TM ® Liebert LTS , 10-32A Reliable Power Redundancy for Business Engines

Liebert®LTSTM, 10 32A - Emerson Power · 2016. 2. 2. · If one-way power fails ... the standby power, and thus ensure the uninterruptible power supply to the mission critical equipments

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Liebert®LTSTM, 10 32A - Emerson Power · 2016. 2. 2. · If one-way power fails ... the standby power, and thus ensure the uninterruptible power supply to the mission critical equipments

TM®Liebert LTS , 10-32AReliable Power Redundancy for Business Engines

Page 2: Liebert®LTSTM, 10 32A - Emerson Power · 2016. 2. 2. · If one-way power fails ... the standby power, and thus ensure the uninterruptible power supply to the mission critical equipments

Emerson Network Power, a business of Emerson, a global company that leads by applying a unique combination of industry expertise, technology, and resources to make the future of our customers' enterprises and networks possible.

Emerson Network Power's broad technology base and global expertise support a full spectrum of enterprise wide solution for today's business needs . We have been providing tailored solutions for protecting the operation of critical electronic systems in virtually every business segment right from customer premise equipment to global network .

Supported by our right combination of knowledge, experience, product selection and service capability.We are the true solution provider of our customer�s IT infrastructure, right from grid to chip level.

When the stakes are high, partner with Emerson Network Power to optimize your technology with �high-nines� reliability solutions specific to your infrastructure.

Emerson.Consider It Solved.

Customers call on Emerson whenthe stakes are the highest. Why?Because they know that we bringthem technology and engineeringto create solutions for their success.Whatever their challenge, they know that with Emerson by their side, they can �Consider It Solved.�

.

We are Emerson

Page 3: Liebert®LTSTM, 10 32A - Emerson Power · 2016. 2. 2. · If one-way power fails ... the standby power, and thus ensure the uninterruptible power supply to the mission critical equipments

Redundancy

Currently, only the high-end severs are equipped with dual power. Other types of equipment, including hub, exchange, router, elementary server, and specialized instrument and meter. are single-power products. You can connect the key equipment to two ways of redundant power through LTS. The main power and the standby power can directly connect to the LTS on the rack can provide redundancy control on the power. Once the main power fails, it will automatically switch to the standby power.

Reliability

The LTS adopts the control technology of �First Disconnect Then Connect�

If one-way power fails, the LTS can ensure the uninterruptible power supply to the equipment through the redundant power supply

Once short circuit occurs, the LTS can ensure that the failure will not extend to the standby power, and thus ensure the uninterruptible power supply to the mission critical equipments

The LTS is a single-pole automatic transfer device with the capacity of 10/16/32 AIt performs the core functions of detection and transfer in the dual-bus system composed of two ways of AC power, and is used in the high-end uninterruptible power supply applications that require high power supply reliability.

Reliable Redundant protection to your mission critical Applications

Applications

Computer equipment rooms

Internet data centers

Telecom&Financial data centers

Industrial process control centers

Redundant Design

To ensure that the equipment can still operate normally upon the failure of one single power.

Ensures strong data processing capacity and improves the system reliability.

Full DSP Control

Enables quick judgment of power-off failure.

Advanced Power-off Detection

Realizes the remote management through SNMP card (option)

Advanced Communication

Compact Size

Optimized 1U size designed to integrate in same server rack

Transfer Button

Input Power Status Output End Status

Failure

Silence Button

UPS Port

10A And 16A Front Panel Schematic Diagram

Transfer Button

Input Power Status Output End Status

Failure

Silence Button

UPS Port

32A Front Panel Schematic Diagram

Source 1 Input Cable (ex-factory delivery)

SNMP Card Slot

Source 1 Input Switch

One 16A Output Socket Six 10A Output Sockets

Source 2 input cable (ex-factory delivery)

Source 2 Input Switch

16A Back Panel Schematic Diagram

32A Back Panel Schematic Diagram

SNMP Card Slot

Source 1 Input Switch

Four 16A Output Socket

Four 10A Output SocketsSource 2 Input Switch

Output Switch1(Controlling the �ve Input Sockets in the lower row)

Output Switch2(Controlling the three Input

Sockets in the upper row)

Output Connector(ex-factory delivery Output Cable)

Source 2 Input Connector(ex-factory delivery Source 2 Input Cable)

Source 1 Input Connector(ex-factory delivery Source 1 Input Cable)

Source 1 Input Cable (ex-factory delivery)

SNMP Card Slot

Source 1 Input Switch

Eight 10A Output Sockets

Source 2 input cable (ex-factory delivery)

Source 2 Input Switch

10A Back Panel Schematic Diagram

Page 4: Liebert®LTSTM, 10 32A - Emerson Power · 2016. 2. 2. · If one-way power fails ... the standby power, and thus ensure the uninterruptible power supply to the mission critical equipments

Liebert LTS or go to

Liebert LTS Technical Speci�cations

Input source

Input mode

Rated voltage

Frequency range

Voltage distortion

Rated frequency

Voltage range

Numbers of poles

Automatic transfer interval

Two ways of input sources

1Φ+N+PE

220/230Vac

Rated frequency ±5Hz

<10%

50/60Hz

150 ~ 300Vac

<6ms (typical), <11ms (maximum)

Storage temperature

Relative humidity

Elevation

0 ~ 40°C

-40 ~ 70°C

5 ~ 95%, no condensation

3000m

Operating temperature

Weight 4.5kg

Power factor

Overload capacity

Ef�ciency (100% linear load)

0.8 ~ 1.0 lead or lag

99%

2 poles

125%, 30min (tested at 30°C)

Input

Output

Transfer

Environment Parameters

Rating 10A 16A 32A

Pollution level Level II

5kg

44mm x 430mm x 250mmDimension (H x W x D)

Mechanical Parameters

84mm x 430mm x 340mm

ACP-STS-1-0-14-4

Input connectors type

Output connectors type

C14 x 2IEC309 x 2(Model 1)

IEC-C20 x 2(Model 2) Hard-wired

C13 C13 & C19 C13 & C19

Rating & Quantity 10A x 8 10A x 6, 16A x 1 10A x 4, 16A x 4