Introduction
Thank you for your interest in the Lourdes High School Auditorium. This document is intended to serve as an introduction to the physical and technical specifications of the stage and surrounding areas of Lourdes High School. It is to be used as a general guide to the facilities and equipment of the main auditorium and surrounding spaces. It is by no means a “last word”; some equipment may be under repair, lost, damaged, or replaced. Any questions may be directed to the House Manager or Fine Arts Department Chair for clarification.
Companion Website
http://lourdesauditorium.weebly.com/
Contains digital versions of this document, separate appendix documents, various equipment manuals, and a photo album.
Table of Contents Information.........................................................................................................................................4
General................................................................................................................................................5
Policies................................................................................................................................................6
Load-InFacilities.................................................................................................................................7
Carpentry............................................................................................................................................7
RiggingInformation............................................................................................................................8
Lighting................................................................................................................................................9
VideoProjection...............................................................................................................................11
Audio.................................................................................................................................................12
BlackBox...........................................................................................................................................16
Misc.Equipment...............................................................................................................................17
Appendices.......................................................................................................................................18
4
Information Managed by:
Rochester Catholic Schools Lourdes High School
Mailing Address
2800 19th Street NW Rochester, MN 55901
Web Address
http://www.rcsmn.org/
Main Office Phone
(507) 289-3991
Lourdes High School Fine Arts Personnel
Robert S.P. Gardner, Fine Arts Chair Email: [email protected]
Zach Sander, Band Director
Email: [email protected] Brynn Llewellyn-Boyd, Choral Director
Email: [email protected]
Patty Arndt, House Manager Email: [email protected]
Neil Stiller, Technical Consultant
Email: [email protected] Matthew Walther, Technical Consultant Email: [email protected]
5
General Ticket Office
The ticket office is located at the main entrance of the Auditorium in the Fine Arts lobby area. It has one counter station that may be opened to service patrons in the lobby area. The ticket office is also the house manager’s office.
Handicapped Access
Handicapped restrooms are available in the dressing rooms and in the Fine Arts lobby area. ADA compliant elevators are available for access to the control booth and orchestra pit. Stage, dressing rooms, and make-up room are handicapped accessible, located at ground level. There are 3 dedicated wheelchair locations for audience members on the main floor. Handicapped parking spots are located near the Fine Arts building entrance (north lot).
Parking
Parking is available in front of the auditorium in the north parking lot (see diagram in Appendix G). Large vehicle parking is available in the same lot or behind the school gym depending on event timing and volume. Additional parking is available in the south lot and east lot behind the school.
Make-up Room
The make-up room has 15 stations and a common hand sink. Each station has a duplex outlet and lighted mirror.
Dressing Rooms
Dressing rooms are accessed through the make-up room off of the backstage hallway. Each of the two 13’ 5” x 15’ 9” dressing rooms has a single occupancy bathroom connected with toilet and hand sink. No showers are available.
6
Policies
It is in best interest to make sure that all who use Lourdes High School facilities are aware of rules and regulations to avoid any issues. All users of the Fine Arts facilities will be subject to facility use agreements identifying specific rules and responsibilities. The following are minimum requirements. In the case of discrepancy between documents, the facility use agreement contract shall supersede this document.
• The Auditorium is located within Lourdes High School. All Rochester Catholic Schools campuses are both smoke-free and alcohol-free. Smoking and alcoholic beverages are strictly prohibited.
• The user shall be responsible for all set-up, clean-up, damage repairs and security.
• Decorations must be temporary and approved by school representative prior to display. Removal is required immediately following the event.
• Lourdes High School reserves the right to disallow events that are not consistent with the Catholic identity of the school.
• Any intended use of naked flames, pyrotechnics, smoke, fog, haze, or strobes must be notified to the Manager at least two (2) weeks prior to load in. This same policy applies to the use of flammable liquids and material such as straw. Permission is at the sole discretion of Lourdes High School.
• The painting of sets and scenery should be completed prior to load in. By prior arrangements some painting may be allowed in the Scene Shop. Painting will not be allowed on stage apart from minor touch ups, and only then if the stage floor is protected.
