CASSOWARY PL
POINCIANA AVE
LOT 134B
LOT 37C
LOT 38C
LOT 133A
LOT 135A
LOT 36C
LOT 35A
LOT 136B
C
C
240LV
4s/l
Ex.L17
C
240LV
4s/lC
240LV
4s/l
24011kV
240LVSC2213409315kVA
C
240LV
C
24011kV240LV
C
24011kV240LV
16LV240LV
16LV
240LV
LOT 39A
LOT 40B
LOT 41C LOT 132
B
LOT 131C
LOT 129B
LOT 130A
LOT 109B
LOT 93A
LOT 94C
LOT 108-
LOT 107B
LOT 106A LOT 105
B LOT 104A
LOT 95A
LOT 110-
LOT 42B
ROAD X'ING 25.0m
ROAD
X'ING
20.0m
ROAD
X'IN
G 24
.0m
ROTATE SL POLE 90° TO HAVEPANEL AWAY FROM TRAFFIC
& AWAY FROM DRAIN
ROTATE SL POLE 90° TO HAVEPANEL AWAY FROM TRAFFIC
& AWAY FROM DRAIN
ROTATE SL POLE 90° TO HAVEPANEL AWAY FROM TRAFFIC
& AWAY FROM DRAIN
ATTN: CIVIL CONTRACTOR1500x900 RCBC SW WITH 675mm COVER. INSTALL ELECTRICAL CONDUITS UNDER
STORM WATER
ATTN: CIVIL CONTRACTOR1500x900 RCBC & 900x450 RCBC SW
WITH 455mm COVER. INSTALL ELECTRICAL CONDUITS UNDER
STORM WATER
1
DANGER
CABLESLIVE LV & HV
Ex
Ex
240LV
240LV 240LV
Ex
LOCATE & EXTENDEXISTING CONDUITS
LIVE LVCABLES
DANGER
2
SP1C
240LV
3
SP1C 240
LV
240LV
6
D240LV
4CABLEMARKERPLATE
ROAD XING
H C 240LV
5
H
C
240L
V
LP2231028(CLOSED)
10
D
240LV78
CABLEMARKERPLATE
P
4s/l24
0LV
9
9LL17
13
11
H
C
240LV
D
J
C
240LV
CABLEMARKERPLATE
12
H
C240LV
14
SP1C
GREV
ILLEA
WAY
15
SP2 C
16
D
17D
240LV D
240L
V 18
CABLEMARKERPLATE
18LL17
E 240L
V24
0LV
D
240L
V
19
29
CABLEMARKERPLATE
D
240LV
D
240LV
28
28LL17
20
CABLEMARKERPLATE
E
240LV240LV
21
REFER SHEET
REFER SHEET 21A
A
SCALE 1:1000PLAN VIEW
1 : 1000 (A1 - NOT REDUCED)
-20m 0 20 40 60m
LEGEND: ELECTRICAL
STATION NUMBERS
STREET LIGHT, EXISTING / PROPOSED / FUTURE
LV LINKS (OPEN), EXISTING / PROPOSED / FUTURE
"ENERGEX ELECTRIC CABLE" MARKER PLATE
LINK PILLAR, EXISTING / PROPOSED / FUTURE
HV POLE, EXISTING / PROPOSED / FUTURE
HV + LV POLE, EXISTING / PROPOSED / FUTURE
PROPOSED OVERHEAD ELECTRICITY MAINS
EXISTING OVERHEAD ELECTRICITY MAINS
LV POLE, EXISTING / PROPOSED / FUTURE
EXISTING UNDERGROUND CABLE
SERVICE PILLAR, EXISTING / PROPOSED / FUTURE
PROPOSED UNDERGROUND CABLE
12
TO BE RECOVERED
CABLE, EXISTING / PROPOSED
EXISTING NPL 3 STREETLIGHT CABLE
PROPOSED NPL 3 STREETLIGHT CABLE
EXISTING CONSUMERS UNDERGROUND CABLE
PROPOSED CONSUMERS UNDERGROUND CABLE
C
32/40mm HD CONDUIT
80/100mm LD CONDUIT
125mm LD CONDUIT
100mm WHITE ENERGEX COMMS. CONDUITC
FUTURE UNDERGROUND CABLE
BORED CONDUIT12L
L17
RING MAIN UNIT, EXISTING / PROPOSED / FUTURER
CABLE FAULT INDICATOR
C
R
C
R
PADMOUNT TRANSFORMER,EXISTING / PROPOSED / FUTURE
POLE TRANSFORMER,EXISTING / PROPOSED / FUTURE
LV LINKS (CLOSED),EXISTING / PROPOSED / FUTURE
FUTURE OVERHEAD ELECTRICITY MAINS
EARTH, EXISTING / PROPOSED / FUTURE
FUTURE NPL 3 STREETLIGHT CABLE
NPL 3 STREET LIGHT,EXISTING / PROPOSED / FUTURE
NPL 3 SWITCHBOARD, EXISTING / PROPOSED
to be provided by:
to be installed by:to be owned by:
to be designed by:civil & electrical contractorsRobin Russell & Associates
TELECOMMUNICATIONS INFRASTRUCTURE
CONDUITS & PITS
TELECOMMUNICATIONS INFRASTRUCTURE
ROCK EXCAVATION BY ELECTRICALCONTRACTOR
The electrical contractor shall:· excavate electricity trenches to the depth required,· excavate street light foundations to a depth of 1500mm,
The works detailed on this drawing shall be constructed in accordance with Robin Russell & Associates'General Specification for Installation of Electricity Reticulation and Street Lighting - Issue 'AA'.
