    CommercialFor

    To provide a variety of accessible and inviting areas that attract

    opportunities for outdoor dining, socializing, and relaxing in

    commercial areas to enrich the pedestrian environment.

    Standards

    1.1.1 All developments shall incorporate publicly accessible open

    space on-site. This could include a single public open space or, for

    larger developments, a variety of pedestrian-

    oriented space(s) as described in 1.1.2.

    Specifically,

    applicants must successfully demonstrate

    how the proposed publicly accessible

    open space meets all of the following

    criteria:

    a. Is/are centralized and accessible. All

    applicable open spaces shall be

    physically and visually accessible from the adjacent street or major

    internal pedestrian route. Open spaces shall be in centralized

    locations that nearby business, and/or customers can use rather

    than simply left-over or undevelopable space in locations wherevery little pedestrian traffic is anticipated. Locations integrated

    with transit stops, for instance, would be encouraged, as there is

    likely to be pedestrian traffic in the area. At least 50 percent of the

    open space shall be at street level.

    b. Is/are inviting. Inviting open spaces feature amenities and

    activities that encourage pedestrians to use and explore the space.

    Elements and amenities could include a fountain, sculpture,

  • 8/11/2019 Location and space requirements.docx

    3/18

    3

    3

    childrens play area, special landscaping element, benches and

    other seating areas, and pedestrian-scaled lighting.

    oriented spaceExample of pedestrian

    c. Is/are safe. Safe open spaces incorporate Crime Prevention

    Through Environmental Design (CPTED) principles:(1) Natural surveillancewhich occurs when parks or plazas are

    open to view by the public and neighbors. For example, a plaza that

    features residential units with

    windows looking down on space means that the space has good

    eyes on the park or plaza.

    (2) Lighting that reflects the intended hours of operation.(3) Landscaping and fencing. Avoid configurations that create

    dangerous hiding spaces and minimize views

    .

  • 8/11/2019 Location and space requirements.docx

    4/18

    4

    4

    Guidelines for creating

    safe open spaces.

    (4) Entrances should be prominent, well lit, and highly visible frominside and outside of the space.

    (5) Maintenance. Open spaces shall utilize durable materials that

    will last and require minimal maintenance costs. Walls, where

    necessary, shall be designed and treated to deter graffiti as

    indicated in section 2.4, Blank Wall Treatment. Use and maintain

    landscape materials that reduce maintenance cost and maintain

    visibility, where desired

  • 8/11/2019 Location and space requirements.docx

    5/18

    5

    5

    1.1.2 Standards and descriptions of pedestrian-oriented

    spaces: These are predominately hard-surfaced, plaza or

    courtyard type spaces that are encouraged with commercial

    buildings. To qualify as a pedestrian-oriented space, an area

    shall have:

    Pedestrian access to the abutting structures from the street,

    private drive, or a nonvehicular courtyard.Paved walking surfaces of either concrete or approved unit paving.

    Other materials maybe be proposed as long as they meet the

    Americans with Disabilities Act.

    Pedestrian-scaled lighting (no more than 15 feet in height) at a level

    averaging at least 2 foot candles throughout the space is required

    unless other site lighting meets the minimal lighting level

    requirement. Lighting may be on-site or building-mounted lighting.At least 2 linear feet of seating area (bench, ledge, etc.) or one

    individual seat per 60 square feet of plaza area or open space (up to

    50% of seats may be moveable).

    Be sited in areas with significant pedestrian traffic to provide

    interest and security, such as adjacent to a building entry.

    Integrated Landscaping features that add interest to the space.

  • 8/11/2019 Location and space requirements.docx

    6/18

    6

    6

    The following features are encouraged in pedestrian-oriented

    spaces:

    Pedestrian amenities, such as a water feature, drinking fountain,

    tables, and/or distinctive paving or artwork.

    Pedestrian-oriented building facades on some or allbuildings

    facing the space.

    Consideration of the sun angle at noon and the wind pattern in the

    design of the open space.

    Transitional zones along building edges to allow for outdoor eating

    areas and a planted buffer.

  • 8/11/2019 Location and space requirements.docx

    7/18

  • 8/11/2019 Location and space requirements.docx

    8/18

    8

    8

    Maximum setback f rom street

    1.For development sites narrower than 150 an alternative sitedesign maybe proposed. Should building placement be greater

    than 85 from the right of way, a pedestrian oriented

    monumentation must be placed adjacent to the sidewalk.

    2.In single building developments not located at the street, the

    building will have an 85 maximum setback. For multiplebuilding developments, at least half of the buildings must meet

    the 85 maximum setback requirement.

    3. 1.2.2 To meet the definition of a pedestrian-oriented facade,a facade must include the following elements:

    4.a. The primary pedestrian entrance shall be located on thisfacade.