• Any lighting fixtures brought into the Auditorium for use on stage must be complete with safety cable and be in compliance with electrical regulations. This also applies to any portable equipment used in the Auditorium, i.e. P.A. equipment, light fixtures, and any other portable electrical equipment. Appropriate compliance is determined at the discretion of Lourdes High School Personnel. The Auditorium and Black Box use three-prong stage pin connectors for all dimmable fixtures.
• All flats, scenery, drapes, costumes and props etc. must be fireproofed prior being to used in the Auditorium. In accordance with Minnesota State Fire Code 807.4.2.1, foam plastics MAY NOT BE USED within the building.
Food and Beverage
• Food and refreshments shall not be served in any area of the school facility other than the Commons (cafeteria).
• Food is not permitted in the Lourdes High School Auditorium control booth, dressing rooms, on stage, or public seating area.
• Only water in enclosed/non-spill containers, no larger than one (1) liter, will be permitted in the Auditorium.
• A food service company under contract with Lourdes High School reserves exclusive catering/food-service rights for the Lourdes High School facility. No other forms of catering/food-service (commercial or private) may be used unless otherwise agreed upon in writing by the user, Lourdes High School, and the food service company.
7
Load-In Facilities Scene Shop Dock
Entrance is at ground and stage level. As this area is also the theatre’s scene shop, an appropriate path will be cleared for load-in. Garage doors between driveway, scene shop, hallway, and stage measure 10ft wide and 12ft tall. The stage garage door is located Up Stage Left and the scene shop is directly across the hallway with matching door/ceiling height minimum.
Loading Dock
Truck-trailer level loading dock is available in rear of school between gym and Commons (cafeteria). This option should only be used if necessary as equipment must be transported all the way through the main corridor of the school in order to reach the Auditorium. Prior arrangements must be made for use of this option. This corridor is generally locked, restricting access.
Carpentry Seating
Left Side 57 Left Main 191 Left Rear 50 Right Rear 50 Right Main 193 Right Side 57 Max Seating 598
Stage Dimensions
Proscenium Width 48’ Proscenium Height 20’ Proscenium Wall Thickness 1’ Apron Width 56’ 6” Apron Depth 5’ 8” Stage height from audience floor 30" Width, stage edge to edge 53’ Depth, Curtain line to back wall 33’ 1” Depth, Curtain line to last batten 29’ 6” Offstage Space Width, Stage Left 10’ Offstage Space Depth, Stage Left 30’ 3” Offstage Space Width, Stage Right 12’ Offstage Space Depth, Stage Right 33’ 1” Usable floor area- Stage 1753 ft2
Stage Floor
The stage floor is made of wood planks. The color is flat black. Lagging into the stage floor is prohibited.
House Drapery
Grand Drape- Beige, manually operated from Stage Left via nylon rope. Can be drawn laterally or flown in and out as needed.
Midstage Traveler- Black, manually operated from Stage Left via nylon rope. Can be drawn laterally or flown in and out as needed.
Rear Traveler- Black, manually operated from Stage Left via nylon rope. Can be drawn laterally or flown in and out as needed.
8
Stained Glass
Four 12.5’ x 13.5’ stained glass panels line each side of the auditorium. The stained glass is separate from the exterior walls, which have their own corresponding clear glass windows. All exterior windows in the auditorium have automated blinds to block out all daylight, which are operated from the control booth.
Rigging Information Type
The counterweight system is a hand operated, single purchase system with the lock rail located on Stage Left. Battens are 2” outside diameter pipe, 63’ long with 7 1/4” 7x19 strand lift cables spaced 10’ apart. Load capacity of each line arbor is 1565 lbs.
