LG Commercial Air Conditioners 2010Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.
• Weekly Program
• Turbo Fan
• High Head Drain Pump
• Low Standby Power
• Auto Restart
• Central Controller(Accessory)
• Group Control
• Child Lock Function
• Two Thermistor Control
• Auto Changeover
• Long & High Elevation Piping
• Hot Start
• Zone Control (Optional)
• Wireless Remote Controller
• Jet Cool
• Auto Operation
• 7-Hour OFF Setting Timer
• 24-Hour ON/OFF Setting Timer
• Duct Operation
Features _ icon
Comfort Everyone in a Greener WayPursuing a more comfortable life in today’s complicated society has become second nature. However, we cannot afford to compromise the health of the environment for our own personal comfort. In order to achieve a balance between these two needs, LG provides products and solutions for those who seek comfortable lives in a greener way; comfort and eco-friendliness are our key values.
We at LG create optimal living and working conditions by enabling our customers to control their environment: including temperature, humidity and air quality to make them more comfortable. LG products are safe to operate and easy to manage and we provide our business partners with reliable and cost-effective solutions. Customer satisfaction motivates us to work closely and productively with our partners and we also offer a comprehensive after-sales and one-stop service system.
LG is committed to protecting our environment by enhancing the energy efficiency of our products and our business operations by adhering to eco-friendly principles. LG has been significantly investing in R&D and pursuing continuous innovation to enhance product energy efficiency. LG uses eco-friendly refrigerants in its air conditioners, which help save the ozone layer and all LG’s products are produced under an ‘Eco-Design’ system, which ensures environmentally-friendly processes from production to disposal.
LG is fully committed to making the lives of our customers more comfortable in an environmentally sustainable way and we strive to ensure our business partners benefit from partnering with us. Our commitment and innovation enable us to uphold our key values - Green and Comfort. With commitment and innovation, we comfort everyone – our business partners and customers – in a greener way.
Energy Efficiency Class ofThe Unit In Cooling Mode :
Energy Efficiency Class ofThe Unit In Heating Mode :
‘ E c o - D e s i g n , E ne r g y E f f i c i e n t , R ed u c e C O2 E m i s s i o n s ‘
LG Air Conditioners 2010 02 _03
Enjoy Clean, Quiet, and ComfortableAir Conditioning with LG
Ceiling Cassette Type
kWType 3.5 5.0 6.0 7.1 8.0 10.0 12.5 14.0(13.4*) 15.0
UT12 NRD
UT12H NP1 UT18H NP1 UT21H NN1 UT24H NN1 UT36H NM1 UT42H NM1 *UT48H NM1
2.5
UT09 NRD UT18 NQD UT24 NPD UT30 NPD UT36 NND UT42 NMD UT48 NMD UT60 NMD
UB18 NHD
UB18H NG1 UB21H NG1 UB24H NG1 UB36H NR1 UB42H NR1 *UB48H NR1
UB24 NHD UB30 NGD UB36 NGD UB42 NRD UB48 NRD UB60 NRD
UV12 NEDUV09 NED UV18 NBD UV24 NBD UV30 NBD UV36 NKD UV42 NLD UV48 NLD UV60 NLD
Ceiling Cassette Type
Ceiling Concealed Duct Type
Ceiling and Floor Type
CQ12 NA0CQ09 NA0
*Only Connectable to DC Inverter
CQ18 NA0
Console Type*
Universal Indoor Type
8.0kW kWType Type14.0 14.021.1 21.132.8
Floor Standing Type
Ceiling Concealed Duct Type
Set Type Set Type
kWType 3.52.5 5.0 6.0 7.1 8.0 10.0 12.5 14.0(13.4*) 15.0
H-Inverter
Heat Pump
DC Inverter
3Phase DC Inverter
Universal Outdoor Type
UU12 ULD
UU18WH UE1UU12WH UE1
UU18 UED
UU24WH U41
UU24 UED
UU36WH U31
UU37 UEDUU30 UED
UU42WH U31 *UU48WH U31
UU48 U3D UU60 U3D
UU12W ULDUU09W ULD UU18W UED UU24W UED UU36W UED UU42W U3D UU48W U3D UU60W U3DUU30W UED
UU37W UED UU49W U3D UU43W U3D UU61W U3D
B120AH SV0
P03AH SR1 P05AH ST0 P08AH SF1
UU21WH U41
ACEACE InverterInverter
Inverter
InverterInverter
Inverter
Inverter
Inverter
A B C D
A B C D E
Inverter
Inverter
Improved COP and Energy Saving
With the advancement of inverter technology comes more silent, economical and powerful air conditioning systems.
