ADDENDUM 1
PROJECT
FROM Nancy Chao
Learning Centre Renovation DATE May 9, 2019
PROJECT 16-117
ADDRESS 30 The Queensway - Barnicke Bldg PAGES 25
St. Joseph's Health Centre
The following changes, additions, deletions and clarifications are hereby made an integral part of the documents, including the drawings and specifications for the above project. Acknowledgment for receipt of this addendum shall be indicated on the Tender Proposal.
Architectural:1. New Item: Architectural drawing A100 - Demolition and Proposed Plans and RCPs. Replace in its entirety the previously issued drawing A100 - Demolition and Proposed Plans and RCPs, dated May 3, 2019 with the attached drawing.
2. New Item: Architectural drawing A401 - Interior Elevations (1 page).Replace in its entirety the previously issued drawing A401 - Interior Elevations, dated May 3, 2019 with the attached drawing.
3. New Item: Refer to the attached A100 - Demolition and Proposed Plans and RCPs (1 page). GC to provide a separate price for the following scope of work for Auditorium A & B:
i. Refer to specification section 09 51 13 Acoustical Panel ceilings -2.2. Materials: Change acoustic ceiling tile from ACT1 to ACT2 type.
ii. Refer to Electrical & Mechanical addenda #1 for corresponding changes.
4. New Item: Add attached specification section 09 72 10 Dry erase Projectable Wallcovering annotated as "WB" in the drawings (4 pages). Refer to the attached drawing A401. Replace all "WBP" with "WB" within the project area.
5. New Item: Refer to specification section 12 24 00 Motorized roller shades annotated as "MRS". Replace in its entirety with the attached specification 10 24 00 Manual Roller Shade (3 pages). Replace all "MRS" with "RS" within the project area.
6. New Item: Refer to drawing 12/A401: Delete in its entirety M1 millwork. GC to provide continuous furring wall as shown in 1/A100 near gridline 7 & E/D complete with WB finish.
7. New Item: Refer to drawing 1/A100 near gridline 7/C: GC to protect and maintain existing kitchenette and plumbing in Meeting Room B1-12A, refer to Mechanical addendum #1.
Mechanical:1. Refer to the attached mechanical addenda M‐1 issued by H.H. Angus and Associates (9 pages).
Electrical:1. Refer to the attached electrical addenda E-1 issued by H.H. Angus and Associates (6 pages).
End of Section
F E D
3
4
5
6
7
8
9
C
EX AV Rack to be removed and handed over to client
EXEX
D6
D3
D4D6
EX
D5
D5
D5D3
D3
D7
D8
D8
D7
D10
D11 D11 D11
D11
D12
D12
D12
D8
D8
D5
D8
D5
D7
D7
D7
D11
D11
D8 D8
EX flooring to remain
9455 9455 6230
3750
3765
3575
3910
3525
N
GENERAL NOTES
1. Existing health and safety equipment on walls to be removed, stored, protected and reinstalled. GC to confirm location with client prior to installation (e.g. hand sanitizer stations, existing convinience phones, emergency phones etc).
2. All existing signage to be removed, stored and relocated as per client's instructions.
3. Patch, paint and repair existing areas damaged during construction.
4. Any removed A.V, I.T and electrical equipment to be handed over to the client.
5. All hoarding to receive graphic wrap, refer to specifications.
DEMOLITION LEGEND
EX
Existing element to be demolished
Existing Door c/w FrameHardware to be salvagedRefer to Door Schedule for locations of re-use.
Flooring and cove base to be removed
Ceiling to be removedRetain existing light fixtures and ACT tiles to handed over to hospital for re-use.
