14
L22 BA4 52 Line-Mounted Valves L Series www.numatics.com Valves Subject to change without notice. Not liable for printing errors Pneumatic-Catalogue-GB-09/05 496 L1 / L2 Series • Overview How to order: (example) L22 BA4 52 Valve series Port Type Version L11 = 1/8 Aluminium L12 = 1/4 Aluminium L22 = 1/4 Aluminium L23 = 3/8 Aluminium Technical Data 5-ported, 2- or 3-position valves, solenoid pilot actuated Port size: L11 / L12 series = 1/8 or 1/4 L22 / L23 series = 1/4 or 3/8 Flow capacity: L11 / L12 series = 1000 Nl/min = C V 1.0 L22 / L23 series = 1700 Nl/min = C V 1.7 Operating pressure: Vacuum to 10 bar, optioal to 15 bar; with external pilot supply = vacuum to 21 bar Pilot pressure range: 1 to 10 bar (up to 15 bar upon request) Voltage: 24 VDC ± 10% 24 V, - 110 V,- 230 V, 50-60 Hz ± 10% Power input: 3.35 W; optional 5.5 W (DC only) 10/7 VA Response Times [ms] Single actuated (5-port., 2-pos.) energise 10 de-energise 35 energise 7 de-energise 35 Dual actuated (5-port., 2-pos.) energise 10 energise 7 Dual actuated (5-port., 3-pos.) energise 10 de-energise 35 energise 7 de-energise 35 Material Body: Aluminium alloy Other Parts: Stainless steel, steel, aluminium alloy or plastic Static Seals: NBR Finish: Anodized and varnished Note: For conversion to external pilot supply please refer to page 531 Valve Mounting 52 = Line mounted 00* = Manifold mounted w/o Adapter * L11 / L12 series only solenoid actuated valve (BA... BB...) Valve Function PP6 = PP7 = JA4* = JJ4* = JJ5* = JJ6* = JJ7* = * L22 / L23 series only Valve Function BA4 = BB4 = BB5 = BB6 = BB7 = PA4 = PP4 = PP5 =

Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

L22 BA4 52

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05 496

L1 / L2 Series • OverviewHow to order: (example)

L22 BA4 52

Valve series

PortType

Version

L11 = 1/8 Aluminium

L12 = 1/4 Aluminium

L22 = 1/4 Aluminium

L23 = 3/8 Aluminium

Technical Data

5-ported, 2- or 3-position valves, solenoid pilot actuatedPort size: L11 / L12 series = 1/8 or 1/4 L22 / L23 series = 1/4 or 3/8

Flow capacity: L11 / L12 series = 1000 Nl/min = CV 1.0 L22 / L23 series = 1700 Nl/min = CV 1.7

Operating pressure: Vacuum to 10 bar, optioal to 15 bar; with external pilot supply = vacuum to 21 bar

Pilot pressure range: 1 to 10 bar (up to 15 bar upon request)

Voltage: 24 VDC ± 10% 24 V, - 110 V,- 230 V, 50-60 Hz ± 10%

Power input: 3.35 W; optional 5.5 W (DC only) 10/7 VA

Response Times [ms]Single actuated (5-port., 2-pos.) energise 10 de-energise 35 energise 7 de-energise 35

Dual actuated (5-port., 2-pos.) energise 10 — energise 7 —

Dual actuated (5-port., 3-pos.) energise 10 de-energise 35 energise 7 de-energise 35

MaterialBody: Aluminium alloy

Other Parts: Stainless steel, steel, aluminium alloy or plastic

Static Seals: NBR

Finish: Anodized and varnishedNote: For conversion to external pilot supply please refer to page 531

ValveMounting

52 = Line mounted

00* = Manifold mounted w/o Adapter

* L11 / L12 series only

solenoid actuated valve (BA... BB...)