Improved COP / EER
Comfort Operation with DC Inverter Technology
Wide Operating Range
Easy to Service
Energy efficiency of DC inverter models is significantly improved compared with Heat pump models
When the air conditioner is initially activated to either heat or cool, the compressor will operate at maximum speed to reach the desired temperature quickly. Once the desired temperature is achieved,unlike conventional air conditioners that turn the compressor on and off, LG inverter units constantly adjust and vary the compressor speed to mainta in the des i red temperature with minimal fluctuation to ensure that your comfort is not compromised.
When cooling computer rooms and other rooms in the event of low outdoor temperatures, the BLDC inverter compressor and outdoor BLDC fan motor are used to adjust the air flow and volume, with a view to ensuring efficient operation by allowing the air conditioner to keep operating at -10°C without turning it off.
DC Inverter
Easy & efficient installation of outdoor unit will provide the best solution for small offices and shops.
Noi
se L
evel
[dB
(A)]
Day time Night Silent
52
2.53
2.66
55
4647
*UU12WH~
UU24WHUU36WH
~UU48WH
*UU12WH~
UU24WHUU36WH
~UU48WH
3.00
3.50
4.00
4.50
5.00
5.50
(UB18 + UU18W)DC Inverter Model
DC Inverter
ACE Inverter
(UB18 + UU18)Heat Pump Model
COP Improved by 37%
32
150
* Power Consumption(W)Noise Level [dB(A)]
Inverter heat pumpSetpoint
Tempetature
Non-inverter heat pump
TimeTem
per
atur
e
On
On On OnOff Off Off
3 pieces of screw
Ez SVC
1. Inner SVC valve- 4 Way piping is possible (Front, Rear, Right, Down)- Excellent exterior
4 way1 way
2. Convenient moving handle- Fitted hand grips for easy transportation and installation
3. Compact Design & Ez SVC- Remove 3 pieces of screw for SVC- Front panel removal system
1
2 3
Inverter Heat Pump
Ind
oo
r Te
mp
(˚C)
Outdoor Temp(˚C)
10
18
30
32
-15
21
-10 21 35 43
Cooling
Heating
Low AmbientControl
LG Air Conditioners 2010 12 _13
LG "Ceiling Cassette" is a indoor unit which is installed for the significant purpose. The ceiling cassette is used for the commercial purpose. It can be installed in various places such as restaurants, hotels, offices and meeting rooms. This unit has nice outlook and is equipped with many special features. It has four vanes for the air circulation in all directions which in turn can maintain even and wide cooling and heating.
Ceiling Cassette
Comfort OperationWide jet Air Flow
Independent Vane Operation
Automatic Vane angle Control
High Ceiling Mode
Improved Low Noise
Improved wide vanes reduce dead bands and provide better air and temperature distribution.
Vane angle control satisfies both users who like direct wind or indirect wind and also reduces cold air draft.
One motor per vane is adopted to control each of four vane independently, freely controlling air current according to situations.
High ceiling mode with phase-control algorithm is possible to apply as high as 4.2m of ceiling.This setting offers a reduction of drought.
