LEROY CRANDALL & ASSOCIATES
CONSULTING FOUNDATION ENGINEER S
1619 BEVERLY BOULEVARD • LOS ANGELES 26, CALIFORNIA
MAdi .on 9-3661
October 30, 1963
L. LEROY CRANDAJI . . C. E.
PREDUCZ A. )AANES
LEOTOLD Hzmcw ELDT
MJUELL C . WEIER. C. E.
J. D. YIRLOARD. C. E .
JAJAES N . )C WER. C.R.
Rocketdyne -A Division of North American Aviation, Inc .
6633 Canoga Avenue P.O. No . X310FZ-801064
Canoga Park, California (Our Job No . 63545)
Attention : Mr . K. Stafford
Department 58 3
Gentlemen :
Our "Report of Soils Investigation, Test Stand Delta 2 Area,
PFL, Santa Susana, California, for Rocketdyne - A Division of North
American Aviation, Inc ." is herewith submitted .
Specifications for the investigation were furnished to us bypersonnel of your staff, and these specifications and the requirements
of your Purchase Order No . X310FZ-801064 were followed in completing
the investigation .
Respectfully submitted ,
LeROY CRANDALL & ASSOCIATES
LC-JK/gb(6 copies submitted)
BNA03985034
HDMSe00181436
LEROY CRANDALL ar ASSOCIATE S
REPORT OF SOILS INVESTIGATION
TEST STAND DELTA 2 AREA
PFL, SANTA SUSANA , CALIFORNIA
FOR
ROCKETDYNE -
A DIVISION OF NORTH AMERICAN AVIATION, INC .
SCOPE
This report presents the results of an investigation of the soi l
conditions in the Test Stand Delta 2 area . The area under consideration
and the locations of our borings are shown on Plate 1, Plot Plan .
Our investigation was to consist of two parts :
1 . We were requested to obse rve the drilling of Boring 1 which
was located southwest of Delta 2 as shown on Plate 1 . This boring was to
be drilled by others , and we were to furnish a log of the soils encountered .
2 . W-e were requested to drill three borings at the location of
the proposed combustor . The desired locations and depths of the borings
were specified by Rocketdyne ; however , the boring locations had to be modified
slightly due to difficulties of access with the drilling equipment . Based
on these three borings, recommendations for design of drilled cast-in-place
concrete piling were to be established .
EXPLORATIONS
Bor ing 1
Boring 1 was actually a 36-inch-diameter drilled pile excavation
which extended to a depth of 24 feet . The excavation was made by blasting ,
BNA03985035
HDMSe00181437
Page 2 LEROY CRANDALL & ASSOCIATE S
and we did not observe the excavation process . However, the excavation was
entered by our field engineer who made a log of the materials from visual
examination . The boring log is presented on Plate 2-A . The materials ob-
served consisted of sandstone which was weathered and fractured to a depth
of seven feet ; below the seven- foot depth , the sandstone was observed to be
massive and less fractured . The exposed sandstone surface in the excavation
was very rough due to the blasting . Reportedly , the excavation was deepened
to 30 feet after our inspection .
Borings 2, 3, and 4
Borings 2, 3, and 4 were each drilled to a depth of roughly 40 feet .
The borings were extended through the existing fill and overburden soils
with five-inch-diameter vacuum rotary equipment ; three-inch-diameter coring
equipment was used to extend the borings into the underlying sandstone . The
borings were logged by our field engineer . The boring logs are presented on
Plates 2-B, 2-C, and 2-D . The existing fill soils and overburden soils are
classified in accordance with the Unified Soil Classification System'shown
on Plate 3 .
Undisturbed samples of the existing fill and overburden soils were
obtained at frequent intervals of depth for laboratory inspection and testing .
The depths at which undisturbed samples were obtained are indicated to the
left of the boring logs in accordance with the Key on Plate 2-A . Continuous
cores were obtained during the coring operations in the underlying sandstone .