ValveFunction

PP6 =

PP7 =

JA4* =

JJ4* =

JJ5* =

JJ6* =

JJ7* =

* L22 / L23 series only

ValveFunction

BA4 =

BB4 =

BB5 =

BB6 =

BB7 =

PA4 =

PP4 =

PP5 =

Page 2: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

B G 000 61

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05 497

Order example: L22BA452BG00061

This refers to a L2 series single solenoid pilot actuated 5-ported, 2-position directional valve withspring return. Port size of the valve is G 1/4. Turning manual override is stan dard.The solenoid is intended for a female connector to industrial form, type 22 mm and has a voltageof 24 VDC.

L1 / L2 Series • Overview

Optionsg

000* = Turning manual override BA / BB-valves

000 = Pushing, non locking manual override JA / JJ-valves

000* = Without manual override PA / PP-valves

12A = Version withVITON®-O-rings

14A = Version for external pilot air

15Z = Solenoid rotated by 180°

17P = Non-locking manual override,BA- / BB-valves

Q16 = As 3-port., 2-pos. valve, NC (normally closed)

R16 = As 3-port., 2-pos. valveNO (normally open)

17G = Low wattage: 1.42 W (up to max. 8 bar) in DC only

* manual override acting on pilot valveMore options on request

Voltage

61 = 24 VDC

40 = 230 VAC/50-60 Hz

30 = 110 VAC/50-60 Hz

20 = 24 VAC/50-60 Hz

00 = Air pilot actuated

SolenoidType

0 = Air pilot actuatedPA / PP / JA / JJ-valves

0 = AC, solenoid to industrial form, type 22 mm BA / BB-valves

A = AC and DC, solenoid to DIN EN 175301-803,(old DIN 43650), form B, BA /BB valves

B = DC, solenoid to industrial form, type 22 mm BA / BB-valves

PortType

G = G-thread

0 = NPTF-thread

air pilot actuated valvewith manual override

(JA... JJ...)

air pilot actuated valvew/o manual override

(PA... PP...)

Page 3: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05498

Single or Dual Solenoid Pilot Actuated ValvesPort Size 1/8 or 1/4

L1 Series • Dimensions

L11 / L12 BA4..

L11 / L12 BB4/5/6/7..

Dimensions [mm]

ValveFunction A B C D E F G H J K L M Weight

approx. [kg]

BA4.. 123.2 22.2 41.1 3.3 15.8 24.4 84.5 73.6 18.0 — 38.0 M3x12 deep 0.270

BB4.. 179.4 22.2 41.1 3.3 15.8 24.4 103.6 81.7 18.0 — — M3x12 deep 0.420

BB5/6/7.. 190.0 22.2 41.1 3.3 15.8 24.4 114.0 92.2 18.0 — — M3x12 deep 0.440

PA4.. — 22.2 41.1 3.3 15.8 24.4 — 2.2 18.0 75.8 83.8 M3x12 deep 0.190

PP4/5/6/7.. 91.6 22.2 41.1 3.3 15.8 24.4 75.7 2.2 18.0 — — M3x12 deep 0.210

Attention: Use fi ttings only to max. 14 mm wrench size.

External pressure port for BA-/BB-valves in M5

Pilot tubing port for PA/PP-valves in 1/8

Single or Dual Air Pilot Actuated Directional ValvesPort Size 1/8 or 1/4

L11 / L12PA4...L11 / L12PP4/5/6/7...

Page 4: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05 499

L2 Series • DimensionsSingle or Dual Solenoid Pilot Actuated ValvesPort Size 1/4 or 3/8

L22 / L23BA452...

L22 / L23 BB4/5/6/752...Single or Dual Air Pilot Actuated ValvesPort Size 1/4 or 3/8

L22 / L23PA4...L22 / L23PP4/5/6/7... L22 / L23JA4...