• BLDC motor, Low indoor noise with high efficiency turbo fan- Outlet & air flow improved design- Removal of abnormal noise through high efficiency turbo fan- Resonance noise removal by anti vibration design & BLDC motor• Base pan redesigned
LG Cassette LG Cassette
27°C
15°C
t262524232221201918
Even air distribution
80mm Wider!567mm
Conventional Conventional
27°C
15°C
t262524232221201918
Air flow dead zonein 4 corners
487mm
Direct air flow Indirect air flow
New CassetteCurrent
Wind-amount mode
Airflow Variable range70% 90% 100% 110%
28dB28dB
33dB
38 BdB38dB
130%
AACCC MMoottoorrAC Motor
BBBLLDDDCCCCMMMoootttooorrBLDCMotor
Low-Low Low Medium High Power
Variable range of wind of the interior fan motor
Strong design indoor unit Base Pan DECA web structure design
5 : 70º4 : 60º
3 : 50º
0 : 30º
1 : 20º
2 : 40º
Individual vane operation
Individual vane angle control
All vane operation
Air flow rate control
1 Vane, 1 Motor
Ceiling Cassette
Ceiling Cassette
Easy InstallationDetachable Corner Panels
One Touch Panel
Auto Elevation Grille ( Accessory : PTEGM0)
Design to Reduce the Ceiling Stains
The attachable/detachable corner design makes it easy to adjust the hanger during installation and to check leakage in the drain connection pipe.
The simple push-up panel design easily connect the panel with the body, enabling the installer to use his two hands freely.
Easy filter cleaning with elevation grille
- Installed inside main body- Auto horizontal level- 4 points support- Memory for user’s level- Max. 4.5m length
The new outlet design can reduce ceiling contamination from air current flowing along the ceiling.
*Plz refer to the PDB for av ailable model
Attachable/detachable corner design
RefrigantPiping check
Drain leakage check
Hanger adjustHanger adjust
Hanger adjust Drain leakage check
New Cassette
4.5m
Conventional3.5m
4-Point Support Structure
Auto Horizontal Control
Memory for user’s level
Auto bottom detection
STOP
Existing type
Ceilingpollutions
Ceiling
Lover
Product
Ceiling pollutions prevention type
Lover
Product Ceiling
LG Air Conditioners 2010 14 _15
ACEACE
A B C D
A B C D E
Inverter
Inverter
LG Air Conditioners 2010 20_21Ceiling Cassette
Specifications
Heat pump
•UT12•UT18
Specifications
UU37W UU43W / UU49W / UU61W
Nominal Capacity (Rated) Cooling Btu/h kw Heating Btu/h kw Nominal Input (Rated) Cooling kw Heating kw Running Current Cooling /Heating A Power Supply Ø/V/Hz EER Cooling kw/kw COP Heating kw/kw Operational Temperature Cooling °C Range Heating °C Air Flow Rate (H/M/L) CMM CFM Sound Level (H/M/L) dB(A)±3 Dehumidification Rate l/h Dimensions (WxHxD) Body mm(inch) Decorative Panel mm Weight Body kg(lbs) Decorative Panel kg(lbs) Piping Connections Liquid mm(inch) Gas mm(inch)
Indoor Unit
F/P ane l PT-UMC
13,640~34,100~37,550
4.0~10.0~11.0
15,000~37,500~41,250
4.4~11.0~12.1
3.12
3.23
0.6
1 / 220 ~240 / 50
3.21
3.41
-10 ~ 43
-15 ~ 24
24 / 22 / 19
847 / 759 / 671
43/40/37
2.7
840×246×840(33.1×9.7×33.1)
950×25×950(37.4×1.0×37.4)
23.5(51.8)
5(11.0)
9.52 (3/8)
15.88(5/8)
Outdoor Unit