    5.b. The ground floor facade between 2 and 8 feet above theground shall contain a minimum of 75 percent transparent

    window area.

    6.c. Weather protection at least 4-1/2 feet in depth and at

    least 8 feet above the ground along a minimum of 75 percent of

    the facade.

  • 8/11/2019 Location and space requirements.docx

    9/18

    9

    9

    .Pedestrian-oriented

    facades

    example.

    1.2.3Buildings

    within 5 feet of a public street shall feature a pedestrian-oriented

    facade (as defined in Standard 1.2.2). Exceptions:

    a. For buildings fronting on two public streets, the minimum

    percentages of weather protection and window transparency

    shall be reduced from 75% to 50% on the buildings secondary

    facade (as determined by the responsible official).

    b. Porches and covered entry features may project up to the front

    property line adjacent to a public street, unless otherwise

    noted.

    c. Primary pedestrian entrance is not required along this facade.

  • 8/11/2019 Location and space requirements.docx

    10/18

    10

    10

    Commercial buildings shall be located and oriented towards

    the street. Parking lots may not be located between the street

    and the building except as allowed in section 1.2.1 and listed

    below:

    a. For sites that front on more than one public street, the

    development shall orient to both streets.

    b. Development shall incorporate design features that maintain

    visual continuity along the streets.

    c. Where unique topographical or environmental conditions make

    conformance difficult or undesirable, the responsible official shall

    allow alternative commercial building placement and/or

  • 8/11/2019 Location and space requirements.docx

    11/18

    11

    11

    orientation, provided the overall development meets the Intent of

    the standards

    For industrial building

    industrial building means a building used for the carrying out of

    an industrial process and includes a building used for the carrying

    out of such a process on land used as a dock, harbour or quay for

    the purposes of an industrial undertaking and land used for

    research and development of products or processes, but does not

    include a building on land in or adjacent to and occupied together

    with a mine;

    a) the height of any part of the new building erected would exceed-if within ten metres of a boundary of the curtilage of the

    premises, five metres;

    in all other cases, the height of the highest building within the

    curtilage of the premises or 15 metres, whichever is lower;

    (b) the height of the building as extended or altered would exceed-

    if within ten metres of a boundary of the curtilage of the

    premises, five metres;

    in all other

    (c) any part of the development would be within five metres of any

    boundary of the curtilage of the premises;

    If the height limits set out under (a) or (b) above are exceeded, or if

    any part of the development is within 5 metres of any boundary of

    the curtilage of the premises, then development is not permitted andan application for planning permission will be required.

  • 8/11/2019 Location and space requirements.docx

    12/18

    12

    12

    The curtilage of premises will normally comprise the area of land

    surrounding the premises. It will, however, vary according to

    individual circumstances and in some cases, may not comprise all of

    the area of land in which the premises sit. Professional advice may

    therefore need to be sought on what defines the curtilage in a

    particular case.

    When measuring the height of the highest building within the

    curtilage, that height should be calculated as the height of the ridge

    line of the main roof (even if there are roofs with ridge lines at a

    lower or higher level) or the height of the main roof where roofs on

    a building are flat or mono-pitched.

    Any protrusions or other development (such as chimneys, flues,

    plant and machinery and antennae) above the roof should not be

    taken into account when considering the height of the highest

    building within the curtilage. However, when calculating the height

    of any building being erected, extended or altered, the measurement

    should be to the highest part of the new building, extension, or

    alteration and should include any protrusions above the roof.(d) the gross floor space of any new building erected would exceed

    100 square metres;

    (e) the gross floor space of the original building would be exceeded

    by more than-

    (i) 10% in respect of development on any article 1(5) land or

    25% in any other case; or

    (ii) 500 square metres in respect of development on any article1(5) land or 1,000 square metres in any other case;

    whichever is the lesser;

  • 8/11/2019 Location and space requirements.docx

    13/18

    13

    13

    for housing

    There has been growing concern that the internal space of new

    dwellings may be getting smaller. There is evidence that less family

    size housing is being provided. There is however concern that

    internal space within both family and non-family homes may also

    be reducing. This has implications for both accessibility and forsustainability and for quality of life including health. In addition

    there is a relationship between size of units

    and affordability

    Trends in Space Standards

    Over the last 90 years, a number of attempts have been made to

    define minimum space standards in public sector provision. The

    approach has become progressively more sophisticated over theyears, progressing through number of rooms, minimum floor

    space for rooms and the dwelling as a whole, to functional/activity

    based requirements. The Parker Morris Report (1961) is still the

    most commonly cited benchmark for space

    standards amongst practitioners, in England and elsewhere in the

    UK, although it is a benchmark that neither the public nor private

    sectors seek to achieve. The amount of space provided in privateand public sector housing has ebbed and

    flowed. Space standards have been set as part of the various

    publicly-funded housing programmes instituted over the decades,

    not as general requirements applicable to all

    sectors through the Buildings Regulations or planning system. As

    new space standards are introduced or updated, public sector

    standards improve for a while but then tail off. Private sectorstandards are influenced by these changes and show a similar

  • 8/11/2019 Location and space requirements.docx

    14/18

    14

    14

    pattern of ebb and flow, although less pronounced. In the absence

    of controls, developers (both public and private sector) will tend to

    reduce the size of dwellings being developed whilst trying to

    minimise any reduction in

    value. Studies indicate a pattern of increased cramming of rooms

    (such as additional bathrooms) into dwellings leading to smaller

    habitable rooms and significant reductions in storage space.