Robin Russell & Associates gives no warranty regarding the presence or location of buried services,including newly-installed services. "As Constructed" locations may differ from what is drawn on thisworks plan. Contractors shall be responsible to identify and locate all buried services. Initialidentification can be obtained from:
Dial Before You Dig ServiceTelephone 1100Fax 1300 652 077On-line enquiries can be made at: http://www.1100.com.au.
Having determined which services may be present, on-site locations should then be arranged withrelevant service authorities.Sewerage and water plans for the subdivision may be obtained on request from the Superintendent.
ELECTRICAL CONTRACTOR
ON-SITE SERVICES CHECKS
The installation of all electrical conduits shall be supervised by the holder of an electrical work licence -Electrical Safety Act 2002.Energex conduits and transformer site retaining walls shall be installed strictly in accordance withEnergex's specifications (see below). They will be inspected for compliance upon completion.Where road-crossing conduits are installed deeper than usual (under culverts or pipes) they must rise to adepth of not more than 1200mm at each end. If uncertain, seek advice from RRA Construction Coordinator.The civil contractor shall install enveloping conduits under retaining walls behind pillars - two 100mmconduits into each lot (one for Electricity, one for Communications), 500mm deep behind the pillar, nearground level inside the lot.Relevant specifications in Energex's Underground Distribution Construction Manual are found at - Section C1: Conduits
Section C2: ExcavationSection C3: Transformer Sites
These sections of the manual can be downloaded from the following Energex web site:https://swp.energex.com.au/service_providers/technical_docs/asp/technical_documents.aspCivil engineers who have registered for access to the following RRA website may download extracts fromEnergex's manual at:
http://www.robrus.com.auThe civil contractor shall ensure that all conduits have been installed before constructing retaining walls,paths, driveways & water services. The civil contractor shall please inform the electrical contractor of any'as constructed' departures from the civil design.
CIVIL CONTRACTOR
In the event of conflict between this works plan and drawings and specifications of the relevant futureasset owner, i.e. Energex, Ergon, local authority, Department of Transport & Main Roads, NBNTM, etc.,the drawings and specifications of the future asset owner shall take precedence. Exceptions applywhere RRA design documentation specify clearances, depths & separations greater than the minimumrequired by the authorities.The contractor shall not accept a verbal instruction from any person to depart from the requirements ofthis works plan or RRA General Specification. Any departure from the works plan or specification mustfirst be authorised in writing by the Contract Superintendent.
GENERAL NOTES
Care: Existing street lights shall not be recovered unless replacement street lights willbe commissioned before nightfall. Lighting of new or altered existing roads might notcomply with specified standards until new road lighting has been commissioned. Thecivil contractor shall apply appropriate risk management. e.g. warning signs, speedrestrictions, temporary lighting, etc.