Compressor Type Refrigerant Charge Charge g(oz) Type Fan Discharge Side/Top Noise Level Sound Press,1m dB(A)±3 Dimensions W*H*D mm(inch) Net Weight Outdoor kg(lbs) Piping connection Liquid mm(inch) Gas mm(inch) Power Supply Cable(Includes earth) No.*mm2 Interunit Cable(Includes earth) No.*mm2
Max. Piping Length/Elevation m Power Supply ø,V, Hz Running Current Cooling/Heating A Air Circulation CMM(CFM) Additional Refrigerant Charge (Over 7.5m) g/m
UU37W UEDRotary
2500(88)
R410A
Side Discharge
54/50
870×1060×320 (34.3×41.7×12.6)
80(176)
9.52 (3/8)
15.88 (5/8)
3×2.5
4×0.75
50/30
3 ,380~415 , 50
3.7/3.9
32(1130)×2
45
UU43W U3DRotary
3600(127)
R410A
Side Discharge
55/51
950×1380×330 (37.4×54.3×13.0)
103(227)
9.52 (3/8)
15.88 (5/8)
3×2.5
4×0.75
75/30
3 ,380~415 , 50
4.09/4.28
55(1942)× 2
40
UU49W U3DRotary
3600(127)
R410A
Side Discharge
55/51
950×1380×330(37.4×54.3×13.0)
103(227)
9.52 (3/8)
15.88 (5/8)
3×2.5
4×0.75
75/30
3 ,380~415 , 50
4.98/5.23
55(1942)×2
40
UU61W U3DRotary
3600(127)
R410A
Side Discharge
55/51
950×1380×330 (37.4×54.3×13.0)
103(227)
9.52 (3/8)
15.88 (5/8)
3×2.5
4×0.75
75/30
3 ,380~415 , 50
5.91/5.79
55(1942)×2
40
UT36 NNDPT-UMC
17,060~42,650~46,915
5.0~12.5~13.8
19,108~47,770~52,547
5.0~14.0~15.4
3.89
3.87
0.72
1 / 220 ~240 / 50
3.21
3.61
-10 ~ 43
-15 ~ 24
30 / 28 / 26
1059 / 989 / 919
46/44/40
3.6
840×288×840(33.1×11.3×33.1)
950×25×950(37.4×1.0×37.4)
26(57.3)
5(11.0)
9.52 (3/8)
15.88(5/8)
UT42 NMDPT-UMC
18,700~46,750~51,425
5.48~13.8~15.7
21,840~54,600~60,060
6.4~15.9~17.6
4.58
4.66
0.72
1 / 220 ~240 / 50
3.01
3.41
-10 ~ 43
-15 ~ 24
34 / 32 / 30
1200 / 1130 / 1059
49 / 47 / 43
4.4
840×288×840(33.1×11.3×33.1)
950×25×950(37.4×1.0×37.4)
26(57.3)
5(11.0)
9.52 (3/8)
15.88(5/8)
UT48 NMDPT-UMC
20,200~50,500~55,550
5.92~14.7~16.3
23,200~58,000~63,800
6.8~17.0~18.7
5.63
5.64
0.72
1 / 220 ~240 / 50
2.61
3.01
-10 ~ 43
-15 ~ 24
34 / 32 / 30
1200 / 1130 / 1059
49 / 47 / 43
5.5
840×288×840(33.1×11.3×33.1)
950×25×950(37.4×1.0×37.4)
26(57.3)
5(11.0)
9.52 (3/8)
15.88(5/8)
UT60 NMD
Note : Due to our policy of innovation some specifications may be changed without notification.
3Phase DC Inverter
•UT36•UT42•UT48•UT60
LG Air Conditioners 2010 54_55
70C
ST 4 - Way
Dimensions
5CSL0-05A
*ATNH18GPLED[UT18 NPD] ATNH24GPLED[UT24 NPD]ATNH30GPLED[UT30 NPD]
618
950618
684
840
671
787
500(
Air o
utlet
hole
)
998260
500(Air outlet hole)
4-R20292
734787840
84060 80108
54950
25
204
4065
TP
1
2
3
4 56
7
Ø70
6661.5
8
Model name
Power supplyCooling CapacityHeating CapacityPiping
ConnectionsLiquidGas
Drain(OD/ID)
Ø/V/HzkWkWmmmmmm
*ATNH18GPLED[UT18 NPD]
1 / 200~240 / 50
9.5215.88
32 / 25
ATNH24GPLED[UT24 NPD]
1 / 200~240 / 50
9.5215.8832 / 25
ATNH30GPLED[UT30 NPD]
1 / 200~240 / 50
9.5215.8832 / 25
REFER TO EACH COMBINATION TABLE
No.12345678
krameRemaN traPPT-UMC
Ø70
Decoration panelair suction grilleAir discharge grilleGas pipe connectionLiquid pipe connectionDrain pipe connectionPower supply connectionFresh air connection
6.0/7.0 kW
1. Unit should be installed in complance with the installation manual in the product box.
2. Unit shall be grounded in accordance with the local regulations or applicable national codes.
3. The unit is powered from the outdoor unit. So power cable should be connected with the outdoor unit.
* High efficiency indoor uni.
