Lone Star Blower
Standard Specifications
Materials of ConstructionEnclosure .................... Fabricated carbon steelImpeller ...................... 5 axis machined anodized 7075 aluminumShaft ............................ Titanium alloy with Sm2CO17 magnetsCasing.......................... A356 cast aluminumBearing type ................ Journal style foilBearings ...................... X-750 teflon coated InconelFinish of enclosure ...... Powder coated
Technical Data
Outlet connection ........ 8” ANSI #150Blow off connection .... 5” ANSI #150Weight ........................ 1254 lbs.Maximum RPM ........... 33,400Cooling ........................ Internally air cooledTemp range.................. 14°F to 104°FSound level.................. 75 dB @ 3 feet free fieldInlet filter ..................... ASHRAE Std. 52.1Mounting ..................... Adjustable feet with anchor
Electrical Data
Motor type................... Permanent magnet synchronous motorInsulation class ........... HMotor HP rating........... 100Full load amps ............. 120Voltage ........................ 460V, 3 PH, 60HzVFD.............................. Yaskawa or KEBController .................... MI-COM processor (PLC optional)Communication ........... Ethernet, Modbus RTU, Modbus TCP,
Hardwiring
Options
Dust tight/sealed enclosureHigh and low ambient temperature Separated electrical and mechanical enclosureStainless steel enclosureFlanged intake connectionAlternative voltageOutdoor enclosure
Patents / Certifications
Manufactured by TurboMax 10-0675821, 10-0781298, 10-0870887CE-TUV K1747/E09, K1480/M09UL-ULC 508A, 1446, 1004ISO 9001
MAX100-C080
MAX100-C080
General Performance
Standard Conditions (68°F, 36% RH, 14.7 psia)
16
14
12
10
8
6
4
2
0
Syst
em d
iffer
entia
l pre
ssur
e - p
si
600 800 1000 1200 1400 1600 1800 2000 2200 2400
Flow at standard conditions – SCFM
120
80
40
0
Pow
er –
hp
Max Power
Max FlowMin Flow
Min Flow
Max Flow
LONE STAR BLOWER
+1 832 532 3112 +1 832 532 3115 Fax [email protected]
LSB0615
MAX100-C080 Discharge Size Blow-off Size Total Weight
8” 5” 1254 lbs.
Note: It is recommended that the blow off air discharge is piped to the outside using piping similar to Figure AA. The discharge air tempera-ture can reach a maximum of 175°F. Dimensions and specifications may change without notice.
BLOWERCONTROLLER
B
D
A
5" BLOW-OFF(BLOW-OFF AIR DISCHARGE)
E E
INLET LOUVER/AIR FILTER
POWER CABLE/GROUNDCABLE INLET
MCCB &HANDLE
8" ADAPTER
View D(right side)
View C(front side)
View A(rear side)
View E-E(top side) View B
(left side)