lindab | we simplify construction
- Flexibility when it is needed...
Premum & Premax
With unique
JetCone and Angled Nozzles Patent pending
solution
lindab | we simplify construction
• JetCone– Adjust air volume and distribution profile without any tools – Patent pending regulation system
• Angled Nozzles– Offers a pre-set air pattern combined with JetCone air volume– adjustment and distribution profile
• Market leading cooling performance (Premax)– High cooling capacity, still not creating any draught problems
• Flexible installation– Available in many different dimensions to suit all applications– Suitable for any ceiling type
• AirGuide (plus feature)– Adjust and optimize air pattern without any tools, also for future changes– Ensure optimal distribution and eliminate draft all lifetime– Patent pended regulation system
• Many functions available– Supply air, exhaust air, cooling, heating and regulation
Headlines
T24-Lay-in
Edge D (Hidden grids)
lindab | we simplify construction
• JetCone system– Adjusting air volume, air pressure and air pattern– 4 individually adjustable setting points– 10 steps/point– 40 different combinations
• Angeled Nozzles– Pre-set air spread pattern– Combined with JetCone system– Standard 30º, 16º and 0º
• High cooling capacity– Market leading cooling performance with outstanding
indoor climate (Premax)
• AirGuide (Plus feature)– Adjusting air pattern– 4 individual adjustable rows of deflectors, 2 on each end– Each row of deflectors has 2 adjustment points, 1 in each end– 4 steps/point equals 32 different settings
Full control – Maximum performance
lindab | we simplify construction
• Base dimensions– Width: 600 mm– Length: 1.2 - 3.0 m in steps of 0.1m– Height: only 200 mm
• Premum models for different ceilings– I – Integrated– X – Ecophon edge DS, hidden T-bar and other types
• Connection type– Air: A, B, C, D– Water: 1, 2, 3, 4, 7, 8– Heating (optional)– Exhaust (optional, result in shorter coil)
Models and types
Premum
Installation instruction
lindab | we simplify construction
• Base dimensions– Width: 600 mm – Length: 1.2 m, 1.8 m, 2.4 m and 3.0 m– Height: only 200 mm
• Premax models for different ceilings– I – Integrated– X – Ecophon edge DS, hidden T-bar and other types
• Connection type– Air: A, B, C, D– Water: 1, 2, 3, 4, 7, 8– Heating (optional)– Exhaust (optional, result in shorter coil)
Models and types
Premax
Installation instruction
lindab | we simplify construction
• Supply air (Standard)– A, B, C, D
• Exhaust air (optional)– E, F, G, H
Possible connections Supply air
lindab | we simplify construction
• Cooling (Standard)– 1, 2, 3, 4, 7, 8
Possible connections Water
lindab | we simplify construction
• Cooling / Heating (optional)– 1, 2, 3, 4, 7, 8
Possible connections Water Cooling and Heating
lindab | we simplify construction
• Pre-set air pattern known from Professor beams with 30º, 16º and 0º.
• Standard combination with JetCone air regulation system guarantee draft free Environment
• Simple yet effective way of creating a divergent air spread pattern without loss in capacity.
• In order to meet special demands the Angled Nozzles can be delivered in other configurations.
• Standard settings: – 30º (= AirGuide 30º - 10º) default– 16º (= AirGuide 20º - 10º)– 0º (= AirGuide 10º - 10º)
• (Higher capacity then with AirGuide system (+ 6 %))
Pre-set air distribution
Angled Nozzles
lindab | we simplify construction
Angled NozzlesPosition 0.Max closed nozzle, 20% air flow.