Line Set Schedule
Set # House Hang Distance from Proscenium 0 Front Wall 0’ 0” 1 Grand Valence 0’ 10” 2 Grand Drape 1’ 6” 3 1st Electric (31 Circuits) 2’ 10” 4 1st Leg 4’ 2” 5 Scenery Batten* 4’ 10” 6 1st Border 6’ 2” 7 2nd Leg 8’ 2” 8 2nd Border 10’ 10” 9 2nd Electric (17 Circuits) 12’ 2” 10 3rd Leg 14’ 2” 11 Scenery Batten* 16’ 10” 12 Midstage Traveler 18’ 2” 13 3rd Border 18’ 10” 14 Scenery Batten* 20’ 10” 15 4th Leg 22’ 10” 16 4th Border 23’ 6” 17 3rd Electric (23 Circuits) 24’ 10” 18 Scenery Batten* 26’ 2” 19 Scenery Batten* 26’ 10” 20 Rear Traveler 28’ 2” 21 Cyclorama 29’ 6” Rear Wall 33’ 1” *Scenery Battens are freely available for approved use. Any other battens are not available for scenery pieces without prior approval.
Loading Gallery
The loading gallery is located on Stage Left and is reached by a ladder from the main catwalk system. Weights are available in 1” (21.73 lb) and 2” (43.46 lb) varieties both on the stage floor and the loading gallery. Access is restricted.
9
Lighting Dimming 2- Electronic Theatre Controls Sensor3 240V Installation Racks
1- Electronic Theatre Controls DRd Paradigm Control (House Lighting)
Control Console ETC Element 60. 250/500 Channels. Two DMX outputs.
Circuit Distribution
Circuits Area Controlled Dimmers 30 Catwalk 1-30 6 Audience Left Forward Stained Glass Bay 34-39 6 Audience Left Rear Stained Glass Bay 43-48 6 Audience Right Forward Stained Glass Bay 31-36 6 Audience Right Rear Stained Glass Bay 40-45 32 1st Electric 49-80 18 2nd Electric 81-98 24 3rd Electric 99-122 2 Downstage Left Wall 129-130 2 Downstage Right Wall 130-131 2 Upstage Left Center Wall 132-133 2 Upstage Right Wall 133-134 2 Upstage Left and Downstage Right Floor 135-136 2 Downstage Left and Upstage Right Floor 137-138 3 Orchestra Pit Stage Left 139-141 3 Orchestra Pit Stage Right 141-143 Permanent House Lighting- Up-Lights 154-155 Permanent House Lighting- Stained Glass Backlights 157-166 Permanent House Lighting- Stage Work Lights 167-169 Permanent House Lighting- Stage Edge Safety Lighting 164 Permanent House Lighting- Seating Safety Lights 156 Permanent House Lighting- Side Seating Overhead 170-171 Permanent House Lighting- Main Seating Overhead 172-183
10
Fixture Inventory
Quantity Type 29 ETC Source Four PAR 8 ETC Source Four Ellipsoidal 14˚ 24 ETC Source Four Ellipsoidal 19˚ 7 ETC Source Four Ellipsoidal 26˚ 24 ETC Source Four Ellipsoidal 36˚ 10 ETC Source Four Zoom Ellipsoidal (15˚-30˚) 6 Selecon Rama 160 6" Fresnel 24 ETC Selador Vivid-R 11” LED (floor and pipe mounts for each) 24 Vivid H40 Lens 24 Vivid V40 Lens 4 Altman Fresnel 65Q 2 Misc. Ellipsoidal (Curtain Warmers) 3 Altman Scoop 161 (16”) 4 Altman Scoop 160 (14”) 1 Altman Comet Follow Spot (Edison) 1 Altman 1000Q Follow Spot (Edison) 1 Lycian Stage Lighting Super Arc 400 Follow Spot (twist lock) 2 ETC Net3 DMX Gateway
Lighting Lenses Available
Type 7” Clear Par Lens 7” Diffused Par Lens 7” Frosted Par Lens H40 Vivid-R 11” LED Lens V40 Vivid-R 11” LED Lens
Cabling Inventory
Quantity Type 11 5ft Stage Pin Extension Cable 4 10ft Stage Pin Extension Cable 2 15ft Stage Pin Extension Cable 2 20ft Stage Pin Extension Cable 30 10ft 5-pin DMX Cable 1 20ft 5-pin DMX Cable 1 100 meter CAT5e Cable 1 20 meter CAT5e Cable - Assorted Ethernet Patch Cables
11
Video Projection Projector Epson PowerLite Pro Z8350WNL Switching Extron IN1606 Scaling Presentation Switcher Inputs
- Presentation Desktop Computer in Control Booth (VGA) o Dual Monitors o Microsoft Office o Internet Access o DVD Drive
- Downstage Right HDMI/VGA Input Panel - HDMI Input on Control Booth Counter
Screen