68C
ST 4 - Way
Dimensions
5CSL0-05A
1.1.3 Dim
ensions
ATNH09GRLED[UT09 NRD]ATNH12GRLED[UT12 NRD]
Model namePower supply
Cooling CapacityHeating CapacityPiping
ConnectionsLiquidGas
Drain(OD/ID)
Ø/V/HzkWkWmmmmmm
ATNH09GRLED[UT09 NRD]1 / 220~240 / 50
6.359.52
32/25
ATNH12GRLED[UT12 NRD]1 / 220~240 / 50
6.359.52
32/25
70047355
380(Air outlet hole)
700
378.
638
0(Ai
r out
let h
ole)
172378.6
4-R20
22.5
570
570
517
150
86
Ø70
517
461
523
214
53
142.530 19
84.5
59.5
570
34.5
4
3
2
1
6
5
CHASSIS CODE: TR2.5/3.5 kW
REFER TO EACH COMBINATION TABLE
No.12345678
krameRemaN traPPT-UQC
Ø70
Decoration panelair suction grilleAir discharge grilleGas pipe connectionLiquid pipe connectionDrain pipe connectionPower supply connectionFresh air connection
8
CST 4 - W
ay 69
Dimensions
5CSL0-05A
ATNH18GQLED[UT18 NQD]
Model namePower supply
Cooling CapacityHeating CapacityPiping
ConnectionsLiquidGas
Drain(OD/ID)
Ø/V/HzkWkWmmmmmm
ATNH18GQLED[UT18 NQD]1/ 220~240 / 50
6.3512.732/25
CHASSIS CODE: TQ5.0 kW
70047355
380(Air outlet hole)
700
378.
638
0(Ai
r out
let h
ole)
172378.6
4-R20
22.5
570
570
517
517
461
523
30 19142.5
95.5125
59.5
570
76 9425
6
4
3
2
1
6
5
REFER TO EACH COMBINATION TABLE
No.12345678
krameRemaN traPPT-UQC
Ø70
Decoration panelair suction grilleAir discharge grilleGas pipe connectionLiquid pipe connectionDrain pipe connectionPower supply connectionFresh air connection
150
86
Ø70
8
787840
60 82 9924
6
80840108 60
6540
25
95073454
500(Air outlet hole)
500(
Air o
utle
t hol
e)61
895
0
4-R20
618292 No.
12345678
krameRemaN traPPT-UMC
Ø70
Decoration panelair suction grilleAir discharge grilleGas pipe connectionLiquid pipe connectionDrain pipe connectionPower supply connectionFresh air connection
1. Unit should be installed in complance with the installation manual in the product box.
2. Unit shall be grounded in accordance with the local regulations or applicable national codes.
3. The unit is powered from the outdoor unit. So power cable should be connected with the outdoor unit.
* High efficiency indoor uni.
