Distributed Node BProduct Description
All Rights Reserved © Alcatel-Lucent 2006, #####2 | Presentation Title | Month 2006
Digital Unit: Alcatel-Lucent 9396 d2U
Small, high density: only 2U high, fits standard 19” racks.
Options for wall and pole mount; outdoor enclosure available
Can be mounted in other base stations facilities space
High CE capacity: 3x UCU-III (same as used in AT&T’s Macrocells) = 384 CEs
3x CPRI fibre links, up to 15km fibre length
T1 backhaul, h/w ready for Ethernet
Designed to stack & interconnect for growth
d2U overview
All Rights Reserved © Alcatel-Lucent 2006, #####3 | Presentation Title | Month 2006
9396 d2U Design Overview
4 T1/E1 (internal)
RMT Eth 1
CPRI 1-3
Switch ON/OFF 1-4 (3 CPRI + 1 SERDES)
CTU-II RF Ports (GPS, 15MHz, TPUL, TCLK)
T1/E1 (1-8)
User Alarms (4+4)
RMT Eth 2
LIU Eth 1
Ground Point
DC Power
OCM-II Maintenance (Ethernet)
RS485 (RET) Cab. Alarms
100BaseSX
SERDES BBU Growth
Shelf ID switch
ESD Jack
Removable UCU-III
d2U overview
All Rights Reserved © Alcatel-Lucent 2006, #####4 | Presentation Title | Month 2006
9396 d2U Physical Design
d2U overview
All Rights Reserved © Alcatel-Lucent 2006, #####5 | Presentation Title | Month 2006
9396 d2U Wall Mounting
Indoor Vertical Mounting Options
Pole Mounting by re-use of wall mount assets plus pole strap
Security Locking ScrewsAnd Cable OrganizerAdded at AT&T request
d2U overview
All Rights Reserved © Alcatel-Lucent 2006, #####6 | Presentation Title | Month 2006
9396 d2U outdoor enclosure - Main characteristics
DESCRIPTIONOutdoor dNodeB 2U:
• IP55• less than 30kg (equipped)• -33°C +50°C• Wall and Pole mounting kit• -48V DC Power supply initially• d2U equipped with up to 3 CE
cards• Option: External alarms kit and
PCM Lightning protection kit (2 * ½ 19”) in the user space.
VALUEThe d2U Outdoor is a very compact
digital NodeB designed to be installed in Outdoor environment on a pole or on a wall.
8 ins
24 ins
19 ins
d2U
1U User Space
d2U overview
All Rights Reserved © Alcatel-Lucent 2006, #####7 | Presentation Title | Month 2006
9396 d2U Key Environmental Parameters
Competitive Environmental Design leading to lower TCO
Indoor Outdoor
Size (w x h x d) 17.3 x 15.7 x 3.5 in 24.6 x 18.9 x 7.9 in
Weight 25 lb 60 lb
Temperature 23 to 122F;
Option for +65C (149F)-40 to 131F;
Cold start -30C
Humidity 5% to 85% 15% to 100%
Cooling/Noise <45dBA BBU Fresh air forced cooling,
<49dBA
Power Supply -48VDC
100W typical (1 x UCU)
-48V DC
Ingress
Protection
EN 60529 IP55.
GR-487-CORE Wind Driven
Rain
d2U overview
All Rights Reserved © Alcatel-Lucent 2006, #####8 | Presentation Title | Month 2006
Additional alarms on 9396 d2U: u4287
32 Alarms (8+24)• Lab delivery Sep 08
• New expansion card• Proven connector• Field installable
8 user alarms
Additional 24 user alarms
d2U overview
All Rights Reserved © Alcatel-Lucent 2006, #####9 | Presentation Title | Month 2006
Capacity growth on d2U
Indoor
Alarms:
Mount the alarm expansion module in the d2U slot; connect internal ribbon cable.
Connect from the expansion module to the alarms with multiple RJ-45 terminated cables
T1s 5-8:
Mount the InPM (0.5U) in the rack next to d2U
Connect from d2U to InPM (micro dsub to micro dsub – all front panel)
Connect from InPM to the incoming T1s (RJ45s)
Outdoor
Alarms:
Mount the alarm expansion module in the d2U slot.
