access Control > Readers and Doors
LNL-1300 Settings
Parameter Setting
Address 31
Baud rate 38.4 kbps
Input power 12 Vdc unregulated
Communication interface RS-485 2-wire
General Tab
Parameter Setting
Name 1-HID OSDP Reader
Port 2
Address 31
Reader number 0
Lenel Access Hardware Demo System User Guide 13
Configuration
14
Settings Tab
Controls Tab
LNL-1300 Outputs
SRI Output Address Setting
RLY 1 Door Strike HID OSDP Reader
RLY 2 Armed
Aux Outputs Tab
Parameter Setting
Output 1 Name Armed
Output 1 Pulse Time (sec) 5
Lenel Access Hardware Demo System User Guide
LNL-2220 IDRC Onboard Reader 1 Configuration (Port 3)
LNL-2220 IDRC Onboard Reader 1 Configuration (Port 3)System Administration > Access Control > Readers and Doors
General Tab
Parameter Setting
Name 3-MIFARE Reader w/PINPad
Address 0
Reader number 0
Lenel Access Hardware Demo System User Guide 15
Configuration
16
Settings Tab
Controls Tab
LNL-2220 IDRC Onboard Reader 2 Configuration (Port 3)System Administration > Access Control > Readers and Doors
General Tab
Parameter Setting
Name 2-Lenel OpenProx
Address 0
Reader number 1
Lenel Access Hardware Demo System User Guide
LNL-2220 IDRC Onboard Reader 2 Configuration (Port 3)
Settings Tab
Controls Tab
Lenel Access Hardware Demo System User Guide 17
Configuration
18
LNL-2220 IDRC Reader Interface InputsSystem Administration > Access Control > Readers and Doors
Aux Inputs Tab for MIFARE Reader w/PinPad (IN 3 and IN 4)
Aux Inputs Tab for Lenel OpenProx (IN 6 and IN 7)
IDRC Input Address Description
IN 1 Non-supervised - Door 1 Contact MIFARE Reader w/PINPad
IN 2 Non-supervised - Door 1 REX MIFARE Reader w/PINPad
IN 3 Non-supervised - Door 1 Aux 1 - Door
IN 4 Non-supervised - Door 1 Aux 2 - Window
IN 5 Non-supervised - Door 2 Contact - Lenel OpenProx
IN 6 Non-supervised - Door 2 REX - Lenel OpenProx
IN 7 Non-supervised - Door 2 Aux 1 - Motion
IN 8 Non-supervised - Door 2 Aux 2 - Reset
Lenel Access Hardware Demo System User Guide
LNL-2220 IDRC Reader Interface Outputs
LNL-2220 IDRC Reader Interface OutputsSystem Administration > Access Control > Readers and Doors
Aux Outputs Tab for MIFARE Reader w/PinPad (OUT 2)
Aux Outputs Tab for Lenel OpenProx (OUT 4)
DRI Output Address Description
OUT 1 Non-supervised - Door 1 Contact MIFARE Reader w/PINPad
OUT 2 Non-supervised - Door 1 REX MIFARE Reader w/PINPad
OUT 3 Non-supervised - Door 2 Contact - Lenel OpenProx
OUT 4 Non-supervised - Door 2 REX - Lenel OpenProx
Lenel Access Hardware Demo System User Guide 19
Configuration
20
Local I/O Setup for Auxiliary Inputs and OutputsSystem Administration > Access Control > Local I/O
Local I/O Function List Tab
Device > Function Links Tab
Lenel Access Hardware Demo System User Guide
Card Formats
Card FormatsSystem Administration > Administration > Card Formats
Card Format Tab for OpenProx Format (36-Bit), All Readers
Card Format Tab for FASC-N (200-Bit) HID OSDP and MIFARE Reader with PINPad
Lenel Access Hardware Demo System User Guide 21
Configuration
22
Card Format Tab for FASC-N (75-Bit) HID OSDP Reader and MIFARE Reader with PINPad
Card Format Tab for Lenel OpenCard Format (36-Bit), All Readers
Lenel Access Hardware Demo System User Guide
Card Formats
Card Format Tab for Magnetic Format, Not Assigned
Card Format Tab for SEWIG (Access Control), Not Assigned
Lenel Access Hardware Demo System User Guide 23
Configuration
24
Custom Encoding Tab for SEWIG (Access Control), Not Assigned
Card Format Tab for SEWIG GSC (Encoding), Not Assigned
Lenel Access Hardware Demo System User Guide
Card Formats
Custom Encoding Tab for SEWIG GSC (Encoding), Not Assigned
Card Format Tab for OSDP Format (26-Bit), All Readers
Lenel Access Hardware Demo System User Guide 25
Configuration
26
GroupsSystem Administration > Access Control > Groups
Mask Groups Tab
Enabling User Commands/Extended Hold OptionsSystem Administration > Administration > System Options
User Commands Tab
Command Keypad TemplatesSystem Administration > Access Control > Command Keypad Templates
Lenel Access Hardware Demo System User Guide
Command Keypad Templates
Macro Assignments Tab
User Feedback Tab
Lenel Access Hardware Demo System User Guide 27
Configuration
28
Default Mask Group Intusion Commands Tab
Any Mask Group Intrusion Commands Tab
Lenel Access Hardware Demo System User Guide
Command Programming Assignment (HID OSDP Reader)
Command Programming Assignment (HID OSDP Reader)System Administration > Access Control > Readers and Doors
Command Programming Tab
Lenel Access Hardware Demo System User Guide 29
Configuration
30
Lenel Access Hardware Demo System User GuideAPPENDIX A Configuration Overview
This appendix provides the Lenel Access Hardware Demo Case configuration parameter settings.
