120
Cod. 191002221 Rev. A Ed.03/2017 e-MP Series MPA, MPR, MPD, MPV 50 Hz HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 Lenntech Tel. +31-152-610-900 Fax. +31-152-616-289 info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Lenntech

Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

  • Upload
    lyquynh

  • View
    242

  • Download
    7

Embed Size (px)

Citation preview

Page 1: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

Cod. 191002221 Rev. A Ed.03/2017

e-MP SeriesMPA, MPR, MPD, MPV

50 Hz

HIGH PRESSUREMULTISTAGE PUMPS ACCORDING TO ISO 5199

[email protected] Tel. +31-152-610-900www.lenntech.com Fax. [email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289

Lenntech

Page 2: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

2

Lowara, HYDROVAR, Xylect are trademarks or registered trademarks of Xylem Inc. or one of its subsidiaries.All other trademarks or registered trademarks are property of their respective owners

XylectTM

XylectTM is pump solution software with an extensive online database of product information across the entire range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories.

XylectTM can be available:

For more information, please, see page 115-117.

Page 3: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

3

CONTENTS

General introduction ........................................................................................................................5Design version .................................................................................................................................6General characteristics ......................................................................................................................7Identification code ............................................................................................................................9Identification code and design overview .......................................................................................10 Rating plate .................................................................................................................................11Pump cross-section and main components .................................................................................12Table of materials .......................................................................................................................16Mechanical seals ..........................................................................................................................20Pressure/temperature limit ...........................................................................................................22Motors (ErP 2009/125/EC) ............................................................................................................24Pumps (ErP 2009/125/EC) ............................................................................................................32Hydraulic performance range at 50 Hz .........................................................................................33Operating characteristics at 50 Hz, 2 poles ..................................................................................34Operating characteristics at 50 Hz, 4 poles ..................................................................................54Dimensions and weights ..............................................................................................................67e-MP with HYDROVAR .................................................................................................................95Accessories ............................................................................................................................101Report and declarations .........................................................................................................105Technical appendix .................................................................................................................107

Page 4: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

4

e-MP SERIESHYDRAULIC PERFORMANCE RANGE AT 50 Hz, 2 POLES

HYDRAULIC PERFORMANCE RANGE AT 50 Hz, 4 POLES

Q [US gpm]20 30 40 50 60 70 80 90 200 300 400 500 600 700 800 900 2000 3000 4000100 1000

H [

ft]

500

750

1000

1500

1750

2000

2250

2750

3000

3250

1250

2500

Q [l/s]2 3 4 5 6 8 20 30 40 50 60 80 20010 100

H [

m]

100

200

300

400

500

600

700

800

900

1000

Q [Imp gpm]20 30 40 50 60 70 80 90 200 300 400 500 600 700 800 900 2000 3000100 1000

Q [m3/h]4 5 6 7 8 9 20 30 40 50 60 70 80 90 200 300 400 500 600 700 800 90010 100 1000

e-MP ~ 2950 [rpm] ISO 9906:2012

A000

5_A

_C

H

e-MP 50, 65, 100, 125, 150(~2950 rpm)

Q [US gpm]9 20 30 40 50 60 70 80 90 200 300 400 500 600 700 800 900 200010 100 1000H

[ft

]

0,2

0,3

0,4

0,50,6

0,8

2

3

4

56

8

20

30

40

5060

80

200

300

400

500600

800

0,1

1

10

100

Q [l/s]0,6 0,8 2 3 4 5 6 8 20 30 40 50 60 801 10 100

H [

m]

0

100

200

300

Q [Imp gpm]8 9 20 30 40 50 60 70 80 90 200 300 400 500 600 700 800 900 200010 100 1000

Q [m3/h]2 3 4 5 6 7 8 9 20 30 40 50 60 70 80 90 200 300 400 500 60010 100

e-MP ~ 1450 [rpm] ISO 9906:2012

A000

6_A

_C

H

e-MP 50, 65, 100, 125, 150(~1450 rpm)

Page 5: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

5

e-MP SERIESHIGH PRESSURE MULTISTAGE RING SECTION PUMPSMarkets and applications:

General industryAll productive industries, i.e. steel, sugar, timber, tire and rubber, pulp and paper, car, food and beverage.Applications: Cooling and heating circuits for industrial processes, sprinkler systems, washing/cleaning systems, firefighting systems, filter systems, water transport, booster systems, water treatment systems.

Oil and gason-shore platform, off-shore platforms, refineries, fracking.Applications: Transport of crude oil, sea water/water injection, firefighting systems, water transport, water tre-atment.

Power plants Renewable energy, hydropower, biomass, geothermal, fossil power.Applications: Boiler feed, condensate pumping, deaerator, water injection, water transport, auxiliary systems, firefighting systems, cooling and heating circuits, district cooling and heating system.

MiningApplications: Dewatering (filtered water), water transport, firefighting systems.

Agriculture Applications: water transport, irrigation.

Leisure industry i.e. skiing resorts, leisure parks, spas.Applications: snow making (feeding the snow canons), water transport, water boosting.

Public utilities i.e. water works, desalination plants, drainage and flood protection, tunnels.Applications: District cooling and heating systems, water transport, water treatment systems, desalinization, reverse osmosis, nanofiltration, firefighting systems, booster systems.

Commercial building service Applications: Water transport, booster systems, firefighting systems, HVAC systems.

Others i.e. Auxiliary applications in chemical Industry, all water boosting applications.Applications: Boiler feed, condensate pumping, deaerator, water injection, water transport, auxiliary systems, firefighting systems, cooling and heating circuits, district cooling and heating system.

Pumpable fluids:

Water Hot water Grey/used water Condensate Ground water Cooling/heating water Potable water Solvents Thermal water Lubricants Sea water in all regions Crude oil Brackish water Oil emulsions Feed water Fuels

Pumpable fluids:

The e-MP series is a highly efficient and flexible multistage ring section pump.4 mechanical models build the basic platform for various horizontal and vertical configurations to meet requirements for the defined markets, applications and liquids.

Page 6: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

6

e-MP SERIESDESIGN VERSIONS

CONFIGURATION DESCRIPTION

Model MPAClosed radial Impeller and U-turn diffuser design

•Horizontal shaft design• Axialsuctionnozzle• Radialdischargenozzle(left,top,right)• Driveondischargeside• Radial/Axialrollerbearingondriveside• Plainbearingonsuctionside• Axialthrustbalancingbydrumdesign• Shaftsealingondischargesideonly• Bareshaftorpumpunit• Driver:electricmotor-IECorNEMAstandard• IC-engine,turbine• Temperaturerange:(-25)-10°Cto140°C(180°C)• Inletpressure:upto10bar

Model MPR Closed radial Impeller and U-turn diffuser design

•Horizontal shaft design• Axialsuctionnozzle• Radialsuctionnozzle(left,top,right)• Radialdischargenozzle(left,top,right)• Driveondischargeside• Radial/Axialrollerbearingondriveside• Plainbearingonsuctionside• Axialthrustbalancingbydrumdesign• Shaftsealingondischargesideonly• Bareshaftorpumpunit• Driver:electricmotor-IECorNEMAstandard• IC-engine,turbine• Temperaturerange:(-25)-10°Cto140°C(180°C)• Inletpressure:upto10bar

Model MPD Closed radial Impeller and U-turn diffuser design

•Horizontal shaft design• Axialsuctionnozzle• Radialsuctionnozzle(left,top,right)• Radialdischargenozzle(left,top,right)• Driveondischargeside(optionalsuctionside)• Radial/Axialrollerbearingondriveside• Radialrollerbearingonsuctionside• Axialthrustbalancingbydrumdesign• Shaftsealingonsuctionanddischargeside• Bareshaftorpumpunit• Driver:electricmotor-IECorNEMAstandard• IC-engine,turbine• Temperaturerange:(-25)-10°Cto140°C(180°C)• Inletpressure:upto40bar

Model MPVClosed radial Impeller and U-turn diffuser design

• Vertical shaft design• Radialsuctionnozzle(0°-90°-180°-270°)• Radialdischargenozzle(0°-90°-180°-270°)• Driveondischargeside• Radial/Axialrollerbearingondriveside• Plainbearingonsuctionside• Axialthrustbalancingbydrumdesign• Shaftsealingondischargesideonly• Bareshaftorpumpunit• Driver:electricmotor-IECorNEMAstandardupto355kW(400kW)• Temperaturerange:(-25)-10°Cto120°C• Inletpressure:upto10bar

En-Rev_A

Page 7: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

7

e-MP SERIESGENERAL CHARACTERISTICS

MP_models-50-en_a_sc

OPERATING DATA

DATA VALUE

Mechanical sizes DN50toDN150

Power 2-pole operation: 7,5kW to 1.250kW (2-pole) / 10hp to 1.700hp4-poleoperation:2,2kWto250kW(4-pole)/3hpto220hp

Heads upto950m/3.100ft

Flows upto850m³/h/3.740USg.p.m

Temperature -25°Cto+140°C,optional180°C/-13°Fto+284°F,optional356°F

Operating pressures up to 100 bar / 1.450psi

En-Rev_A

Page 8: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

8

e-MP SERIESGENERAL CHARACTERISTICS

DN50 DN65 DN100 DN125 DN150

DN50 DN65 DN100 DN125 DN150

size

Operating range by size and design

size

40 bar580 psi

63 bar914 psi

100 bar1450 psi

25 bar363 psi

100 bar1450 psi

63 bar914 psi

40 bar 580 psi

25 bar363 psi

nom

inal

pre

ssur

e

Page 9: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

9

Pump Type [2 digits][MP] = Highly efficient and flexible multistage ring section pump, the new member of Xylem’s e-product range

Configuration [1 digit][A] = Horizontal design Axial suction, radial discharge 1 Roller bearing discharge side 1 Slide bearing suction side[R] = Horizontal design Radial suction and discharge 1 Roller bearing discharge side 1 Slide bearing suction side[V] = Vertical design Radial suction and discharge 1 Roller bearing discharge side 1 Slide bearing suction side[D] = Horizontal design Radial suction and discharge 2 Roller bearings, Double bearing

Optional configuration/design [1 digit][ ] = Standard[H] = Equipped with HYDROVAR [X] = Other Drives [M] = Multioutlet Pump

Diameter of discharge nozzle and hydraulic identifier [3 to 4 digits], e.g. 100B:Discharge diameter = 100 mm Hydraulic B for the size 100Note:Eachsizehas2hydraulics(AandB)tocover a wider range of flow at high efficencies.

Motor type [2 digits][P] = PLM[W] = WEG[X] = Other[-] = Motor not part of scope or supplied by customer

Motor power [2 to 5 digits] kW x 10, e.g.: [2000] = 200kW

N° of poles [1 digit][2] = 2 poles[4] = 4 poles

M P A 1 0 0 B / 0 4 A / B D 2 0 0 0 / W 2 5 V C C C 4

Combination of full and trimmed impellers [1 digit]:[A] = all impeller full diameter[B] = trimmed/full impellers combination 1 [C] = trimmed/full impellers combination 2 [D]=trimmed/fullimpellerscombination3[E] = trimmed/full impellers combination 4[X] = duty point trimmed

Frequency and power supply [2 digits] 50 Hz[5R]=3x220-240/380-415V[5V]=3x380-415/660-690V[5P]=3x200-208/346-360V[5S]=3x255-265/440-460V[5T]=3x290-300/500-525V[5W]=3x440-460/-[5X]= Other Voltage [5-] = Motor not part of scope or supplied by customer

60 Hz[6P]=3x220-230/380-400[6R]=3x255-277/440-480V[6V]=3x440-480/-[6U]=3x380-400/660-690V[6N]=3x200-208/346-360V[6T]=3x330-346/575-600V[6X]=Othervoltage[6-]=Motornotpartofscopeor supplied by customer

Material pumphousing: Suction, discharge and stage casing [1 digit][C] = Cast iron[D] = Ductile iron[F] = Cast steel[N]=Stainlesssteel[R] = Duplex[T] = Super duplex[X] = Others

Material impeller [1 digit][C] = Cast iron[B] = Bronze[N]=Stainlesssteel[R] = Duplex [T] = Super duplex[X] = Others

Materials mech seal + O-ring [1 digit][4] = Carbon/SiC/EPDM[2] = Carbon/SiC/FKM*[Z] = SiC/SiC/EPDM[W] = SiC/SiC/FPM[N]=Tungstencarbide/SiC/FKM*[X] = Others[-] = Soft packing* FPM (old ISO), FKM (ASTM & new ISO)

e-MP SERIESIDENTIFICATION CODE

EXAMPLES:Pump mounted on frame coupled with motorMPA100B/04A/BD2000/W25VCCC4Seriese-MP,horizontalconfiguration,axialsuctioninlet,radialdischargenozzle,sizeDN100,hydraulicB,4stages/impellers,allimpellerswithfulldiameter,16barsuctionnozzle,40bardischargenozzle,coupledwitha200kWmotorfromWEGwith2polesfor50Hz3x380-415/660-690Vsupply,framemounted,suctionanddischargecasing material made of cast iron, impellers and diffusers made of cast iron, mechanical seal Carbon/SiC, o-rings made of EPDM, mechanical seal.

Pump mounted on frame, with coupling, motor not part of scope or supplied by customerMPA100B/04A/BD2000/-25-CCC4 Seriese-MP,horizontalconfiguration,axialsuctioninlet,radialdischargenozzle,sizeDN100,hydraulicB,4stages/impellers,allimpellerswithfulldiameter,16barsuctionnozzle, 40 bar discharge nozzle, frame mounted, coupling and coupling guard included, prepared to assemble a 200kW, 2 pole motor, 50Hz, suction and discharge casing material made of cast iron, impellers and diffusers made of cast iron, mechanical seal Carbon/SiC, o-rings made of EPDM, mechanical seal.

Bareshaft pumpMPA100B/04A/BD/-25-CCC4 Seriese-MP,horizontalconfiguration,axialsuctioninlet,radialdischargenozzle,sizeDN100,hydraulicB,4stages/impellers,allimpellerswithfulldiameter,16barsuctionnozzle, 40 bar discharge nozzle, 2 pole motor, 50Hz, suction and discharge casing material made of cast iron, impellers and diffusers made of cast iron, mechanical seal Carbon/SiC, o-rings made of EPDM, mechanical seal.

Material diffuser [1 digit][C] = Cast iron[N]=Stainlesssteel[R] = Duplex [T] = Super duplex[X] = Others

Number of stages/impellers [2 digits], e.g.:[04] = 4 stages[18]=18stages

Pressure rate suction nozzle, standard [1 digit][A]=10bar,EN[B]=16bar,EN[C]=25bar,EN[D]=40bar,EN[E]=63bar,EN[R] = CL150, ASME[S]=CL300,ASME

Type of seal [1 digit] [ ] = Mechanical seal, standard[C] = Cartridge seal[P] = Soft packing

Pressure rate discharge nozzle, standard [1 digit][A]=10bar,EN[B]=16bar,EN[C]=25bar,EN[D]=40bar,EN[E]=63bar,EN[F]=100bar,EN[R] = CL150, ASME[S]=CL300,ASME[T]=CL600,ASME

Page 10: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

10

e-MP SERIESIDENTIFICATION CODE AND DESIGN OVERVIEwExample:MPA100B/04A/BD2000/w25VCCC4

Digits Description

MP Highly efficient and flexible multistage ring section pumpVarious design features for optimized efficiency values over the complete performance range offering configuration flexibility for a wide range of applications in different markets.

A Mechanical modelTotal 4 models to meeting different installation requirements3horizontalmodels:MPA,MPR,MPD 1 vertical model: MPVPumphousing: Suction casings are available with radial and axial arranged nozzles Discharge casings are available with radial arranged nozzelsRadialcasingnozzles(suctionanddischarge)canbeturnedin90°Csteps Sealing: by O-ringsBearings:Depending on mechanical model: Drive end: Roller bearing (grease or oil lubricated)Nondriveend:Rollerbearing(greaseoroillubricated) or plain bearing (lubricated by pumped liquid)Coupling and Coupling Guard: Horizontal models: Flexible coupling with and without spacer Vertical model: Close coupled with flexible coupling.

100 Mechanical size (nominal discharge nozzle diameter in mm)Total 5 mechanical sizes: DN50,DN65,DN100,DN125,DN150 to cover best efficiencies points (BEP) over the flow performance range.

B Hydraulic identifierTotal 10 hydraulics: 2 hydraulics (A,B) by mechanical size to increase the coverage of best efficiency points (BEP) over the flow performance range.

04A Number of stages and impeller trimming identificationUpto18stages(mechanicalsize50)4 standard impeller trimmings and optional trim of impellers exactly to the required duty point for an optimized efficiency.Impeller design: closed radial with curved vanes.

BD Nominal pressure identification for suction and discharge pumphousingHousingfornominalpressures,flangesareavailableforENand ASME standard: EN:10,16,25,40,63,100barASME:CL150,CL300,CL600.

2000 Motor power kW x 10

w2 Motor type and number of polesstandardIECandNEMAmotorswith2and4polesengineered to order drive options: diesel engine, turbine.

5V Frequency and power supply identification50Hzand60Hz3phasepowersupplyforvariousvoltages,uptohighvoltage.

CCC Material identification for pumphousing (suction, discharge and stage casing), impeller and diffuserPumphousing:castiron,ductileiron,steel,stainlesssteel(AISI316), duplex stainless steel, super duplex stainless steelImpeller:castiron,bronze,stainlesssteel(AISI316),duplexstainlesssteel, super duplex stainless steeldiffusor:castiron,stainlesssteel(AISI316),duplexstainlesssteel,superduplexstainlesssteel.

4( ) Material identification for mechanical seal and O-ring and type of sealElastomers: EPM, FKMShaftsealing:mechanicalseal(EN12756), cartridge seal (single, single quench, double) packing.