HoardingAll hoarding to receive graphic wrap. Refer to Specifications
F E D
3
4
5
6
7
8
9
C
A401 1
MEN'S WR106A
AUDITORIUMB
B1-11B
WOMEN'SWR
106B
COLLABORATORYB1-12
MEETINGROOMB1-12A
TYP
CLOSETB112B
P2d
4A506
EX107
EX
12
A
EX
12
AUDITORIUMA
B1-11A
D11B
D11A
3
4
2
A401 5
7
8
6
A401
9
1011
12
A40113
14
15
16
new operable partition closet
AP
AP
QUIETSTUDYB1-12B
P2d P2d
P2dWB
P3aP3a
P3a
P3a
P3a P3a
P3a
P3a
P3a
P3aP3a
P3a
P3a
P2d
2200
P2d
P2d
1240
1600
210
13035
6660
8830
8605
4570
EX
11
A
AP
WB
A401 19
AV ClosetB1-12D
EX12B
D12D
GC to coordinate with AV, provided by Owner
3200
WB
1320
1295
875
D11F
A401 17
915
M1WB
2155
P2c
P2c
P1b
AP
AP
ACR ACR ACR
AP
AP
M3
D11C OPA, refer to structural drawings
3650
2535
1150
4945
1106
5
1183
5
5430
905
ALIGN
D155
EX104A
4435
455
4275
A401
20
all EX mech. grilles to receive new PT finish
all EX mech. grilles to receive new PT finish
all EX mech. grilles to receive new PT finish
9455 9455 6230
3910
3750
3765
3575
2155 VIF
VIF
795
VIF
650
VIF
1335
VIF
1335
VIF
1525
VIF
2185
VIF
1940
WB
ACR
ACR
WB
Wiremold, refer to elec. dwgs.
Wiremold, refer to elec. dwgs.
Wiremold, refer to elec. dwgs.
Wiremold, refer to elec. dwgs.
Floor to be repaired to make good and match EX floor finishes + cove base
F E D
3
4
5
6
7
8
9
C
COLLABORATORYB1-12
MEN'S WR106A
WOMEN'SWR
106B
MEETINGROOMB1-12A
AUDITORIUMB
B1-11B
2395
±
8540 (± VIF)
C3
C3
C1
C1
ACT2
3023
1
A505
SIM
RS
RS
C2
C2
STAIRS A1B-213
P
345
LB
LB
LB
LB
LB
BULKHEAD WALL
GWB
2710
BULKHEAD WALLSAROUND ACT, TYP
EXTENT OF GWB COVE CEILING
AUDITORIUMA
B1-11A
Note: -GC to coordinate concealed GWB access panels with consultant. Refer to specs, TYP.
RS
RS
RS
1
A505
SIM
1
A505
SIM
1
A505
SIM
1
A505
SIM
1
A505
SIM
1
A505
SIM
1
A505
SIM
New downlights to replace EX typ., ref. to Elect.
New downlights to replace EX typ.
ACT2
3023
STLB
1280
815
2355
L2
L1
L4 L4 L4
L4 L4 L4
L4 L4 L4
L4 L4 L4
L4 L4 L4
L4 L4 L4
L4 L4 L4
L4 L4
L4 L4
L4 L4
L4L4L4 L4L4
L4
L4
L4
L4
L4
L4
L4
L4
L4L4L4 L4L4
L5
L5
L5
L5
L2 L2 L2 L2
L2 L2 L2 L2 L2
L2
P
L2
L2
L2 L2 L2 L2 L2
L2 L2 L2 L2
835 1950
L3
L3
L3
L1
L1
L1
L1
L1
L1
L1
L1
L1L1
L1
EQ
EQ
705
1525
675
1525
1525
335
1525
705
1525
VIF
1565
EQ
EQ
GWB
2692EX
3100
GWB
2700EX
3100
EX TV
New fixtures to replace EX, Refer to Electrical, TYP.
L1 L1 L1L1
EQ EQ EQ EQ EQ
PS
PS
435
560C4 GWB
2997
EQ EQ
795 EQ
ST
EX. perimeter wood cove fascia to be refinished to match WD
P
GWB
2710
GWB
2710
AV ClosetB1-12D
CLOSETB112B
8885
3670
4840
595
675
665
200
L1
L1
200
Bulkhead wall above OPA
L3
L3L3
L3
L3
L3L3
L3
9455 9455 6230
3910
3750
3765
3575
EX structural beam to be reused, ref. to structuralNew structural beam, ref. to structural
ST
EQ
EQ
EQ
EQ
L1
L1E
Q11
65
EQ
EQ
C5
GWB
2743
GWB
2743
3485
3555
ST
L2
L2
780
SA SA
SA SA
SA SA
SA
F E D
3
4
5
6
7
8
9
C
COLLABORATORYB1-12
MEN'S WR106A
WOMEN'SWR
106B
MEETINGROOMB1-12A
AUDITORIUMB
B1-11B
STAIRS A1B-213
LX
LX
EXTENT OF GWB COVE CEILING
AUDITORIUMA
B1-11A
D2
D3
D3
D3
D9D12
D12
D2
D2
D2
9455 9455 6230
3910
3750
3765
3575
ALL DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS ANDDESIGN ARE THE COPYRIGHT PROPERTY OF THE ARCHITECTAND MUST BE RETURNED UPON REQUEST. REPRODUCTION OFTHE DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS ANDDESIGN IN WHOLE OR IN PART IS STRICTLY FORBIDDEN WITHOUTTHE ARCHITECT'S WRITTEN PERMISSION. THIS DRAWING SHALLNOT BE USED FOR CONSTRUCTION PURPOSES UNLESSCOUNTERSIGNED.