Telecoms conduits and pits shall be supplied and installed by the civil and electrical contractors as specifiedon the associated RRA works plan.
INSTALLATION OF RRA DESIGNED TELECOMMUNICATIONS CONDUITS
In residential subdivisions, Telecommunications conduits shall be installed generally in shared trenches,directly above the electrical conduits.In commercial subdivisions or other situations where this is not possible, Telecommunications conduits shallbe installed in a separate trench on the specified communications alignment.
TOTAL NUMBER OF LOTS
PROPERTY DESCRIPTION
SITE INFORMATION
26
LOTS 38-41, 93-109 & 129-133CANCELLING LOT 461 on SS58
D176-01S0106792 3
PARKLANDS AT CLARENDON STAGE 2ACLARENDON RDRIFLE RANGE
PARKLANDS AT CLARENDON Pty Ltd
W.Schardt
The Drafting Room
6/5/2021
WCS47.1
SOMERSET REG
DA5613
UBD REF
COUNCIL REF
COUNCIL
SPECIFICATIONENERGEX
AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
DESIGNED
DRAWN
SIGNED
DATE
CLIENT
DESCRIPTION LOCATION
APPROVED BYMap Grid
ENERGEX PROJECT No.
DRAWING No.
OF
SHEET No.
ROBIN RUSSELLRPEQ 1546
A1CDWT REV
Stafford, QLD 4053204/6 Babarra Street,
Fax: (07) 3872 5566Tel: (07) 3872 5555
Email: [email protected]& ASSOCIATES PTY. LTD.
RobinRussellCONSULTING ENGINEERS - ELECTRICAL
www.robrus.com.auA.B.N. 78 010 589 661
REVDATE REVISION APP. DATE REV APP.REVISION CURRENT REVISION CHANGES: SUBDIVISIONELECTRICAL SERVICES A6/5/2021 A PRELIMINARY ISSUE RR
V53-2 20210412
- ELECTRICITY RETICULATION -RESIDENTIAL
1
SOURCE DOCUMENTSCREATOR DRAWING REV. NO.DWG. NO. DATE
INERTIA ENGINEERING CIVIL BASE 9365-xc_base - 25/3/2021
ROBIN RUSSELL & ASSOC ELECTRICAL D175 B 7/10/2020
"AS CONSTRUCTED" DOCUMENTSThe electrical contractor shall email the "as constructed" drawing,test results & closure documents to:
· [email protected]· [email protected]
UNDERGROUND CABLE CERTIFICATION
Certified (signature of checker): _______________________________
Serial No: ____________ Date Cables Checked: _____/_____/_____
Name of Person Who Conducted Checks: _______________________
Make: ____________________ Model: _______________________
Phone No. of checker: ______________________________________
All cables detailed on this drawing have been checked using thecable locator described below and are, according to measurementstaken, on the correct alignment and at correct depths below thefinished level, except as marked up. Alignments are subject to theaccuracy of survey pegs present at the time of measurement.
ROAD LIGHTING CERTIFICATE
ELEMENT DETAILS
(Design documentation in accordance with the requirements ofAS/NZS 1158.3.1 Appendix E)
The maintenance factor and maintenance regime are theresponsibility of the Asset Owner (Energy Queensland).
This design utilises the following maintenance factors:
0.7 for IP5x and 0.75 for IP6x luminaires as specified by EnergyQueensland.
Note: Luminaires and lamps shall be replaced with exact equivalents.
Robin Russell RPEQ 1546
ROAD LIGHTING MAINTENANCE SCHEDULE
INSTALLATION ARRANGEMENT / GEOMETRYArrangement Mounting HeightOutreachUpcast AngleSpacing
-----
LUMINAIRE / LAMP DETAILSLuminaire TypeLamp TypeDesign LumensI Table No.
----
LIGHT TECHNICAL PARAMETERS
LUMINAIRE / LAMP DETAILSOrigin of Luminaire Data
ROAD SURFACE REFLECTION CHARACTERISTICS
COMPUTER PROGRAM DETAILSName of Computer ProgramSource of programCompliance
---
-
FLAG LIGHTING - STREET LIGHTS INSTALLED ATINTERSECTIONS, END OF CUL-DE-SACS & BENDS IN ROADS ASPER SOMERSET REGIONAL COUNCIL DA5613 (DATED21/8/2019) CLAUSE 2.29.
varies (refer drawing)varies (refer Lighting Schedule)varies (refer Lighting Schedule)0°N/A
Avenue L17 (IP66)15W LED1899Modular LED 15W 4K 170326PHM.cie
Gerard Lighting Australia
As per Somerset Regional Council specifications.