The percentage of core recovery is indicated to the left of the boring logs,
also in accordance with the Key on Plate 2-A . The percentage recovery
figures in Borings 3 and 4 are relatively low due to improper functioning of
the core barrel . The drilling or coring was firm throughout the sandstone ,
BNA03985036
HDMSe00181438
Page 3LEROY CRANDALL & ASSOCIATE S
and the poor recovery was not due to the condition of the sandstone rock .
Based on Borings 2, 3, and 4 , the combustor area is underlain by
existing fill ranging from 9 to 33 feet deep . The fill, which consists of
silty sand with large sandstone cobbles and boulders , is variable but generally
moderately firm . The fill is underlain by silty sand overburden soils and
sandstone . The overburden soils are moderately firm to firm at present
moisture content but would become weaker and more compressible when wet .
The underlying sandstone is firm to ve ry firm and hard .
LABORATORY TESTS
The field moisture content and dry density of the existing fill
and overburden soils were determined by testing the undisturbed samples .
The test results are shown to the left of the boring logs in accordance
with the Key on Plate 2-A . Unconfined compression tests were performed on
core samples of the sandstone obtained from Boring 2 . The resulting test
data are presented on Plate 4 , Unconfined Compression Test Data .
CONCLUSIONS
The downward and upward capacities of single cast - in-place concret e
piles are presented on Plate 5 , Friction Pile Capacities . The capacities
are presented as a function of penetration into the underlying sandstone rock
and represent the resistance to the total of all applied loads ; no increase
in the capacities are recommended for temporary loadings . Because of the
remote possibility of adverse joint structure , which could reduce the up-
ward capacity of the piles , a minimum penetration of ten feet into the sand-
stone rock is recommended .
For resisting lateral loads , batter piles may be used . The axial
capacities of batter piles , not exceeding a batter of 1 horizontal to 4 vertical ,
BNA03985037
HDMSe00181439
page4 LEROY CRANDALL & ASSOCIATE S
may be assumed to be equal to the downward and upward pile capacities presented
on Plate 5 .
The capacities presented on Plate 5 are for single piles . Founda-
tions supported on groups of piles, especially those foundations subjecte d
to upward or lateral loads , should be analysed to assure the overall stability
of the piles and the sandstone mass in which the piles are installed . Such
analyses will depend on the number and spacing of the piles and the magnitude
and direction of the applied loads .
The installation of piles into the sandstone will require special
coring equipment or blasting which was done for pile foundations located
southwesterly of Delta 2 . Because of th e caving nature of the overlying
fill, piles should be spaced a minimum of 2k diameters on centers . Also,
closely-spaced piles should be excavated and filled alternately with the
concrete permitted to set at least eight hours before excavating for an
adjacent pile . We would suggest that all pile excavations be inspected to
assure the desired penetration into the sandstone rock . Also, the sandstone
should be carefully inspected for possible adverse jointing which might require
modification of the foundation design .
-000-
The following Plates are attached and complete this report :
Plate 1 . . . . . . . . . . Plot Plan
Plates 2-A through 2-D . . Logs of Boring s
Plate 3 . . . . . . . . . . Unified Soil Classification System
Plate 4 . . . . . . . . . . Unconfined Compression Test Data
Plate 5 . . . . . . . . Friction Pile Capacities
BNA03985038
HDMSe00181440
N 20,550
N 20,500
N 20, 450
BORING NO .ELEV OF SURFAC EOF SANDSTONE ROCK\ I ,
(1789)
1760
7
71765
-1770
\ v \ \ ~\v v~~ rc A V A 11
00
REFERENCEPLOT & GRADING PLAN (PRINT DATED 8-27-63)
BY ROCKETDYNE
/775
V \~
COMBUSTO R
1(1747)2 \~V 04
1780
\\ 4
- ~1790 y\ BORING LOCATION S
BORING COORDINATES
NUMBER NORTH I EAST
1 20,430 14,295
2 20,525 14,390
3 20,535 14,39 5
4 20 520 1440 5,
B .M - LEAD & TACK NW CORDELTA PRE-TEST BUILDING
ELEV 1799 .2 1
P L O T P L A NSCALE =2 0
L{ Ro G~~":~~__ ASSOCIATES
LOG OF BORING 1
36"-Diameter Shaft Excavated using Explosive s
Inspected August 7, 196 3
1790-
0
1785-
5°W
V-1
uC)
1780-a10
rr.