Project Number:
Drawn By:
Checked By:
Scale: As indicated
16-117
CB/FG
PH/NC
A100
SJHC LEARNING CENTRE
30 THE QUEENSWAYTORONTO, ON M6R 1B5
DEMOLITION ANDPROPOSED PLANS ANDRCPs
1 : 1002 LEVEL 1 - CONFERENCE DEMO PLAN
KEY PLAN
DEMOLITION NOTES
D2 EX stepped ceiling (at 2700mm - 3000mm) to be demolished atperimeter of room.
D3 Remove EX blinds and handover to client. Patch, repair and paintwindow surroundings to make good for new motorized roller shade(MRS).
D4 EX wall finish, exterior glazing and wall fin to remain and receivenew PT finish.
D5 Patch & level EX CONC floor as required to prepare floor to receivenew floor finish (TYP) as part of ACP3.
D6 EX folding partition to be removed. Structural support beam toremain & be reused, refer to Structural.
D7 Remove & store or Protect EX artwork during construction. Ownerto confirm final mounting locations.
D8 Remove any EX acoustic wall panel, wainscotting and bulletinboards from rooms.
D9 EX ceiling mounted TV to remain and be protected duringconstruction.
D10 Line of hoardingD11 Remove EX doors and replace with new. Reuse EX hardware.D12 EX AV equipment to be removed & handed over to client for reuse.
No. ISSUED/REVISED DATE
1 ISSUED FOR BLDG PERMIT June 19 20172 ISSUED FOR TENDER Jan. 30, 2018
3 ISSUED FORCONSTRUCTION
May 1, 2018
4 RE-ISSUED FOR BUILDINGPERMIT
April 18, 20195 ISSUED TO CLIENT May 3, 20196 ISSUED FOR ADDENDUM 1 May 9, 2019
1 : 1001 LEVEL 1 - CONFERENCE PROPOSED PLAN
1 : 1003 Level 1 - AUDITORIUM RCP
RCP NOTES
NOTE DESCRIPTION
C1 New RS affixed to underside of window bulkheadC2 Approximate location of new ceiling-mounted projector. Refer to
electrical and AV documents.
C3 Recessed ceiling-mounted projector screen. Refer to electricaland AV documents.
C4 Refer to AV documents for AV equipment, exact locations to bedetermined on site.
C5 Ceiling to be repaired to make good and match EX ceiling tileand grid.
1 : 1004 Level 1 - AUDITORIUM DEMP RCP
MRS @ U/S OF EX OPENINGREFER TO SPECIFICATIONS
EX
PT-1
CB
WD (P2D)
PT-1
CB CB
PT-1PT-1
RECESSED PROJECTOR SCREEN C/L TO PROJECTORREFER TO AV DOCUMENTS
WDLINE OF PS (NIC)
2700
D1
1F
SIM1
A505
SIM1
A505
2600
100
CB CB CB
PT1PT1
EX
11
A
PT1
BBBB AP AP APAPAPAP AP
EQEQEQEQEQ360Align
SIM1
A505
SIM1
A505
2185
Folding parititon, refer to specification
PT1
SIM1
A505
SIM1
A505
Folding parititons (10 panels)
SIM1
A505
SIM1
A505
AP
CB
PT1
2300
EQ EQ
D11
B
525
BB AP
WV PT1
SIM1
A505
SIM1
A505
2080
100
CBCBCBCB
MRS @ U/S OF EX OPENINGREFER TO SPECIFICATIONS
CBCB CB
PT1
PT1 PT1 PT1
AP AP APBB BB
EQEQEQ 300
300
3320
SIM1
A505
SIM1
A505
2080
100
EX glazing
PT1
CB
WD (P2D)
15 g
ap
LINE OF PS (NIC)
D12
D
D11
F
SIM1
A505
SIM1
A505
CB
EX Glazing
MRS @ U/S OF EX OPENINGREFER TO SPECIFICATIONS
2690
MRS @ U/S OF EX OPENINGREFER TO SPECIFICATIONS
1345
760
CB
PT1 PT1
EX Glazing
CB
BB
PT1
1360 2155 1080 280
PT1
WBWB WBShort-Throw Projector, N.I.C.