1
2
3
4 5 6
7
Ø70 65.579
.5
8
787
671
684
840
Model name
Power supplyCooling CapacityHeating CapacityPiping
ConnectionsLiquidGas
Drain(OD/ID)
Ø/V/HzkWkWmmmmmm
ATNH21GNLED[UT21 NND]
1 / 200~240 / 50
9.5215.8832 / 25
ATNH36GNLED[UT36 NND]
1 / 200~240 / 50
9.5215.8832 / 25
ATNH24GNLED[UT24 NND]
1 / 200~240 / 50
9.5215.8832 / 25
REFER TO EACH COMBINATION TABLE
Model nameATNH42GMLED
[UT42 NMD] 1 / 220 ~240 / 50
9.5215.88
32 / 25
ATNH48GMLEDUT48 NMD]
1 / 220 ~240 / 50
9.5215.88
32 / 25
ATNH60GMLED[UT60 NMD]
1 / 220 ~240 / 50
9.5215.88
32 / 25
684
840
78
787840
0806011840
70 135
148
25 40
183 28
8
95073454
500(Air outlet hole)
500(
Air o
utle
t hol
e)61
895
0 671
4-R20
618292
REFER TO EACH COMBINATION TABLE
1
2
3
4 5
6
7
Ø70
6610
9
8
787
No.12345678
krameRemaN traPPT-UMC
Ø70
Decoration panelair suction grilleAir discharge grilleGas pipe connectionLiquid pipe connectionDrain pipe connectionPower supply connectionFresh air connection
•UT18 NQD•UT09 NRD•UT12 NRD
•UT36 NND•UT21H NN1•UT24H NN1
•UT24 NPD•UT30 NPD•UT12H NP1•UT18H NP1
•UT42 NMD•UT48 NMD•UT60 NMD•UT36H NM1•UT42H NM1•UT48H NM1
Dimensions _ Ceiling Cassette
No. Part Name1 Decoration panel (PT-UQC)2 Air suction grille3 Air discharge grille4 Gas pipe connection5 Liquid pipe connection6 Drain pipe connection7 Power supply connection8 Fresh air connection (Ø70)
No. Part Name1 Decoration panel (PT-UQC)2 Air suction grille3 Air discharge grille4 Gas pipe connection5 Liquid pipe connection6 Drain pipe connection7 Power supply connection8 Fresh air connection (Ø70)
No. Part Name1 Decoration panel (PT-UMC)2 Air suction grille3 Air discharge grille4 Gas pipe connection5 Liquid pipe connection6 Drain pipe connection7 Power supply connection8 Fresh air connection (Ø70)
No. Part Name1 Decoration panel (PT-UMC)2 Air suction grille3 Air discharge grille4 Gas pipe connection5 Liquid pipe connection6 Drain pipe connection7 Power supply connection8 Fresh air connection (Ø70)
No. Part Name1 Decoration panel (PT-UMC)2 Air suction grille3 Air discharge grille4 Gas pipe connection5 Liquid pipe connection6 Drain pipe connection7 Power supply connection8 Fresh air connection (Ø70)
(Unit:mm) (Unit:mm)
(Unit:mm)
(Unit:mm) (Unit:mm)
LG Air Conditioners 2010 60_61Dimensions _ Universal Outdoor
•UU18WH NE1 •UU36WH U31•UU42WH U31•UU48WH U31
•UU21WH U41•UU24WH U41
152O
utdoor unit - DC Inverter SINGLE A (1Ø
, 3Ø)
5CSL0-05ADim
ensions
76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner
CHASSIS CODE: UE1
OUTDOOR UNIT
AUUW186DH[UU18WH UED]
Technical Specification
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
AUUW186DH[UU18WH UED]1/ 220~240 / 50
4.04 13,800
9.5215.88
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Simultaneous operationRefer to combination table
No.123456
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover
1
6
Outdoor unit - DC Inverter SING
LE A (1Ø, 3Ø
)153
5CSL0-05ADim
ensions
76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner
CHASSIS CODE: U4
OUTDOOR UNIT
AUUW216DH [UU21WH U4D]AUUW246DH [UU24WH U4D]
Gas pipe connection
Part Name
Air discharge grille
Liquid pipe connection
Earth screwPower & transmission connection
5
Item No.