R3
N/AN/AN/A
CIVIL ENGINEERINERTIA ENGINEERING
BRENDEN ADAMS ph: 3857 7868
SURVEYORMINSTAFF SURVEY
MICHAEL KOSCHEL ph: 4637 9790
ELECTRICAL ENGINEERROBIN RUSSELL & ASSOCIATES PTY LTDDESIGNER
CONSTRUCTION CONTACTS
CONSTRUCTION COORDINATOR
WILLIAM SCHARDT ph: 0419 778 552
SHANE HYDE ph: 0419 021 772
ATTN: CIVIL CONTRACTORTHE CIVIL WORKS SHALL BE CONSTRUCTED TO CONFORM
TO ENERGEX SPECIFICATIONS, AS FOLLOWS:
· MAXIMUM CROSS SLOPE OF UNDERGROUND CABLEALIGNMENT IS 1:4, UP TO 1.6m FROM THE BOUNDARY.
· MAXIMUM GRADE AT PILLAR LOCATIONS IS 1:4, UP TO1.6M FROM THE BOUNDARY
· FINISHED LEVELS AT ALL STREET LIGHT LOCATIONSSHALL BE AT THE SAME GRADE AS THE SHOULDERWITH CONCRETE REINFORCEMENT WITHIN THE SWALEDRAIN, AS PER THE "TYPICAL LIGHT POLE PROTECTIONDETAIL" SHOWN ON THE CIVIL DESIGN.
· CROSS ROAD PILLAR LOCATIONS & THE PILLAR ATSTN.14 (LOT 109) SHALL BE SHAPED TO ACHIEVE A PAD1.6m WIDE X 1.6m DEEP, AT A MAXIMUM GRADE OF 1:4WITH CONCRETE REINFORCEMENT WITHIN THE SWALEDRAIN, AS PER THE "TYPICAL ELECTRICAL PILLARPROTECTION DETAIL" SHOWN ON THE CIVIL DESIGN.
THE ABOVE ITEMS HAVE ENERGEX APPROVAL & SHALL NOTBE ALTERED WITHOUT PRIOR ENERGEX APPROVAL.
BITUMENS/LIG
HT
SOMERSET REGIONAL COUNCILSTREET LIGHT ALIGNMENT
NTS
GRAVELSHOULDER
EDGE OFBITUMEN
1300mm
BATTEREOB
LILLY
PILL
Y PL
GREVILLEA WAY
#62
LOT 20RP138053
LOT 36C
LOT 26B
LOT 27A
LOT 28B
LOT 29A
LOT 34B
LOT 35A
LOT 140A
LOT 139C
LOT 138C
LOT 137CLOT 136
B
REFER SHEET
REFER SHEET 21
A
A
ROTATE SL POLE 90° TO HAVEPANEL AWAY FROM TRAFFIC
& AWAY FROM DRAIN
240LV
16LV
240LV
4s/l240LV
ExL17
240LV
240L
V
INSTALL4 STEELBOLLARDS
240LV
16LV
16LV240LV
4s/l
ExL17
240LV 240LV
16LV
240LV
LOT 105B LOT 104
A
LOT 103B
LOT 102C
LOT 95A LOT 96
C
LOT 97B
LOT 98C
LOT 99B
LOT 100A
LOT 101C
ROTATE SL POLE 90° TO HAVEPANEL AWAY FROM TRAFFIC
& AWAY FROM DRAIN
ROTATE SL POLE 90° TO HAVEPANEL AWAY FROM TRAFFIC
CABLEMARKERPLATE
E
240LV240LV
21
REFER SHEET
REFER SHEET 21A
A
D
240LV
D
16LV
27
22LP2231036(OPEN)
23
D240LV
D
16LV
26
D 240L
V
24LL17
24
LOCATE & EXTENDEXISTING CONDUITS
240L
V
240LV
240LV
25
LIVE LVCABLES
DANGER
POINCIANA AVE
22LL17
EX
EX
EX
D176-02S0106792 3
PARKLANDS AT CLARENDON STAGE 2ACLARENDON RDRIFLE RANGE
PARKLANDS AT CLARENDON Pty Ltd
W.Schardt
The Drafting Room
6/5/2021
WCS47.1
SOMERSET REG
DA5613
UBD REF
COUNCIL REF
COUNCIL
SPECIFICATIONENERGEX
AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
DESIGNED
DRAWN
SIGNED
DATE
CLIENT
DESCRIPTION LOCATION
APPROVED BYMap Grid
ENERGEX PROJECT No.