PT1PT1
CB
M1
WALL MOUNT PROJECTOREXACT LOCATION TO BE CONFIRMED BY
AV CONSULTANT PRIOR TO INSTALL
PLAM
Short-Throw Projector, N.I.C.
EQ EQ
WB
CB
EQ EQ
915
SS
EX
10
4A
D15
5
1345
760
1345
760
2155
2160
WB
Short-Throw Projector, N.I.C.
WB
WB WB
EQ EQ EQ
PT1
Logo location (NIC)
760
1345
CB
PT1
300
WB AP AP
1345
1000
1190 2160 650 650 1000
760
1345
WB
EQ EQ
Short-Throw Projector, N.I.C.
WB
MRS @ U/S OF EX OPENINGREFER TO SPECIFICATIONS
EX Glazing
CB
PT1
PT1
CB
PT1
115
2080
6570
AP1480 300 920 630 1480 1480 300
AP AP AP APBB BB
CB
PT1
CB
EX
12
A
EX millwork
Wall at angle
APAPBBAP
CB
Align to door
PT1
D11
A
D11
C
BB
820 300 920 1400 630 300
AP
WD
PT1
SIM1
A505
SIM1
A505
CB CB
2080
100
CBCBCB
WBPT1
CB CB
EX
12
WB WB
WB
WB
WB
735 2440 2440 505
WB
WB
WB
WB
WB
WB
D11
B
D11
A
PT1
PT1 PT1 PT1
CB CB CB CB
Wall at angle
2745
PT1
PT1
ACR on adjacent
walls
ACR on adjacent
walls
Donor wall location (NIC)
ACR
2625
895
25mm high alum u-channel, top/bottom TYP.
alum L-channel to conceal vertical edges TYP.
EX electrical panel
100
2450
PT-1
25
APAPAP
EQ EQ EQ
RB
ALL DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS ANDDESIGN ARE THE COPYRIGHT PROPERTY OF THE ARCHITECTAND MUST BE RETURNED UPON REQUEST. REPRODUCTION OFTHE DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS ANDDESIGN IN WHOLE OR IN PART IS STRICTLY FORBIDDEN WITHOUTTHE ARCHITECT'S WRITTEN PERMISSION. THIS DRAWING SHALLNOT BE USED FOR CONSTRUCTION PURPOSES UNLESSCOUNTERSIGNED.
Project Number:
Drawn By:
Checked By:
Scale: As indicated
16-117
CB/FG
PH/NC
A401
SJHC LEARNING CENTRE
30 THE QUEENSWAYTORONTO, ON M6R 1B5
INTERIOR ELEVATIONS
1 : 501 AUDITORIUM B - NORTH ELEVATION
No. ISSUED/REVISED DATE
1 ISSUED FOR BLDG PERMIT June 19 20172 ISSUED FOR TENDER Jan. 30, 2018
3 ISSUED FORCONSTRUCTION
May 1, 2018
4 RE-ISSUED FOR BUILDINGPERMIT
April 18, 20195 ISSUED TO CLIENT May 3, 20196 ISSUED FOR ADDENDUM 1 May 9, 2019
1 : 506 AUDITORIUM A - EAST ELEVATION
1 : 507 AUDITORIUM A - WEST ELEVATION
1 : 502 AUDITORIUM B - EAST ELEVATION
1 : 504 AUDITORIUM B - SOUTH ELEVATION
1 : 503 AUDITORIUM B - WEST ELEVATION
1 : 505 AUDITORIUM A - NORTH ELEVATION
1 : 509 COLLABORATORY - WEST ELEVATION
1 : 5010 COLLABORATORY - NORTH ELEVATION
1 : 5011 COLLABORATORY - SOUTH ELEVATION
1 : 5013 CLASSROOM - SOUTH ELEVATION
1 : 5014 CLASSROOM - WEST ELEVATION
1 : 5015 CLASSROOM - NORTH ELEVATION
1 : 5016 CLASSROOM - EAST ELEVATION
1 : 508 AUDITORIUM A - SOUTH ELEVATION
1 : 5012 COLLABORATORY - EAST ELEVATION
1 : 2518 ACR Graphic Template
1 : 5019 CAFETERIA ELEVATION
1 : 5017 Typical Alcove
1 : 5020 QUIET STUDY - EAST ELEVATION
REFER TO SPECIFICATIONS TYPICAL OF 5 PANELS, REF. TO PLAN
09 72 10 DRY ERASE PROJECTABLE WALLCOVERING
PAGE 1
PART 1 – GENERAL 1.1 RELATED DIVISIONS 1. Division 26 51 00 Interior Lighting.