En-Rev_A

Page 11: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

11

1 13 12 10 9 2 7

19 3 4 6 5 15 1411

REGULATION (EU) No 547/2012

1 - Electric pump unit type 2 - Electric pump unit code3-Flowrange 4 - Head range5-Nominalormaximumpumppower6-Speed 7 - Serial number, orordernumber+orderpositionnumber 9 - Full impeller diameter (only filled in for trimmed impellers)10 - Trimmed impeller diameter (only filled in for trimmed impellers)11 - Minimum operating liquid temperature12 - Maximum operating liquid temperature13-Maximumoperatingpressure14 - Hydraulic efficiency in best efficiency point (50 Hz)15 - Minimum efficiency index MEI, as per Regulation (EU)No547/2012(50Hz)19 - Weight

LEGEND

PUMP ONLYELECTRIC PUMP

e-MP SERIESRATING PLATE

Noteforelectricpumpunit:refertomotordataplateforelectricaldata.

1 - Pump type 2 - Pump code 3-Flowrange 4 - Head range 5 - Maximum absorbed pump power6-Speed 7 - Serial number, or ordernumber+orderpositionnumber 9 - Full impeller diameter (only filled in for trimmed impellers)10 - Trimmed impeller diameter (only filled in for trimmed impellers)11 - Minimum operating liquid temperature12 - Maximum operating liquid temperature13-Maximumoperatingpressure14 - Hydraulic efficiency in best efficiency point (50 Hz)15 - Minimum efficiency index MEI, as per Regulation (EU)No547/2012(50Hz)19 - Weight

Q m3/h Pmax kW

1 13 9 12 11 10 2

4 6 5 15 14

REGULATION (EU) No 547/2012

3

No/Date

CodePN kPa t max °C t min °C kg

ØF mmH m

ØT mmn 1/min ØF MEI≥ ØT np%

7 19

LEGEND

Page 12: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

12

MPA SERIESELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS

Page 13: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

13

MPR SERIESELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS

Page 14: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

14

MPD SERIESELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS

Page 15: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

15

MPV SERIESELECTRIC PUMP CROSS-SECTION AND MAIN COMPONENTS

Page 16: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

16

e-MP SERIESTABLE OF MATERIAL REFERENCE STANDARDS

EUROPE USA*)

MP_materials-50-en_a_tc

MP_material-en_a_tc

e-MP SERIESTABLE OF MATERIAL CODE

Page 17: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

17

e-MP SERIESTABLE OF MATERIALS CAST IRON VERSION

MP-cast_iron-en_a_tm

Page 18: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

18

e-MP SERIESTABLE OF MATERIALS DUCTILE IRON VERSION

MP-ductile_iron-en_a_tm

Page 19: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

19

e-MP SERIESTABLE OF MATERIALS STAINLESS STEEL VERSION

MP-stainless_steel-en_a_tm

Page 20: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

20

e-MP SERIESMECHANICAL SEALS(MechanicalsealwithmountingdimensionsaccordingtoEN12756andISO3069WITHL1K)

MP_Mech_Seal-en_a_tm

MP_Mech_Seal-en_a_tc

MP_MS_dim-en_a_td

LIST OF MATERIALS

TYPE OF SEAL

TABLE OF DIMENSIONS

Page 21: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

21

e-MP SERIESMECHANICAL SEAL SELECTION DIAGRAM

MP_Limit_Mech_Seal-en_a_td

LIMIT CURVES DEPENDING ON PUMP HYDRAULICS AND MOTOR SPEED

MP_Mech_Seal-en_a_td

PIN....Pump inlet pressure at suction flange [bar]

GENERAL CONSIDERATIONSThis diagram and selection table is valid for clean water (solids < 10 mg/l) or water for feeding boilers, partially or totally demineralized.Ifthewatertemperatureexceeds80°C,minimuminletpressuremustbeguaranteed.

Page 22: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

22

e-MP SERIESPRESSURE / TEMPERATURE LIMITS FOR PUMP FLANGES ACCORDING TO EN 1092 AND CASING MATERIALPressure - temperature limits for pump flanges according EN1092 and casing material

0

10

20

30

40

50

-20 0 20 40 60 80 100 120 140 160

p [b

ar]

T [°C]

PN 25 - EN1092

PN 16 - EN1092

PN 10 - EN1092

PN 40 - EN1092

Material: Cast Iron - EN-GJL-250

0

10

20

30

40

50

60

70

-20 0 20 40 60 80 100 120 140 160 180 200

p [b

ar]

T [°C]

PN 63 - EN1092

Material: Ductile Iron - EN-GJS-400-15

PN 40 - EN1092

PN 16 - EN1092

PN 25 - EN1092

PN 10 - EN1092

0

10

20

30

40

50

60

70

-20 0 20 40 60 80 100 120 140 160 180 200

p [b

ar]

T [°C]

Material: Cast steel (1.0619)

PN 10 - EN1092

PN 16 - EN1092

PN 25 - EN1092

PN 40 - EN1092

PN 63 - EN1092

0

10

20

30

40

50

-20 0 20 40 60 80 100 120 140 160 180 200

p [b

ar]

T [°C]

PN 40 - EN1092

PN 25 - EN1092

PN 10 - EN1092

PN 16 - EN1092

Material: Austenitic Stainless steel (1.4408)

Page 23: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

23

e-MP SERIESPRESSURE / TEMPERATURE LIMITS FOR PUMP FLANGES ACCORDING TO ASME B16.5 AND CASING MATERIALPressure - temperature limits for pump flanges according ASME-B16.5 and casing material

0

10

20

30

40

50

60

70

-20 0 20 40 60 80 100 120 140 160 180 200

p [b

ar]

T [°C]

CLASS 150 - ASME B16.5

CLASS 300 - ASME B16.5

CLASS 600 - ASME B16.5

Material: Austenitic Stainless steel (1.4517) &

0

10

20

30

40

-20 0 20 40 60 80 100 120 140 160

p [b

ar]

T [°C]

Material: Cast Iron - EN-GJL-250

CLASS 300 - ASME B16.5

CLASS 150 - ASME B16.5

0

10

20

30

40

50

60

70

-20 0 20 40 60 80 100 120 140 160 180 200

p [b

ar]

T [°C]

Material: Ductile iron - EN-GJS-400-15

CLASS 150 - ASME B16.5

CLASS 300 - ASME B16.5

Flange drilled according CLASS 600

0

10

20

30

40

50

-20 0 20 40 60 80 100 120 140 160 180 200

p [b

ar]

T [°C]

Material: Austenitic Stainless steel (1.4408)

CLASS 150 - ASME B16.5

CLASS 300 - ASME B16.5

Super Duplex (1.4469)

Page 24: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

24

ErP 2009/125/EC

Withthe“EnergyusingProducts”(EuP2005/32/EC)and“EnergyrelatedProducts”(ErP2009/125/EC)directives,the European Commission has established requirements for promoting the use of products with low power consumption.

The various products considered include three-phase 50 Hz surface motors with power outputs ranging from 0,75 to 375 kw, also when integrated with other products, with characteristics as defined by the specific Regulations (EC) No 640/2009 and (EU) No 4/2014 implementing the requirements of the EuP and ErP Directives.

In accordance with regulations, the three-phase 50 Hz surface motors with power outputs ranging from 0,75 to 375 kw haveIE3asminimumlevelofefficiencyorIE2fittedwithvariablespeeddrive.IE2motorcanbesupplied without frequency converter as the obligation to have that device is related to when the motor is working and not when placed on the market.

• Short-circuit squirrel-cage motor, enclosed construction with external ventilation (TEFC).

•Ratedpowerfrom4to1200kWfor2-polerangeandfrom1,1to355kWfor4-polerange.

• IP55 protection degree.

• Insulation class 155 (F).

•Standard three-phasesurfacemotors≥0,75kWand<375kWsuppliedasIE3.

•IEefficiencylevelaccordingtoEN60034-30:2009andEN60034-30-1:2014(≥0,75kWand<355kW).

•ElectricalperformancesaccordingtoEN60034-1.

•MetriccableglandaccordingtoEN50262.

•Standard voltage Three-phase version:220-240/380-415V50Hzforpowerupto3kW.380-415/660-690V50Hzforpowerabove3kW. Overload protection to be provided by the user.

•PTC includedasstandardonlyforWEGmotors(oneperphase,155°C).

•Maximumambienttemperature:40°C.

e-MP SERIESMOTORS

Page 25: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

25

∆∆∆∆ ∆∆∆∆ ∆∆∆∆

ηηηη

ϕϕϕϕ

V

∆∆∆∆

0

e-MP SERIESTHREE-PHASE MOTORS AT 50 Hz, 2 POLES (from 5,5 to 18,5 kw)

Page 26: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

26

e-MP SERIESTHREE-PHASE MOTORS AT 50 Hz, 2 POLES (from 22 to 200 kw)

ηηηη

∆∆∆∆ ∆∆∆∆ ∆∆∆∆

ϕϕϕϕ

V

∆∆∆∆

Page 27: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

27

e-MP SERIESTHREE-PHASE MOTORS AT 50 Hz, 2 POLES (from 250 to 630 kw)

V

∆∆∆∆

ϕ (4/4)ϕ (4/4)ϕ (4/4)ϕ (4/4)

∆∆∆∆ ∆∆∆∆ ∆∆∆∆

ηηηη

Page 28: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

28

ηηηη

ϕ (4/4)ϕ (4/4)ϕ (4/4)ϕ (4/4)

V

∆∆∆∆

e-MP SERIESTHREE-PHASE MOTORS AT 50 Hz, 2 POLES (from 710 to 1250 kw)

Page 29: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

29

e-MP SERIESTHREE-PHASE MOTORS AT 50 Hz, 4 POLES (from 2,2 to 15 kw)

V

∆∆∆∆

ϕϕϕϕ

∆∆∆∆ ∆∆∆∆ ∆∆∆∆

ηηηη

Page 30: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

30

∆∆∆∆ ∆∆∆∆ ∆∆∆∆

ηηηη

ϕϕϕϕ

V

∆∆∆∆

e-MP SERIESTHREE-PHASE MOTORS AT 50 Hz, 4 POLES (from 18,5 to 250 kw)

Page 31: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

31

NOISE LEVEL

The tables below show the mean sound pressure levels (Lp) measured at 1 meter’s distance in a free field accordingtotheAcurve(ISO1680standard).Thenoisevaluesareindicatedwithatoleranceof3dB(A).

NOISE LEVEL OF PUMP wITH STANDARD MOTOR

NOISE LEVEL OF PUMP wITHOUT MOTOR

Page 32: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

32

e-MP SERIESPUMPSWith the “Energy using Products” (EuP 2005/32/EC) and“Energy related Products” (ErP 2009/125/EC) directives, the European Commission has established requirements for promoting the use of products with low power consumption.

The Commission Regulation (EU) No 547/2012 has implemented two directives with regard to ecodesign requirements for some types of clean water pumps placedonthemarketandputintoserviceinsideEUzoneasstand-alone units or integrated in other products.

For “multistage vertical water pumps” (MS-V for the Regulation) the efficiency assessment refers to:• just the pump andnot the pump andmotor assembly(electric or combustion);•pumpswithmorethanoneimpeller;•pumpswithimpellersmountedonaverticalshaft;•pumpswithanominalpressurePNnothigherthan25bar(2500 kPa);•pumpswithamaximumnominalflownotgreaterthan100m3/h(27,78*10-3m3/s);•pumpsdesignedtooperateataspeedof2900rpm(forelectric pumps this means 50 Hz 2-pole electric motors);• usewith cleanwater at a temperature ranging from-10°Cto120°C(thetestisperformedwithcoldwateratatemperaturenothigherthan40°C).

According to the definitions established in the Regulation MPV versions correspond to the “multistage vertical pump” while designs MPA, MPD and MPR as well as all MPV with nominal head higher than 25 bar do not fall under this regulation.This regulation states that water pumps shall have a minimum index MEI coming from a dedicated formula which considers hydraulic efficiency values at ‘best efficiency point’ (BEP), 75 % of the flow at BEP (Part load – PL) and 110 % of the flow at BEP (Over load – OL).

The Regulation also establishes the following deadlines.

Regulation (EU) n. 547/2012 – Annex II – point 2(Product information requirements)1. Minimum efficiency index: see MEI values in specific

table below.2. “The benchmark for most efficient water pumps is MEI

≥0,70”.3. Year of manufacture: 2017.4. Manufacturer: Xylem Service Italia Srl - Reg. No

07520560967-MontecchioMaggiore,Vicenza,Italy.

5. Producttype:seethePUMPTYPEcolumninthetablesin the Hydraulic performance section.

6. Hydraulic pump efficiency with trimmed impeller: see hp and ØT columns in the tables in the Hydraulic performance section.

7. Pump performance curves, including the performance curve: see the Operating Characteristics graphs in the following pages.

8. “The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter of a single stage”.

9. “The operation of this water pump with variable duty points may be more efficient and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system”.

10. Information relevant for disassembly, recycling or disposal at end-of-life: observe the current laws and by-laws governing sorted waste disposal. Consult the product operating manual.

11. “Designed for use below – 10 °C only”: note notapplicable to these products.

12. “Designedforuseabove120°Conly”:notenotapplicableto these products.

13. Specific instructions for pumps as per points 11 and 12: not applicable to these products.

14. “Information on benchmark efficiency is available at”: www.europump.org (Ecodesign section).

15. The benchmark efficiency graphs with MEI = 0.7 and MEI = 0.4 are available at www.europump.org, Ecodesign, Efficiency charts (refer to “MS-V”).

ErP 2009/125/EC

from minimum efficiency index (MEI)1st January 2015 MEI ≥ 0,4

PUMPSIZE Minimum efficiency index (MEI)MPV50A ≥ 0,7MPV50B ≥ 0,7MPV65A ≥ 0,7MPV65B ≥ 0,7

MINIMUM EFFICIENCY INDEX (MEI)

Page 33: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

33

e-MP SERIESHYDRAULIC PERFORMANCE RANGE AT 50 Hz, 2 POLES

Q [US gpm]20 30 40 50 60 70 80 200 300 400 500 600 700 800 2000 3000 4000100 1000

H [

ft]

500

750

1000

1500

1750

2000

2250

2750

3000

3250

1250

2500

Q [l/s]2 3 4 5 6 8 20 30 40 50 60 80 20010 100

H [

m]

100

200

300

400

500

600

700

800

900

1000

Q [Imp gpm]20 30 40 50 60 70 80 200 300 400 500 600 700 800 2000 3000100 1000

Q [m3/h]4 5 6 7 8 9 20 30 40 50 60 70 80 90 200 300 400 500 600 700 800 90010 100 1000

e-MP ~ 2950 [rpm] ISO 9906:2012

A000

3_

A_

CH

150B150A125B125A100B100A65B65A50B50A

150A125B125A100B100A65B65A

HYDRAULIC PERFORMANCE RANGE AT 50 Hz, 4 POLES

Q [US gpm]20 30 40 50 60 70 80 200 300 400 500 600 700 800 200010 100 1000

H [

ft]

0,2

0,3

0,40,50,6

0,8

2

3

456

8

20

30

405060

80

200

300

400500600

800

0,1

1

10

100

Q [l/s]0,6 0,8 2 3 4 5 6 8 20 30 40 50 60 801 10 100

H [

m]

0

100

200

300

Q [Imp gpm]8 20 30 40 50 60 70 80 200 300 400 500 600 700 800 200010 100 1000

Q [m3/h]2 3 4 5 6 7 8 9 20 30 40 50 60 70 80 90 200 300 400 500 60010 100

e-MP ~ 1450 [rpm] ISO 9906:2012

A000

4_

A_

CH

150B150A125B125A100B100A65B65A50B50A

Page 34: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

34

e-MP50A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP50A/01 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

1A

1B

68,5

66,8

63,3

67

67

65

65

60 55 50

50

1C

0 50 100 150 200 250

16

36

56

76

96

116

136

5

10

15

20

25

30

35

40

45Q [US gpm]

H [ft

]

H[m

]

h[%]

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

0

1

2

3

4

5

6

0

1

2

3

4

5

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-01_

50Hz

_2_A

Ø169

Ø157

Ø145

e-MPR, e-MPD, e-MPV e-MPA

e-MP50A/02 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

2A

2B

2C

0 50 100 150 200 250

33

83

133

183

233

10

20

30

40

50

60

70

80Q [US gpm]

H [ft

]

H[m

]

2A

2B

2C

0

2

4

6

8

10

12

0

2

4

6

8

10

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-02_

50Hz

_2_A

2xØ157

2xØ242

2xØ145

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

68,5

66,8

63,3

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP50A/03 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

3A

3B 3C

0 50 100 150 200 250

66

116

166

216

266

316

366

20

30

40

50

60

70

80

90

100

110

120Q [US gpm]

H [ft

] H[m

]

3A

3B

3C

3

8

13

18

2

4

6

8

10

12

14

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-03_

50Hz

_2_A

1xØ169/2xØ157

3xØ169

1xØ169/2xØ145

3C

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

68,5

67,4

65,0

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP50A/04 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

4A 4B 4C

0 50 100 150 200 250

66

116

166

216

266

316

366

416

466

516

20

40

60

80

100

120

140

160Q [US gpm]

H [ft

] H[m

]

4A 4B

4C

0

5

10

15

20

25

0

5

10

15

20

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-04_

50Hz

_2_A

2xØ169/2xØ157

4xØ169

4xØ157

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

68,5

67,7

66,8

h[%]

e-MPR, e-MPD, e-MPV e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 35: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

35

e-MP50A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP50A/05 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

5A 5B 5C

0 50 100 150 200 250

131

231

331

431

531

631

40

60

80

100

120

140

160

180

200Q [US gpm]

H [ft

]

H[m

]

5A 5B

5C

7

12

17

22

27

32

5

10

15

20

25

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-05_

50Hz

_2_A

3xØ169/2xØ157

5xØ169

1xØ169/4xØ157

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

e-MPR, e-MPD, e-MPV e-MPA

68,5 67,9

67,1

h[%]

e-MP50A/06 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

6A 6B 6C

0 50 100 150 200 250

164

264

364

464

564

664

764

50

70

90

110

130

150

170

190

210

230

250Q [US gpm]

H [ft

] H[m

]

6A 6B

6C

7

12

17

22

27

32

37

5

10

15

20

25

30

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-06_

50Hz

_2_A

4xØ169/2xØ157 6xØ169

2xØ169/4xØ157

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

e-MPR, e-MPD, e-MPV e-MPA

68,5

68,0

67,4

h[%]

e-MP50A/07 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

7A 7B 7C

0 50 100 150 200 250

328

428

528

628

728

828

100

120

140

160

180

200

220

240

260

280Q [US gpm]