- Motorized 12’ 6” H x 19’ 8” W Projection Screen (Downstage of Grand Drape) - Cyclorama (Rigging Line 21)
12
Audio Control Location
- Main mixer is located in the Control Booth - Access to equipment and additional control panels in Control Booth
Wiring
Downstage Right Edge -Lecture Mic 1 -Mic 1 -Mic 2 -Out 1 -COM
Downstage Right Wall -Mic 26 -COM -VIDEO IN (VGA/HDMI)
Upstage Right Wall -Mic 23 -Out 8 -COM
Downstage Left Edge -Lecture Mic 3 -Mic 5 -Mic 6 -Out 3 -COM
Downstage Left Wall -Mic 25 -COM -ETC Net3 (Lighting Control Network)
Upstage Center Wall -Mic 24 -COM
Downstage Center Edge -Lecture Mic 2 -Mic 3 -Mic 4 -Out 2 -COM
Pit Upstage Right -Mic 7 -Mic 8 -Mic 9 -Mic 10 -Mic 11 -Mic 12 -Out 4 -COM
Pit Upstage Left -Mic 13 -Mic 14 -Mic 15 -Mic 16 -Mic 17 -Mic 18 -Out 5 -COM
Catwalk Splitting Center -Mic 27 -Mic 28 (Both Used for Hanging Recording Microphones)
Pit Downstage Center -Mic 19 -Mic 20 -Out 6 -COM
Pit Downstage Left -Mic 21 -Mic 22 -Out 7 -COM
1st Electric -8 XLR Input -4 XLR Output (Terminates at Main Snake in Dimmer Room)
2nd Electric -8 XLR Input -4 XLR Output (Terminates at Main Snake in Dimmer Room)
Make-up Room -COM Base Station
Hearing Assistance System
The Auditorium is equipped with a Listen Technologies FM hearing assistance system. All seats in the Auditorium are capable of receiving the main audio mix. Four (4) headsets are available upon request, though may not be available for all performances. The Listen System works on the 72 MHz frequency.
13
Production Communication 1- Telex Audiocom 2 Channel Base Station MS-2002 8- BP-2002 Dual Channel Belt Pack 8- 30’ Intercom Connection Cables 8- Single Muff Headsets Backstage Feed
In ceiling speakers are installed in backstage and stage right hallways, band room, choral room, black box, and make up rooms. When in use, backstage feed is broadcast in all of these areas; use may be prohibited if additional activities are taking place in those areas. Backstage feed can contain a mix of the following: main audio mix, message repeater, PA output from intercom system, and an auxiliary output from the mixing console.
Lobby Feed
In ceiling speakers are installed in Fine Arts Lobby area, bathrooms, and stage left hallway. When in use, lobby feed is broadcast in all of these areas. Lobby feed can contain a mix of the following: main audio mix, and message repeater.
Lecture System
The Lecture System runs independently of the main audio mixer. All control for the lecture system is accomplished with Biamp Audia “Volume/Select 8” control panels. Identical panels are located on the downstage right wall and in the control booth. Inputs controlled by these panels include Lecture Mic 1, Lecture Mic 2, Lecture Mic 3, Wireless Mic 1, Wireless Mic 2, Video Projection Switcher Audio, and building paging feed. Wireless microphone inputs are compatible with either handheld or body pack transmitters, with either headset or lavaliere microphones.
Processing Structure
The Lecture System, with its respective control panels, is directly processed with a Biamp Audia Flex system. The main program audio inputs are wired to digital snake units, located in the dimmer room and control room, that are connected directly to the main audio mixer in the control room. The main left, center, and right outputs of the mixer are then sent to the Biamp Audia Flex system. The Audia Flex sends the outputs of the lecture and/or main program systems to the under balcony amplifier and a pair of loudspeaker system processors, located in the dimmer room, where the main left, center, and right signals are individually split between high, mid, and sub frequency ranges before being sent to the amplifiers and speakers.