Mount the AnPM (0.5U) in the OD housing's 1U empty space.
Cable from the alarm expansion module to the AnPM (RJ45 to RJ45)
Cable from AnPM to external alarms (RJ45s)
T1s 5-8:
Protection is already included in the d2U OD
Cable from d2U OD to incoming T1s (RJ45s)
AnPM (0.5U H):
InPM (0.5U H):
d2U overview
All Rights Reserved © Alcatel-Lucent 2006, #####10 | Presentation Title | Month 2006
Distributed capacity growth
Config 1: 1C3S Single Band (Full capacity)
(C1, S1)
(C1, S2)
Up to 8 T1
(C1, S3)
BBU1
Config 2: 2C3S Dual Band (limited CE capacity)
(C1-2, S1)
(C1-2, S2)
Up to 8 T1
(C1-2, S3)
BBU1
(C1-2, S1)
(C1-2, S2)8 T1
LIU Ethernet
(C1-2, S3)
IQ SERDES
Config 3: 2C3S full CE capacity, BH sharing, no CE pooling
BBU1
BBU2
New SW Add HW New SW + Add HW
1: Daisy-Chaining(u4262, r5.1)
3: Stacking, phase 1(74715, UA07)
2: UCU pooling(74978, UA06)
d2U evolution
All Rights Reserved © Alcatel-Lucent 2006, #####11 | Presentation Title | Month 2006
UCU Pooling for Dual Band (UA6.0)
Common Chn f1s1
Common Chn f1s2Common Chn f1s3 Common Chn
f2s1,2,3
max. 14.4 Mbps/cell max. 14.4 Mbps/cell max. 9.6 Mbps/cell
R99 resources for both frequencies are pooled across all available UCU boardsHSPA resources are restricted so one UCU board can serve only one frequency
HSPA f1s1
HSPA f1s2
HSPA f1s3
UnusedHSPA
f2s1,2,3
Common Chn f1s1
Common Chn f1s2Common Chn f1s3 Common Chn f2s1
max. 14.4 Mbps/cell max. 14.4 Mbps/cell max. 14.4 Mbps/cell
Common Chn f2s2Common Chn f2s3
HSPA f1s1
HSPA f1s2
HSPA f1s3
HSPA f2s3
HSPA f2s1
HSPA f2s2
TODAY
WITH
POOLING
Assignment of HS sector-carriers to UCUs is determined by current UCU loadand not by engineering parameters
d2U evolution
All Rights Reserved © Alcatel-Lucent 2006, #####12 | Presentation Title | Month 2006
Remote Radio Head: Alcatel-Lucent 9341 RRH40 Alcatel-Lucent’s 40W solution
Multiple frequencies being introduced 850, 1900MHz (+ other freqs in ALU portfolio)
Multi-carrier ready (2 or 3C) Outdoor environment: -40C to +55C(*)
230W typical power consumption Silent operation (no fans)
Small: 25 litres(*) Options for wall and pole mount Connector box – allows pre-mounting
CPRI fibre link, up to 15km fibre length HW support for star & daisy chain connection
Flexible RF configurations Rx-AIT, antenna sharing, Rx diversity (1 duplex, 1 simplex)
Support for TMAs Conventional current window operation at launch AISG TMA and RET to follow
-48V DC power supply
9341 RRH family
RRH overview
All Rights Reserved © Alcatel-Lucent 2006, #####13 | Presentation Title | Month 2006
Remote Radio Head: Alcatel-Lucent 9341 RRH40 NAR portfolio
Operational Band Operationa
l
Bandwidth
Size
Cellular
850MHz
Band V
Tx:869-894MHz
Rx: 824-849MHz
10MHz
2 carriers
9.8 x 22.4 x 8.3
inches
53 lb
PCS
1900M
Hz
Band II
Tx:1930-1990
Rx: 1850-1910
Full band
15MHz
3 carriers
9.8 x 18.1 x 8.3
inches
44 lb
1990MHz1930
1990MHz1930MHz15MHz bandwidth anywhere in the band
15MHz b/w
1940 1950 1960 1970 1980
890MHz880MHz870MHz
894MHz869MHz10MHz bandwidth anywhere in the band
10MHz b/w
RRH overview
All Rights Reserved © Alcatel-Lucent 2006, #####14 | Presentation Title | Month 2006
RRH characteristics
9341 RRH 40W portfolio