H [ft

]

H[m

]

7A 7B

7C

7

17

27

37

47

5

10

15

20

25

30

35

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-07_

50Hz

_2_B

5xØ169/2xØ157 7xØ169

3xØ169/4xØ157

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

68,5

68,1

67,6

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP50A/08 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

8A 8B

8C

0 50 100 150 200 250

410

510

610

710

810

910

1010

125

145

165

185

205

225

245

265

285

305

325Q [US gpm]

H [ft

]

H[m

]

8A 8B

8C

7

17

27

37

47

5

10

15

20

25

30

35

40

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-08_

50Hz

_2_A

6xØ169/2xØ157 8xØ169

4xØ169/4xØ157

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

68,5

68,1

67,7

h[%]

e-MPR, e-MPD, e-MPV e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 36: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

36

e-MP50A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP50A/09 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

9A 9B

9C

0 50 100 150 200 250

492

592

692

792

892

992

1092

150

170

190

210

230

250

270

290

310

330

350Q [US gpm]

H [ft

] H[m

]

9A 9B

9C

13

23

33

43

53

10

15

20

25

30

35

40

45

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-9_5

0Hz_

2_A

7xØ169/2xØ157 9xØ169

5xØ169/4xØ157

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

e-MPR, e-MPD, e-MPV e-MPA

68,5

68,2

67,8

h[%]

e-MP50A/10 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

10A 10B

10C

0 50 100 150 200 250

492

592

692

792

892

992

1092

1192

1292

150

200

250

300

350

400Q [US gpm]

H [ft

]

H[m

]

10A 10B

10C

13

23

33

43

53

63

101520253035404550

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-10_

50Hz

_2_A

8xØ169/2xØ157 10xØ169

6xØ169/4xØ157

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

e-MPR, e-MPD, e-MPV e-MPA

68,5

68,2

67,9

h[%]

e-MP50A/11-15 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

15A 14A 13A 12A 11A

0 50 100 150 200 250

492

692

892

1092

1292

1492

1692

1892

150

200

250

300

350

400

450

500

550

600Q [US gpm]

H [ft

]

H[m

]

15A 14A 13A 12A 11A

13

33

53

73

93

10

20

30

40

50

60

70

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-11-

15_5

0Hz_

2_A

14xØ169

15xØ169

13xØ169

12xØ169

11xØ169

0

2

4

6

NPS

Hr[m

]

e-MPR, e-MPD, e-MPV e-MPA

68,5

68,5

68,5

68,5

68,5

h[%]

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 37: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

37

e-MP50B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP50B/01 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

1A

1B

74,6

72,1

68,7

72

72

70

70

65

65

60

60

1C

0 50 100 150 200 250 300 350

16

36

56

76

96

116

136

5

10

15

20

25

30

35

40

45Q [US gpm]

H [ft

]

H[m

]

h[%]

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-01_

50Hz

_2_A

Ø173

Ø161

Ø149

e-MPR, e-MPD, e-MPV e-MPA

e-MP50B/02 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

2A

2B

2C

0 50 100 150 200 250 300 350

66

116

166

216

266

20

30

40

50

60

70

80

90Q [US gpm]

H [ft

]

H[m

]

2A

2B

2C

3

8

13

18

2

4

6

8

10

12

14

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-02_

50Hz

_2_A

2xØ161

2xØ242

2xØ149

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

74,6

72,1

68,7

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP50B/03 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

3A

3B 3C

0 50 100 150 200 250 300 350

98

148

198

248

298

348

398

30

40

50

60

70

80

90

100

110

120

130Q [US gpm]

H [ft

] H[m

]

3A

3B

3C

7

12

17

22

27

5

10

15

20

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-03_

50Hz

_2_A

1xØ173/2xØ161

3xØ173

1xØ173/2xØ149

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

74,6

72,9

70,6

h[%]

e-MPR, e-MPD, e-e-MPA

e-MP50B/04 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

4A 4B 4C

0 50 100 150 200 250 300 350

66

166

266

366

466

566

20

40

60

80

100

120

140

160

180Q [US gpm]

H [ft

]

H[m

]

4A 4B

4C

7

12

17

22

27

32

5

10

15

20

25

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-04_

50Hz

_2_A

2xØ173/2xØ161

4xØ173

4xØ161

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

74,6

73,4

72,1

h[%]

e-MPR, e-MPD, e-e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 38: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

38

e-MP50B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP50B/05 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

5A 5B 5C

0 50 100 150 200 250 300 350

131

231

331

431

531

631

40

60

80

100

120

140

160

180

200

220Q [US gpm]

H [ft

]

H[m

]

5A 5B

5C

13

18

23

28

33

38

43

10

15

20

25

30

35

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-05_

50Hz

_2_A

3xØ173/2xØ161

5xØ173

1xØ173/4xØ161

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

74,6

73,6

72,6

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP50B/06 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

6A 6B 6C

0 50 100 150 200 250 300 350

312

412

512

612

712

812

95

115

135

155

175

195

215

235

255Q [US gpm]

H [ft

]

H[m

]

6A 6B

6C

13

23

33

43

53

10

15

20

25

30

35

40

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-06_

50Hz

_2_A

4xØ173/2xØ161

6xØ173

2xØ173/4xØ161

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

74,6

73,8

73,0

h[%]

e-MPR, e-MPD, e-e-MPA

e-MP50B/07 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

7A 7B

7C

0 50 100 150 200 250 300 350

328

428

528

628

728

828

928

100

120

140

160

180

200

220

240

260

280

300Q [US gpm]

H [ft

]

H[m

]

7A 7B

7C

20

30

40

50

60

15

20

25

30

35

40

45

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-07_

50Hz

_2_A

5xØ173/2xØ161

7xØ173

3xØ173/4xØ161

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

74,6

73,9

73,2

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP50B/08 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

8A 8B

8C

0 50 100 150 200 250 300 350

410

510

610

710

810

910

1010

1110

1210

125

175

225

275

325

375Q [US gpm]

H [ft

]

H[m

]

8A 8B

8C

20

30

40

50

60

15

20

25

30

35

40

45

50

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-08_

50Hz

_2_A

6xØ173/2xØ161

8xØ173

4xØ173/4xØ161

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

74,6

74,0

73,4

h[%]

e-MPR, e-MPD, e-e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 39: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

39

e-MP50B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP50B/09 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

9A 9B

9C

0 50 100 150 200 250 300 350

492

592

692

792

892

992

1092

1192

1292

150

200

250

300

350

400Q [US gpm]

H [ft

]

H[m

]

9A 9B 9C

27

37

47

57

67

77

20

30

40

50

60

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-9_5

0Hz_

2_A

7xØ173/2xØ161 9xØ173

5xØ173/4xØ161

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

74,6

74,1

73,5

h[%]

e-MPR, e-MPD, e-e-MPA

e-MP50B/10 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

10A 10B

10C

0 50 100 150 200 250 300 350

492

592

692

792

892

992

1092

1192

1292

1392

150

200

250

300

350

400

450Q [US gpm]

H [ft

]

H[m

]

10A 10B

10C

27

37

47

57

67

77

87

20

30

40

50

60

70

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-10_

50Hz

_2_A

8xØ173/2xØ161 10xØ173

6xØ173/4xØ161

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

74,6

74,1

73,6

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP50B/11-15 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

15A 14A 13A 12A 11A

0 50 100 150 200 250 300 350

492

692

892

1092

1292

1492

1692

1892

2092

150

200

250

300

350

400

450

500

550

600

650Q [US gpm]

H [ft

]

H[m

]

15A 14A 13A 12A 11A

27

47

67

87

107

127

20

40

60

80

100

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-11-

15_5

0Hz_

2_A

14xØ173

15xØ173

13xØ173

12xØ173

11xØ173

0

2

4

6

8

NPS

Hr[m

]

74,6

74,6

74,6

74,6

74,6

h[%]

e-MPR, e-MPD, e-e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 40: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

40

e-MP65A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP65A/01 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35

Q [Imp gpm]

Q [l/s]

1A 1B

76,4

73,9

69,7

74

74

70

70

65

65

60

60

55 50

1C

0 100 200 300 400 500 600

16

36

56

76

96

116

136

156

176

196

5

15

25

35

45

55

65Q [US gpm]

H [ft

]

H[m

]

h[%]

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

4

6

8

10

12

14

16

3456789

10111213

0 20 40 60 80 100 120 140

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65A

-01_

50Hz

_2_A

Ø206

Ø190

Ø174

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65A/02 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35

Q [Imp gpm]

Q [l/s]

2A 2B

2C

0 100 200 300 400 500 600

66

116

166

216

266

316

366

20

30

40

50

60

70

80

90

100

110

120Q [US gpm]

H [ft

]

H[m

]

2A

2B

2C

7

12

17

22

27

32

5

10

15

20

25

0 20 40 60 80 100 120 140

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65A

-02_

50Hz

_2_A

1xØ242/1xØ174

2xØ242

2xØ174

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,4

73,3

69,7

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65A/03 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35

Q [Imp gpm]

Q [l/s]

3A 3B 3C

0 100 200 300 400 500 600

131

181

231

281

331

381

431

481

531

581

40

60

80

100

120

140

160

180Q [US gpm]

H [ft

]

H[m

]

3A 3B

3C

13

23

33

43

53

10

15

20

25

30

35

40

0 20 40 60 80 100 120 140

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65A

-03_

50Hz

_2_A

2xØ206/1xØ174

3xØ206

1xØ206/2xØ174

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,4

74,4

72,2

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65A/04 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35

Q [Imp gpm]

Q [l/s]

4A 4B 4C

0 100 200 300 400 500 600

197

297

397

497

597

697

60

80

100

120

140

160

180

200

220

240Q [US gpm]

H [ft

] H[m

]

4A 4B

4C

13

23

33

43

53

63

101520253035404550

0 20 40 60 80 100 120 140

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65A

-04_

50Hz

_2_A

3xØ206/1xØ174

4xØ206

2xØ206/2xØ174

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,4

74,9

73,3

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 41: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

41

e-MP65A/05 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35

Q [Imp gpm]

Q [l/s]

5A 5B

5C

0 100 200 300 400 500 600

164

264

364

464

564

664

764

864

964

50

100

150

200

250

300Q [US gpm]

H [ft

]

H[m

]

5A 5B

5C

20

30

40

50

60

70

80

15

25

35

45

55

65

0 20 40 60 80 100 120 140

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65A

-05_

50Hz

_2_A

4xØ206/1xØ174

5xØ206

3xØ206/2xØ174

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,4

75,2

74,0

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP50B/06 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20

Q [Imp gpm]

Q [l/s]

6A 6B 6C

0 50 100 150 200 250 300 350

312

412

512

612

712

812

95

115

135

155

175

195

215

235

255Q [US gpm]

H [ft

]

H[m

]

6A 6B

6C

13

23

33

43

53

10

15

20

25

30

35

40

0 10 20 30 40 50 60 70 80

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-06_

50Hz

_2_A

4xØ173/2xØ161

6xØ173

2xØ173/4xØ161

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

74,6

73,8

73,0

h[%]

e-MPR, e-MPD, e-e-MPA

e-MP50A/07 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

7A 7B 7C

0 50 100 150 200 250

328

428

528

628

728

828

100

120

140

160

180

200

220

240

260

280Q [US gpm]

H [ft

]

H[m

]

7A 7B

7C

7

17

27

37

47

5

10

15

20

25

30

35

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-07_

50Hz

_2_B

5xØ169/2xØ157 7xØ169

3xØ169/4xØ157

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

68,5

68,1

67,6

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP50A/08 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200

0 2 4 6 8 10 12 14 16

Q [Imp gpm]

Q [l/s]

8A 8B

8C

0 50 100 150 200 250

410

510

610

710

810

910

1010

125

145

165

185

205

225

245

265

285

305

325Q [US gpm]

H [ft

]

H[m

]

8A 8B

8C

7

17

27

37

47

5

10

15

20

25

30

35

40

0 10 20 30 40 50 60

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-08_

50Hz

_2_A

6xØ169/2xØ157 8xØ169

4xØ169/4xØ157

0

5

10

15

0

2

4

6

NPS

Hr[ft

]

NPS

Hr[m

]

68,5

68,1

67,7

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP65A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 42: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

42

e-MP65A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP65A/09 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35

Q [Imp gpm]

Q [l/s]

9A 9B

9C

0 100 200 300 400 500 600

492

692

892

1092

1292

1492

1692

150

200

250

300

350

400

450

500

550Q [US gpm]

H [ft

]

H[m

]

9A 9B 9C

34

54

74

94

114

134

154

25

45

65

85

105

125

0 20 40 60 80 100 120 140

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65A

-9_5

0Hz_

2_A

8xØ206/1xØ174 9xØ206

7xØ206/2xØ174

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,4

75,7

75,1

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65A/10 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35

Q [Imp gpm]

Q [l/s]

10A 10B 10C

0 100 200 300 400 500 600

656

856

1056

1256

1456

1656

1856

200

250

300

350

400

450

500

550

600Q [US gpm]

H [ft

]

H[m

]

10A 10B

10C

40

60

80

100

120

140

160

30

50

70

90

110

130

0 20 40 60 80 100 120 140

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65A

-10_

50Hz

_2_A

9xØ206/1xØ174 10xØ206

8xØ206/2xØ174

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,4

75,8

75,2

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 43: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

43

e-MP65B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP65B/01 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

1A

1B

80,0

77,6

74,7

77

77

75

75

70

70

65 60 55

1C

0 100 200 300 400 500 600 700

49

69

89

109

129

149

169

189

209

15

20

25

30

35

40

45

50

55

60

65Q [US gpm]

H [ft

]

H[m

]

h[%]

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

7

12

17

22

5

7

9

11

13

15

17

19

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65B

-01_

50Hz

_2_A

Ø214

Ø200

Ø186

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B/02 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

2A

2B

2C

0 100 200 300 400 500 600 700

98

148

198

248

298

348

398

30

40

50

60

70

80

90

100

110

120

130Q [US gpm]

H [ft

]

H[m

]

2A

2B

2C

13

23

33

43

53

10

15

20

25

30

35

40

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65B

-02_

50Hz

_2_A

1xØ214/1xØ186

2xØ214

2xØ186

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

80,0

77,5

74,7

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B/03 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

3A 3B

3C

0 100 200 300 400 500 600 700

131

231

331

431

531

631

40

60

80

100

120

140

160

180

200Q [US gpm]

H [ft

]

H[m

]

3A 3B

3C

20

30

40

50

60

70

152025303540455055

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65B

-03_

50Hz

_2_A

2xØ214/1xØ186

3xØ214

1xØ214/2xØ186

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

80,0

78,4

76,6

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B/04 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

4A 4B

4C

0 100 200 300 400 500 600 700

197

297

397

497

597

697

797

60

80

100

120

140

160

180

200

220

240

260Q [US gpm]

H [ft

]

H[m

]

4A 4B

4C

27

47

67

87

107

20

30

40

50

60

70

80

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65B

-04_

50Hz

_2_A

3xØ214/1xØ186

4xØ214

2xØ214/2xØ186

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

80,0

78,8

77,5

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 44: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

44

e-MP65B/05 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

5A 5B 5C

0 100 200 300 400 500 600 700

246

346

446

546

646

746

846

946

1046

75

125

175

225

275

325Q [US gpm]

H [ft

]

H[m

]

5A

5B 5C

34

54

74

94

114

25

35

45

55

65

75

85

95

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65B

-05_

50Hz

_2_A

4xØ214/1xØ186

5xØ214

3xØ214/2xØ186

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

80,0

79,0

78,0

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B/06 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

6A 6B 6C

0 100 200 300 400 500 600 700

328

428

528

628

728

828

928

1028

1128

1228

100

150

200

250

300

350

400Q [US gpm]

H [ft

] H[m

]

6A 6B

6C

40

60

80

100

120

140

30405060708090

100110

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65B

-06_

50Hz

_2_A

5xØ214/1xØ186

6xØ214

4xØ214/2xØ186

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

80,0

79,2

78,3

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B/07 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

7A 7B

7C

0 100 200 300 400 500 600 700

328

528

728

928

1128

1328

100

150

200

250

300

350

400

450Q [US gpm]

H [ft

]

H[m

]

7A 7B

7C

40

60

80

100

120

140

160

30

50

70

90

110

130

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65B

-07_

50Hz

_2_A

6xØ214/1xØ186

7xØ214

5xØ214/2xØ186

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

80,0

79,3

78,6

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B/08 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

8A 8B

8C

0 100 200 300 400 500 600 700

492

692

892

1092

1292

1492

1692

150

200

250

300

350

400

450

500

550Q [US gpm]

H [ft

]

H[m

]

8A 8B

8C

34

84

134

184

25

45

65

85

105

125

145

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65B

-08_

50Hz

_2_A

7xØ214/1xØ186 8xØ214

6xØ214/2xØ186

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

80,0 79,4

78,8

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 45: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

45

e-MP65B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP65B/09 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

9A 9B

9C

0 100 200 300 400 500 600 700

328

528

728

928

1128

1328

1528

1728

1928

100

150

200

250

300

350

400

450

500

550

Q [US gpm]

H [ft

]

H[m

]

9A 9B 9C

54

104

154

204

40

60

80

100

120

140

160

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65B

-9_5

0Hz_

2_A

8xØ214/1xØ186 9xØ214

7xØ214/2xØ186

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

80,0 79,5

78,9

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B/10 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

10A 10B 10C

0 100 200 300 400 500 600 700

820

1020

1220

1420

1620

1820

2020

250

300

350

400

450

500

550

600

650Q [US gpm]

H [ft

] H[m

]

10A 10B

10C

67

117

167

217

50

70

90

110

130

150

170

190

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65B

-10_

50Hz

_2_A

9xØ214/1xØ186

10xØ214

8xØ214/2xØ186

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

80,0

79,5

79,0

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 46: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

46

e-MP100A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP100A/01 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500 600 700 800 900

0 10 20 30 40 50 60

Q [Imp gpm]

Q [l/s]

1A

1B 1C

76,1

73,8

70,0

64,3

73

73

70

70

65

65

60 50

1D

0 200 400 600 800 1000

0

50

100

150

200

250

300

0

10

20

30

40

50

60

70

80

90

100Q [US gpm]