    We note that data is not collected on dwelling or room sizes as part

    of the process of obtaining planning permissions or Building

    Control approval, and there is therefore very

    limited data available on these dwelling characteristics apart from

    specificallycommissioned research. We recommend that such datais collected to allow future

    studies or reviews to be built on a more extensive database.

    Requirements for Residential Zones.

    Chart of Site Requirements.

    (1) Purpose. The Site Requirements Chart establishes basic

    dimensional standards for residential development. The

    standards and rules are established to maintain a consistent and

    compatible land use pattern throughout Redmond and to

    provide flexibility in project design, maintain privacy between

    adjacent uses, and prevent public nuisances.

  • 8/11/2019 Location and space requirements.docx

    15/18

    15

    15

    (2) Explanation of Chart. The Site Requirements Chart is

    arranged in a matrix format. Site requirement categories are

    listed down the left side of the chart, and residential zones are

    identified across the top of the chart. The matrix cells contain

    the minimum or maximum dimensional requirements for each

    zone.

    Allowed Density.

    (1) Purpose. The allowed density requirement helps to

    maintain a consistent and compatible land use pattern in

    Redmonds residential neighborhoods. Other purposes of this

    requirement are to serve the planned housing needs ofRedmonds residential population, and prevent public nuisances

    that result from a lack of adequate open space and the over

    utilization of public facilities.

    (2) Requirements. The allowed density, as shown for each

    residential zone in the Site Requirements Chart represents the

    maximum number of dwelling units that may occupy an acre of

    land, exclusive of bonuses.

    (3) Calculations. When calculating allowed density for any

    given site in the City, the gross area of the site is multiplied by

    the allowed density per acre that applies to the zone where the

    site is located. The result is the maximum number of units that

    may occupy that site. For the purposes of this calculation,

    fractional values shall be rounded to the nearest whole numberAverage Lot Size.

    (1) Purpose. The average lot size requirement allows for the

    development of consistent and compatible land use patterns

    throughout Redmonds residential neighborhoods. This

    requirement also minimizes public nuisances that may result

    from a lack of adequate open space and the over utilization of

    public facilities.

  • 8/11/2019 Location and space requirements.docx

    16/18

    16

    16

    Minimum Lot Width Circle.

    (1) Purpose. The minimum lot width circle ensures that each

    lot is wide enough to maintain a consistent and compatible land

    use pattern in residential neighborhoods. Although not intended

    to define the final buildable area where a residential structure

    must be sited, the minimum lot width circle is intended to

    ensure that a minimum buildable area is included in each lot

    created. This requirement also provides for the adequate

    separation of residences, thereby helping to reduce the threat of

    public nuisances that may result when a lot is too narrow.

    Minimum Lot Frontage.

    (1) Purpose. The

    minimum lot frontage is designed

    to prevent congestion by allowing

    for on-site parking and to reduce

    public nuisances that result

  • 8/11/2019 Location and space requirements.docx

    17/18

    17

    17

    from an inability of emergency vehicles to access a building

    either because vehicles block the access to a residence or

    because the lot is not wide enough to allow emergency vehicles

    to enter from the street.

    Building Setbacks.

    (1) Purpose. Front, rear, side/interior, and side street setbacks

    help maintain a consistent and compatible land use pattern for

    Redmonds residential neighborhoods. Setback requirements

    also provide for adequate light and air to all properties,

    minimize incompatibilities such as excessive light and noise, and

    prevent public nuisances such as the potential for fire damage

    from buildings constructed too close to each other.

    (2) Requirements.

    (a) Lot Orientation. For the purpose of applying setback

    regulations, the following shall be applied: the front shall be

    toward the street or access corridor from which the lot is

    addressed; the rear is opposite to the front or as nearly so as

    the lot shape permits; and the sides are 90 degrees to the

    front or as nearly so as the lot shape permits.

  • 8/11/2019 Location and space requirements.docx

    18/18

    18

    18

    Minimum Open SpaceLandscapingBuffers.

    (1) Purpose. The minimum open space requirement maintains

    community character by providing visual relief, open space,

    adequate outdoor space for residents of residentialdevelopments, and enhanced public safety by providing

    adequate off-street recreation space for children.

    References

    www.uctc.net