Frequency-specific
characteristics
See previous viewgraph
Fibre capacity 2 CPRI ports per RRH
1 port populated; 1 slot available for growth
614Mbps: now; 1.2Gbps: future
Daisy-chain: Release 5.1
RF 40W RF; 2 or 3 carrier b/w
Ancillary functions Duplex/ Simplex operation
Antenna sharing
TTLNA support (conventional current window: now; AISG:
future)
RET (hardware-ready; software future & tbc)
Weatherization NEBS Zone 4, IP55, UL50
Temperature range Outdoor: -40C to +55C(*)
(* Operation at 55C requires an optional solar parasol)
Power consumption -48V supply
230 W Typical
Acoustic noise Silent
RRH overview
All Rights Reserved © Alcatel-Lucent 2006, #####15 | Presentation Title | Month 2006
Weatherproof mounting system & connection box for RRH
Initial installation of mount and cables:
1 Fix mounting bracket
2 Add connection box
3 Install cables &/ conduit
4 Re-seal connection box
5 Leave site
Later installation of RRH:
1 Open connection box
2 Mount RRH on bracket
3 Connect cables
4 Seal box to RRH
5 Commission system
Sealable weatherproof
cover
Mounting bracket
Connectionbox
2-pass installation supported:
RRH overview
All Rights Reserved © Alcatel-Lucent 2006, #####16 | Presentation Title | Month 2006
Installed Cable box
Optical InterfacePowerTMA/
RETUser Alarms
All connections are push fit
Power and TMA/RET
connectors pass through glands
RRH overview
All Rights Reserved © Alcatel-Lucent 2006, #####17 | Presentation Title | Month 2006
1900 and 850 Slim I/O Panel
Alarms(2x RJ45)
TTLNA(1x D9)
Power(2x stripped wire, up to 6 AWG)
Fibre daisy-chain
(SFP = 1x LC pair)
Fibre to d2U(SFP = 1x LC pair)
OCI port, Ethernet Blank port
RS232
RxAIT/ Simplex RF(2x QMA)
RRH overview
All Rights Reserved © Alcatel-Lucent 2006, #####18 | Presentation Title | Month 2006
Fibre connectivity & growth: 9396 d2U to RRH40-08/ 19
d2U RRH
Opt TRXOpt TRX
RRH
Opt TRX
Opt TRXWeatherproof
cable box
Field-terminatable LC connectors
Growth items in greyOutdoor housing
Weatherproof cable gland
Weatherproof cable gland
Tx @ 1310nm Tx @ 1310nm
Single mode fibre pair: 15km range
Daisy-chain fibre configurations supported:
d2
U
RRH
RRH
RRH
RRH
RRH
RRH d2
U
RRH
RRH
RRHRRH
RRH RRH
RRH overview
Max: 15km per ‘hop’, 35km total
All Rights Reserved © Alcatel-Lucent 2006, #####19 | Presentation Title | Month 2006
RRH antenna connectivity
RF switches configure simplex/ duplex; operation with Rx-AIT and antenna sharing.Switches are set by RMT management tool
Duplex operation Simplex operation Antenna Sharing
Diplexer
Fibre interfaceRadio
PALNA
Diplexer
Fibre interfaceRadio
PALNA LNALNA
Diplexer
Fibre interfaceRadio
PA LNALNA
Other BTSor RRH
Diplexer
Radio
PA LNALNA
CPRI
d2U
CPRI
d2U
CPRI
d2U
EAC EACAUXAUXEAC EACAUXAUX EAC EAC AUXAUX *
*Either port can be used. RF characteristics differ to allow use in different scenarios
Backhaul Backhaul Backhaul Backhaul
Baseband
RRH overview
Software support future: planned UA07
EAC EAC AUXAUX *
All Rights Reserved © Alcatel-Lucent 2006, #####20 | Presentation Title | Month 2006
TTLNA support
RRH
TMA TMA
TMA power through ‘Y’ cable.Current window alarms; settable dependent on TMAs used.