H [ft

]

H[m

]

h[%]

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

1D

0

10

20

30

40

50

0

10

20

30

40

0 50 100 150 200 250

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

A-01

_50H

z_2_

A

Ø242

Ø224

Ø206

Ø188

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100A/02 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500 600 700 800 900

0 10 20 30 40 50 60

Q [Imp gpm]

Q [l/s]

2A 2B

2C 2D

2E

0 200 400 600 800 1000

66

166

266

366

466

566

20

40

60

80

100

120

140

160

180Q [US gpm]

H [ft

]

H[m

]

2A 2B

2C 2D

2E

0

20

40

60

80

100

0

20

40

60

80

0 50 100 150 200 250

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

A-02

_50H

z_2_

A

1xØ242/1xØ224

2xØ242

2xØ224

1xØ224/1xØ206

2xØ206

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,1

75,0

73,7

71,9

69,9

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100A/03 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500 600 700 800 900

0 10 20 30 40 50 60

Q [Imp gpm]

Q [l/s]

3A 3B

3C 3D

0 200 400 600 800 1000

164

264

364

464

564

664

764

864

50

100

150

200

250

Q [US gpm]

H [ft

]

H[m

]

3A 3B

3C

3D

27

47

67

87

107

127

147

20

40

60

80

100

120

0 50 100 150 200 250

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

A-03

_50H

z_2_

A

2xØ242/1xØ224

3xØ242

1xØ242/2xØ224

1xØ242/2xØ206

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,1

75,4

74,6

72,2

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100A/04 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500 600 700 800 900

0 10 20 30 40 50 60

Q [Imp gpm]

Q [l/s]

4A 4B

4C

0 200 400 600 800 1000

328

428

528

628

728

828

928

1028

1128

100

150

200

250

300

350Q [US gpm]

H [ft

]

H[m

]

4A

4B

4C

54

74

94

114

134

154

174

40

60

80

100

120

140

0 50 100 150 200 250

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

A-04

_50H

z_2_

A

2xØ242/2xØ224

4xØ242

4xØ224

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,1

75,0

73,7

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 47: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

47

e-MP100A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP100A/05 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500 600 700 800 900

0 10 20 30 40 50 60

Q [Imp gpm]

Q [l/s]

5A

5B

5C

0 200 400 600 800 1000

328

528

728

928

1128

1328

100

150

200

250

300

350

400

450Q [US gpm]

H [ft

]

H[m

]

5A 5B

5C

67

117

167

217

267

50

75

100

125

150

175

200

0 50 100 150 200 250

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

A-05

_50H

z_2_

A

3xØ242/2xØ224

5xØ242

1xØ242/4xØ224

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,1

75,2

74,3

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100A/06 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500 600 700 800 900

0 10 20 30 40 50 60

Q [Imp gpm]

Q [l/s]

6A

6B 6C

0 200 400 600 800 1000

492

692

892

1092

1292

1492

1692

150

200

250

300

350

400

450

500

550Q [US gpm]

H [ft

]

H[m

]

6A 6B

6C

80

130

180

230

280

6080

100120140160180200220

0 50 100 150 200 250

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

A-06

_50H

z_2_

A

4xØ242/2xØ224

6xØ242

2xØ242/4xØ224

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,1

75,4

74,6

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100A/07 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500 600 700 800 900

0 10 20 30 40 50 60

Q [Imp gpm]

Q [l/s]

7A 7B

7C

0 200 400 600 800 1000

492

692

892

1092

1292

1492

1692

1892

2092

150

200

250

300

350

400

450

500

550

600

650Q [US gpm]

H [ft

]

H[m

]

7A 7B

7C

67

117

167

217

267

317

50

100

150

200

250

0 50 100 150 200 250

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

A-07

_50H

z_2_

A

5xØ242/2xØ224

7xØ242

3xØ242/4xØ224

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

76,1

75,5

74,8

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 48: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

48

e-MP100B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP100B/01 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200

0 10 20 30 40 50 60 70 80 90

Q [Imp gpm]

Q [l/s]

1A 1B 1C

80,7

77,3

71,7

64,9

77

77

75

75

70

70

65

65

60

60

1D

0 200 400 600 800 1000 1200 1400

0

50

100

150

200

250

0

10

20

30

40

50

60

70

80

90Q [US gpm]

H [ft

]

H[m

]

h[%]

0

10

20

30

0

2

4

6

8

10

12

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

1D

13

23

33

43

53

63

10

15

20

25

30

35

40

45

50

0 50 100 150 200 250 300 350

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

B-01

_50H

z_2_

A

Ø245

Ø226

Ø207

Ø188

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100B/02 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200

0 10 20 30 40 50 60 70 80 90

Q [Imp gpm]

Q [l/s]

2A 2B

2C 2D

2E

0 200 400 600 800 1000 1200 1400

66

166

266

366

466

566

20

40

60

80

100

120

140

160

180Q [US gpm]

H [ft

]

H[m

]

2A 2B

2C 2D

2E

27

47

67

87

107

127

2030405060708090

100

0 50 100 150 200 250 300 350

P [H

P]

P [k

W]

Q [m3/h

e-M

P100

B-02

_50H

z_2_

A

1xØ242/1xØ226

2xØ242

2xØ226

1xØ226/1xØ207

2xØ207

0

10

20

30

0

2

4

6

8

10

12

NPS

Hr[ft

]

NPS

Hr[m

]

80,7

78,9

77,3

74,6

71,7

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100B/03 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200

0 10 20 30 40 50 60 70 80 90

Q [Imp gpm]

Q [l/s]

3A 3B

3C

0 200 400 600 800 1000 1200 1400

82

182

282

382

482

582

682

782

882

25

75

125

175

225

275Q [US gpm]

H [ft

] H[m

]

3A

3B

3C

54

74

94

114

134

154

174

40

60

80

100

120

140

0 50 100 150 200 250 300 350

P [H

P]

P [k

W]

Q [m3/h

e-M

P100

B-03

_50H

z_2_

A

1xØ245/2xØ226

3xØ245

1xØ245/2xØ207

0

10

20

30

0

2

4

6

8

10

12

NPS

Hr[ft

]

NPS

Hr[m

]

80,7

78,4

74,7

h[%]

80,7

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100B/04 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200

0 10 20 30 40 50 60 70 80 90

Q [Imp gpm]

Q [l/s]

4A 4B

4C

0 200 400 600 800 1000 1200 1400

164

364

564

764

964

1164

50

100

150

200

250

300

350

400Q [US gpm]

H [ft

] H[m

]

4A

4B 4C

67

117

167

217

267

50

75

100

125

150

175

200

0 50 100 150 200 250 300 350

P [H

P]

P [k

W]

Q [m3/h

e-M

P100

B-04

_50H

z_2_

A

2xØ245/2xØ226

4xØ245

4xØ226

0

10

20

30

0

5

10

NPS

Hr[ft

]

NPS

Hr[m

]

80,7

78,9

77,3

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 49: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

49

e-MP100B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

e-MP100B/05 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200

0 10 20 30 40 50 60 70 80 90

Q [Imp gpm]

Q [l/s]

5A 5B 5C

0 200 400 600 800 1000 1200 1400

246

446

646

846

1046

1246

1446

75

125

175

225

275

325

375

425

475Q [US gpm]

H [ft

]

H[m

]

5A 5B

5C

67

117

167

217

267

317

50

100

150

200

250

0 50 100 150 200 250 300 350

P [H

P]

P [k

W]

Q [m3/h

e-M

P100

B-05

_50H

z_2_

A

3xØ245/2xØ226

5xØ245

1xØ245/4xØ226

0

10

20

30

0

2

4

6

8

10

12

NPS

Hr[ft

]

NPS

Hr[m

]

80,7

79,2

77,9

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100B/06 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200

0 10 20 30 40 50 60 70 80 90

Q [Imp gpm]

Q [l/s]

6A 6B

6C

0 200 400 600 800 1000 1200 1400

328

528

728

928

1128

1328

1528

1728

100

150

200

250

300

350

400

450

500

550Q [US gpm]

H [ft

]

H[m

]

6A 6B

6C

134

184

234

284

334

384

100

150

200

250

300

0 50 100 150 200 250 300 350

P [H

P]

P [k

W]

Q [m3/h

e-M

P100

B-06

_50H

z_2_

A

4xØ245/2xØ226

6xØ245

2xØ245/4xØ226

0

10

20

30

0

2

4

6

8

10

12

NPS

Hr[ft

]

NPS

Hr[m

]

80,7 79,5

78,4

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100B/07 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200

0 10 20 30 40 50 60 70 80 90

Q [Imp gpm]

Q [l/s]

7A 7B

7C

0 200 400 600 800 1000 1200 1400

328

528

728

928

1128

1328

1528

1728

1928

2128

100

200

300

400

500

600

700Q [US gpm]

H [ft

]

H[m

]

7A 7B

7C

134

184

234

284

334

384

434

100

150

200

250

300

350

0 50 100 150 200 250 300 350

P [H

P]

P [k

W]

Q [m3/h

e-M

P100

B-07

_50H

z_2_

A

5xØ245/2xØ226

7xØ245

3xØ245/4xØ226

0

10

20

30

0

2

4

6

8

10

12

NPS

Hr[ft

]

NPS

Hr[m

]

80,7

79,7

78,7

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 50: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

50

e-MP125A/01 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200 1400 1600

0 20 40 60 80 100 120

Q [Imp gpm]

Q [l/s]

1A

1B 1C

80,0

79,5

78,4

76,0

78

78

76

76

70

70

65 60 50

1D

0 200 400 600 800 1000 1200 1400 1600 1800

98

148

198

248

298

348

30

40

50

60

70

80

90

100

110

120Q [US gpm]

H [ft

]

H[m

]

h[%]

0

10

20

30

40

0

5

10

15

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B 1C

1D

34

54

74

94

114

25

35

45

55

65

75

85

95

0 50 100 150 200 250 300 350 400 450

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

A-01

_50H

z_2_

A

Ø283

Ø268

Ø258

Ø243

e-MPR, e-MPD, e-MPV e-MPA

e-MP125A/02 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200 1400 1600

0 20 40 60 80 100 120

Q [Imp gpm]

Q [l/s]

2A

2B

2C 2D

0 200 400 600 800 1000 1200 1400 1600 1800

230

330

430

530

630

730

70

90

110

130

150

170

190

210

230Q [US gpm]

H [ft

]

H[m

]

2A

2B

2C

2D

67

117

167

217

50

70

90

110

130

150

170

190

0 50 100 150 200 250 300 350 400 450

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

A-02

_50H

z_2_

A

1xØ283/1xØ258

2xØ283

2xØ258

2xØ243

0

10

20

30

40

0

5

10

15

NPS

Hr[ft

]

NPS

Hr[m

]

80,0

79,1

78,4

76,0

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP125A/03 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200 1400 1600

0 20 40 60 80 100 120

Q [Imp gpm]

Q [l/s]

3A 3B 3C 3D

0 200 400 600 800 1000 1200 1400 1600 1800

328

428

528

628

728

828

928

1028

1128

100

150

200

250

300

350Q [US gpm]

H [ft

]

H[m

]

3A 3B

3C 3D

107

157

207

257

307

357

80

130

180

230

280

0 50 100 150 200 250 300 350 400

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

A-03

_50H

z_2_

A

2xØ283/1xØ258

3xØ283

1xØ283/2xØ258

3xØ258

0

10

20

30

40

0

5

10

15

NPS

Hr[ft

]

NPS

Hr[m

]

79,4

78,9

78,3

h[%]

80,0

e-MPR, e-MPD, e-MPV e-MPA

e-MP125A/04 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200 1400 1600

0 20 40 60 80 100 120

Q [Imp gpm]

Q [l/s]

4A 4B

4C 4D

0 200 400 600 800 1000 1200 1400 1600 1800

492

692

892

1092

1292

1492

150

200

250

300

350

400

450

500Q [US gpm]

H [ft

]

H[m

]

4A 4B

4C 4D

161

211

261

311

361

411

461

120

170

220

270

320

370

0 50 100 150 200 250 300 350 400 450

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

A-04

_50H

z_2_

A

3xØ283/1xØ258

4xØ283

2xØ283/2xØ258

1xØ283/3xØ258

0

10

20

30

40

0

5

10

15

NPS

Hr[ft

]

NPS

Hr[m

]

80,0

79,5

79,1

78,7

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP125A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 51: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

51

e-MP125A/05 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000 1200 1400 1600

0 20 40 60 80 100 120

Q [Imp gpm]

Q [l/s]

5A 5B 5C 5D

0 200 400 600 800 1000 1200 1400 1600 1800

656

856

1056

1256

1456

1656

1856

200

250

300

350

400

450

500

550

600Q [US gpm]

H [ft

]

H[m

]

5A 5B

5C 5D

201

301

401

501

601

150

200

250

300

350

400

450

0 50 100 150 200 250 300 350 400 450

P [H

P] P

[kW

]

Q [m3/h]

e-M

P125

A-05

_50H

z_2_

A

4xØ283/1xØ258 5xØ283

3xØ283/2xØ258

2xØ283/3xØ258

0

10

20

30

40

0

5

10

15

NPS

Hr[ft

]

NPS

Hr[m

]

80,0

79,6

79,3

79,0

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP125A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 52: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

52

e-MP125B/01 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 500 1000 1500 2000

0 20 40 60 80 100 120 140 160

Q [Imp gpm]

Q [l/s]

1A

1B 1C

82,9

80,7

79,5

78,0

81

81

80

80

78

78

75

75

70 65

1D

0 500 1000 1500 2000 2500

98

148

198

248

298

348

398

30

40

50

60

70

80

90

100

110

120

130Q [US gpm]

H [ft

]

H[m

]

h[%]

0

10

20

30

40

0

5

10

15

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B 1C

1D

54

74

94

114

134

154

174

40

60

80

100

120

140

0 100 200 300 400 500 600

P [H

P] P [k

W]

Q [m3/h]

e-M

P125

B-01

_50H

z_2_

A

Ø295

Ø280

Ø270

Ø255

e-MP125B/02 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 500 1000 1500 2000

0 20 40 60 80 100 120 140 160

Q [Imp gpm]

Q [l/s]

2A

2B

2C 2D

0 500 1000 1500 2000 2500

262

362

462

562

662

762

80

100

120

140

160

180

200

220

240

260Q [US gpm]

H [ft

]

H[m

]

2A

2B

2C

2D

94

144

194

244

294

344

70

120

170

220

270

0 100 200 300 400 500 600

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

B-02

_50H

z_2_

A

1xØ295/1xØ270

2xØ295

2xØ270

2xØ255

0

10

20

30

40

0

5

10

15

NPS

Hr[ft

]

NPS

Hr[m

]

82,8

81,1

79,4

78,0

h[%]

e-MP125B/03 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 500 1000 1500 2000

0 20 40 60 80 100 120 140 160

Q [Imp gpm]

Q [l/s]

3A 3B

3C 3D

0 500 1000 1500 2000 2500

492

592

692

792

892

992

1092

1192

1292

150

200

250

300

350

400Q [US gpm]

H [ft

]

H[m

]

3A 3B

3C 3D

134

234

334

434

534

100

150

200

250

300

350

400

0 100 200 300 400 500 600

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

B-03

_50H

z_2_

A

2xØ295/1xØ270

3xØ295

1xØ295/2xØ270

3xØ270

0

10

20

30

40

0

5

10

15

NPS

Hr[ft

]

NPS

Hr[m

]

81,7

80,6

79,4

h[%]

82,8

e-MP125B/04 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 500 1000 1500 2000

0 20 40 60 80 100 120 140 160

Q [Imp gpm]

Q [l/s]

4A 4B 4C 4D

0 500 1000 1500 2000 2500

656

856

1056

1256

1456

1656

200

250

300

350

400

450

500

550Q [US gpm]

H [ft

]

H[m

]

4A 4B

4C 4D

228

328

428

528

628

170

220

270

320

370

420

470

520

0 100 200 300 400 500 600

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

B-04

_50H

z_2_

A

3xØ295/1xØ270

4xØ295

2xØ295/2xØ270

1xØ295/3xØ270

0

10

20

30

40

0

5

10

15

NPS

Hr[ft

]

NPS

Hr[m

]

82,8

82,0

81,1

80,3

h[%]

e-MP125B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 53: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

53

e-MP125B/05 ~ 2950 [rpm] ISO 9906:2012 - Grade 2B

0 500 1000 1500 2000

0 20 40 60 80 100 120 140 160

Q [Imp gpm]

Q [l/s]

5A 5B 5C 5D

0 500 1000 1500 2000 2500

984

1184

1384

1584

1784

1984

300

350

400

450

500

550

600

650Q [US gpm]

H [ft

]

H[m

]

5A 5B

5C 5D

335

435

535

635

735

835

250

350

450

550

650

0 100 200 300 400 500 600

P [H

P] P

[kW

]

Q [m3/h]

e-M

P125

B-05

_50H

z_2_

A

4xØ295/1xØ270

5xØ295

3xØ295/2xØ270

2xØ295/3xØ270

0

10

20

30

40

0

5

10

15

NPS

Hr[ft

]

NPS

Hr[m

]

82,8 82,2

81,5

80,8

h[%]

e-MP125B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 2 POLES

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 54: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

54

e-MP50A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

e-MP50A/01 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 20 40 60 80 100 120

0 1 2 3 4 5 6 7 8 9

Q [Imp gpm]

Q [l/s]

1A 1B

66,7

64,0

60,5

65

65

60 55

60

55

50

50

1C

0 20 40 60 80 100 120 140

0

5

10

15

20

25

30

0

1

2

3

4

5

6

7

8

9

10Q [US gpm]

H [ft

]

H[m

]

h[%]

0

5

10

15

0

1

2

3

4

5

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

0,0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0

0,1

0,2

0,3

0,4

0,5

0,6

0 5 10 15 20 25 30 35

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50A

-01_

50Hz

_4_A

Ø169

Ø157

Ø145

e-MPR, e-MPD, e-MPV e-MPA

e-MP50A/02-06 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 20 40 60 80 100 120

0 1 2 3 4 5 6 7 8 9

Q [Imp gpm]

Q [l/s]