14
Equipment Inventory Mixing Console
1- Roland M-480 Digital Mixing Desk; 48 input channels; 16 aux buses; 8 matrices; main LCR; 4-band parametric EQ, delay, compressor, and gate on inputs and outputs; 31 band GEQ on each main and auxiliary output; 8 local xlr inputs; 8 local xlr outputs; 1 pair RCA inputs.
Snakes
1- Roland S-4000S-3208 Digital Snake; 32 XLR inputs; 8 XLR outputs; permanently installed in dimmer room; receives input jacks around stage, 1st electric stake, and 2nd electric stake; outputs aux outs to output jacks around stage.
1- Roland S-1608 Digital Snake; 16 XLR inputs; 8 XLR outputs; permanently installed in control room; receives wireless microphone inputs, catwalk microphones, CD Player, and recorder playback; outputs to recorder.
2- Pro Co StageMASTER 150’ Analog Snake; 8 XLR inputs; 4 XLR outputs; permanently installed on 1st and 2nd Electric for use with hanging microphones above stage
1- 50’ Analog Snake; 16 XLR inputs; 2 TRS returns; 2 TS returns; stored in orchestra pit for running additional input lines from on stage into the input panels in the pit.
Processing 1- Biamp Audia Flex 2- Electro-Voice Dx46 Sound System Processor Amplification 5- Electro-Voice CPS 2.12 Power Amplifier; mains 1- Electro-Voice PA 2550T Power Amplifier; rear and side in-ceiling speakers 2- Atlas AA120R Mixer Amplifier Speakers - Main Speakers (3): EV Xi-2123A/106F Dual 12-Inch Three-Way, Full-Range 100° x 60° - Main Subwoofers (3): EV Xi-1191AF 18-Inch Subwoofer - Side Seating In Ceiling Speakers: EV EVID C8.2 8-inch two-way coaxial - Rear Fill In Ceiling Speakers: EV EVID C8.2HC 8-inch two-way coaxial - Monitoring: Electro-Voice ZXA-1 Powered Speakers Playback 1- Tascam CD-200i CD Player and 30 pin iPod Dock 1- Tascam SS-R100 Digital Flash (SD/CF/USB) Memory Recorder and Player
15
Wireless 12- Electro-Voice RE-2 Pro Receivers; Band A 4- Electro-Voice APD-4+ UHF Antenna/Power Distribution System 2- Electro-Voice LPA-500 Directional Log Periodic Antenna; Mounted on Catwalk 12- Electro-Voice WTU-2 Body Pack Transmitter 6- Electro-Voice PHTU-2 Pro Hand Held Transmitter; N/D767z Microphone Capsules 12- Electro-Voice RE-97TX Head Worn Condenser Microphone; beige 4- Electro-Voice RE-92TX Lavaliere Microphone; black ***Frequency Coordination for Lourdes Campus Attached as Appendix F*** Microphones
4- EV N/D478 instrument hand held dynamic cardioid 4- EV N/D767a vocal hand held dynamic super cardioid 2- EV N/D967vocal hand held dynamic super cardioid 6- EV RE20 dynamic cardioid large diaphragm 2- EV RE90H hanging microphones; permanently installed from catwalk for recording 6- Audio Technica Pro-45 Hanging Microphones 2- Audio Technica AT3030 small diaphragm condenser microphones 6- Audio Technica Pro-30 small diaphragm condenser microphones 1- Shure SM-81 small diaphragm condenser microphone 2- EV RE90P-18 gooseneck condenser microphones 1- Shure gooseneck podium microphone installed in presentation podium
16
Black Box General
Located behind the auditorium between the scene shop and dressing rooms, the black box theatre is a 44’ x 33’ multipurpose space with its own control room. Typical uses for the black box during a production in the main auditorium include as a green room, art gallery, and temporary storage area. The wood flooring surface is identical to the main auditorium stage. Black velour drapes are mounted on tracks 12’ high around the edge of the room and can be drawn to cover the block walls and exterior window.