DRAWING No.
OF
SHEET No.
ROBIN RUSSELLRPEQ 1546
A1CDWT REV
Stafford, QLD 4053204/6 Babarra Street,
Fax: (07) 3872 5566Tel: (07) 3872 5555
Email: [email protected]& ASSOCIATES PTY. LTD.
RobinRussellCONSULTING ENGINEERS - ELECTRICAL
www.robrus.com.auA.B.N. 78 010 589 661
REVDATE REVISION APP. DATE REV APP.REVISION CURRENT REVISION CHANGES: SUBDIVISIONELECTRICAL SERVICES A6/5/2021 A PRELIMINARY ISSUE RR
V53-2 20210412
- ELECTRICITY RETICULATION -RESIDENTIAL
2
SCALE 1:1000PLAN VIEW
1 : 1000 (A1 - NOT REDUCED)
-20m 0 20 40 60m
LOCATIONCONDUIT BENDING RADIUS (mm)
HORIZONTAL BEND
PILLAR - MAIN CABLE
100mm Ø 125mm Ø
PILLAR - X-ROAD CABLE
PILLAR - STREET LIGHT CABLE
STREET LIGHT
600 1830 1830
POLE TERMINATION
TRANSFORMER
- 1200 -
- 450 -
600 - -
300 - -
300 1200 1830
no bends required
40mm Ø
TRENCH DETAIL"SP2"(N.T.S.)
1x100 MD ENERGEX COMMS
TRENCH DETAIL"SP1"(N.T.S.)
PROJECT SPECIFICNON-STANDARD TRENCH DETAILS
C1x125 LD ELECTRICAL
1x100 MD ENERGEX COMMS3x100 LD ELECTRICAL
1x125 LD ELECTRICALC
3x100 LD ELECTRICAL
PROP
ERTY
SID
E
ROAD
SID
E
PROP
ERTY
SID
E
ROAD
SID
E
D176-03S0106792 3
PARKLANDS AT CLARENDON STAGE 2ACLARENDON RDRIFLE RANGE
PARKLANDS AT CLARENDON Pty Ltd
W.Schardt
The Drafting Room
6/5/2021
WCS47.1
SOMERSET REG
DA5613
UBD REF
COUNCIL REF
COUNCIL
SPECIFICATIONENERGEX
AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
DESIGNED
DRAWN
SIGNED
DATE
CLIENT
DESCRIPTION LOCATION
APPROVED BYMap Grid
ENERGEX PROJECT No.
DRAWING No.
OF
SHEET No.
ROBIN RUSSELLRPEQ 1546
A1CDWT REV
Stafford, QLD 4053204/6 Babarra Street,
Fax: (07) 3872 5566Tel: (07) 3872 5555
Email: [email protected]& ASSOCIATES PTY. LTD.
RobinRussellCONSULTING ENGINEERS - ELECTRICAL
www.robrus.com.auA.B.N. 78 010 589 661
REVDATE REVISION APP. DATE REV APP.REVISION CURRENT REVISION CHANGES: SUBDIVISIONELECTRICAL SERVICES A6/5/2021 A PRELIMINARY ISSUE RR
V53-2 20210412
- ELECTRICITY RETICULATION -RESIDENTIAL
3
Refer: Energex's Underground Distribution Construction Manual - Section C3 for specifications.The Electrical Contractor shall cut & reinstate the concrete surround.