Bias-T
Bias-T
Single housing for dual TMA
Direct cable connection may be used instead of Bias-Ts, where appropriate
Dotted red lines are signal paths
Bias-T may be included in TMA
RRH overview
All Rights Reserved © Alcatel-Lucent 2006, #####21 | Presentation Title | Month 2006
RRH carrier growth
Deploy 1 RRH / 1 carrier configuration & grow to 2nd RF Carrier
2 Independent RX chain on each RRH (unique to Alcatel-Lucent RRH)
Add a 2nd RRH to the CPRI link
Where the 2nd RRH is same band
Single RRH asset for initial deployment for growthand for spares management
Separate RRH per carrier enhances availability
dNodeB
RRHF1
RRHF1
RRHF1
dNodeB
RRHF1
f1+f2
RRHF2
f1+f2
RRHF1
f1+f2
RRHF2
f1+f2
RRHF1
f1+f2
RRHF2
f1+f2
RRH overview
All Rights Reserved © Alcatel-Lucent 2006, #####22 | Presentation Title | Month 2006
RRH 60W
Maximising compatibility with prior versions
Common ancillary and mounting hardware
Minimizes ancillary hardware versions; makes future upgrade simpler
Target is to have same housing as current 40W versions
For both 850 & 1900 MHz
Changes:
Higher efficiency PA
Higher efficiency PSU
Improved radio board
Other improvements under review
RRH evolution
Documentation and Site Guidelines
All Rights Reserved © Alcatel-Lucent 2006, #####24 | Presentation Title | Month 2006
Distributed Node B Site Documents
401-382-030 Alcatel-Lucent 9341 Remote Radio Head (RRH) Site Preparation Guide
Rel. 5.0
401-382-031 Alcatel-Lucent 9341 Remote Radio Head Operation, Administration
and Maintenance Rel. 5.0
401-382-023 Alcatel-Lucent 9396 digital 2U Node B Site Preparation Guidelines Rel.
5.0
401-382-027 Alcatel-Lucent 9396 digital 2U Node B Operation, Administration and
Maintenance Rel. 5.0
All available from normal Alcatel-Lucent document library
All Rights Reserved © Alcatel-Lucent 2006, #####25 | Presentation Title | Month 2006
Installation Options
Base Band Unit (d2U) Indoor/Outdoor• Pole Mounted (with pole brackets or pole band mounting)• Wall Mounted (with wall brackets)• Rack mounted (Indoor BBU only)• Floor Stand • 15A (indoor), 20A (outdoor) Circuit Breaker Required• CEQ.30770 BBU Indoor (ID) Node B Configuration (w/o RRH)• CEQ.30771 BBU Outdoor (OD) Node B Configuration (w/o RRH)
Remote Radio Heads (RRH) Outdoor• Pole Mount
• Small poles (2” – 6”) – 1 RRH per mount• Large poles (6” – 15”) – 2 or 3 RRH per mount
• Wall Mount• Floor Stand • 15A Circuit Breaker Required• CEQ.30603 RRH 850 40W• CEQ.30608 RRH 1900 40W
Low profile mountsmall clearance to poleback-to-back mount
Standard mountlarger clearance to pole3x 120 degree mount
All Rights Reserved © Alcatel-Lucent 2006, #####26 | Presentation Title | Month 2006
BBU Indoor Installation
Ohio FOA Burnett RD. Site 2333
All Rights Reserved © Alcatel-Lucent 2006, #####27 | Presentation Title | Month 2006
RRH Outdoor Installation at Ground Level
Ohio FOA Burnett RD. site 2333
All Rights Reserved © Alcatel-Lucent 2006, #####28 | Presentation Title | Month 2006
BBU Indoor Installation
Columbus FOA Site 3164
All Rights Reserved © Alcatel-Lucent 2006, #####29 | Presentation Title | Month 2006
RRH Outdoor Installation at Ground Level
Columbus FOA Site 3164