C
° 1775 -
u 15
qj
ro
c
-+1770 -
W
2 0
n
1765-
25
6 .81-1051
1 L
Indicates coring run
Percentage of core recovery
Indicates depth at which undisturbedsample obtaine d
Dry density in pounds per cubic foot
Field moisture content in percent of
dry weight
*See Plot Plan for location and elevation of benchmark .
L Z R_ C<Ati :;A-_ & ,A55--_ 1 T E S
I I
Elevation 1788 .8*
CONCRETESANDSTO: . - fractured, light yellowish-
brown
Massiv e
NOTE : Groundwater not encountered ; no caving .
Hole battered 1/12 :1 (horizontal to
vertical) . Hole reportedly deepened to
3J' but not inspected below 24' .
KEY :
PATE 2- A
uuuuiuiiiu iBNA03985040
HDMSe00181442
LOG OF BORING 25"-Diameter Vacuum Rotary Hole to 25 '
3"-Diameter NWX Core Boring below 25'
Drilled August 14 & 15, 196 s
1780 - n Elevation 1779 . 7
FILL - SILTY SAND - fine, dark brown
1775-
1770-
Boulder
1750-
Some gravel
Organic layer
Boulder
1760-
1745-
LW
•+ 20Well graded, few gravel
Fine
1740-
Few cobbles and boulders
SANDSTONE - fractured, 1io : .t yellowish-
bruwn
10
30
35
4u
More fractured, lenses of SHALE
NOTE : Groundwater not encountered ; no caving . .
LEROI C,,A\".ALL :r ASSGC ATE S
I IPLATE 2-D-
uuuuiuiiiu iBNA03985041
HDMSe00181443
LOG OF BORING 3
5"-Diameter Vacuum Rotary Eole to 12 '
3"-Diameter NWX Core Boring below 1,~'
Drilled August 19, 196 3
1780 -
0
1775 -7 .9%-11 1
8 .3%-109
1770-
10
4J
0 1765 -WW
L
514%
at
w
1760-
20V 23 /
0
1755 -
ro +
2 5v 50%
1750-
30 73:
1745-
35
3e%
1740-
40
Elevation 1777 . 9 '
FILL - SILrY s .aND - fine, some gravel and
c:)bbl2 ., ; :httled brown
Few gravel , dark brow n
SANDSTONE - fractured, light yellowish-brown
Less fractured
Thinly bedded, yellowish-brown
Lens of SHALE - brown
Harder, light yellowish-brown
NOTE : Groundwater not encountered ; no caving .
Poor core recove ry caused by
rotation of inner tube. ROY
PLATT 2- C
I I uuuuiuiiiu iBNA03985042
HDMSe00181444
LOG OF BORING 4
5"-Diameter Vacuum Rotary Hole to 33 '
3"-Diameter NSdX Core Boring below 33'
Drilled Augu.,t 15 & 16, 1963
Elevation 1781 . 9
1780-
1775-
d)
14-4
1770-
z 1765 -
755 -W 1755-
1750 -1750-
1745-1745-
Fein gravel and cobblesFew
SANDSTONE - fractured, light yellowish-brown
Massive
1740 - 0' to 31' .
NOTE : Slight water seepage encountered at
26' ; slight raveling in layers from
L-R1 C <Ah.D ALL Er AS"D _ . .r --- s
PLATE 2-D
I I uuuuiuiiiu iBNA03985043
HDMSe00181445
MAJOR DIVISIONSGROUP TYPICAL NAME SSYMBOLS
'co7~'b
GW
Well graded grovels , gravel-sand mixtures ,
CLEAN ; little or no fines .
GRAVELS(Little or no fines) GP Poorly graded grovels or grave sand mixtures ,
GRAVELS Ittle or no fines .