2
43
1Remark
Technical Specification
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
AUUW216DH [UU21WH U4D]1/ 220~240 / 50
9.5215.88
AUUW246DH [UU24WH U4D]1/ 220~240 / 50
9.5215.88
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Simultaneous operationRefer to combination table
Outdoor unit - DC Inverter SING
LE A (1Ø, 3Ø
)151
5CSL0-05ADim
ensions
76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner
CHASSIS CODE: U3OUTDOOR UNIT
OUTDOOR UNIT
AUUW428D[UU43W U3D]AUUW488D[UU49W U3D]AUUW608D[UU61W U3D]
Technical Specification
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
SupporterAUUW428D[UU43W U3D]
3/ 380~415 / 50
9.5215.88
AUUW488D[UU49W U3D] 3/ 380~415 / 50
9.5215.88
AUUW608D[UU61W U3D]3/ 380~415 / 50
9.5215.88
490
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Simultaneous operationRefer to combination table
4
No.1234
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connection
•UU12WH UE1
Outdoor unit - DC Inverter SING
LE A (1Ø, 3Ø
)147
5CSL0-05ADim
ensions
76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner
CHASSIS CODE: UEOUTDOOR UNIT
OUTDOOR UNIT
AUUW186D [UU18W UED]
Technical Specification
4
320301
Ø531
513
319
655
630
25
5080
5
546
870
1034
036
0
54.6
160
2
1
3
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
AUUW186D[UU18W UED]1/ 220~240 / 50
6.35 12.7
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Simultaneous operationRefer to combination table
6
No.123456
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection5 Earth screw6 SVC valve cover
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection5 Earth screw
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection5 Earth screw6 SVC valve cover
(Unit:mm)
(Unit:mm)
(Unit:mm)(Unit:mm)
LG Air Conditioners 2010 62_63Dimensions _ Universal Outdoor
•UU18W UED •UU36W UED•UU37W UED
•UU24W UED•UU30W UED
148O
utdoor unit - DC Inverter SINGLE A (1Ø
, 3Ø)
5CSL0-05ADim
ensions
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note1
AUUW246D[UU24W UED]AUUW306D[UU30W UED]
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
AUUW246D[UU24W UED]1/ 220~240 / 50
9.5215.88
AUUW306D[UU30W UED]1/ 220~240 / 50
9.5215.88
Simultaneous operationRefer to combination table
OUTDOOR UNIT
No.123456
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover
6
Outdoor unit - DC Inverter SING
LE A (1Ø, 3Ø
)149
5CSL0-05ADim
ensions
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
AUUW366D[UU36W UED]AUUW368D[UU37W UED]
AUUW366D[UU36W UED]1/ 220~240 / 50
_9.52
15.88
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
AUUW368D[UU37W UED]3/ 380~415 / 50
9.5215.88
Simultaneous operationRefer to combination table
OUTDOOR UNIT
6
No.123456
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover
Outdoor unit - DC Inverter SING
LE A (1Ø, 3Ø
)147
5CSL0-05ADim
ensions
76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner
CHASSIS CODE: UEOUTDOOR UNIT
OUTDOOR UNIT
AUUW186D [UU18W UED]
Technical Specification
4
320301
Ø531
513
319
655
630
25
5080
5
546
870
1034
036
0
54.6
160
2
1
3
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
AUUW186D[UU18W UED]1/ 220~240 / 50
6.35 12.7
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Simultaneous operationRefer to combination table
6
No.123456
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover
•UU09W ULD•UU12W ULD
5CSL0-05ADim
ensions
2.1.4 Dim
ensions
76, Seongsan-dong, Changwon City, Gyeongnam,641-713, Koreawww.lge.com/airconditioner
CHASSIS CODE: ULOUTDOOR UNIT
OUTDOOR UNIT
AUUW096D[UU09W ULD]AUUW126D[UU12W ULD]
Technical Specification
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
AUUW096D[UU09W ULD]1/ 220~240 / 50
6.359.52
AUUW126D[UU12W ULD]1/ 220~240 / 50
Simultaneous operationRefer to combination table
6.359.52
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Refer to combination table
6
No.123456
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection5 Earth screw6 SVC valve cover
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection5 Earth screw6 SVC valve cover
