16
Ningbo TengLi Testing Co., Ltd 2nd floor, Block B, Ningbo Testing and Certification Base, No. 66 Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang Tel: 86574-8783 6802 Fax: 86574-8783 5902 Report No.: JBE190106-I Report Format Number STD/QP019-409-A/0-NB http://www.standard-tech.com 1 / 16 LM-79-08 Test Report For Revolution Lighting Technologies, Inc. (Brand Name: Revolution Lighting Technologies) 2280 Ward Ave. Simi Valley CA. 93065 Model name(s): 203012-21X-XXX[-A, -USA or Blank] Report Type: Testing and Report According to IES LM-79-2008 Type of Luminaire: Internal Driver/Line Voltage (UL Type B) Lamps Report Date: 2019-01-30 Prepared By: Ningbo TengLi Testing Co., Ltd 2nd floor, Block B, Ningbo Testing and Certification Base, No. 66 Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang Test & Report By: Review By: Xeon Ren Johnson Sun Engineer: Xeon Ren Manager: Johnson Sun Note: 1. The results contained in this report pertain only to the tested samples 2. This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.

LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

1 / 16

LM-79-08 Test Report

For

Revolution Lighting Technologies, Inc.

(Brand Name: Revolution Lighting Technologies)

2280 Ward Ave. Simi Valley CA. 93065

Model name(s):

203012-21X-XXX[-A, -USA or Blank] Report Type: Testing and Report According to IES LM-79-2008

Type of

Luminaire: Internal Driver/Line Voltage (UL Type B) Lamps

Report Date: 2019-01-30

Prepared By:

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base,

No. 66 Qingyi Road, Ningbo National Hi-Tech Zone,

Ningbo, Zhejiang

Test & Report By: Review By:

Xeon Ren Johnson Sun

Engineer: Xeon Ren Manager: Johnson Sun

Note: 1. The results contained in this report pertain only to the tested samples

2. This report does not imply product certification, approval, or endorsement by NVLAP, NIST,

or any agency of the Federal Government.

Page 2: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

2 / 16

1.1 Product Information:

Model Number 203012-21X-XXX[-A, -USA or Blank]

Remark

Where “X” stand for CCT, 1=3000k, 2=3500k,

3=4000k, 5=5000k

Where the “XXX” can be “A”, “USA”, or blank,

and represents manufacturing origin.

“A” = Trade Agreements Act (TAA) - Compliant

“USA” = Buy American Act (BAA) - Compliant

Blank = Non-USA Manufacturing.

Representative (Tested) Model 203012-211-XXX

203012-215-XXX

Model Difference All construction and rating are the same, except

CCT and manufacturing origin.

SKU (if available) N/A

Type of Luminaire

(for integral lamps, list base type and lamp type) Internal Driver/Line Voltage (UL Type B) Lamps

LED Manufacturer EVERLIGHT ELECTRONICS CO., LTD

LED Model 3000K: 67-21S/KK4C-H302932Z6/2T(HN)

5000K: 67-21S/KK4C-H503132Z6/2T(HN)

Dimming Non-dimmable

Sample Number JBE190106-I1,I2(3000K),I3(5000K)

Date of Receipt Jan.20,2019

Luminaire Aperture (for downlights) -- in.

Luminaire Length 900 mm

Luminaires Width -- mm

Number of Units (modular products) N/A s

1.2 Rated Values:

Rated Voltage / Frequency 120-277Vac, 50/60Hz

Nominal Power 12W

Rated Initial Lamp Lumen --

Declared CCT 3000K,3500K,4000K,5000K

Page 3: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

3 / 16

1.3 Test Specifications:

Test item

1. Total Luminous Flux

2. Luminous Distribution Intensity

3. Luminous Efficacy

4. Correlated Color Temperature

5. Color Rendering Index

6. Chromaticity Coordinate

7. Electrical Parameters

Reference Standard

1. IES LM-79-2008 Electrical and Photometric Measurements of

Solid-State Lighting Products

2. ANSI C78.377-2015 Specifications for the Chromaticity of Solid

State Lighting Products

3. CIE 13.3-1995 Method of Measuring and Specifying Colour

Rendering Properties of Light Sources

4. CIE 15-2004 Technical Report Colorimetry

5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source

6. IESNA TM-16-05 Technical Memorandum on Light Emitting

Diode (LED) Sources and Systems

Reference Work Instruction QD25

1.4 Test Methods

1) Photometric and Light Distribution Measurement – Goniophotometer Method:

Photometric parameters were measured using the goniophotometer and software. The ambient

temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the

sample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz.

It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were

calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.

2) Chromaticity Measurement – Sphere-Spectroradiometer Method:

Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software.

The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample

measurements were made using a spectroradiometer connected by a fiber optic cable and detector

through the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC,

60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color

temperature and color rendering index were calculated from the spectral power distribution taken at 5

nm intervals over the range of 380 to 780 nm.