L22 / L23JJ4/5/6/7...Dimensions [mm]

ValveFunction A B C D E F G H J K L M N P Q Weight

[kg]

BA4.. 136.6 25.4 50.8 54.5 4.3 32.3 22.2 19.0 99.0 89.7 47.0 2.1 — — M4x7.5 deep 0.390

BB4.. 193.5 25.4 50.8 54.5 4.3 32.3 22.2 19.0 117.5 99.0 90.2 2.1 52.2 42.9 M4x7.5 deep 0.550

BB5/6/7.. 206.6 25.4 50.8 54.5 4.3 32.3 22.2 19.0 130.6 111.9 103.3 2.1 65.3 56.0 M4x7.5 deep 0.600

PA4.. — 25.4 50.8 32.3 4.3 — 22.2 19.0 — 89.7 97.8 2.1 — — M4x7.5 deep 0.290

PP4/5/6/7.. 101.5 25.4 50.8 32.3 4.3 — 22.2 19.0 85.7 — — 2.1 — — M4x7.5 deep 0.310

JA4.. — 25.4 50.8 32.3 4.3 — 22.2 19.0 — 89.7 97.8 2.1 115.8 — M4x7.5 deep 0.300

JJ4/5/6/7.. 137.5 25.4 50.8 32.3 4.3 101.5 22.2 19.0 85.7 — — 2.1 — — M4x7.5 deep 0.320

Attention: Use fi ttings only to max. 19 mm wrench size.

External pressure port for BA-/BB-valves in 1/8

Pilot tubing port for PA/PP-valves in 1/8

Page 5: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

L22 BA4 52 T

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05 500

SolenoidType

0 = 24/110/230 VACsolenoid to industrial formtype 22 mm

A = 24/110/230 VAC or 24 VDCsolenoid to DIN EN 175301-803 (old DIN 43650) form B, type 22 mm

B = 24 VDCsolenoid to industrial formtype 22 mm

T = 24 VDCsolenoid to ISO 20401 with M12connector and LED,type 22 mm

7 = 24 VDCsolenoid withDESINA standard connector M12, with LED, type 22 mm

C =solenoid to industrial form, type 22 mm withUL- and CSA-approval

2 = ACsolenoid to DIN EN 175301-803 (old DIN 43650) form A type 30 mm

4 = DCsolenoid to DIN EN 175301-803 (old DIN 43650) form A type 30 mm

L1 / L2 Series with Exchangeable Pilot Coil • OverviewHow to order: (example)

Solenoid type 22 mmFast-on connectors to industrial formalso with UL- and CSA-approvalSolenoid can be rotated by 45°

Solenoid type 22 mmwith M12-Stecker and LED orDESINA standard connector M12 and LEDSolenoid can be rotated by 45°

ValveSeries

PortType

Version

L11 = 1/8 Aluminium

L12 = 1/4 Aluminium

L22 = 1/4 Aluminium

L23 = 3/8 Aluminium

Technical Data

5-ported, 2- or 3-position valves, solenoid pilot actuatedPort size: L11/L12 series = 1/8 or 1/4 L22L23 series = 1/4 or 3/8

Flow capacity: L11/L12 series = 1000 Nl/min = CV 1.0 L22/L23 series = 1700 Nl/min = CV 1.7

Operating pressure: Vacuum to 10 bar; optional = to 16 bar; with external pilot supply = vacuum to 21 bar

Pilot pressure range: 1 to 10 bar (up to 16 bar upon request)

Voltage: 24 VDC ± 10% 24 V, - 110 V, - 230 V, 50-60 Hz ± 10%

Power input: 4.8 W 10/7 VA

Response Times [ms]Single actuated (5-port, 2-pos.) energise 10 de-energise 35 energise 7 de-energise 35

Dual actuated (5-port, 2-pos.) energise 10 — energise 7 —

Dual actuated (5-port, 3-pos.) energise 10 de-energise 35 energise 7 de-energise 35

