Steve LennonDivisional ExecutiveEskom
2011 Summer SeminarAugust 1, 2011
Advances in Dry Cooling Deployed at South African Power Stations
3 2011 Electric Power Research Institute, Inc. All rights reserved.
Eskoms Move to Dry-Cooling
Eskom historically utilized wet-cooled power stations
In 1966 it was decided to extend Grootvlei Power Station 3 factors had to be considered:
Growing demand for electrical power
Opportunity to exploit coal fields
Obligation to optimize the utilization of water
Eskom strategy:
Add generation capacity without increase in water consumption
Gain experience in dry-cooling
4 2011 Electric Power Research Institute, Inc. All rights reserved.
Eskoms Pioneer: Grootvlei PS
Grootvlei Unit 5 and 6 added dry-cooled
Unit 5: Indirect system with spray condenser and dry cooling tower
Unit 6: Indirect system with surface condenser and dry cooling tower
Largest dry-cooling units in the world at the time
5 2011 Electric Power Research Institute, Inc. All rights reserved.
Matimba Power Station (6 x 665 MW)
Design: Known turbine characteristics, energy output was maximized over given ambient temperature range
Average back pressure: 18.6 kPa
LP turbine protection: 65 kPa
Average steam velocity 80 m/s at 18.6 kPa
Station orientated with prevailing wind direction towards boiler
2 x 5 m exhaust ducts
ACC details per unit
48 fans, 10 m diameter
8 streets with 6 fans per street
Street length 70.8 m
12 MW auxiliary power consumption
Total platform footprint 35 700 m2
6 2011 Electric Power Research Institute, Inc. All rights reserved.
Matimba Power Station Finned-Tubes
Oval tube and rectangular fin design
2.5 and 4mm fin pitch in 2-row staggered bundles
Carbon steel tubes with carbon steel punched fins, then hot dip galvanized
7 2011 Electric Power Research Institute, Inc. All rights reserved.
Kendal Power Station (6 x 686 MW)
Surface condenser with SS tubes
Circulating water flow: 16.8 m3/s
Galvanised heat exchanger tubes
11 sectors which can be individually isolated
Total of 1 980 km of finned tube/tower
Horizontal, radial arrangement
Tower dimensions
Diameter at tower base 144 m
Total height 165 m
Thermal design
Known turbine characteristics, energy output was maximized over given ambient temperature range
3.4 MW auxiliary power consumption/unit
8 2011 Electric Power Research Institute, Inc. All rights reserved.
Majuba Power Station (3 x 657 MW)
Average back pressure: 16.6 kPa
LP turbine protection: 70 kP
Station orientated with prevailing wind direction towards boiler
2 x 5.5 m exhaust ducts
ACC details per unit
48 fans, 10 m diameter
8 streets with 6 fans per street
45 m air inlet opening
8.2 MW auxiliary power consumption
Total platform footprint 20995 m2
Finned-tube design similar to Matimba
9 2011 Electric Power Research Institute, Inc. All rights reserved.
Eskom Specific Water Consumption Trend
0
2000
4000
6000
8000
10000
12000
1965 1970 1975 1980 1985 1990 1995 2000 2005 2010
Year
MW
0
0.5
1
1.5
2
2.5
l/kW
h
Total installed dry cooled capacity
Specific water consumption, l/kWh
Coal-fired power stations
2010 specific water consumption value = 1.38 l/kWh generated
10 2011 Electric Power Research Institute, Inc. All rights reserved.
Design Efficiency of Eskom Power Stations
30%
32%
34%
36%
38%
40%
42%
Dry Cooled Wet Cooled Dry and Wet Cooled
11 2011 Electric Power Research Institute, Inc. All rights reserved.
Specific Water Consumption at Power Stations
0
500
1000
1500
2000
2500
litre
s/M
Wh
Dry Cooled Wet Cooled Dry and Wet Cooled
12 2011 Electric Power Research Institute, Inc. All rights reserved.
Cost of Dry vs. Wet Cooling
Cooling system choice to be based on life cycle costing including capital, O&M, plant output and cost of water
Relative costs for wet and dry indirect cooling systems in 1996:
Capital cost of dry system was approximately 170% of wet system cost (surface condenser)
More than 1% reduction in average unit output for dry system
Footprint of dry natural draft cooling towers is typically 300% of that of a wet cooling tower of comparable size
Challenge for retrofitting dry cooling systems is capital costs
13 2011 Electric Power Research Institute, Inc. All rights reserved.
Medupi Power Station (6 x 794 MW)
Average back pressure: 14.1 kPa (at 9m/s wind)
LP turbine protection: 75 kPa (a)
Average steam velocity approximately 78 m/s at 14.1 kPa (a)
Station orientated with prevailing wind direction towards boiler
2 x 6.2 m exhaust ducts
ACC details per unit
64 fans, 11m diameter
8 streets with 8 fans per street
Street length 108 m
Approximately 52 m air inlet opening
12.4 MW auxiliary power consumption
Total platform footprint 72252 m2
14 2011 Electric Power Research Institute, Inc. All rights reserved.
Medupi Progress Boiler 6 and Boiler 5
15 2011 Electric Power Research Institute, Inc. All rights reserved.
Medupi Air-Cooled Condensers Under Construction
16 2011 Electric Power Research Institute, Inc. All rights reserved.
Kusile Power Station (6 x 800 MW)
Average back pressure 11.55 kPa (at 9 m/s wind)
LP turbine protection: 75 kPa
Average steam velocity approximately 83 m/s at 11.55 kPa
Station orientated with prevailing wind direction towards boiler
2 x 6 m exhaust ducts
ACC details per unit
64 fans, 11 m diameter
8 streets with 8 fans per street
Street length 100.1 m
Approximately 58 m air inlet opening
12.4 MW auxiliary power consumption
Total platform footprint 66052 m2
17 2011 Electric Power Research Institute, Inc. All rights reserved.
Operational Experience: Majuba Unit 1 Trip During Unsteady Wind Period
Majuba Unit 1 vacuum trip
13 November 2004
0
10
20
30
40
50
60
70
80
90
100
2004/11/13
14:49
2004/11/13
14:57
2004/11/13
15:04
2004/11/13
15:11
2004/11/13
15:18
2004/11/13
15:25
2004/11/13
15:33
2004/11/13
15:40
Time
Te
mp
era
ture
, P
ress
ure
, %
0
50
100
150
200
250
Am
p
Generator Output, %
ACC Pressure, kPa (abs)
Steam temperature, C
Air Inlet Temperature, C
Fan motor current, Amp
Air Cooled Condenser
Turbine
Boiler
2
Boiler
3
Boiler
1
Wind
direction
during trip
2
18 2011 Electric Power Research Institute, Inc. All rights reserved.
Future Role of Dry Cooling
Key technology in South Africas climate change impact adaptation strategy
All future coal plants will be dry cooled
Application to other technologies being evaluated especially solar thermal
18
19 2011 Electric Power Research Institute, Inc. All rights reserved.
TogetherShaping the Future of Electricity