Method -1 Transfer of loading from Nozzle to Dishend junction to flange face INPUT VALUES Fa 61.6 kN FL 61.6 kN FC 46.2 kN MT 185.1 kN-m MC 135 kN-m ML 160.3 kN-m L 2077 mm M 3007 mm Moment and Forces for Flange Desi F 46200 N M1 146189 N-m M2 370331 N-m Resultant Moment 398141 N-m Fl Fl Fl Fc Fc Fc L Fa MT Ml Mc Fa Fa M L M Fl Fc MT Ml Mc Fa FcxL FaxM FlxL FlxM FcxL FaxM Mc FlxL Ml Mt FlxM

Loading Transfer From Noazzle Junction to Flange Face

Embed Size (px)

Citation preview

Page 1: Loading Transfer From Noazzle Junction to Flange Face

Method -1Transfer of loading from Nozzle to Dishend junction to flange face

INPUT VALUES

Fa 61.6 kNFL 61.6 kNFC 46.2 kNMT 185.1 kN-mMC 135 kN-mML 160.3 kN-mL 2077 mmM 3007 mm

Moment and Forces for Flange Design

F 46200 NM1 146189 N-mM2 370331 N-mResultant Moment 398141 N-m

Fl

Fl

Fl

Fc

Fc

Fc L

Fa

MT

MlMc

Fa

Fa

M

L

M

FlFc

MT

Ml

Mc

FaFcxL

FaxM

FlxL

FlxM

FcxL

FaxM

Mc FlxL

Ml

MtFlxM

Page 2: Loading Transfer From Noazzle Junction to Flange Face

Method-2Transfer of loading from Nozzle to Dishend junction to flange face

Fa1 =Fa 61.6

Mt=Mt1 185.1

Ml1 =Ml + Fl *L 288.2432 Ml is +ve,When Fa to Fl

Mc1 = Mc -Fc*L 39.0426 Mc is +ve When Fc to Fa

Fc2 =Fc1 46.2

Ml2 =Ml1 288.2432Mt2=Mt1+Fl*M 370.3312 Mt is +ve,When Fl to FcMc2=Mc1-Fa*M -146.1886 Mc is +ve,When Fc to Fa

output values Moment and Forces for Flange Design

F 46.2 KNM1 370.331 KN-mM2 -146.19 KN-m

Resultant Moment 398.14 KN-m

Fc

Fa

Fl

Mc

Ml

Mt

Fc1

Fa1

Fl1

Mc1

Ml1

Mt1

Fc2

Fa2

Fl2

Mc2

Ml2

Mt2

L

M