MaterialBody: Aluminium alloy

Other Parts: Stainless steel, steel, aluminium alloy or plastic

Static Seals: NBR

Finish: Anodized and varnished

Note: For conversion to external pilot supply please refer to page 531

ValveMounting

52 = Line mounted

ValveFunction

BA4 =

BB4 =

BB5 =

BB6 =

BB7 =

Solenoid type 22 mmFast-on connectors to DIN EN 175301-803 (old DIN 43650) form BSolenoid can be rotated by 45°

Page 6: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05 501

Q A02 61

L1 / L2 Series with Exchangeable Pilot Coil • Overview

Version

Q = Mounted with adapter for exchangeable pilot coil and G-thread

P = Mounted with adapter for exchangeable pilot coil and NPTF-thread

Voltage

61 = 24 VDC ± 10%

40 = 230 VAC/50-60 Hz ± 10%

30 = 110 VAC/50-60 Hz ± 10%

20 = 24 VAC/50-60 Hz ± 10%

Order example: L22BA452TQ00061

This refers to a L2 series single solenoid pilot actuated 5-ported, 2-position directional valve with exchangeable pilot coil and spring return. Port size of the valve G 1/4. Internal pilot supply is standard.The solenoid to ISO 20401 has a M12 connector and LED and is type 22 mm. It is intended for an operating voltage of 24 VDC.

Optionen

000* = Exchangeable pilot coil with manual overrde push/locking

14A = Version for external pilot air

17P = Non-locking manual override

Q16 = As 3-port., 2-pos. valve, NC (normally closed)

R16 = As 3-port., 2-pos. valveNO (normally open)

17G = Low wattage: 1.2 W (up to max. 8 bar) in DC only

* manual override acting on pilot valveMore options on request

Page 7: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

S22 BA4 52

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05 502

S2 Series with Exchangeable Pilot Coil and Stainless Steel Body • OverviewHow to order: (example)

Valve Series

PortType

Version

S22 = 1/4 stainless steel316

ValveMounting

52 = Line mounted

Technical Data

5-ported, 2- or 3-position valves, solenoid pilot actuaedPort size: S22 series = 1/4

Flow capacity S22 series = 1700 Nl/min = CV 1.7

Operating pressure Vacuum to 10 bar; optional = to 16 bar; with external pilot supply = vacuum to 21 bar

Pilot pressure range 1 to 10 bar (upon request up to 16 bar)

Voltage: 24 VDC ± 10% 24 V, - 110 V,- 230 V, 50-60 Hz ± 10%

Power input: 4.8 W 10/7 VA

Response Times [ms]Single actuated (5-port./2-pos.) energise 10 de-energise 35 energise 7 de-energise 35

Dual actuated (5-port./2-pos.) energise 10 — energise 7 —

Dual actuated (5-port./3-pos.) energise 10 de-energise 35 energise 7 de-energise 35

MaterialBody: Stainless steel 316

Other Parts: Stainless steel, steel, aluminium alloy or plastic

Static Seals: NBR

Finish: without

Note: For conversion to external pilot supply please refer to page 531

solenoid actuated valve (BA... BB...)

air pilot actuated valvew/o manual override

(PA... PP...)

ValveFunction

BA4 =

BB4 =

BB5 =

BB6 =

BB7 =

PA4 =

PP4 =

PP5 =

PP6 =

PP7 =

On request:3-port./2-pos. NO- or NC-version

Page 8: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05 503

SolenoidType

0 = Air pilot actuatedPA / PP-valves

0 = 24/110/230 VACsolenoid to industrial formtype 22 mm

A = 24/110/230 VAC or 24 VDCsolenoid to DIN EN 175301-803 (old DIN 43650), form B, type 22 mm

B = 24 VDCsolenoid to industrial formtype 22 mm

T = 24 VDCsolenoid to ISO 20401 with M12 connector andLED, type 22 mm

7 = 24 VDCsolenoid with DESINA standardconnector M12with LED, type 22 mm

C = 24/110/230 VAC or 24 solenoid to industrial form, type 22 mm, withUL and CSA approval