6A 5A 4A 3A 2A

0 20 40 60 80 100 120 140

0

20

40

60

80

100

120

140

160

180

0

10

20

30

40

50

60Q [US gpm]

H [ft

]

H[m

]

6A

5A

4A

3A

2A

0

0,2

0,4

0,6

0,8

1

1,2

0

0,5

1

1,5

2

2,5

3

3,5

0 5 10 15 20 25 30 35

P [H

P]

P [k

W]

Q [m3/h

e-M

P50A

-2-6

_50H

z_4_

A

5xØ169

6xØ169

4xØ169

3xØ169

2xØ169

0

5

10

15

0

1

2

3

4

5

NPS

Hr[ft

]

NPS

Hr[m

]

66,9

66,9

66,9

66,9

66,9

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP50A/07-10 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 20 40 60 80 100 120

0 1 2 3 4 5 6 7 8 9

Q [Imp gpm]

Q [l/s]

10A 9A 8A 7A

0 20 40 60 80 100 120 140

33

83

133

183

233

283

10

20

30

40

50

60

70

80

90

100Q [US gpm]

H [ft

]

H[m

]

10A 9A 8A 7A

0

2

4

6

8

10

12

0

2

4

6

8

10

0 5 10 15 20 25 30 35

P [H

P]

P [k

W]

Q [m3/h

e-M

P50A

-7-1

0_50

Hz_4

_A

9xØ169

10xØ169

8xØ169

7xØ169

0

5

10

15

0

1

2

3

4

5

NPS

Hr[ft

]

NPS

Hr[m

]

66,9

66,9

66,9

66,9

h[%]

e-MPR, e-MPD, e-MPV e-MPA

e-MP50A/11-14 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 20 40 60 80 100 120

0 1 2 3 4 5 6 7 8 9

Q [Imp gpm]

Q [l/s]

14A 13A 12A 11A

0 20 40 60 80 100 120 140

33

83

133

183

233

283

333

383

433

10

30

50

70

90

110

130

Q [US gpm]

H [ft

] H[m

]

14A 13A 12A 11A

1,3

3,3

5,3

7,3

9,3

1

2

3

4

5

6

7

8

0 5 10 15 20 25 30 35

P [H

P]

P [k

W]

Q [m3/h

e-M

P50A

-11-

14_5

0Hz_

4_A

13xØ169

14xØ169

12xØ169

11xØ169

0

5

10

15

0

1

2

3

4

5

NPS

Hr[ft

]

NPS

Hr[m

]

66,9

66,9

66,9

66,9

h[%]

e-MPR, e-MPD, e-MPV e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 55: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

55

e-MP50A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

e-MP50A/15-18 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 20 40 60 80 100 120

0 1 2 3 4 5 6 7 8 9

Q [Imp gpm]

Q [l/s]

18A 17A 16A 15A

0 20 40 60 80 100 120 140

66

166

266

366

466

566

20

40

60

80

100

120

140

160

180Q [US gpm]

H [ft

]

H[m

]

18A 17A 16A 15A

0

2

4

6

8

10

12

0

2

4

6

8

10

0 5 10 15 20 25 30 35

P [H

P]

P [k

W]

Q [m3/h

e-M

P50A

-15-

18_5

0Hz_

4_A

17xØ169

18xØ169

16xØ169

15xØ169

0

5

10

15

0

1

2

3

4

5

NPS

Hr[ft

]

NPS

Hr[m

]

66,9

66,9

66,9

66,9

h[%]

e-MPR, e-MPD, e-MPV e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 56: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

56

e-MP50B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

e-MP50B/01 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 20 40 60 80 100 120 140 160

0 2 4 6 8 10 12

Q [Imp gpm]

Q [l/s]

1A 1B

72,6

70,0

66,9

70

70

65

65

60

60

55

55

50

50

1C

0 20 40 60 80 100 120 140 160 180

0

5

10

15

20

25

30

35

0

2

4

6

8

10

12Q [US gpm]

H [ft

]

H[m

]

h[%]

0

5

10

0

1

2

3

4

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

0,3

0,4

0,5

0,6

0,7

0,8

0,9

1,0

1,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0 5 10 15 20 25 30 35 40 45

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-01_

50Hz

_4_A

Ø173

Ø161

Ø149

e-MPR, e-MPD, e-MPV

e-MPA

e-MP50B/02-06 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 20 40 60 80 100 120 140

0 2 4 6 8 10

Q [Imp gpm]

Q [l/s]

6A

5A

4A

3A

2A

0 20 40 60 80 100 120 140 160 180

0

50

100

150

200

0

10

20

30

40

50

60

70Q [US gpm]

H [ft

]

H[m

]

6A

5A

4A

3A

2A

0

0,2

0,4

0,6

0,8

1

1,2

0

1

2

3

4

5

0 5 10 15 20 25 30 35 40

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-2-6

_50H

z_4_

A

5xØ173

6xØ173

4xØ173

3xØ173

2xØ173

0

5

10

0

1

2

3

4

NPS

Hr[ft

]

NPS

Hr[m

]

72,6

72,6

72,6

72,6

72,6

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP50B/07-10 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 20 40 60 80 100 120 140 160

0 2 4 6 8 10 12

Q [Imp gpm]

Q [l/s]

10A 9A 8A 7A

0 20 40 60 80 100 120 140 160 180

66

116

166

216

266

316

20

30

40

50

60

70

80

90

100

110Q [US gpm]

H [ft

]

H[m

]

10A 9A

8A

7A

2,7

4,7

6,7

8,7

10,7

2

3

4

5

6

7

8

0 5 10 15 20 25 30 35 40 45

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-7-1

0_50

Hz_4

_A

9xØ173

10xØ173

8xØ173

7xØ173

0

5

10

0

1

2

3

4

NPS

Hr[ft

]

NPS

Hr[m

]

72,6

72,6

72,6

72,6

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP50B/11-14 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 20 40 60 80 100 120 140 160

0 2 4 6 8 10 12

Q [Imp gpm]

Q [l/s]

14A 13A 12A 11A

0 20 40 60 80 100 120 140 160 180

98

148

198

248

298

348

398

448

30

50

70

90

110

130

150Q [US gpm]

H [ft

] H[m

]

14A 13A 12A 11A

4,0

6,0

8,0

10,0

12,0

14,0

3456789

1011

0 5 10 15 20 25 30 35 40 45

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-11-

14_5

0Hz_

4_A

13xØ173

14xØ173

12xØ173

11xØ173

0

5

10

0

1

2

3

4

NPS

Hr[ft

]

NPS

Hr[m

]

72,6

72,6

72,6

72,6

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 57: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

57

e-MP50B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

e-MP50B/15-18 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 20 40 60 80 100 120 140 160

0 2 4 6 8 10 12

Q [Imp gpm]

Q [l/s]

18A 17A 16A 15A

0 20 40 60 80 100 120 140 160 180

131

231

331

431

531

631

40

60

80

100

120

140

160

180

200Q [US gpm]

H [ft

]

H[m

]

18A 17A 16A 15A

5,4

7,4

9,4

11,4

13,4

15,4

17,4

4

6

8

10

12

14

0 5 10 15 20 25 30 35 40 45

P [H

P]

P [k

W]

Q [m3/h]

e-M

P50B

-15-

18_5

0Hz_

4_A

17xØ173

18xØ173

16xØ173

15xØ173

0

5

10

0

1

2

3

4

NPS

Hr[ft

]

NPS

Hr[m

]

72,6

72,6

72,6

72,6

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 58: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

58

e-MP65A/01 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 2 4 6 8 10 12 14 16 18

Q [Imp gpm]

Q [l/s]

1A 1B

75,7

71,8

68,2

72

72

70

70

65

65

60

60

55 50

1C

0 50 100 150 200 250 300

0

10

20

30

40

50

0

2

4

6

8

10

12

14

16Q [US gpm]

H [ft

]

H[m

]

h[%]

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

1A 1B

1C

0,0

0,5

1,0

1,5

2,0

2,5

0

0,5

1

1,5

2

0 10 20 30 40 50 60 70

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65A

-01_

50Hz

_4_A

Ø206

Ø190

Ø174

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65A/02-06 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 2 4 6 8 10 12 14 16 18

Q [Imp gpm]

Q [l/s]

6A

5A

4A

3A

2A

0 50 100 150 200 250 300

0

50

100

150

200

250

0

10

20

30

40

50

60

70

80

90Q [US gpm]

H [ft

]

H[m

]

6A

5A

4A

3A

2A

0

2

4

6

8

10

12

0

2

4

6

8

10

0 10 20 30 40 50 60 70

P [H

P]

P [k

W]

Q [m3/h

e-M

P65A

-2-6

_50H

z_4_

A

5xØ206

6xØ206

4xØ206

3xØ206

2xØ206

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

75,7

75,7

75,7

75,7

75,7

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65A/07-11 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 2 4 6 8 10 12 14 16 18

Q [Imp gpm]

Q [l/s]

11A 10A 9A 8A 7A

0 50 100 150 200 250 300

66

116

166

216

266

316

366

416

466

516

20

40

60

80

100

120

140

160Q [US gpm]

H [ft

] H[m

]

11A

10A 9A 8A 7A

5,4

10,4

15,4

20,4

4

6

8

10

12

14

16

18

0 10 20 30 40 50 60 70

P [H

P]

P [k

W]

Q [m3/h

e-M

P65A

-7-1

1_50

Hz_4

_A

10xØ206

11xØ206

9xØ206

8xØ206

7xØ206

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

75,7

75,7

75,7

75,7

75,7

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65A/12-15 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 2 4 6 8 10 12 14 16 18

Q [Imp gpm]

Q [l/s]

15A 14A 13A 12A

0 50 100 150 200 250 300

131

231

331

431

531

631

40

60

80

100

120

140

160

180

200

220Q [US gpm]

H [ft

]

H[m

]

15A 14A 13A 12A

6,7

11,7

16,7

21,7

26,7

31,7

5

10

15

20

25

0 10 20 30 40 50 60 70

P [H

P]

P [k

W]

Q [m3/h

e-M

P65A

-12-

15_5

0Hz_

4_A

14xØ206

15xØ206

13xØ206

12xØ206

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

75,7

75,7

75,7

75,7

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 59: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

59

e-MP65B/01 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250

0 5 10 15 20 25

Q [Imp gpm]

Q [l/s]

1A

1B

78,5

76,5

73,6

76

76

73

73

70

70

65

65

60 55

1C

0 50 100 150 200 250 300 350

13

18

23

28

33

38

43

48

4

6

8

10

12

14

16Q [US gpm]

H [ft

]

H[m

]

h[%]

0

2

4

6

8

0

1

2

3

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

0,0

0,5

1,0

1,5

2,0

2,5

3,0

0

0,5

1

1,5

2

2,5

0 10 20 30 40 50 60 70 80 90

P [H

P]

P [k

W]

Q [m3/h]

e-M

P65B

-01_

50Hz

_4_A

Ø214

Ø200

Ø186

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B/02-06 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250 300

0 5 10 15 20 25

Q [Imp gpm]

Q [l/s]

6A

5A

4A

3A

2A

0 50 100 150 200 250 300 350

0

50

100

150

200

250

300

0

10

20

30

40

50

60

70

80

90

100Q [US gpm]

H [ft

] H[m

]

6A

5A

4A

3A

2A

0

5

10

15

0

2

4

6

8

10

12

14

0 10 20 30 40 50 60 70 80 90

P [H

P]

P [k

W]

Q [m3/h

e-M

P65B

-2-6

_50H

z_4_

A

5xØ214

6xØ214

4xØ214

3xØ214

2xØ214

0

2

4

6

8

0

1

2

3

NPS

Hr[ft

]

NPS

Hr[m

]

78,5

78,5

78,5

78,5

78,5

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B/07-11 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250 300

0 5 10 15 20 25

Q [Imp gpm]

Q [l/s]

11A 10A

9A 8A 7A

0 50 100 150 200 250 300 350

131

181

231

281

331

381

431

481

531

581

40

60

80

100

120

140

160

180Q [US gpm]

H [ft

] H[m

]

11A 10A 9A 8A 7A

6,7

11,7

16,7

21,7

26,7

31,7

5

10

15

20

25

0 10 20 30 40 50 60 70 80 90

P [H

P]

P [k

W]

Q [m3/h

e-M

P65B

-7-1

1_50

Hz_4

_A

10xØ214

11xØ214

9xØ214

8xØ214

7xØ214

0

2

4

6

8

0

1

2

3

NPS

Hr[ft

]

NPS

Hr[m

]

78,5

78,5

78,5

78,5

78,5

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B/12-15 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250 300

0 5 10 15 20 25

Q [Imp gpm]

Q [l/s]

15A 14A 13A 12A

0 50 100 150 200 250 300 350

230

330

430

530

630

730

70

90

110

130

150

170

190

210

230Q [US gpm]

H [ft

] H[m

]

15A 14A 13A 12A

13,4

18,4

23,4

28,4

33,4

38,4

43,4

10

15

20

25

30

35

0 10 20 30 40 50 60 70 80 90

P [H

P]

P [k

W]

Q [m3/h

e-M

P65B

-12-

15_5

0Hz_

4_A

14xØ214

15xØ214

13xØ214

12xØ214

0

2

4

6

8

0

1

2

3

NPS

Hr[ft

]

NPS

Hr[m

]

78,5

78,5

78,5

78,5

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP65B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 60: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

60

e-MP100A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

e-MP100A/01 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250 300 350 400

0 5 10 15 20 25 30

Q [Imp gpm]

Q [l/s]

1A

1B 1C

74,5

71,8

67,3

61,7

73

73

70

70

65

65

60 50

60

1D

0 100 200 300 400 500

0

10

20

30

40

50

60

70

80

0

5

10

15

20

25Q [US gpm]

H [ft

]

H[m

]

h[%]

0

5

10

15

0

1

2

3

4

5

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

1D

0

1

2

3

4

5

6

0

1

2

3

4

5

0 20 40 60 80 100 120

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

A-01

_50H

z_4_

A

Ø242

Ø224

Ø206

Ø188

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100A/02 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250 300 350 400

0 5 10 15 20 25 30

Q [Imp gpm]

Q [l/s]

2A

2B

2C

0 100 200 300 400 500

16

36

56

76

96

116

136

5

10

15

20

25

30

35

40

45Q [US gpm]

H [ft

]

H[m

]

2A

2B

2C

0

2

4

6

8

10

12

0

2

4

6

8

10

0 20 40 60 80 100 120

P [H

P]

P [k

W]

Q [m3/h

e-M

P100

A-02

_50H

z_4_

A

2xØ224

2xØ242

2xØ206

0

5

10

15

0

1

2

3

4

5

NPS

Hr[ft

]

NPS

Hr[m

]

74,5

71,7

67,2

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100A/03 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250 300 350 400

0 5 10 15 20 25 30

Q [Imp gpm]

Q [l/s]

3A

3B

0 100 200 300 400 500

49

99

149

199

15

20

25

30

35

40

45

50

55

60

65Q [US gpm]

H [ft

]

H[m

]

3A

3B

0

5

10

15

20

25

0

5

10

15

20

0 20 40 60 80 100 120

P [H

P]

P [k

W]

Q [m3/h

e-M

P100

A-03

_50H

z_4_

A

3xØ242

3xØ224

0

5

10

15

0

1

2

3

4

5

NPS

Hr[ft

]

NPS

Hr[m

]

74,5

71,7

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100A/04 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250 300 350 400

0 5 10 15 20 25 30

Q [Imp gpm]

Q [l/s]

4A

4B

0 100 200 300 400 500

66

116

166

216

266

20

30

40

50

60

70

80

90Q [US gpm]

H [ft

]

H[m

]

4A

4B

0

5

10

15

20

25

0

5

10

15

20

0 20 40 60 80 100 120

P [H

P]

P [k

W]

Q [m3/h

e-M

P100

A-04

_50H

z_4_

A

4xØ242

1xØ242/3xØ224

0

5

10

15

0

1

2

3

4

5

NPS

Hr[ft

]

NPS

Hr[m

]

74,5

72,4

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 61: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

61

e-MP100A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

e-MP100A/05 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250 300 350 400

0 5 10 15 20 25 30

Q [Imp gpm]

Q [l/s]

5A 5B

0 100 200 300 400 500

66

116

166

216

266

316

366

20

30

40

50

60

70

80

90

100

110

120Q [US gpm]

H [ft

]

H[m

]

5A

5B

7

12

17

22

27

32

5

10

15

20

25

0 20 40 60 80 100 120

P [H

P]

P [k

W]

Q [m3/h

e-M

P100

A-05

_50H

z_4_

A

5xØ242

2xØ242/3xØ224

0

5

10

15

0

1

2

3

4

5

NPS

Hr[ft

]

NPS

Hr[m

]

74,5

72,9

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100A/06 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 50 100 150 200 250 300 350 400

0 5 10 15 20 25 30

Q [Imp gpm]

Q [l/s]

6A 6B

0 100 200 300 400 500

66

116

166

216

266

316

366

416

20

40

60

80

100

120

140Q [US gpm]

H [ft

] H[m

]

6A

6B

7

12

17

22

27

32

5

10

15

20

25

0 20 40 60 80 100 120

P [H

P]

P [k

W]

Q [m3/h

e-M

P100

A-06

_50H

z_4_

A

6xØ242

3xØ242/3xØ224

0

5

10

15

0

1

2

3

4

5

NPS

Hr[ft

]

NPS

Hr[m

]

74,5

73,1

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 62: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

62

e-MP100B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

e-MP100B/01 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

1A 1B

1C

79,1

75,9

70,7

63,6

77

77

75

75

70

70

65

65

60

60

1D

0 100 200 300 400 500 600 700

0

10

20

30

40

50

60

70

80

0

5

10

15

20

25Q [US gpm]

H [ft

]

H[m

]

h[%]

0

2

4

6

8

0

1

2

3

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

1D

0

1

2

3

4

5

6

7

8

0

1

2

3

4

5

6

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

B-01

_50H

z_4_

A

Ø245

Ø226

Ø207

Ø188

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100B/02 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

2A

2B

2C

0 100 200 300 400 500 600 700

16

36

56

76

96

116

136

5

10

15

20

25

30

35

40

45Q [US gpm]

H [ft

]

H[m

]