Rigging
An overhead pipe grid is suspending above the central area of the black box floor for mounting of lighting and special effects.
Lighting Primary: Standard Fluorescent Tube Fixtures Dimming: Electronic Theatre Controls DRd Paradigm Control
Control Console: ETC SmartFade 2496. One DMX output.
Circuit Distribution: 21 separate circuits are located throughout the pipe grid. DMX outputs are also present.
Audio Mixing Console: Roland M-380 Digital Mixing Desk Snakes: Roland S-1608 Digital Snake; cat5e cables of various lengths available Amplification: Electro-Voice CPS 4.5 Power Amplifier Speakers: 4- EV ZX5 15” two-way full-range loudspeakers
Playback: Tascam CD-200i CD Player and 30 pin iPod Dock Wireless: 4- Electro-Voice RE-2 Pro Receivers; Band A 1- Electro-Voice APD-4+ UHF Antenna/Power Distribution System
(Wired and wireless microphones shared availability from main auditorium)
17
Miscellaneous Equipment The following equipment may be available for use, subject to the terms of the facility use agreement and by permission of the appropriate Fine Arts personnel. Orchestra Equipment
45- Wenger Black Student Chairs 90- Wenger Chrome Student Chairs 100- Black Music Stands 50- Wired Music Stand Lights 1- Wenger Conductor’s Music Stand 1- Wenger Conductor’s Podium
Acoustical Shell
9- Sections of Wenger Legacy Classic Acoustical Shell is stored in the Stage Right off stage area.
Instruments
1- Baldwin Concert Grand Piano 1- Yamaha Clavinova Electric Piano
Platforms
9- Wenger 4’x8’ Versalite Stage Platforms with multiple leg sizes. 8- Wegner Signature 3 Step Choral Risers
Lecterns
1- Large Podium with gooseneck Microphone 1- Medium Podium
18
Appendices (also available on companion website: http://lourdesauditorium.weebly.com/technical-info.html ) Appendix A:
T09 T08 T07 T06 T05 T04T10T12 T11T13 T03 T02 T01T15 T14T16
Q06 Q05 Q04 Q03 Q02 Q01Q07Q09 Q08Q10
R07 R06 R05 R04 R03 R02R08R10 R09R11
S07 S06 S05 S04 S03 S02S08S10 S09S11
R01
S01S12
R12
Q16 Q15 Q14 Q13 Q12 Q11Q17Q19 Q18Q20
R19 R18 R17 R16 R15 R14R20R22 R21R23
S19 S18 S17 S16 S15 S14S20S22 S21S23
T25 T24 T23 T22 T21 T20T26T28 T27T29
R13
S13
T19 T18 T17T31 T30T32
S24
R24
AA12
AA11
AA10
AA09
AA08
AA07
AA13
AA15
AA14
AA16
AA06
AA05
AA04
AA18
AA17
AA19
AA03
AA02
AA01
BB12
BB11
BB10
BB09
BB08
BB07
BB13
BB15
BB14
BB16
BB06
BB05
BB04
BB18
BB17
BB19
BB03
BB02
BB01
CC12
CC11
CC10
CC09
CC08
CC07
CC13
CC15
CC14
CC16
CC06
CC05
CC04
CC18
CC17
CC19
CC03
CC02
CC01
AA27AA28
AA29AA30
AA31AA32
AA26AA24
AA25AA23
AA33AA34
AA35AA21
AA22AA20
AA36AA37
AA38
BB27BB28
BB29BB30
BB31BB32
BB26BB24
BB25BB23
BB33BB34
BB35BB21
BB22BB20
BB36BB37
BB38
CC27CC28
CC29CC30
CC31CC32
CC26CC24