2 = ACsolenoid to DIN EN 175301-803 (old DIN 43650)form A , type 30 mm

4 = DCsolenoid to DIN EN 175301-803 (old DIN 43650) form A, type 30 mm

Order example: S22BA452TQ00061

This refers to a S2 series single solenoid pilot actuated 5-ported, 2-position valve with exchangeable pilot coil and spring return, stainless steel body. Port size of the valve is G 1/4. Internal pilot supply and manual override push/locking are standard. The solenoid to ISO 20401 has a M12 connector and LED and is type 22 mm. It is intended for an operating voltage of 24 VDC.

S2 Series with Exchangeable Pilot Coil and Stainless Steel Body • Overview

T Q 000 61

Version

Q = Mounted with adapterfor exchangeable pilot coil and G-threadBA / BB-valves

Q = Air pilot actuated and G-threadPA / PP / JA / JJ-valves

P = Mounted with adapter for exchangeable pilot coil and NPTF-threadBA / BB-valves

P = Air pilot actuated andNPTF-threadPA / PP / JA / JJ-valves

Voltage

61 = 24 VDC ± 10%

40 = 230 VAC/50-60 Hz ± 10%

30 = 110 VAC/50-60 Hz ± 10%

20 = 24 VAC/50-60 Hz ± 10%

00 = Air pilot actuated

Optionen

000* = Exchangeable pilot coil with manual overrde push/locking

14A = Version for external pilot air

17P = Non-locking manual override

Q16 = As 3-port., 2-pos. valve, NC (normally closed)

R16 = As 3-port., 2-pos. valveNO (normally open)

17G = Low wattage: 1.2 W (up to max. 8 bar) in DC only

* manual override acting on pilot valveMore options on request

Page 9: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05504

L1/L2 Series with Exchangeable Pilot Coil • S2 Series Stainless Steel Version • DimensionsSingle or Dual Solenoid Pilot Actuated Directional Valves

L11 / L12BA452.Q......L22 / L23BA452.Q......S22BA452.Q......

L11 / L12 BB452.Q......L22 / L23 BB452.Q......S22BB452.Q......orL11 / L12 BB5/6/752.Q......L22 / L23 BB5/6/752.Q......S22BB5/6/752.Q......

Drawing shows S22BA452BQ00061

Dimensions [mm]

Series Function A B C D E F G HWeight approx. [kg]

L1/L2 Series S2 SeriesL1 BA4 133.0 22.2 41.1 M3x12 deep 3.3 24.4 18.0 18.0 0.270 —

L1 BB4 197.5 22.2 41.1 M3x12 deep 3.3 24.4 18.0 18.0 0.420 —

L1 BB5/6/7 208.0 22.2 41.1 M3x12 deep 3.3 24.4 18.0 18.0 0.440 —

L2/S2 BA4 148.0 25.4 50.8 M4x8 deep 4.3 32.3 22.2 19.0 0.390 0.960

L2/S2 BB4 214.0 25.4 50.8 M4x8 deep 4.3 32.3 22.2 19.0 0.550 1.300

L2/S2 BB5/6/7 225.5 25.4 50.8 M4x8 deep 4.3 32.3 22.2 19.0 0.600 1.460

Attention: Use fi ttings only to max. wrench size of 14 mm (L1 series) or max. wrench size 19 mm (L2 / S2 series).

External pressure supply for BA / BB- valves in M5

Drawing shows S22BB552BQ00061

Page 10: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05 505

S2 Series Stainless Steel Version • DimensionsSingle or Dual Air Pilot Actuated Valves

S22PA4520Q00000 S22PP4/5/6/7520Q00000

Drawing shows S22PP5520Q00000

Pilot tubing port

Dimensions [mm]

Series Function A B C D E F G H Weightapprox. [kg]

S2 PA4 98.0 25.4 50.8 M4x8 deep 4.3 32.3 22.2 19.9 0.700

S2 PP4/5/6/7 102.0 25.4 50.8 M4x8 deep 4.3 32.3 22.2 19.9 0.760

Attention: Use fi ttings only to max. wrench size of 19 mm.