2. Division 09 20 00 Plaster and Gypsum Board: Wall substrate. 3. Division 09 91 23 Interior Painting: Priming for vinyl wall coverings.
4. Division 09 72 16.13 Flexible Vinyl Wall Coverings. 5. Division 10 11 00 Visual Display Surfaces: Chalk and markerboards.
1.2 REFERENCES
1. American Society for Testing and Materials ASTM E84 Test Method for Surface Burning Characteristics of Building Materials.
2. Gypsum Association GA-214-M-97 Recommended Levels of Gypsum Board Finish. 1.3 SUBMITTALS
1. Manufacturer’s product data and installation instructions for each type of dry erase wallcovering, adhesive, and accessories required.
2. Manufacturer’s written product data indicating compliance with specified materials required. 3. Manufacturer’s written installation instructions. 4. Manufacturer’s written instructions for recommended maintenance of each type of dry erase
wall covering required. 5. Samples:
1. 7 inch (177.8mm) x 9 inch (228.6mm) samples of each dry erase material required.
2. 6 inch (152.4mm) samples of trim, tray, and end caps required. 1.4 QUALITY ASSURANCE
1. Manufacturer: Provide each type of dry erase wallcovering required produced by one manufacturer. 2. Surface Burning Characteristics Classification: Provide materials that meet Class I/A rating
when tested in accordance with ASTM E84 for flame spread and smoke developed. 3. Field Samples: Prepare field samples for architect’s review and establish requirements for seaming and finish trim. 4. Install sample panel of each type presentation wallcovering specified in area designated by
architect. 5. Maintain corrected and approved samples to serve as a standard of performance for the
project. 6. Installer: Installation by skilled commercial wallcovering contractor with no less than three
years of documented experience installing dry erase wallcovering of the types and extent required.
09 72 10 DRY ERASE PROJECTABLE WALLCOVERING
PAGE 2
1.5 PRODUCT DELIVERY, STORAGE, AND HANDLING 1. Deliver presentation wallcoverings to the project site in unbroken and undamaged original
factory packaging and clearly labeled with the manufacturer’s identification label, quality or grade, and lot number.
2. Store materials in a clean, dry storage area with temperature maintained above 55°F (13°C) with normal humidity. 3. Store material within original packaging to prevent damage.
1.6 PROJECT CONDITIONS 1. Do not apply presentation wallcoverings when surface and ambient temperatures are
outside the temperature ranges required by the wallcovering manufacturer. 2. Provide continuous ventilation and heating facilities to maintain substrate surface and
ambient temperatures above 55°F (13°C) unless required otherwise by manufacturer’s instructions.
3. Apply adhesive when substrate surface temperature and ambient temperature is above 55°F (13°C) and relative humidity is below forty percent.
4. Maintain constant recommended temperature and humidity for at least 72 hours prior to and throughout the installation period, and for 72 hours after wallcovering installation completion.
5. Provide not less than 80-foot-candles per square foot lighting level measured mid-height at substrate surfaces.
1.7 ` WARRANTY
Submit manufacturer’s limited five-year written warranty against manufacturing defects. 1.8 MAINTENANCE
Maintenance instructions: Include precautions against cleaning materials and methods that may be detrimental to finishes and performance.