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection5 Earth screw6 SVC valve cover
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection5 Earth screw6 SVC valve cover
(Unit:mm)
(Unit:mm)
(Unit:mm)
(Unit:mm)
Outdoor unit - Non inverter Single A (1Ø
, 3Ø)
245
5CSL0-05ADim
ensions
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
AUUH488D[UU48 U3D]AUUH608D[UU60 U3D]
AUUH488D[UU48 U3D] 3Ø, 380~415V, 50Hz
9.5215.88
AUUH608D[UU60 U3D]3Ø, 380~415V, 50Hz
9.5215.88
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Simultaneous operationRefer to combination table
CHASSIS CODE: U3
Supporter
490
4
244O
utdoor unit - Non inverter Single A (1Ø, 3Ø
)
5CSL0-05ADim
ensions
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
AUUH368D[UU37 UED]
AUUH368D[UU37 UED]1Ø, 220~240V, 50Hz
9.5215.88
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Simultaneous operationRefer to combination table
6
No.123456
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover
242O
utdoor unit - Non inverter Single A (1Ø, 3Ø
)
5CSL0-05ADim
ensions
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
AUUH186D [UU18 UED]
AUUH186D[UU18 UED]1Ø, 220~240V, 50Hz
6.3512.7
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Simultaneous operationRefer to combination table
No.123456
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover
4
320301
Ø531
513
319
655
630
25
5080
5
546
870
1034
036
0
54.6
160
2
1
3
6
Outdoor unit - Non inverter Single A (1Ø
, 3Ø)
243
5CSL0-05ADim
ensions
AUUH246D[UU24 UED]AUUH306D[UU30 UED]
AUUH246D[UU24 UED] 1Ø, 220~240V, 50Hz
9.5215.88
AUUH306D[UU30 UED]1Ø, 220~240V, 50Hz
9.52 15.88
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Simultaneous operationRefer to combination table
1
No.123456
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover
6
Outdoor unit - Non inverter Single A (1Ø
, 3Ø)
241
5CSL0-05ADim
ensions
2.3.4 Dim
ensions1) O
utdoor unit
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
AUUH126D [UU12 ULD]
AUUH126D[UU12 ULD]1/ 220~240 / 50
6.359.52
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Simultaneous operationRefer to combination table
6
No.123456
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connectionEarth screwSVC valve cover
LG Air Conditioners 2010 64_65Dimensions _ Universal Outdoor
•UU12 ULD •UU37 UED
•UU18 UED
•UU24 UED•UU30 UED
•UU48 U3D•UU60 U3D
•UU42W U3D•UU48W U3D•UU60W U3D•UU43W U3D•UU49W U3D•UU60W U3D
150O
utdoor unit - DC Inverter SINGLE A (1Ø
, 3Ø)
5CSL0-05ADim
ensions
1. Unit should be installed in compliance with the installation manual in the product box.2. Unit should be grounded in accordance with the local regulations or applicable national codes.3. All electrical components and materials to be supplied on the site must comply with the local regulations or international codes.4. Electrical characteristics chapter should be considered for electrical work and design. Especially the capacity of power cable and circuit breaker for outdoor unit should be more than that of electrical characteristics chapter.
Note
AUUW426D[UU42W U3D]AUUW486D[UU48W U3D]AUUW606D[UU60W U3D]
AUUW426D[UU42W U3D] 1/ 220~240 / 50
9.5215.88
AUUW486D[UU48W U3D] 1/ 220~240 / 50
9.5215.88
AUUW606D[UU60W U3D]1/ 220~240 / 50
9.5215.88
Supporter
490
Model namePower Supply
Cooling CapacityHeating Capacity
PipingConnections
LiquidGas
Ø/V/HzkWkWmmmm
Simultaneous operationRefer to combination table
OUTDOOR UNIT
No.1234
krameRemaN traPAir discharge grilleGas pipe connectionLiquid pipe connectionPower & transmission connection
4
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection5 Earth screw6 SVC valve cover
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection5 Earth screw6 SVC valve cover
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection5 Earth screw6 SVC valve cover
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection
No. Part Name1 Air discharge grille2 Gas pipe connection3 Liquid pipe connection4 Power & Transmission connection5 Earth screw6 SVC valve cover
(Unit:mm)
(Unit:mm)
(Unit:mm)
(Unit:mm)
(Unit:mm)
(Unit:mm)