Pilot tubing port for PA / PP-valves in M5

Page 11: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05506

Manifolds for Front Mounting, Port Size G 1/4

Accessories (without picture)

Manifolds and Accessories • L1 Series

Dimensions [mm]

Station A B C D E F G H J K L Weightapprox. [kg]

OrderCode

2 88.5 78.5 0.410 106-540

3 119.0 109.0 0.550 106-541

4 149.5 139.5 0.690 106-542

5 180.0 170.0 0.830 106-543

6 210.5 200.5 0.970 106-544

7 241.0 231.0 70.6 36.0 21.0 30.5 35.5 22.0 11.0 5.3 42.0 1.120 106-545

8 271.5 261.5 1.260 106-546

9 302.0 292.0 1.400 106-547

10 332.5 322.5 1.540 106-548

11 363.0 353.0 1.680 106-549

12 393.5 383.5 1.820 106-550

Note: Valves can only be mounted on manifold with adapter plate 239-311.

On request: NPTF-thread

Dimensions [mm]

Description Application Length Width Height Weightapprox. [kg]

OrderCode

Adapter plate* 1 plate per station 59.2 22.1 5.6 0.020 239-311

Blank station plate only manifold front mounting 59.2 22.1 11.9 0.040 239-288

Blocking plug to separate gallery "1" — — — — 20.5499

Blocking screws G 1/4

to close ports "1" and/or "3" & "5" — — — — N411-001

* Incl. screws and gaskets

Page 12: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05 507

Manifolds and Accessories • L2 Series Manifolds for Front Mounting, Port Size G 3/8

Manifolds for Rear Mounting, Port Size G 3/8

Dimensions [mm]

Station A B C D E F G H J K Weightapprox. [kg]

OrderCode

2 105.4 67.0 0.410 106-715

3 137.4 99.4 0.540 106-716

4 169.4 131.4 0.670 106-717

5 201.4 163.4 0.800 106-718

6 233.4 195.4 0.939 106-719

7 265.4 255.4 70.5 63.4 44.4 32.0 30.6 212.4 4.1 22.2 1.060 106-720

8 297.4 259.4 1.190 106-721

9 329.4 291.4 1.320 106-722

10 361.4 323.4 1.450 106-723

11 393.4 355.4 1.580 106-724

12 425.4 387.4 1.710 106-725

Note: Valves can only be mounted on th manifold with adapter plate 239-312.

On request: NPTF-thread

Dimensions [mm]

Station A B C D E F G H J K Weightapprox. [kg]

OrderCode

2 99.6 61.0 0.360 229-979

3 127.7 87.1 0.460 229-980

4 151.9 113.3 0.560 229-981

5 178.1 139.4 0.660 229-982

6 204.2 165.6 0.750 229-983

7 230.4 191.8 70.5 63.4 44.4 26.2 28.7 11.4 4.1 22.2 0.850 229-984

8 256.5 217.9 0.950 229-985

9 282.7 244.1 1.050 229-986

10 308.9 270.3 1.140 229-987

11 335.0 296.4 1.240 229-988

12 361.2 322.6 1.340 229-989

Incl. screws and gaskets

On request: NPTF-thread

Page 13: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05508

Accessories (without picture)

Manifolds and Accessories • L2 Series

Valve Isolating Plates, to Lock Port 1allow to replace valves without depressurizing the system

Manifolds in P Gallery Version, Port Size G 3/8

Dimensions [mm]

Station A B C D E F G H Weightapprox. [kg]