2A

2B

2C

3

5

7

9

11

13

15

2

4

6

8

10

12

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

B-02

_50H

z_4_

A

2xØ226

2xØ242

2xØ207

0

2

4

6

8

0

1

2

3

NPS

Hr[ft

]

NPS

Hr[m

]

79,1

75,8

70,6

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100B/03 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

3A

3B

0 100 200 300 400 500 600 700

49

69

89

109

129

149

169

189

209

15

20

25

30

35

40

45

50

55

60

65Q [US gpm]

H [ft

]

H[m

]

3A

3B

7

12

17

22

27

5

10

15

20

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

B-03

_50H

z_4_

A

3xØ245

3xØ226

0

2

4

6

8

0

1

2

3

NPS

Hr[ft

]

NPS

Hr[m

]

79,1

75,8

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100B/04 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

4A

4B

0 100 200 300 400 500 600 700

33

83

133

183

233

283

10

20

30

40

50

60

70

80

90Q [US gpm]

H [ft

]

H[m

]

4A

4B

7

12

17

22

27

32

5

10

15

20

25

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

B-04

_50H

z_4_

A

4xØ245

1xØ245/3xØ226

0

2

4

6

8

0

1

2

3

NPS

Hr[ft

]

NPS

Hr[m

]

79,1

76,6

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 63: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

63

e-MP100B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

e-MP100B/05 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

5A 5B

0 100 200 300 400 500 600 700

66

116

166

216

266

316

20

30

40

50

60

70

80

90

100

110Q [US gpm]

H [ft

]

H[m

]

5A

5B

13

18

23

28

33

38

10

15

20

25

30

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

B-05

_50H

z_4_

A

5xØ245

2xØ245/3xØ226

0

2

4

6

8

0

1

2

3

NPS

Hr[ft

]

NPS

Hr[m

]

79,1

77,1

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100B/06 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

6A

6B

0 100 200 300 400 500 600 700

66

116

166

216

266

316

366

416

20

40

60

80

100

120

140Q [US gpm]

H [ft

] H[m

]

6A

6B

13

18

23

28

33

38

43

10

15

20

25

30

35

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

B-06

_50H

z_4_

A

6xØ245

3xØ245/3xØ226

0

2

4

6

8

0

1

2

3

NPS

Hr[ft

]

NPS

Hr[m

]

79,1

77,5

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP100B/07 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500

0 5 10 15 20 25 30 35 40

Q [Imp gpm]

Q [l/s]

7A

7B

0 100 200 300 400 500 600 700

66

116

166

216

266

316

366

416

466

516

20

40

60

80

100

120

140

160Q [US gpm]

H [ft

]

H[m

]

7A

7B

20

25

30

35

40

45

50

15

20

25

30

35

40

0 20 40 60 80 100 120 140 160

P [H

P]

P [k

W]

Q [m3/h]

e-M

P100

B-07

_50H

z_4_

A

7xØ245

4xØ245/3xØ226

0

2

4

6

8

0

1

2

3

NPS

Hr[ft

]

NPS

Hr[m

]

79,1

77,7

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 64: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

64

e-MP125A/01 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500 600 700 800 900

0 10 20 30 40 50 60

Q [Imp gpm]

Q [l/s]

1A

1B

79,6

78,2

75,8

78

78

75

75

70

65

65

60

60

50

1C

0 200 400 600 800 1000

16

26

36

46

56

66

76

86

96

5

10

15

20

25

30Q [US gpm]

H [ft

]

H[m

] h[%]

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

4

6

8

10

12

14

3

4

5

6

7

8

9

10

11

0 50 100 150 200 250

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

A-01

_50H

z_4_

A

Ø283

Ø263

Ø243

~

e-MPR, e-MPD, e-MPV e-MPA

e-MP125A/02 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500 600 700 800 900

0 10 20 30 40 50 60

Q [Imp gpm]

Q [l/s]

2A

2B

2C

0 200 400 600 800 1000

33

53

73

93

113

133

153

173

193

10

15

20

25

30

35

40

45

50

55

60Q [US gpm]

H [ft

]

H[m

]

2A

2B

2C

7

12

17

22

27

32

5

10

15

20

25

0 50 100 150 200 250

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

A-02

_50H

z_4_

A

2xØ263

2xØ283

2xØ243

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

79,6

78,2

75,8

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP125A/03 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500 600 700 800 900

0 10 20 30 40 50 60

Q [Imp gpm]

Q [l/s]

3A 3B 3C

0 200 400 600 800 1000

66

116

166

216

266

20

30

40

50

60

70

80

90Q [US gpm]

H [ft

]

H[m

]

3A

3B

3C

13

18

23

28

33

38

43

10

15

20

25

30

35

0 50 100 150 200 250

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

A-03

_50H

z_4_

A

1xØ283/2xØ263

3xØ283

1xØ283/2xØ243

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

78,7

77,0

h[%] 79,6

e-MPR, e-MPD, e-MPV

e-MPA

e-MP125A/04 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 100 200 300 400 500 600 700 800 900

0 10 20 30 40 50 60

Q [Imp gpm]

Q [l/s]

4A

4B 4C

0 200 400 600 800 1000

66

116

166

216

266

316

366

20

30

40

50

60

70

80

90

100

110

120Q [US gpm]

H [ft

]

H[m

]

4A

4B

4C

20

30

40

50

60

15

20

25

30

35

40

45

0 50 100 150 200 250

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

A-04

_50H

z_4_

A

2xØ283/2xØ263

4xØ283

2xØ283/2xØ243

0

10

20

30

0

2

4

6

8

10

NPS

Hr[ft

]

NPS

Hr[m

]

79,6

78,9 77,6

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP125A SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 65: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

65

e-MP125B/01 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000

0 10 20 30 40 50 60 70 80

Q [Imp gpm]

Q [l/s]

1A

1B

80,1

78,0

76,7

78

78

75

75

70

65

65

60

60

50

1C

0 200 400 600 800 1000 1200

0

20

40

60

80

100

0

5

10

15

20

25

30

35Q [US gpm]

H [ft

] H[m

]

h[%]

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

1A

1B

1C

5

7

9

11

13

15

17

19

21

4

6

8

10

12

14

16

0 50 100 150 200 250 300

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

B-01

_50H

z_4_

A

Ø295

Ø275

Ø255

e-MPR, e-MPD, e-MPV

e-MPA

e-MP125B/02 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000

0 10 20 30 40 50 60 70 80

Q [Imp gpm]

Q [l/s]

2A

2B 2C

0 200 400 600 800 1000 1200

33

53

73

93

113

133

153

173

193

213

10

20

30

40

50

60

70Q [US gpm]

H [ft

]

H[m

]

2A

2B

2C

7

17

27

37

47

5

10

15

20

25

30

35

0 50 100 150 200 250 300

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

B-02

_50H

z_4_

A

2xØ275

2xØ295

2xØ255

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

80,1

78,0

76,7

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP125B/03 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000

0 10 20 30 40 50 60 70 80

Q [Imp gpm]

Q [l/s]

3A

3B

3C

0 200 400 600 800 1000 1200

66

116

166

216

266

316

20

30

40

50

60

70

80

90

100Q [US gpm]

H [ft

]

H[m

]

3A

3B

3C

20

30

40

50

60

15

20

25

30

35

40

45

0 50 100 150 200 250 300

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

B-03

_50H

z_4_

A

1xØ295/2xØ275

3xØ295

1xØ295/2xØ255

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

78,7

77,5

h[%] 80,1

e-MPR, e-MPD, e-MPV

e-MPA

e-MP125B/04 ~ 1450 [rpm] ISO 9906:2012 - Grade 2B

0 200 400 600 800 1000

0 10 20 30 40 50 60 70 80

Q [Imp gpm]

Q [l/s]

4A 4B

4C

0 200 400 600 800 1000 1200

66

116

166

216

266

316

366

416

20

40

60

80

100

120

140Q [US gpm]

H [ft

]

H[m

]

4A 4B

4C

20

30

40

50

60

70

80

15

25

35

45

55

65

0 50 100 150 200 250 300

P [H

P]

P [k

W]

Q [m3/h]

e-M

P125

B-04

_50H

z_4_

A

2xØ295/2xØ275

4xØ295

2xØ295/2xØ255

0

10

20

0

2

4

6

8

NPS

Hr[ft

]

NPS

Hr[m

]

80,1

79,0 78,1

h[%]

e-MPR, e-MPD, e-MPV

e-MPA

e-MP125B SERIESOPERATING CHARACTERISTICS AT 50 Hz, 4 POLES

These performances are valid for cold water with density ρ = 1.0 Kg/dm3and viscosity ν = 1 mm2/sec.

Page 66: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

66

Page 67: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

67

DIMENSIONSAND wEIGHTS

Page 68: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

68

for MPA:

Code: AO Code: AL Code: AR

for MPD and MPR:

Code: LO Code: RO Code: OO

Code: RRCode: ORCode: LR

Code: RL Code: OL Code: LL

e-MP-NOZ-EN_a_DD

Note: Nozzle position LL, OO, RR is not possible for pumps with 1 and 2 stages

MPA, MPD AND MPR SERIESNOZZLE POSITION

To be selected in Xylect

Page 69: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

69

MPA SERIESDIMENSIONS AND wEIGHTS AT 50 Hz

a1 f

ym1

m4 m3m2 m2

d1 bn2n1

h1h2

l

s1

v1

u

t

d

h2h2

Position Connection SizePM1 Vacuum gauge G 14

PM2 Pressure gauge G 14

D Drain G 14

G Grease nipple M8

L Leakage G 12

V Vent G 14

G

LD

V PM2DND

DNS

PM1

e-MPA-EN_a_DD

e-MPA-en_a_td

e-MPA-stage-en_a_td

NOTE:PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest. For flanges dimensions see drawing on pages 90-91.

Page 70: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

70

MPA SERIESDIMENSIONS AND wEIGHTS AT 50 Hz

e-MPA-AS-EN_a_DD

G

LD

VPM2DND

DNS

PM1

a1 f 4

L4

L max.

B2B1

Hh2

H max.

L3 L2 L2L1

s

h2 h2

Position Connection SizePM1 Vacuum gauge G 14

PM2 Pressure gauge G 14

D Drain G 14

G Grease nipple M8

L Leakage G 12

V Vent G 14

LIFTING HOLES

EARTHING

Page 71: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

71

MPA SERIES - Size 50DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPA-AS-50-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.For flanges dimensions see drawing on pages 90-91.

Page 72: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

72

MPA SERIES - Size 65DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPA-AS-65-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.For flanges dimensions see drawing on pages 90-91.

Page 73: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

73

MPA SERIES - Size 100DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPA-AS-100-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.For flanges dimensions see drawing on pages 90-91.

Page 74: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

74

MPA SERIES - Size 125DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPA-AS-125-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.For flanges dimensions see drawing on pages 90-91.

Page 75: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

75

MPR SERIESDIMENSIONS AND wEIGHTS AT 50 Hz

a f

ym

m4 m3m2 m2

d1 bn2n1

h1h2

h2

l

s1

v

u

t

d

h2

Position Connection SizePM1 Vacuum gauge G 14

PM2 Pressure gauge G 14

D Drain G 14

G Grease nipple M8

L Leakage G 12

V Vent G 14

G

LD

V PM2

DNS

DND

PM1

e-MPR-EN_a_DD

e-MPR-en_a_td

e-MPR-stage-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.Forflangesdimensionsseedrawingonpages92-93.

Page 76: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

76

e-MPR-AS-EN_a_DD

G

LD

VPM2DND

DNS

PM1

a f 4

L4

L max.

B2B1

Hh2

H max.

L3 L2 L2L1

s

h2

Position Connection SizePM1 Vacuum gauge G 14

PM2 Pressure gauge G 14

D Drain G 14

G Grease nipple M8

L Leakage G 12

V Vent G 14

LIFTING HOLES

EARTHING

MPR SERIESDIMENSIONS AND wEIGHTS AT 50 Hz

Page 77: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

77

MPR SERIES - Size 50DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPR-AS-50-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.Forflangesdimensionsseedrawingonpages92-93.

Page 78: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

78

MPR SERIES - Size 65DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPR-AS-65-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.Forflangesdimensionsseedrawingonpages92-93.

Page 79: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

79

MPR SERIES - Size 100DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPR-AS-100-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.Forflangesdimensionsseedrawingonpages92-93.

Page 80: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

80

MPR SERIES - Size 125DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPR-AS-125-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.Forflangesdimensionsseedrawingonpages92-93.

Page 81: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

81

MPD SERIESDIMENSIONS AND wEIGHTS AT 50 Hz

e a f

ym

m4 m3m2 m2

d1 bn2n1

h1

h2

h2

l

s1

v

u

t

d

h2

Position Connection SizePM1 Vacuum gauge G 14

PM2 Pressure gauge G 14

D Drain G 14

G Grease nipple M8

L Leakage G 12

V Vent G 14

G G

LLD

V PM2DND

PM1

DNS

e-MPD-EN_a_DD

e-MPD-en_a_td

e-MPD-stage-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.Forflangesdimensionsseedrawingonpages92-93.

Page 82: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

82

MPD SERIESDIMENSIONS AND wEIGHTS AT 50 Hz

e-MPD-AS-EN_a_DD

G

LD

VPM2DND

DNS

PM1G

L

a f 4

L4

L max.

B2B1

Hh2

H max.

L3 L2 L2L1

s

eh2h2

Position Connection SizePM1 Vacuum gauge G 14

PM2 Pressure gauge G 14

D Drain G 14

G Grease nipple M8

L Leakage G 12

V Vent G 14

LIFTING HOLES

EARTHING

Page 83: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

83

MPD SERIES - Size 50DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPD-AS-50-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.Forflangesdimensionsseedrawingonpages92-93.

Page 84: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

84

MPD SERIES - Size 65DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPD-AS-65-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.Forflangesdimensionsseedrawingonpages92-93.

Page 85: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

85

MPD SERIES - Size 100DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPD-AS-100-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.Forflangesdimensionsseedrawingonpages92-93.

Page 86: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

86

MPD SERIES - Size 125DIMENSIONS AND wEIGHTS AT 50 Hz

e-MPD-AS-125-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.Forflangesdimensionsseedrawingonpages92-93.

Page 87: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

87

MPV SERIESDIMENSIONS AND wEIGHTS AT 50 Hz

d

t

u

v2

t1

AD

� b11

� e1

Ød2

� m6� m5

h2

s2

lE

Ød

4-6

h5

ØDØP

h4

ah3

DND

DNS

G

D

PM2

PM1

g (optional)

DND

terminal box position

code-K1 code-K2 code-K3 code-K4

nozzle position

code-OO code-OG code-OL code-OR

pump shaft end

e-MPV-AS_a_DD

standard

design OG: standard for 1 and 2 stages (OO not possible)design OO: standard for 3 or more stages

Page 88: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

88

MPV SERIESDIMENSIONS AND wEIGHTS AT 50 Hz

e-MPV-en_a_td

e-MPV-stage-en_a_td

NOTE.PumpssuppliedwithflangesaccordingtoEN1092-2asstandard;availableASMEB16.5versiononrequest.Forflangesdimensionsseedrawingonpages92-93.

Page 89: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

89

MPV SERIESDIMENSIONS AND wEIGHTS AT 50 Hz

± e-MPV-AS-en_a_td

Page 90: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

90

MPA SERIESFLANGE DIMENSIONS (EN1092-1, EN1092-2)

ØDNDØdf2ØK2ØD2

C2

ØDNS

Ødf1

ØK1

ØD1

C1

e-MPA-FL-EN_a_DD

nxØL2

nxØL1

e-MPA-FL-EN-en_a_td

Page 91: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

91

MPA SERIESFLANGE DIMENSIONS (ASME B16.5)

ØDNDØdf2ØK2ØD2

C2

ØDNS

Ødf1

ØK1

ØD1

C1

e-MPA-FL-EN_a_DD

nxØL2

nxØL1

e-MPA-FL-ASME-en_a_td

Page 92: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

92

MPD, MPR, MPV SERIESFLANGE DIMENSIONS (EN1092-1, EN1092-2)

ØDNSØdf1ØK1ØD1

C1

ØDNDØdf2ØK2ØD2

C2

e-MP-FL-EN_a_DD

nxØL1 nxØL2

e-MP-FL-EN-en_a_td

Page 93: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

93

MPD, MPR, MPV SERIESFLANGE DIMENSIONS (ASME B16.5)

e-MP-FL-ASME-en_a_td

ØDNSØdf1ØK1ØD1

C1

ØDNDØdf2ØK2ØD2

C2

e-MP-FL-EN_a_DD

nxØL1 nxØL2

Page 94: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

94

Page 95: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

95

e-MPwith

HYDROVAR®

(HVL series)

Page 96: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

96

MP..H SERIES(e-MP wITH HYDROVAR)Background and contextFor all pumping needs in commercial or residential building and in industry applications, the demand for intelligent pumping systems is constantly growing. Controlled systems offer many advantages: reduced operating costs for the lifetime of the pump, lower environmental impact, longer lifetime of piping systems and networks. For this reason, Lowara has developed the MP..H: an intelligent pumping system which assures high level performance with energy consumption tailored to the system’s demand.

Benefits of e-MP with HYDROVAR

Saving: MP..H transforms the e-MP pumps into variable speed intelligent pumping systems. Thanks to the HYDROVAR, the speed of each pump varies so as to maintain a constant flow, a constant pressure, or a differential pressure. In doing so, at any point in time, the pump only receives the energy required. This in turns allows for considerable savings, especially for systems that have varying loads throughout the day.

Easy installation and space-saving: MP..H saves time and space during installation. The Hydrovar is delivered already mounted on the motor (for models up to 22kW). The hydrovar is kept cool by the motor fan and does not require a control panel. In order to function, only fuses on the supply line are needed (Check your local electrical installation regulations).

Key Features of the HYDROVAR• No need for additional pressure sensors: The MP..H is fitted as standard with two pressure transmitters, normally fitted on the flanges.

• No need for special pumps or motors.

• MP..H is already pre-wired.

• No need for IN LINE filters. HYDROVAR already includes the THDi filter embedded as standard.

• No need for bypass or safety systems: The MP..H will immediately switch off when demand drops to zero or when it exceeds maximum pump capacity; thus making installation of additional safety devices unnecessary.