(More than 50% ofcourse fraction i sLARGER than the GM Silty gravels , gravel- sand - sill mixtures.No . 4 sieve size) GRAVELS
WITH FINE S
COARSE (Appreciable amt .of fines)
GC Clayey gravels , gravel -sand - clay mixtures .
GRAINE DSOILS
(More than 50 % ofS W
Well graded sands , grave ll y sands , li tt le or
material is LARGER no finesthan No . 200 sieve CLEAN SAND Ssize)
(Little or no fines ) Poorly graded sands or gravelly sands , littl e
SANDS SP or no fines .
More than 50 % ofcoarse fraction i sSMALLER than the SM Silty sands, sand silt mixtures .No . 4 sieve size) SAND S
WITH FINES( Appreciable amt .
of fines) SC Clayey sands , sand - clay mixtures .
Inorganic sllts and very fine sands, rock flour ,ML silty or clayey fine sands or clayey silt s
with slight plasticity .
SILTS AND CLAYS Inorganic clays of low to medium plasticity ,
(Liquid limit LESS than 50) CL gravelly clays , sandy clays , silty clays, lea nclays .
FINE OLsilts and organic s il ty clays of lo wOrganic
cGRAINE D
SOIL S(More than 50 % of MH Inorganic silts , micaceous or diatomaceou s
material is SMALLER fine sandy or silty soils, elastic s il ts .than No . 200 siev esize)
SILTS AND CLAYSCH inorganic clays of high plasticity, fat clay s
(Liquid limit GREATER than 50)
OHOrganic clays of medium to high plasticity ,organic silts .
HIGHLY ORGANIC SOILS Pt Peat and other highly organic soils .
BOUNDARY CLASSIFICATIONS : Soils possessing charocter ,stics of two groups are designated bycombinations of group symbols .
P A R T I C L E S I Z E L I M I T S
SILT OR CLAY
SAND GRAVE LVEL
COBBLES I BOULDERS
CDAR S EFINE IFIN E
NO. 200 NO. 40 NO. 10 NO.4 3/qe. 3.n .
'J . S . S T A N D A R a S I E V E S I Z E
(I in )
UNIFIED SOIL CLASSIFICATION SYSTE M
ReferenceThe Unified Soil Classification System , Corps o f
Engineers , U . S . Army Technical Memorandum No h-357,
Vol I, March, 1953 . (Revised April, 1960)LEROY CRANDALL & ASSOCIATE S
I IPLATE 3
BNA03985044
HDMSe00181446
BORING
NUMBER
SAMPLEDEPTH(FEET) SOIL TYPE
2 35 Sandstone 2,000
2 36 Sandstone 1,600
2 38 Sandstone 2,200
UNCONFINED COMPRESSION TEST DATA
~r <~, Cr<AN ~. ASSOJ RTE S
PLATE 4
BNA03985045
HDMSe00181447
DOWNWARD PILE CAPACITY in Kip s
150 300 450 600
1 0
15
2 0
25
750
CAST-IN-PLACE CONCRETE
FRICTION PILE S
MINIMUM RECOMMENDEDPENETRATIO N
Ig 224
Pile Diameter
in Inche s
li I
0 100 200 300 400
UPWARD PILE CAPACITY in Kips
500
NOTES : (1) The indicated capacities are for the total of all loads including
temporary loads .
(2) The indicated capacities may be used for the axial capacities
of battered piles for batters not exceeding 1 ttorizontal to 4 vertical .
(3) The capacities are based on the strength of the sandstone . The
strength of the piles may limit the capacities to lower values .
(4) The indicated capacities are for single piles . The stability
of foundations supported by pile groups and the sandstone mass supporting
tne pies should be caecked .
(5) Because of t :ie potential caving of the overlying fill, piles
should be spacea at least 2z diameters on centers and should be excavated
and filleu aiceraatei) aliuwinb the concrete to set at least 8 hours before
excavating an adjacent hole .
FRICTION PILE CAPACITIES
nLATE 5
I I uuuuiuiiiu iBNA03985046
HDMSe00181448