Position 9.Max open nozzle, 100% air flow.
lindab | we simplify construction
long
0°
short
30°
Pre-set air pattern
Angled Nozzles
lindab | we simplify construction
• Adjustable air volume and pressure
• Adjustable air distribution
• Linear air distribution scale
• Optimizing of power performance
• No need of tools
• Accurate adjustment in four points
• 10 steps at each adjustment point
• Total 40 different air volume settings
• No need of dampers
• Easy, fast and cheap balancing
Air regulation system
JetCone
lindab | we simplify construction
4-point air volume regulation
JetCone
09
2 steps up
2 steps down
lindab | we simplify construction
• The air volume is regulated by decreasing / increasing the outlet area of the nozzle
• The decreasing of open area occur by vertical movement of the JetCone through the nozzle
JetCone
lindab | we simplify construction
• Easy and simple adjustment, as known from Lindab Plexus.
Adjustment
JetCone
lindab | we simplify construction
Adjusting air flow
JetCone
4 4
4 4
8 0
0 8
2 5
3 6
4 + 4 + 4 + 4 = 4 0 + 8 + 0 + 8 = 4 2 + 3 + 5 + 6 = 4
lindab | we simplify construction
• Easy AirGuide adjustment between 0, 10, 20 and 30 degrees
• AirGuide default factory set 30°-10°
• Optimize the local working space
• Optimize air pattern when placing beams close to each other
• Optimize air pattern for your special application
Worth noting:
AirGuide set to 0° offers extra capacity (= 6%) without spreading the air (0°, longest throw length); same with Angled Nozzles.
AirGuide system
lindab | we simplify construction
• Flexible control of the air pattern
• Optimizing the possibility of placing beams close to each other
• Fast and easy adjustment, without any tools
• Accurate adjustment in eight points and 32 steps
• Easy to control Air pattern
• Lower capacity then with Angled Nozzles system (-6 %)
AirGuide system (plus feature)
10°- 10°30°-10°
lindab | we simplify construction
Adjusting air pattern
AirGuide
long short
10°- 10° 30° - 10°
lindab | we simplify construction
• Battery and air duct is accessible for cleaning easily
• Coated sheet metal ensures easy cleaning
• Down foldable battery available as an plus feature
Hygienic design
lindab | we simplify construction
• Regula Combi– Room regulator, integrated or loose
• Integrated valves and actuators
• Regula Secura– Condensation guard, integrated
• Regula Connect– Wiring connection system, integrated
Regulation (plus features)
lindab | we simplify construction
• Great Air volume performance, 5 – 66 l/s
• Outstanding air volume accuracy (regulated by the JetCone system, total of 40 steps)
• Supreme power performance at high air volumes, 5 - 20 % higher capacity than competitors (Premax)
• Simple adjustment for changed working conditions in pressure and air flow (tool free)
• Flexible sizing and installation options
• Low installation height, free up space of other installations.
U.S.P
Premum & Premax
lindab | we simplify construction
• Premum and Premax - High performing units with great flexibility– Reach unparalleled cooling capacities (Premax)– Adjust flow and pressure to fit any situation
• Angled Nozzles– Pre-set air pattern combined with JetCone system– Simple yet effective way of creating divergent air pattern without loss of capacity
• JetCone - Patent pending pressure and air flow regulation– Perfect balance between pressure and air flow
• AirGuide - Patent pending air pattern regulation– Ensure the optimal flow pattern, always
• Cooling, heating, ventilation and regulation– Get what you need from one unit with an outstanding result
Summary
lindab | we simplify construction
• MagiCAD– Updated for all products including Premum and Premax– Air and water connections– 76 000 objects– LindQST plug-in
• LindQST– Easy calculation– Shows influence/difference between Angled Nozzles and AirGuide– Easy and fast access to always actual documents
Lindab’s full waterborne product range including Premum and Premax is available
IT solutions
With unique
JetCone and Angled Nozzles Patent pending
solution
lindab | we simplify construction
• All material will be available on the brand-site– Press release– Technical article– Technical material– Giveaways
A flexible message to the market…
Campaign description
brand.lindab.com
With unique
JetCone and Angled Nozzles Patent pending
solution
we simplify construction