• Anti-condensation device: The HYDROVAR is fitted with anti-condensation devices which switch on when the pump is in standby in order to prevent condensation forming in the unit.

HYDROVAR HVL: 1,5kW to 22kW, can be mounted to motor or wallHYDROVAR SMART: Over 22kW, combines all HYDROVAR intelligence with any frequency drive, and can be installed anywhere due to its slim design (e.g. inside of the control panel)

Features HYDROVAR HVL HYDROVAR SMARTFits onto any standard asynchronous motor • -Advanced motor control • •THDi filter embedded • on request

Extended communication capabilities • •Easy to commissionand operate • •Multi-pump capability upto8 up to 4

Page 97: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

97

MP..H SERIES(e-MP wITH HYDROVAR)

16

Lowara

OPERATING PRINCIPLE

The basic function of the HYDROVAR® device is tocontrol the pump to meet the system demands.

HYDROVAR® performs these functions by:1) Measuring the system pressure or flow via a

transmitter mounted on the pump’s delivery side.2) Calculating the motor speed to maintain the correct

flow or pressure.3) Sending out a signal to the pump to start the motor,

increase speed, decrease speed or stop.4) In the case of multiple pump installations,

HYDROVAR® will automatically provide for the cyclicchangeover of the pumps’ starting sequence

In addition to these basic functions, HYDROVAR® can dothings only by the most advanced computerised controlsystems, such as:• Stop the pump(s) at zero demand.• Stop the pump(s) in case of water failure on the

suction side (protection against dry running).• Stop the pump if the required delivery exceeds the

pump’s capacity (protection against cavitation causedby excessive demand), or automatically switch on thenext pump in a multiple series.

• Protect the pump and motor from overvoltage,undervoltage, overload and earth fault.

• Vary the pump speed acceleration and decelerationtime.

• Compensate for increased flow resistance at high flowrates.

• Conduct automatic test starts at set intervals.• Monitor the converter and motor operating hours.• Display all functions on an LCD in different languages

(Italian, English, French, German, Spanish, Portuguese,Dutch).

• Send a signal to a remote control system which isproportional to the pressure and frequency.

• Communicate with another HYDROVAR or controlsystem via an RS 485 interface.

Control for constant pressure

Control to match a system curve

Control for constant flow

Control according to an external signal

TYPICAL EXAMPLE OF ENERGY SAVINGSSystem: SV1608F75T vertical multistage electric pump with 7.5 kW motor equipped with Hydrovar, 80 m head. 12hour/day operation.Application: maintaining a constant pressure as the flow rate varies.

FLOW ABSORBED POWER POWER OPERATING TOTALCONSTANT SPEED VARIABLE SPEED SAVED TIME ENERGY

PUMP PUMP SAVINGS

m3/h kW kW kW (hours) kWh

9 5,50 3,09 2,41 1095 263914 6,71 4,81 1,90 2190 416121 7,30 7,21 0,09 1095 99

YEARLY ENERGY SAVINGS (kWh) 6899

The basic function of the HYDROVAR device is to control the pump to meet the system demands.

HYDROVAR performs these functions by:

1) Measuring the system pressure or flow via a transmitter mounted on the pump’s delivery side.2) Calculating the motor speed to maintain the correct flow or pressure.3)Sendingoutasignaltothepumptostartthemotor, increase speed, decrease speed or stop.4) In the case of multiple pump installations, HYDROVAR will automatically provide for the cyclic changeover of the pumps’ starting sequence.

In addition to these basic functions, HYDROVAR can perform controls only manageable by the most advanced computerized control systems. Some examples are:

•Stopthepump(s)atzerodemand.•Stopthepump(s)incaseofwaterfailureonthesuction side (protection against dry running).•Stopthepumpiftherequireddeliveryexceedsthepump’s capacity (protection against cavitation caused by excessive demand), or automatically switch on the next pump in a multiple series.•Protectthepumpandmotorfromover-voltage,under- voltage, overload, and earth fault.•Varythepumpspeed:accelerationanddecelerationtime.•Compensateforincreasedflowresistanceathighflow rates.•Conductautomatictestsatsetintervals.•Monitortheconverterandmotoroperatinghours.•Displaytheenergyconsumption(kWh).•DisplayallfunctionsonanLCDindifferentlanguages (Italian, English, French, German, Spanish, Portuguese, Dutch, etc...).•Sendasignaltoaremotecontrolsystemwhichis proportional to the pressure and frequency.•CommunicatewithexternalcontrolsystemviaModbus(RS485interface)andBacnetasstandard.

Page 98: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

98

HYDROVAR HVLIDENTIFICATION CODE

Name [3 digits][HVL] = HYDROVAR® generation L

Power supply [2 digits][2.]=1~208-240V(50/60Hz)[3.]=3~208-240V(50/60Hz)[4.]=3~380-460V(50/60Hz)

Rated output power[3 digits]kW x 10

Enclosure class (IP class) [1 digit][A] = IP55 (Type1)[B] = reserved for future use

Bus communication [1 digit] 0 = Standard Communication (Modbus, Bacnet)1 = reserved for future use2 = reserved for future use3=reservedforfutureuse4 = reserved for future use5 = reserved for future use6=reservedforfutureuse7 = Wifi Card (option supplied loose)

Optional cards [1 digit][0] = no optional cards (as standard)[1] = Premium Card (option supplied loose)

Display [1 digit][0] = reserved for future use[1] = Internal display installed as standard

Other options [1 digit][0] = reserved for future use

H V L 4 . 0 7 5 - A 0 0 1 0

DIMENSIONS AND wEIGHTS

B

H

L

X

HVL_dim-en_b_td

EXAMPLE: HVL4.075-A0010

HVL=HYDROVAR generation L, 4.=3~380-460Vpowersupply,075=7,5kW rated output power, A=IP55 (Type1) enclosure class, 0=Standard Bus communication, 0=no optional card, 1=internal display installed, 0=no other options installed.NOTE:HYDROVARoutputvoltageisthreephase.

Page 99: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

99

EMC requirementsHYDROVARfulfillstheproductstandardEN61800-3:2004+A1:2012,whichdefinescategories(C1toC4)fordeviceapplication areas.Dependingonthemotorcablelength,aclassificationofHYDROVARbycategory(basedonEN61800-3)isreportedin the following tables:

HYDROVAR HVLEMC COMPATIBILITY

HVL HYDROVAR classification by categories based on EN61800-3

2.015 ÷ 2.040 C1 (*)

3.015÷3.110 C2 (*)

4.015 ÷ 4.220 C2 (*)

(*) 0,75 motor cable length; contact Xylem for further information En-Rev_A

CARDPremium Card HYDROVAR (optional)

For the e-MPH series, the Premium Card comes fitted as option on the standalone HYDROVAR.This allows to control up to five fix speed pumps via an external panel.The Premium Card will allow additional features listed below: •2additionalAnalogInputs •2AnalogOutputs •1additionaldigitalinput •5relays.

wi-Fi Card HYDROVAR (optional)

With the WiFi card fitted in the HYDROVAR, the unit can will allow you to be connected to a wireless network.

Sensors

The following sensors are available for HYDROVAR: a. Pressure-transducer b. Differential pressure-transducer c. Temperature-sensor d. Flow indicator (orifice plate, inductive flow meter) e. Level-sensor.

OPTIONAL COMPONENTS

Page 100: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

100

HYDROVAR HVL (wALL MOUNTING KIT)DIMENSIONS AND wEIGHTS

AH

L

P

WM-KIT_HVL_models_a_sc

A H L P HVL WM KIT

WM KIT HVL 2.015 1,5 220 170 202 232 5,6 2,6

WM KIT HVL 2.022 2,2 220 170 202 232 5,6 2,6

WM KIT HVL 2.030 3 240 175 258 290 10,5 8,2

WM KIT HVL 2.040 4 320 175 288 305 10,5 5,4

WM KIT HVL 3.015 1,5 220 170 202 232 5,6 2,6

WM KIT HVL 3.022 2,2 220 170 202 232 5,6 2,6

WM KIT HVL 3.030 3 240 175 258 290 10,5 8,2

WM KIT HVL 3.040 4 240 175 258 290 10,5 8,2

WM KIT HVL 3.055 5,5 240 175 258 290 10,5 8,2

WM KIT HVL 3.075 7,5 400 200 325 365 15,6 11,6

WM KIT HVL 3.110 11 400 200 325 365 15,6 11,6

WM KIT HVL 4.015 1,5 240 170 258 290 5,6 8,2

WM KIT HVL 4.022 2,2 240 170 258 290 5,6 8,2

WM KIT HVL 4.030 3 240 170 258 290 5,6 8,2

WM KIT HVL 4.040 4 240 170 258 290 5,6 8,2

WM KIT HVL 4.055 5,5 240 175 258 290 10,5 8,2

WM KIT HVL 4.075 7,5 240 175 258 290 10,5 8,2

WM KIT HVL 4.110 11 320 175 288 305 10,5 5,4

WM KIT HVL 4.150 15 400 200 325 365 15,6 11,6

WM KIT HVL 4.185 18,5 400 200 325 365 15,6 11,6

WM KIT HVL 4.220 22 400 200 325 365 15,6 11,6

WM-KIT_HVL_models-EN_b_td

WEIGHT (kg)

3~ 230V

3~ 400V

A

B

A

B

C

A

B

C

WM KIT

TIPE

HVL

SIZE

DIMENSIONS (mm)kW

WM KIT

POWER SUPPLY

1~ 230V

As an option a HYDROVAR wall mounting kit is also available. This is used where mounting on the pump unit is impossible or where you would like the controls in another location. These are available for the new generation HYDROVAR HVL 2.015-4.220 (22 kW). The speed of the cooling fan modulates with the HYDROVAR usage which optimizes energy consumption and also reduces noise.

Page 101: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

101

ACCESSORIES

Page 102: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

102

SPACER COUPLING DIMENSIONS

3.23.2

part 1 part 4

MATERIAL:GREY CAST IRONWITH FLEXIBLE ELEMENTS MADE OF SYNTHETIC RUBBER 80 ShA COUP-B_EN_A_DD

d1

d2

l1sl2

u2

u1

t2 t1

da

+0.2 0

+0.2 0

Js9

Js9

H7 H7

Coup-B_en_a_td

Page 103: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

103

FLEXIBLE COUPLING DIMENSIONS

COUP-RUPEX_EN_A_DD

part 1 part 2+0.2 0

+0.2 0

Js9

Js9

H7 H7

MATERIAL:RWN: GREY CAST IRONRWS: CAST STEELWITH FLEXIBLE ELEMENTS MADEOF SYNTHETIC RUBBER 80 ShA

3.23.2

d1

d2

l1sl2

u2

u1

t2 t1

da

Coup-RUPEX_en_a_td

Page 104: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

104

SENSOR CONNECTOR AND SENSORS FOR PUMP-MONITORING AND DIAGNOSTIC SYSTEMS

horizontal

vertical

Detail X Detail Y

MP-sensor_a_td

Page 105: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

105

REPORTS ANDDECLARATIONS

Page 106: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

106

REPORTS AND DECLARATIONS

i) Test reports

a) Factory Test Report (not available for all pump types; contact Customer Service in advance) - Test report compiled at the end of the assembly line, including flow-head performance test (ISO9906:2012)andtightnesstest.

b) Audit Test Report - Test report for electric pumps compiled in the test room, comprising flow-head-pump input-pump efficiency performancetest(ISO9906:2012)

c) NPSH Test Report - Testreportforelectricpumpscompiledinthetestroom,comprisingflow-NPSHperformancetest (ISO9906:2012)

d) Noise Test Report -Reportindicatingsoundpressureandpowermeasurements(ENISO20361,ENISO11203,ENISO4871) e) Vibration Test Report -Reportindicatingvibrationmeasurements(ISO10816-1)

ii) Declaration of product conformity with the technical requirements indicated in the order

a) EN 10204:2004 - type 2.1 - does not include test results on supplied or similar products.

b) EN 10204:2004 - type 2.2 - includes test results (materials certificates) on similar products.

iii) Issue of a further EC Declaration of Conformity, - in addition to the one accompanying the product, it comprises references to European law and the main

technicalstandards(e.g.:MD2006/42/EC,EMCD2004/108/EC,ErP2009/125/EC). N.B.: if the request is made after receipt of the product, communicate the code (name) and serial number (date

+ progressive number).

iv) Manufacturer’s declaration of conformity - relative to one of more types of products without indicating specific codes and serial numbers.

v) Other certificates and/or documentation on request - subject to availability or feasibility.

vi) Duplication of certificates and/or documentation on request - subject to availability or feasibility.

Page 107: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

107

TECHNICALAPPENDIX

Page 108: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

108

e-MP SERIESFORCES AND MOMENTS AT PUMP FLANGES

TECHNICAL APPENDIX

Page 109: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

109

e-MP SERIESFORCES AND MOMENTS AT PUMP FLANGES

TECHNICAL APPENDIX

Page 110: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

110

The minimum operating values that can be reached at the pump suction end are limited by the onset of cavitation.

Cavitation is the formation of vapour-filled cavities within liquids where the pressure is locally reduced to a critical value, or where the local pressure is equal to, or just below the vapour pressure of the liquid.

The vapour-filled cavities flow with the current andwhen they reach a higher pressure area the vapourcontained in the cavities condenses. The cavities collide,generating pressure waves that are transmitted to thewalls. These, being subjected to stress cycles, graduallybecome deformed and yield due to fatigue. Thisphenomenon, characterized by a metallic noiseproduced by the hammering on the pipe walls, is calledincipient cavitation.

The damage caused by cavitation may be magnified byelectrochemical corrosion and a local rise intemperature due to the plastic deformation of thewalls. The materials that offer the highest resistance toheat and corrosion are alloy steels, especially austeniticsteel. The conditions that trigger cavitation may beassessed by calculating the total net suction head,referred to in technical literature with the acronymNPSH(NetPositiveSuctionHead).

TheNPSHrepresentsthetotalenergy(expressedinm.)of the liquid measured at suction under conditions ofincipient cavitation, excluding the vapour pressure(expressed in m.) that the liquid has at the pump inlet.

To find the static height hz at which to install themachine under safe conditions, the following formulamust be verified:

hp + hz ≥ (NPSHr + 0.5) + hf + hpv

where:hp is the absolute pressure applied to the free liquid surface in the suction tank, expressed in m. of liquid; hp is the quotient between the barometric pressure and the specific weight of the liquid.hz is the suction lift between the pump axis and the free liquid surface in the suction tank, expressed in m.; hz is negative when the liquid level is lower than the pump axis.hf is the flow resistance in the suction line and its accessories, such as: fittings, foot valve, gate valve, elbows, etc.hpv is the vapour pressure of the liquid at the operating temperature, expressed in m. of liquid. hpv is the quotient between the Pv vapour pressure and the liquid’s specific weight.0,5 is the safety factor.

The maximum possible suction head for installationdepends on the value of the atmospheric pressure(i.e. the elevation above sea level at which the pumpis installed) and the temperature of the liquid.

To help the user, with reference to water temperature(4°C)andtotheelevationabovesealevel,thefollowing tables show the drop in hydraulic pressurehead in relation to the elevation above sea level, andthe suction loss in relation to temperature.

Friction loss is shown in the tables Flow Resistance ofthis catalogue. To reduce it to a minimum, especiallyin cases of high suction head (over 4-5 m.) or withinthe operating limits with high flow rates, werecommend using a suction line having a largerdiameter than that of the pump’s suction port.It is always a good idea to position the pump as closeas possible to the liquid to be pumped.

Make the following calculation:

Liquid:waterat~15°Cγ = 1 kg/dm3

Flow rate required: 25 m3/hHead for required delivery: 70 m.Suctionlift:3,5m.Theselectionisan33SV3G075TpumpwhoseNPSHrequired value is, at 25 m3/h, of 2 m.