3) Electrical Measurements:

Electrical parameters were measured using power meters incorporated in goniophotometer or

sphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at

25º C ± 1º C. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before

measurement was made. Voltage, frequency, current, power, power factor and total harmonic distortion

were measured by and read from the power meter.

Page 4: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

4 / 16

2.1 Summary of Test Result

Criteria Item Measured Value Compliance Requirement

(DLC V4.4)

Power(W)

3000K

Bare Lamp

120V 13.05 N/A N/A

277V 13.01

3000K

In Luminaire

120V 24.99

N/A N/A 277V 24.98

5000K

Bare Lamp

120V 13.12

277V 13.10

Power Factor

3000K

Bare Lamp

120V 0.9658

Pass >= 0.9(-3%)

277V 0.9160

3000K

In Luminaire

120V 0.9554

277V 0.9123

5000K

Bare Lamp

120V 0.9604

277V 0.9087

THD %

3000K

Bare Lamp

120V 17.41

Pass <= 20(+5)

277V 21.54

3000K

In Luminaire

120V 17.82

277V 21.81

5000K

Bare Lamp

120V 17.93

277V 21.89

CRI

3000K Bare Lamp 81.6

Pass >= 80(-2) 3000K In Luminaire 82.0

5000K Bare Lamp 82.1

CCT (K)

3000K Bare Lamp 3027

Pass <=5000K 3000K In Luminaire 3031

5000K Bare Lamp 5046

Luminous Intensity

Distribution Zonal lumens in the 0-60°: 67.9 Pass >= 40(-3)

Total Luminous

3000K

Bare Lamp

120V 1501

Pass

>=1200(-10%) 277V 1507

3000K

In Luminaire

120V 2639.7 >=2200(-10%)

277V 2651.0

5000K

Bare Lamp

120V 1594 >=1200(-10%)

277V 1602

Luminous Efficacy

3000K

Bare Lamp

120V 115.02

Pass

Standard: >=

110(-3%) 277V 115.83

3000K

In Luminaire

120V 105.63 Standard: >=

100(-3%) 277V 106.12

Page 5: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

5 / 16

5000K

Bare Lamp

120V 121.49 Standard: >=

110(-3%) 277V 122.29

Page 6: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

6 / 16

2.2 Electrical, Photometric and Chromaticity Measurements

Test date 2019-01-24 Test Ambient: 25.2 º C

Test Orientation As intended Stabilization Time (min) 90

Model Number 203012-211-XXX

Electrical Measurement for Bare-lamp:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

JBE190106-I

1

120.0 60 0.1126 13.05 0.9658 17.41

277.0 60 0.0513 13.01 0.9160 21.54

Chromaticity Measurement - Sphere-Spectroradiometer Method:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 81 R9 2

Frequency (Hz) 60 R2 92 R10 82

CCT (K) 3027 R3 94 R11 78

Duv -0.0009 R4 78 R12 70

Chromaticity (x, y) x=0.4338 y=0.4008 R5 81 R13 84

Chromaticity (u’, v’) u'=0.2499 v'=0.5196 R6 90 R14 98

Color Rendering Index (CRI) 81.6 R7 81 R15 73

R9 2 R8 56 -- --

Photometric Measurement –Sphere-Spectroradiometer Method:

Parameter Result

Test Voltage (V) 120.0 277.0

Frequency (Hz) 60 60

Total Luminous (lm) 1501 1507

Luminous Efficacy (lm/W) 115.02 115.83

Worst Luminous/Highest Watts 115.02

Page 7: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

7 / 16

Spectral Power Distribution & Chromaticity Diagram

Page 8: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

8 / 16

2.3 Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

Test date 2019-01-24 Test Ambient: 25.2 º C

Test Orientation As intended Stabilization Time (min) 90

Model Number 203012-211-XXX

Electrical Measurement for 2-lamp in Lithonia C2 25 MVOLT GEB10IS:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

JBE190106-I

1,I2

120.0 60 0.2180 24.99 0.9554 17.82

277.0 60 0.0988 24.98 0.9123 21.81

Chromaticity Measurement - Sphere-Spectroradiometer Method for 2-lamp in

Lithonia C2 25 MVOLT GEB10IS:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 81 R9 4

Frequency (Hz) 60 R2 92 R10 83

CCT (K) 3031 R3 94 R11 78

Duv -0.0012 R4 79 R12 71

Chromaticity (x, y) x=0.4331 y=0.3999 R5 81 R13 84

Chromaticity (u’, v’) u'=0.2499 v'=0.5191 R6 91 R14 98

Color Rendering Index (CRI) 82.0 R7 81 R15 73

R9 4 R8 57 -- --

Photometric Measurement – Goniophotometer Method for 2-lamp in Lithonia

C2 25 MVOLT GEB10IS:

Parameter Result

Test Voltage (V) 120.0 277.0

Frequency (Hz) 60 60

Total Luminous (lm) 2639.7 2651.0

Luminous Efficacy (lm/W) 105.63 106.12

Worst Luminous/Highest Watts 105.63

Zonal lumens in the 0-60° zone (%) 67.9 --

Beam Angle (°) 118.8 --

Center Beam Candle Power (cd) 779 --

Page 9: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

9 / 16

Zonal Lumen Tabulation

Zonal Lumen Summary

Zone Lumens % Luminaire

0-30 604.9 22.9%

0-40 992.6 37.6%

0-60 1,791.2 67.9%

60-90 701.5 26.6%

70-100 436.8 16.5%

90-120 120.0 4.5%

0-90 2,492.7 94.4%

90-180 146.8 5.6%

0-180 2,639.5 100%

Lumens Per Zone

Zone Lumens % Total Zone Lumens % Total

0-10 73.7 2.8% 90-100 68.8 2.6%

10-20 211.1 8.0% 100-110 20.9 0.8%

20-30 320.0 12.1% 110-120 30.3 1.1%

30-40 387.7 14.7% 120-130 16.7 0.6%

40-50 409.7 15.5% 130-140 7.4 0.3%

50-60 388.8 14.7% 140-150 2.0 0.1%

60-70 333.5 12.6% 150-160 0.4 0%

70-80 237.2 9.0% 160-170 0.2 0%

80-90 130.8 5.0% 170-180 0.1 0%

Spectral Power Distribution & Chromaticity Diagram

Page 10: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

10 / 16

Photometric Data

Page 11: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

11 / 16

Page 12: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

12 / 16

2.4 Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

Test date 2019-01-24 Test Ambient: 25.2 º C

Test Orientation As intended Stabilization Time (min) 90

Model Number 203012-215-XXX

Electrical Measurement for Bare-lamp:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

JBE190106-I

3

120.0 60 0.1138 13.12 0.9604 17.93

277.0 60 0.0520 13.10 0.9087 21.89

Chromaticity Measurement - Sphere-Spectroradiometer Method:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 80 R9 0

Frequency (Hz) 60 R2 89 R10 73

CCT (K) 5046 R3 94 R11 80

Duv 0.0015 R4 81 R12 61

Chromaticity (x, y) x=0.3441 y=0.3537 R5 81 R13 83

Chromaticity (u’, v’) u'=0.2099 v'=0.4856 R6 84 R14 97

Color Rendering Index (CRI) 82.1 R7 85 R15 74

R9 0 R8 63 -- --

Photometric Measurement – Sphere-Spectroradiometer Method:

Parameter Result

Test Voltage (V) 120.0 277.0

Frequency (Hz) 60 60

Total Luminous (lm) 1594 1602

Luminous Efficacy (lm/W) 121.49 122.29

Worst Luminous/Highest Watts 121.49

Page 13: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

13 / 16

Spectral Power Distribution & Chromaticity Diagram

Page 14: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

14 / 16

2.5 Performance Assessment:

Model name CCT(K) Total Luminous

(lm) Power (W)

Luminous

Efficacy (lm/W)

203012-211-XXX 3000K 1501 13.05 115.02

203012-212-XXX 3500K 1524*1

13.09*2

116.42*3

203012-213-XXX 4000K 1548*1

13.09*2

118.26*3

203012-215-XXX 5000K 1594 13.12 121.49

*1: This value is calculated and the calculation formula is as below:

1524= (1594-1501)/4*1+1501

1548= (1594-1501)/4*2+1501

*2: This value is calculated and the calculation formula is as below:

13.09= (13.05+13.12)/2

*3: This value is calculated and the calculation formula is as below:

116.42= 1524/13.09

118.26= 1548/13.09

Page 15: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

15 / 16

3. Test Equipment

Equipment ID Equipment Name Last Calibration Date Next Calibration Date

ST-R-702 2 meter Integrating Sphere Verified by D204 standard lamp

ST-R-701 Spectral analysis system HAAS-2000 Verified by D204 standard lamp

ST-R-705 Standard Lamp 2018-02-08 2019-02-07

ST-R-704 Power Meter for Integrating Sphere 2019-01-06 2020-01-05

ST-R-714 Goniophotometer system Verified by D908S standard lamp

ST-R-710 Standard Lamp 2018-02-13 2019-02-12

ST-R-711 Power Meter for Goniophotometer 2019-01-06 2020-01-05

Uncertainty:

Photometric Measurement (Sphere):1.74%

Chromaticity Measurement(Sphere):14.3K

Photometric Measurement(Goniophotometer):1.62%

Page 16: LM-79-08 Test Report Revolution Lighting Technologies, Inc. · “A” = Trade Agreements Act (TAA) - Compliant “USA” = Buy American Act (BAA) - Compliant Blank = Non-USA Manufacturing

Ningbo TengLi Testing Co., Ltd

2nd floor, Block B, Ningbo Testing and Certification Base, No. 66

Qingyi Road, Ningbo National Hi-Tech Zone, Ningbo, Zhejiang

Tel: 86574-8783 6802

Fax: 86574-8783 5902

Report No.: JBE190106-I

Report Format Number STD/QP019-409-A/0-NB

http://www.standard-tech.com

16 / 16

4. Product Photo

****** END OF REPORT ******