Lenel Access Hardware Demo System User Guide 31
32
ISC Communication Parameters
ISC Setup Parameters
Single Reader Interface
Parameter Setting
Workstation <your workstation name>
IP address 192.168.0.251
Baud rate 38400
Memory 16 MB
Connection type LAN
Panel Address 0
Online YES
Parameter Setting
Number of cardholders 500
Options None
Store activate date YES
Store deactivate date YES
PIN Type 1-4 digit PIN
Store anti-passback location
NO
Parameter Setting
Reader name HID OSDP Reader
Type Single interface (OSDP Protocol)
Port 2
Address 31
Reader number 0
Online mode Pin or card
Offline mode Pin or card
Allow user commands YES
Lenel Access Hardware Demo System User Guide
Single Reader Interface
Allow intrusion commands
YES
Held open time (sec) 20
Extended open (sec) 75
Strike time (sec) 10
Extended strike (sec) 25
Elevator reader NO
Card formats AWID Format, FASC-N 200 Bit, FASC-N 75 Bit, Lenel Corporate Format, Wiegand Format (26-Bit)
Pin format Eight bit output keypads
Parameter Setting
Lenel Access Hardware Demo System User Guide 33
34
AUX Output 1
Dual Reader Interface
Reader 1
Parameter Setting
Name Armed
Pulse time 5 seconds
Activate during time zone
None
Parameter Setting
Reader name MIFARE Reader w/PINPad
Type IDRC Onboard Reader 1 (Mag w/ Wiegand Output)
Port
Address 0
Reader number 0
Online mode Pin or card
Offline mode Pin or card
Allow user commands YES
Allow intrusion commands
YES
Held open time (sec) 20
Extended open (sec) 75
Strike time (sec) 10
Extended strike (sec) 25
Elevator reader NO
Card formats AWID Format, FASC-N 200 Bit, FASC-N 75 Bit, Lenel Corporate Format, Wiegand Format (26-Bit)
Pin format Eight bit output keypads
Lenel Access Hardware Demo System User Guide
Dual Reader Interface
AUX Input 1
AUX Output 1
AUX Input 2
Parameter Setting
Name MIFARE Reader w/ PINPad
Input 1 Door
Input ID 1
Contact normally open YES
Online YES
Always mask NO
Mask during time zone None
Entry delay 10
Exit delay 10
Non-latch entry NO
NOT SUPERVISED
Parameter Setting
Name Door
Pulse time 5 seconds
Activate during time zone
None
Parameter Setting
Name MIFARE Reader w/ PINPad
Input 2 Window
Input ID 2
Contact normally open YES
Online YES
Always mask NO
Mask during time zone None
Entry delay 0
Exit delay 0
Lenel Access Hardware Demo System User Guide 35
36
Reader 2
Non-latch entry NO
NOT SUPERVISED
Parameter Setting
Reader name Lenel OpenProx
Type IDRC Onboard Reader 2 (Wiegand/Prox)
Port
Address 0
Reader number 1
Online mode Card only
Offline mode Card only
Allow user commands NO
Allow intrusion commands
NO
Held open time (sec) 20
Extended open (sec) 75
Strike time (sec) 10
Extended strike (sec) 25
Elevator reader NO
Card formats AWID Format, Lenel Corporate Format, Wiegand Format (26-Bit)
Pin format No keypad
Parameter Setting
Lenel Access Hardware Demo System User Guide
Dual Reader Interface
AUX Input 1
AUX Output 1
AUX Input 2
Parameter Setting
Name Lenel OpenProx
Input 3 Motion
Input ID 3
Contact normally open YES
Online YES
Always mask NO
Mask during time zone None
Entry delay 0
Exit delay 0
Non-latch entry NO
NOT SUPERVISED
Parameter Setting
Name Alarm
Pulse time 5 seconds
Activate during time zone
None
Parameter Setting
Name Lenel OpenProx
Input 4 Reset
Input ID 4
Contact normally open YES
Online YES
Always mask NO
Mask during time zone None
Entry delay 0
Exit delay 0
Lenel Access Hardware Demo System User Guide 37
38
Non-latch entry NO
NOT SUPERVISED
Parameter Setting
Lenel Access Hardware Demo System User Guide
APPENDIX B Demonstration Scenarios
Valid User Presents Card to ReaderSwitch tip will light up green depicting a door strike. User toggles the corresponding door switch to trigger a simulated contact break in a typical door open/close scenario.
User Presents Invalid Badge to ReaderDoor LED tipped toggle switch will not light up. When presented to the HID OSDP reader, user will see "Access Denied" on the LCD screen.
Valid User Arms the System• Armed LED will illuminate. At this point, a motion, window or door switch under the left wing
will illuminate an Alarm LED.
Note: IN1 (Door) has an entry and exit delay of 10 sec.
• Any user can use the F3 key on the HID OSDP reader to view faulted zones.• Any user with valid access can use the F4 key on the HID OSDP reader to enable extended hold
on Door1.• When the system is armed and an output(s) is activated, the Reset button (IN4) will deactivate all
of the outputs except the Armed output.• By default, upon power up, the system is in an Armed state.
Lenel Access Hardware Demo System User Guide 39
40
Lenel Access Hardware Demo System User GuideAPPENDIX C Wiring Diagram
Refer to the Figure 1 on page 42 if you need to remove and replace the Demo Case modules.
Lenel Access Hardware Demo System User Guide 41
42
FIGURE 1. Demo Case Wiring Diagram
Lenel Access Hardware Demo System User Guide
Lenel Access Hardware Demo System User Guide 43
UTC Fire & Security Americas Corporation, Inc.1212 Pittsford-Victor RoadPittsford, New York 14534 USATel 866.788.5095 Fax [email protected]