SCALE 1:50 (AT A1 SIZE)EXISTING SC2213409 (STN 1)
LV HV
EARTH GRIDLOT 134LOT 135 EA
SEME
NTEASEMENT
EX
C
24011kV
4s/l
240LV
POINCIANA AVE
240LV
1.2m to driveway 1.2m to driveway
DRIVEWAY
240LV 240LV16LV
16LV
240LV
EX EX EX
EX
240LV
PROPOSED COMMISSIONING PLANTentative only; subject to amendment by ENERGEX outage coordinator.
LV Switching x 2
Description of switching:Bridge in & comission 240 LV UG at SC2213409 & U2229258 Poinciana Way
Where interruptions to existing consumers are required, they shall be notifiedin line with ENERGEX policies.
LABELSThe contractor shall check label details against existing labels on site.Report any discrepancies immediately to the Contract Superintendent.
LABELSIZE
LETTERSIZECOLOUR
LABEL
80x35 5WB
TRANSFORMER ISOLATOR80x35 WB 6
AT POINCIANA AVE (STN 1) SC2213409LABEL INFORMATION
LV SWITCHBOARD LABELSNo.
CIRCUIT
TRANSF.
1
ISOLATOR
80x35
80x35
5
5
WB
WB
3
2
4 WB 580x35
[EXIST]
TO POINCIANA AVE LP2229262 / GREVILLEA WAY LP2231036 & SERVICES
TO POINCIANA AVE LP2231028 & SERVICES
[EXIST]
TO GREVILLEA WAY LP2231036 & SERVICES
AT POINCIANA AVE (STN 5) LP2231028
SIZECOLOUR
5WB
DIRECTION
CABLE
SIZE
STN 3TOWARDS 150x50
5WBTOWARDSSTN 12
CABLE150x50
LABEL INFORMATIONLETTERCIRCUIT LABEL LABEL
TO POINCIANA AVE SC2213409 & SERVICES
LV LINK PILLAR LABELS
TO POINCIANA AVE SC2213409 / GREVILLEA WAY LP2231036 & SERVICES
AT POINCIANA AVE LP2229262
SIZECOLOUR
5WB
DIRECTION
CABLE
SIZE
U2213391TOWARDS 150x50
5WBTOWARDSSTN 25
CABLE150x50
LABEL INFORMATIONLETTERCIRCUIT LABEL LABEL
[EXIST]
LV LINK PILLAR LABELS
TO POINCIANA AVE LP2231028 & SERVICES
AT GREVILLEA WAY (STN 22) LP2231036
SIZECOLOUR
5WB
DIRECTION
CABLE
SIZE
STN 25TOWARDS 150x50
5WBTOWARDSSTN 21
CABLE150x50
LABEL INFORMATIONLETTERCIRCUIT LABEL LABEL
TO POINCIANA AVE SC2213409 \ LP2229262 & SERVICES
LV LINK PILLAR LABELS
POINCIANA AVE C
U2213405 240AL
SC2213409315kVA
240AL
U2213403
240A
L
U2213401
BOTTLEBRUSH CR
240ALU2213400
240AL
U2213393
BOTTLEBRUSH CR 240AL
U2213392
240AL
POIN
CIAN
A AV
E
CLARENDON RD
EXISTING & PROPOSEDLV SCHEMATICSCALE 1:2500 AT A1
240AL
P172329(CLOSED)
U2213404
U2213390
240AL
U2229257240AL
240A
L
LILLY
PILL
Y PL
U2229269
U2229258
GREVILLEA WAY
POINCIANA AVE240AL
240A
L
LP2229262(OPEN)
240A
L
U2213391
U2229255
SEPARATELY EARTHED TRANSFORMERSC2213409 Poinciana AveThis transformer is separately earthed.Do NOT connect any HV earths to LV neutral.
240AL6
U2231029
240AL
3U2231027
240AL
CLOSELINKS
5 LP2231028(CLOSED)24
0AL9
U2231030
12U2231031
240AL
240AL
CASSOWARY PL
14U2231032
240AL 18U2231034
240A
L
29U2231042
28U2231041
240AL 240AL
21U2231035
240AL 22LP2231036(OPEN)
LINKSOPEN
240AL
25
1 TFMR IS
315A
315A
CCT1 CCT2 CCT3 CCT4
240m
m
TRAN
SFOR
MER
315A
315A
LAYOUT FOR SC2213409 (STN 1)LV SWITCHBOARD
240m
m
240m
m
240m
m