Forwaterat15°C

hp = Pa / γ=10,33m,hpv=Pv/γ = 0,174m (0,01701 bar)

The Hf flow resistance in the suction line with footvalves is ~ 1,2 m.By substituting the parameters in formula with thenumeric values above, we have:

10,33+(-3,5)≥(2+0,5)+1,2+0,17

fromwhichwehave:6,8>3,9

The relation is therefore verified.

water temperature (°C)2040608090110120

Suction loss (m) 0,2 0,7 2,0 5,0 7,4 15,4 21,5

Elevation above sea level (m)50010001500200025003000

Suction loss (m)0,551,11,652,22,753,3

NPSH

1

1

TECHNICAL APPENDIX

Page 111: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

111

VAPOUR PRESSUREVAPOUR PRESSURE ps AND ρ DENSITY OF wATER TABLETENSIONE DI VAPORETABELLA TENSIONE DI VAPORE ps E DENSITA' ρ DELL'ACQUA

t T ps ρ t T ps ρ t T ps ρ

°C K bar kg/dm3 °C K bar kg/dm3 °C K bar kg/dm3

0 273,15 0,00611 0,9998 55 328,15 0,15741 0,9857 120 393,15 1,9854 0,94291 274,15 0,00657 0,9999 56 329,15 0,16511 0,9852 122 395,15 2,1145 0,94122 275,15 0,00706 0,9999 57 330,15 0,17313 0,9846 124 397,15 2,2504 0,93963 276,15 0,00758 0,9999 58 331,15 0,18147 0,9842 126 399,15 2,3933 0,93794 277,15 0,00813 1,0000 59 332,15 0,19016 0,9837 128 401,15 2,5435 0,93625 278,15 0,00872 1,0000 60 333,15 0,1992 0,9832 130 403,15 2,7013 0,93466 279,15 0,00935 1,0000 61 334,15 0,2086 0,9826 132 405,15 2,867 0,93287 280,15 0,01001 0,9999 62 335,15 0,2184 0,9821 134 407,15 3,041 0,93118 281,15 0,01072 0,9999 63 336,15 0,2286 0,9816 136 409,15 3,223 0,92949 282,15 0,01147 0,9998 64 337,15 0,2391 0,9811 138 411,15 3,414 0,927610 283,15 0,01227 0,9997 65 338,15 0,2501 0,9805 140 413,15 3,614 0,925811 284,15 0,01312 0,9997 66 339,15 0,2615 0,9799 145 418,15 4,155 0,921412 285,15 0,01401 0,9996 67 340,15 0,2733 0,9793 155 428,15 5,433 0,912113 286,15 0,01497 0,9994 68 341,15 0,2856 0,9788 160 433,15 6,181 0,907314 287,15 0,01597 0,9993 69 342,15 0,2984 0,9782 165 438,15 7,008 0,902415 288,15 0,01704 0,9992 70 343,15 0,3116 0,9777 170 433,15 7,920 0,897316 289,15 0,01817 0,9990 71 344,15 0,3253 0,9770 175 448,15 8,924 0,892117 290,15 0,01936 0,9988 72 345,15 0,3396 0,9765 180 453,15 10,027 0,886918 291,15 0,02062 0,9987 73 346,15 0,3543 0,9760 185 458,15 11,233 0,881519 292,15 0,02196 0,9985 74 347,15 0,3696 0,9753 190 463,15 12,551 0,876020 293,15 0,02337 0,9983 75 348,15 0,3855 0,9748 195 468,15 13,987 0,870421 294,15 0,24850 0,9981 76 349,15 0,4019 0,9741 200 473,15 15,550 0,864722 295,15 0,02642 0,9978 77 350,15 0,4189 0,9735 205 478,15 17,243 0,858823 296,15 0,02808 0,9976 78 351,15 0,4365 0,9729 210 483,15 19,077 0,852824 297,15 0,02982 0,9974 79 352,15 0,4547 0,9723 215 488,15 21,060 0,846725 298,15 0,03166 0,9971 80 353,15 0,4736 0,9716 220 493,15 23,198 0,840326 299,15 0,03360 0,9968 81 354,15 0,4931 0,9710 225 498,15 25,501 0,833927 300,15 0,03564 0,9966 82 355,15 0,5133 0,9704 230 503,15 27,976 0,827328 301,15 0,03778 0,9963 83 356,15 0,5342 0,9697 235 508,15 30,632 0,820529 302,15 0,04004 0,9960 84 357,15 0,5557 0,9691 240 513,15 33,478 0,813630 303,15 0,04241 0,9957 85 358,15 0,5780 0,9684 245 518,15 36,523 0,806531 304,15 0,04491 0,9954 86 359,15 0,6011 0,9678 250 523,15 39,776 0,799232 305,15 0,04753 0,9951 87 360,15 0,6249 0,9671 255 528,15 43,246 0,791633 306,15 0,05029 0,9947 88 361,15 0,6495 0,9665 260 533,15 46,943 0,783934 307,15 0,05318 0,9944 89 362,15 0,6749 0,9658 265 538,15 50,877 0,775935 308,15 0,05622 0,9940 90 363,15 0,7011 0,9652 270 543,15 55,058 0,767836 309,15 0,05940 0,9937 91 364,15 0,7281 0,9644 275 548,15 59,496 0,759337 310,15 0,06274 0,9933 92 365,15 0,7561 0,9638 280 553,15 64,202 0,750538 311,15 0,06624 0,9930 93 366,15 0,7849 0,9630 285 558,15 69,186 0,741539 312,15 0,06991 0,9927 94 367,15 0,8146 0,9624 290 563,15 74,461 0,732140 313,15 0,07375 0,9923 95 368,15 0,8453 0,9616 295 568,15 80,037 0,722341 314,15 0,07777 0,9919 96 369,15 0,8769 0,9610 300 573,15 85,927 0,712242 315,15 0,08198 0,9915 97 370,15 0,9094 0,9602 305 578,15 92,144 0,701743 316,15 0,09639 0,9911 98 371,15 0,9430 0,9596 310 583,15 98,70 0,690644 317,15 0,09100 0,9907 99 372,15 0,9776 0,9586 315 588,15 105,61 0,679145 318,15 0,09582 0,9902 100 373,15 1,0133 0,9581 320 593,15 112,89 0,666946 319,15 0,10086 0,9898 102 375,15 1,0878 0,9567 325 598,15 120,56 0,654147 320,15 0,10612 0,9894 104 377,15 1,1668 0,9552 330 603,15 128,63 0,640448 321,15 0,11162 0,9889 106 379,15 1,2504 0,9537 340 613,15 146,05 0,610249 322,15 0,11736 0,9884 108 381,15 1,3390 0,9522 350 623,15 165,35 0,574350 323,15 0,12335 0,9880 110 383,15 1,4327 0,9507 360 633,15 186,75 0,527551 324,15 0,12961 0,9876 112 385,15 1,5316 0,9491 370 643,15 210,54 0,451852 325,15 0,13613 0,9871 114 387,15 1,6362 0,9476 374,15 647,30 221,20 0,315453 326,15 0,14293 0,9862 116 389,15 1,7465 0,946054 327,15 0,15002 0,9862 118 391,15 1,8628 0,9445

G-at_npsh_b_sc

TECHNICAL APPENDIX

Page 112: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

112

TABLE OF FLOw RESISTANCE IN 100 m OF STRAIGHT CAST IRON PIPELINE (HAZEN-wILLIAMS FORMULA C=100)

m3/h l/min 15 20 25 32 40 50 65 80 100 125 150 175 200 250 300 350 4001/2" 3/4" 1" 1 1/4" 1 1/2" 2 2 1/2" 3" 4" 5" 6" 7" 8" 10" 12" 14" 16"

v 0,94 0,53 0,34 0,21 0,13 hr 16 3,94 1,33 0,40 0,13 The hr values must be multiplied by:v 1,42 0,80 0,51 0,31 0,20 0,71 for galvanized or painted steel pipes hr 33,9 8,35 2,82 0,85 0,29 0,54 for stainless steel or copper pipes v 1,89 1,06 0,68 0,41 0,27 0,17 0,47 for PVC or PE pipes hr 57,7 14,21 4,79 1,44 0,49 0,16 v 2,36 1,33 0,85 0,52 0,33 0,21hr 87,2 21,5 7,24 2,18 0,73 0,25v 2,83 1,59 1,02 0,62 0,40 0,25hr 122 30,1 10,1 3,05 1,03 0,35v 3,30 1,86 1,19 0,73 0,46 0,30hr 162 40,0 13,5 4,06 1,37 0,46v 2,12 1,36 0,83 0,53 0,34 0,20hr 51,2 17,3 5,19 1,75 0,59 0,16v 2,65 1,70 1,04 0,66 0,42 0,25hr 77,4 26,1 7,85 2,65 0,89 0,25v 3,18 2,04 1,24 0,80 0,51 0,30hr 108 36,6 11,0 3,71 1,25 0,35v 3,72 2,38 1,45 0,93 0,59 0,35hr 144 48,7 14,6 4,93 1,66 0,46v 4,25 2,72 1,66 1,06 0,68 0,40hr 185 62,3 18,7 6,32 2,13 0,59v 3,06 1,87 1,19 0,76 0,45 0,30hr 77,5 23,3 7,85 2,65 0,74 0,27v 3,40 2,07 1,33 0,85 0,50 0,33hr 94,1 28,3 9,54 3,22 0,90 0,33v 4,25 2,59 1,66 1,06 0,63 0,41hr 142 42,8 14,4 4,86 1,36 0,49v 3,11 1,99 1,27 0,75 0,50 0,32hr 59,9 20,2 6,82 1,90 0,69 0,23v 3,63 2,32 1,49 0,88 0,58 0,37hr 79,7 26,9 9,07 2,53 0,92 0,31v 4,15 2,65 1,70 1,01 0,66 0,42hr 102 34,4 11,6 3,23 1,18 0,40v 5,18 3,32 2,12 1,26 0,83 0,53 0,34hr 154 52,0 17,5 4,89 1,78 0,60 0,20v 3,98 2,55 1,51 1,00 0,64 0,41hr 72,8 24,6 6,85 2,49 0,84 0,28v 5,31 3,40 2,01 1,33 0,85 0,54 0,38hr 124 41,8 11,66 4,24 1,43 0,48 0,20v 6,63 4,25 2,51 1,66 1,06 0,68 0,47hr 187 63,2 17,6 6,41 2,16 0,73 0,30v 5,10 3,02 1,99 1,27 0,82 0,57 0,42hr 88,6 24,7 8,98 3,03 1,02 0,42 0,20v 5,94 3,52 2,32 1,49 0,95 0,66 0,49hr 118 32,8 11,9 4,03 1,36 0,56 0,26v 6,79 4,02 2,65 1,70 1,09 0,75 0,55hr 151 42,0 15,3 5,16 1,74 0,72 0,34v 7,64 4,52 2,99 1,91 1,22 0,85 0,62hr 188 52,3 19,0 6,41 2,16 0,89 0,42v 5,03 3,32 2,12 1,36 0,94 0,69 0,53hr 63,5 23,1 7,79 2,63 1,08 0,51 0,27v 6,28 4,15 2,65 1,70 1,18 0,87 0,66hr 96,0 34,9 11,8 3,97 1,63 0,77 0,40v 7,54 4,98 3,18 2,04 1,42 1,04 0,80hr 134 48,9 16,5 5,57 2,29 1,08 0,56v 8,79 5,81 3,72 2,38 1,65 1,21 0,93hr 179 65,1 21,9 7,40 3,05 1,44 0,75v 6,63 4,25 2,72 1,89 1,39 1,06 0,68hr 83,3 28,1 9,48 3,90 1,84 0,96 0,32v 8,29 5,31 3,40 2,36 1,73 1,33 0,85hr 126 42,5 14,3 5,89 2,78 1,45 0,49v 6,37 4,08 2,83 2,08 1,59 1,02 0,71hr 59,5 20,1 8,26 3,90 2,03 0,69 0,28v 7,43 4,76 3,30 2,43 1,86 1,19 0,83hr 79,1 26,7 11,0 5,18 2,71 0,91 0,38v 8,49 5,44 3,77 2,77 2,12 1,36 0,94hr 101 34,2 14,1 6,64 3,46 1,17 0,48v 6,79 4,72 3,47 2,65 1,70 1,18hr 51,6 21,2 10,0 5,23 1,77 0,73v 8,15 5,66 4,16 3,18 2,04 1,42hr 72,3 29,8 14,1 7,33 2,47 1,02v 6,61 4,85 3,72 2,38 1,65 1,21hr 39,6 18,7 9,75 3,29 1,35 0,64v 7,55 5,55 4,25 2,72 1,89 1,39hr 50,7 23,9 12,49 4,21 1,73 0,82v 8,49 6,24 4,78 3,06 2,12 1,56 1,19hr 63,0 29,8 15,5 5,24 2,16 1,02 0,53v 6,93 5,31 3,40 2,36 1,73 1,33hr 36,2 18,9 6,36 2,62 1,24 0,65

G-at-pct-en_a_thhr = flow resistance for 100 m of straight pipeline (m)V = water speed (m/s)

TABELLA PERDITE DI CARICO PER 100 m TUBAZIONE DIRITTA IN GHISA (FORMULA HAZEN-WILLIAMS C=100)

105 1750

42 700

54 900

9

7,5 125

FLOW RATE NOMINAL DIAMETER in mm and inches

40

3,6 60

25

2,4

0,9 15

0,6

6 100

5,4

1,2 20

1,8 30

2,1 35

1,5

10

30

4,2 70

3 50

150

12 200

4,8 80

400

90

175

48

36

24

15

10,5

18 300

250

100060

90

75 1250

500

800

600

180 3000

2000120

150 2500

1500

210 3500

360 6000

240 4000

300 5000

420 7000

600 10000

8000480

540 9000

TECHNICAL APPENDIX

Page 113: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

113

FLOw RESISTANCETABLE OF FLOw RESISTANCE IN BENDS, VALVES AND GATES

The flow resistance is calculated using the equivalent pipeline length method according to the table below:

The table is valid for the Hazen Williams coefficient C=100 (cast iron pipework); for steel pipework, multiply the values by 1,41; forstainlesssteel,copperandcoatedcastironpipework,multiplythevaluesby1,85;When the equivalent pipeline length has been determined, the flow resistance is obtained from the table of flow resistance.The values given are guideline values which are bound to vary slightly according to the model, especially for gate valves and non-return valves, for which it is a good idea to check the values supplied by manufacturers.

TABELLA LUNGHEZZA DI TUBAZIONE EQUIVALENTE

ACCESSORY

TYPE 25 32 40 50 65 80 100 125 150 200 250 300

45° bend 0,2 0,2 0,4 0,4 0,6 0,6 0,9 1,1 1,5 1,9 2,4 2,890° bend 0,4 0,6 0,9 1,1 1,3 1,5 2,1 2,6 3,0 3,9 4,7 5,890° smooth bend 0,4 0,4 0,4 0,6 0,9 1,1 1,3 1,7 1,9 2,8 3,4 3,9Union tee or cross 1,1 1,3 1,7 2,1 2,6 3,2 4,3 5,3 6,4 7,5 10,7 12,8Gate - - - 0,2 0,2 0,2 0,4 0,4 0,6 0,9 1,1 1,3Non return valve 1,1 1,5 1,9 2,4 3,0 3,4 4,7 5,9 7,4 9,6 11,8 13,9

G-a-pcv-en_a_th

DN

Equivalent pipeline length (m)

TECHNICAL APPENDIX

Page 114: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

114

Litres Cubic metres Cubic feet Cubic feet Imperial gallon U.S. gallon

per minute per hour per hour per minute per minute per minute

l/min m3/h ft3/h ft3/min Imp. gal/min US gal/min1,0000 0,0600 2,1189 0,0353 0,2200 0,2642

16,6667 1,0000 35,3147 0,5886 3,6662 4,40290,4719 0,0283 1,0000 0,0167 0,1038 0,1247

28,3168 1,6990 60,0000 1,0000 6,2288 7,48054,5461 0,2728 9,6326 0,1605 1,0000 1,20093,7854 0,2271 8,0208 0,1337 0,8327 1,0000

Newton per kilo Pascal bar Pound force per Metre Millimetre ofsquare metre square inch of water mercury

N/m2 kPa bar psi m H2O mm Hg1,0000 0,0010 1 x 10-5 1,45 x 10-4 1,02 x 10-4 0,0075

1 000,0000 1,0000 0,0100 0,1450 0,1020 7,50061 x 105 100,0000 1,0000 14,5038 10,1972 750,0638

6 894,7570 6,8948 0,0689 1,0000 0,7031 51,7151 9 806,6500 9,8067 0,0981 1,4223 1,0000 73,5561

133,3220 0,1333 0,0013 0,0193 0,0136 1,0000

Millimetre Centimetre Metre Inch Foot Yard

mm cm m in ft yd

1,0000 0,1000 0,0010 0,0394 0,0033 0,0011

10,0000 1,0000 0,0100 0,3937 0,0328 0,0109 1 000,0000 100,0000 1,0000 39,3701 3,2808 1,0936

25,4000 2,5400 0,0254 1,0000 0,0833 0,0278304,8000 30,4800 0,3048 12,0000 1,0000 0,3333914,4000 91,4400 0,9144 36,0000 3,0000 1,0000

Cubic metre Litre Millilitre Imperial gallon U.S. gallon Cubic foot

m3 L ml imp. gal. US gal. ft3

1,0000 1 000,0000 1 x 106 219,9694 264,1720 35,3147

0,0010 1,0000 1 000,0000 0,2200 0,2642 0,03531 x 10-6 0,0010 1,0000 2,2 x 10-4 2,642 x 10-4 3,53 x 10-5

0,0045 4,5461 4 546,0870 1,0000 1,2009 0,16050,0038 3,7854 3 785,4120 0,8327 1,0000 0,13370,0283 28,3168 28 316,8466 6,2288 7,4805 1,0000

Water Kelvin Celsius FahrenheitK °C °F

icing 273,1500 0,0000 32,0000boiling 373,1500 100,0000 212,0000

G-at_pp-en_b_sc

°F = °C × 95 + 32

°C = (°F – 32) × 59

VOLUMETRIC CAPACITY

PRESSURE AND HEAD

LENGTH

VOLUME

TECHNICAL APPENDIX

TEMPERATURE

Page 115: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

115 TECHNICAL APPENDIX

FURTHER PRODUCT SELECTIONAND DOCUMENTATIONXylectTM

XylectTM is pump solution selection software with an extensive online database of product information across the entire Lowara range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories.

The possibility to search by applications and the detailed information output given makes it easy to make the optimal selection without having detailed knowledge about the Lowara products.

The search can be made by:

• Application

• Product type

• Duty point

XylectTM gives a detailed output:

• List with search results

• Performance curves (flow, head, power, efficiency,NPSH)

• Motor data

• Dimensional drawings

• Options

• Data sheet printouts

• Document downloads incl dxf filesThe search by application guides users not familiar with the product range to the right choice.

Page 116: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

116TECHNICAL APPENDIX

FURTHER PRODUCT SELECTIONAND DOCUMENTATIONXylectTM

The detailed output makes it easy to select the optimal pump from the given alternatives.

The best way to work with XylectTM is to create a personal account. This makes it possible to:

• Set own standard units

• Create and save projects

• Share projects with other XylectTM users

Every user has a My Xylect space, where all projects are saved.

Dimensional drawings appear on the screen and can be downloaded in dxf format.

Page 117: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

117

Page 118: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

118

Page 119: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all
Page 120: Lowara-MP-MPA-MPR-MPD-MPV-high-pressure-multistage … · HIGH PRESSURE MULTISTAGE PUMPS ACCORDING TO ISO 5199 ... sprinkler systems, washing/cleaning systems, ... Sea water in all

Xylem Water Solutions Italia Srl reserves the right to make modification without prior notice.Lowara, Xylem are trademarks of Xylem Inc. or one of its subsidiaries© 2017 Xylem, Inc.

For information and technical support

1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company.

We’re a global team unified in a common purpose: creating advanced technology solutions to the world’s wa-ter challenges. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. Our products and services move, treat, analyze, monitor and return water to the environment, in public utility, industrial, residential and commercial building services, and agricultural settings. With its October 2016 acquisition of Sensus, Xylem added smart metering, network technologies and advanced data analytics for water, gas and electric utilities to its portfolio of solutions. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combina-tion of leading product brands and applications expertise with a strong focus on developing comprehensive, sustainable solutions.

Xylem |’zīl m|e

[email protected] Tel. +31-152-610-900www.lenntech.com Fax. [email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289

Lenntech

For more information on how Xylem can help you, go to www.lenntech.com.