OrderCode

2 99.6 61.0 0.110 229-957

3 127.7 87.1 0.140 229-958

4 151.9 113.3 0.170 229-959

5 178.1 139.4 0.200 229-960

6 204.2 165.6 0.230 229-961

7 230.4 191.8 19.0 26.2 4.1 22.9 24.6 11.4 0.260 229-962

8 256.5 217.9 0.290 229-963

9 282.7 244.1 0.330 229-964

10 308.9 270.3 0.360 229-965

11 335.0 296.4 0.390 229-966

12 361.2 322.6 0.420 229-967

Incl. screws and gaskets

On request: NPTF-thread

Dimensions [mm]

Description A B C D E F Weightapprox. [kg]

OrderCode

Valve isolating plate*

72.0 70.1 38.1 25.4 20.0 10.0 0.150 10.6445

Incl. screws and gaskets (1 plate per station)

* Note: Does not seal hermetically. Only for exchange of valves.

Dimensions [mm]

Description Application Length Width Height Weightapprox. [kg]

OrderCode

Adaptor plate* 1 plate per stationonly manifold front mounting

70.1 25.4 7.14 0.020 239-312

Blank station plate* only manifold front mounting 70.1 25.4 13.5 0.050 239-471

Blank station plate* only manifold rear mounting 71.1 25.4 6.35 0.030 229-991

Blank station plate* only manifold P version 25.4 24.6 6.35 0.020 229-990

Sandwich speed control* only manifold front und rear mounting

— — — 0.080 239-209

Blocking plug to separate gallery "1", "3" & "5" — — — — 20.5499

Blocking screwsG 3/8

to close ports "1" and/or "3" & "5"

— — — — N411-002

* Incl. screws and gaskets

Page 14: Line-Mounted Valves L Seriesimg51.chem17.com/5/20130419/635019770745625000589.pdf2013/04/19  · Line-Mounted Valves L Series Valves Subject to change without notice. Not liable for

Line-Mounted Valves L Series

www.numatics.com

Valv

es

Sub

ject

to c

hang

e w

ithou

t not

ice.

Not

liab

le fo

r prin

ting

erro

rs

Pneumatic-Catalogue-GB-09/05 509

Completely Assembled Manifolds • L1 / L2 Series

How to order: (example)

AKL 33A — 06

Order example: 1. Mounting kit AKL33A—062. Valve Station 1 = L23BA452AG00061

Station 2 = L23BA452AG00061 Station 3 = L23PA4520G00000 10.6445 Station 4 = L23BB452AG00061 Station 5 = L23BB552AG00061 239-209 Station 6 = 239-471 ASSEMBLED

All valves of L1 / L2 series and L1 / L2 series with exchangeable pilot coil are also available as completely assembled manifolds. The valves are listed from left to right. (please refer to order example)More than 12 stations are not recommended, as the fl ow rate would be too low.

Manifold Mounting Kit

AKL = Completely assembled manifold

Numberof stations

02 = 2 stations

03 = 3 stations

04 = 4 stations

05 = 5 stations

06 = 6 stations

07 = 7 stations

08 = 8 stations

09 = 9 stations

10 = 10 stations

11 = 11 stations

12 = 12 stations

PortType

12A = L1 series; manifold for front mountingwith port thread in G 1/4 (incl. adapter plate)

33 = L2 series;manifold for rear mounting with port thread in G 3/8

33A = L2 series; manifold for front mounting with port thread in G 3/8 (incl. adapter plate)

31 = L2 series;manifold in P version, port thread in G 3/8

Station 6Blank station plate

(239-471)

Station 5Dual solenoid pilot actuated 5-ported, 3-position valves

(L23BB552AG00061)sandwich speed control

(239-209)

Station 4Dual solenoid pilot actuated 5-ported, 2-position valves

(L23BB452AG00061)

Station 3single air pilot actuated

5-ported, 2-position valves(L23PA4520G00000)

Valve isolating plate (10.6445)

Station 1 and 2Single solenoid pilot actuated

5-ported, 2-position valves(L23BA452AG00061)