5
DENTAL HAND INSTRUMENTS

Lite-Touch Intro

Embed Size (px)

DESCRIPTION

Dental Instruments

Citation preview

Page 1: Lite-Touch Intro

DENTAL HAND INSTRUMENTS

Page 2: Lite-Touch Intro

DENTAL HAND INSTRUMENTS

2

Ongard Lite-Touch Dental Hand Instruments are manufactured in Italy from high quality steel sourced from leading suppliers in Europe and Japan. By selecting steel suppliers from the very best available Ongard have guaranteed Lite-Touch instruments are made to exacting individual measures of temper and hardness as required for each instruments intended use. Following extensive testing, evaluation and quality assurance inspections Ongard has partnered with a manufacturer of superb pedigree and advanced technical abilities. The use of CAD, CNC, Laser and the latest in manufacturing robotics ensures Lite-Touch instruments are produced to exacting modern standards (ISO 9001.) Reassuringly, all Lite-Touch instrument’s are still individually hand finished and inspected.

In line with world class quality standards Lite-Touch Hand Dental Instruments have a number of superior clinical features and benefits, including:

• Explorers, Probes, and Composite instruments with light weight hollow handles for maximum comfort and fatigue reduction.

• Titanium Nitride coated Composite instruments delivering easy restorative placement.

• Tungsten Carbide tipped Scissors, Tweezers and Needle holders for instrument longevity and superior performance.

• Forceps with Teflon® disc hinge inserts for ease of use and minimal wear extending instrument life.

Ongard is an Australian Brand recognised for over 10 years for delivering superior dental products that are competitively priced and eminently fit for intended use.

‘Ongard – Quality you can trust’

Teflon® is a registered trademark of E. I. du Pont de Nemours and Company or its affiliates.

W9 Pty Ltd 27-29 Salisbury Rd Hornsby NSW 2077 Australia

Ph: (+612) 9987 4224 Fx: (+612) 9476 6629 Em: [email protected] Web: www.w9.com.au

Page 3: Lite-Touch Intro

3DENTAL HAND INSTRUMENTS

Maintenance and Sterilisation of Lite-Touch Dental Hand Instruments

Lite-touch dental hand instruments are designed to be used exclusively by dental personnel. To assure optimum performance and maximum product life, the instruments must be maintained correctly and used for the clinical purposes for which they are designed. Particular attention must be paid to their cleaning and sterilisation.

Cleaning

As Lite-Touch instruments are supplied in non-sterile packaging they must be rinsed and sterililsed before initial use. (See Autoclave Sterilisation below)

1. After use, all instruments must be rinsed in warm water to remove debris, including blood and materials, remaining on the instruments after the completion of treatment. A surgical cleaning brush with nylon bristles can be used to assist this process.

2. Instruments should be further cleaned by placing them in an instrument cassette for insertion into an ultrasonic bath. The instrument cassette should have grooves suitable for instruments with a round or octagonal handle so that when the cassette is closed, each instrument is held firmly in place, thus preventing scratching, pitting or blunting during the vibrations of the ultrasonic cycle.

3. Instruments with hinges such as forceps and scissors should be placed on mats and left open during the cycle. It is important these instruments do not touch.

4. Instruments manufactured from different metals must not be processed in the same cycle.

5. The instruments must be fully covered in the bath by the ultrasonic solution.

6. Instruments must be either air-dried or dried by lint-free cloth.

7. Water-soluble surgical lubricant must be applied to hinged-instruments before closure of the hinge.

Autoclave Sterilisation

After completing the above cleaning process, place the instruments in sterilisation packaging such as self-seal pouches, sterilisation-wrap or instrument cassettes and load into the autoclave. Instruments with hinges should be left open so that maximum steam penetration can be achieved. The sterilisation temperature of the autoclave must not exceed 175oC.

The autoclave manufacturer’s instructions must be followed.

W9 Pty Ltd 27-29 Salisbury Rd Hornsby NSW 2077 Australia

Ph: (+612) 9987 4224 Fx: (+612) 9476 6629 Em: [email protected] Web: www.w9.com.au

Page 4: Lite-Touch Intro

DENTAL HAND INSTRUMENTS

4

SEO6 - Single Ended Octagonal 6mm

DEA8 - Double Ended Aluminium 8mm

SEA8 - Single Ended Aluminium 8mm

DES6 - Double Ended Solid 6mm

SES6 - Single Ended Solid 6mm

DEH8 - Double Ended Hollow 8mm

DEO6 - Double Ended Octagonal 6mm

Hand Instrument Handle Guide

Page 5: Lite-Touch Intro

5DENTAL HAND INSTRUMENTS

Contents

Explorers, Probes & Root Canal Instruments 7-12

Excavators 14-16

Amalgam Carvers 17-19

Gingival Margin Trimmers & Enamel Instruments 20-21

Filling Instruments 23-29

Composite Instruments 30-31

Heidemann & Cement Spatulas 32-33

Curettes 35-41

Scalers 42-43

Extraction ForcepsAnatomical, English, Child & USA Patterns 45-61

Forceps 62

Elevators 64-71

Periosteals 73-79

Bone Rongeurs 81-82

Bone Curettes, Bone Chisels & Bone Files 84-88

Implantology 90-103

Microsurgery 105-106

Needle Holders 108-110

Scissors 112-114

Tweezers, Tissue & Dressing Tweezers 116-117

Orthodontic Pliers 119-123

Laboratory 125-129

Miscellaneous Items 131-132

Index 134-135