CC25CC23
CC33CC34
CC35CC21
CC22CC20
CC36CC37
CC38
N14 N13N08
N12 N10N11 N09
N04N05
N07 N06
P13 P12P08
P11 P09P10
P02P03
P04P05
P07 P06
N15N16N21
N17N19 N18
N20
N25 N24N22
N23
P14P15
P26
P19P16P18 P17
P25 P24 P23 P22P20
P21
N01N02
N03
P01
N28 N27 N26
B14 B13
B01
B08B12 B10B11 B09
B02B03
B04B05
B07 B06
C14 C13
C01
C08C12 C10C11 C09
C02C03
C04C05
C07 C06
D14 D13
D01
D08D12 D10D11 D09
D02D03
D04D05
D07 D06
E14 E13
E01
E08E12 E10E11 E09
E02E03
E04E05
E07 E06
F14 F13
F01
F08F12 F10F11 F09
F02F03
F04F05
F07 F06
G14 G13
G01
G08G12 G10G11 G09
G02G03
G04G05
G07 G06
H14 H13
H01
H08H12 H10H11 H09
H02H03
H04H05
H07 H06
A13 A12A07
A11 A09A10 A08
A02A03
A04A06 A05
J14 J13
J01
J08J12 J10J11 J09
J02J03
J04J05
J07 J06
K14 K13
K01
K08K12 K10K11 K09
K02K03
K04K05
K07 K06
L14 L13
L01
L08L12 L10L11 L09
L02L03
L04L05
L07 L06
M14 M13
M01
M08M12 M10M11 M09
M02M03
M04M05
M07 M06
B15B16
B28
B21B17B19 B18
B20
B27 B26 B25 B24B22
B23
C15C16
C28
C21C17C19 C18
C20
C27 C26 C25 C24C22
C23
D15D16
D28
D21D17D19 D18
D20
D27 D26 D25 D24D22
D23
E15E16
E28
E21E17E19 E18
E20
E27 E26 E25 E24E22
E23
F15F16
F28
F21F17F19 F18
F20
F27 F26 F25 F24F22
F23
G15G16
G28
G21G17G19 G18
G20
G27 G26 G25 G24G22
G23
H15H16
H28
H21H17H19 H18
H20
H27 H26 H25 H24H22
H23
A19A15A17 A16
A18
A23 A22A20
A21
J15J16
J28
J21J17J19 J18
J20
J27 J26 J25 J24J22
J23
K15K16
K28
K21K17K19 K18
K20
K27 K26 K25 K24K22
K23
L15L16
L28
L21L17L19 L18L20
L27 L26 L25 L24L22
L23
M15M16
M28
M21M17M19 M18
M20
M27 M26 M25 M24M22
M23
A24A01
A14
A25
Lourdes High School Auditorium Seating Chart
Revised By: Matthew Walther 2016
Total Number of Seats: 598 Fire Code Capacity: 609 Note: There is not a row I or row O
19
Appendix B: Lourdes Auditorium House Lighting Circuit Map
DN= Down Light UP= Up Light BL= Back Light WRK= Work Light
25
Appendix F: Lourdes High School Wireless Microphone Frequency Coordination
Appendix G: Lourdes High School Campus Map
Location(in(Building label/(receiver#/(description Frequency Group(# Channel(#Gym Wireless(mic(1 654.600 1 3Gym Wireless(mic(2 651.200 1 2Gym RF(Mic((receiver(in(gator(box)Forum Wireless(mic(1 648.300 3 1Forum Wireless(mic(2 675.850 3 10Commons Wireless(mic(1 648.250 2 1Commons Wireless(mic(2 649.450 2 2Chapel Wireless(mic(1 658.250 5 4Chapel Wireless(mic(2 674.350 5 9Auditorium WRLS01 651.000 P PAuditorium WRLS02 650.700 P PAuditorium WRLS03 652.300 P PAuditorium WRLS04 655.300 P PAuditorium WRLS05 656.700 P PAuditorium WRLS06 661.900 P PAuditorium WRLS07 659.100 P PAuditorium WRLS08 670.700 P PAuditorium WRLS09 672.250 P PAuditorium WRLS10 673.225 P PAuditorium WRLS11 650.000 P PAuditorium WRLS12 649.100 P P
Prepared(By:(Matthew(Walther6/13/14