PART 2 - PRODUCTS 2.1 MANUFACTURER
1. Wallcoverings: Walltalkers Wallcoverings manufactured by Koroseal Interior Products, LLC., Fairlawn, Ohio, and distributed by Blue Sky Agency. 2. Egan VersaPro manufactured by Egan visuals Inc. and distributed by Metro Wall Coverings. 3. Architect approved Alternate.
2.2 MATERIALS 1. (WB) Walltalkers matte•rite: Smooth low gloss vinyl surface for projection and dry
erase markers or approved similar. 1. MP60: 59/60 inch (1.50/1.52m) width, non-woven backing, white finish.
09 72 10 DRY ERASE PROJECTABLE WALLCOVERING
PAGE 3
2. Thickness: 0.43mm 3. Hang: reverse every other strip. 4. Flammability testing: Class A. 5. Substrate primer: white pigmented acrylic base primer/sealer specifically formulated for
use with vinyl wall coverings. 6. Mounting substrate: MDF substrate, continuous finished mounting surface to be
equivalent of GWB level 4 finish per GA-214-M-97. 2. Composition:
1. matte•rite®: Provide non-woven backing with white pigmented vinyl capped with dry erase low gloss film, or approved similar.
2.3 TRIM & TRAY
1. Aluminum Tray: Clear satin, anodized aluminum, snap-on marker and eraser tray with Clips. Specify length: 4’ length and 8’ length refer to elevations.
2. End Caps: 1. ET03-00: 1/2 inch (13mm) anodized tray end cap set for marker and eraser tray. 3. Trim: Elite trim with 1/8” reveal, Supplier: Architectural School products or approved similar. Trim to be provided on all exposed perimeter edges. 2.4 ACCESSORIES 1. Adhesives: Heavy-duty clear or clay based premixed vinyl adhesive. 2. Substrate Primer/Sealer: White pigmented acrylic base primer/sealer specifically formulated for use with vinyl wallcoverings. 3. Broad Tip Dry Erase Markers: 1. EC12-99: Chisel BLK - 12CT 2. EC04-00: Set of four colors: red, blue, green, black. 4. Eraser: 1. DEFE-99: Dry erase felt eraser. 2. DECC-Y1: Dry erase cleaning cloth - yellow. PART 3 - EXECUTION
3.1 EXAMINATION
1. Examine substrates and installation conditions to ensure surface conditions meet or exceed a Level 4 finish, per GA-214-M-97: Recommended Levels of Gypsum Board Finish, and permanent lighting should be installed and operational.
2. Test substrate with suitable moisture meter and verify that moisture content does not exceed four percent.
3. Verify substrate surface is clean, dry, smooth, structurally sound, and free from surface defects and imperfections that would show through the finished surface.
4. Evaluate all painted surfaces for the possibility of pigment bleed-through. 5. Notify the contractor and architect in writing of any conditions detrimental to the proper and
timely completion of the installation.
09 72 10 DRY ERASE PROJECTABLE WALLCOVERING
PAGE 4
6. Beginning of installation means acceptance of surface conditions. 3.2 INSTALLATION Wallcovering backing.
1. Acclimate wallcovering in the area of installation a minimum of 24 hours before installation. 2. Read and follow the manufacturer’s installation instruction sheet contained in each roll of the
dry erase wallcovering. 3. Examine all materials for pattern, color, quantity and quality, as specified for the correct
location prior to cutting. 4. Primer: Use a quality pigmented acrylic wallcovering primer. 5. Adhesive: Apply a uniform coat of heavy-duty pre-mixed clay-based or extra strength clear wallcovering adhesive. 6. Install each strip horizontally and in the same sequence as cut from the roll. 7. Install dry erase wallcovering sheets in exact order as they are cut from bolt. Reverse hang
alternate strips (except lined products). Do not crease or bend the wallcovering when handling.
8. Install dry erase wallcovering horizontally using a level line. 9. Using a level or straight edge, double cut the seam with a seam-cutting tool (Ex: Double Seam-Cutter or Swedish Knife). Do not score drywall or plasterboard when cutting material. 10. When covering the entire wall, seam the material out of the main writing and viewing areas
of the wall. 11. Apply wallcovering to the substrate using a wallcovering smoother, wrapped with a soft
cloth, to remove air bubbles. Do not use sharp edged smoothing tools. Smooth material on the wall from the middle to the outside edge.
12. Remove excess adhesive immediately after the wallcovering is applied. Clean entire surface with a warm mild soap solution, and clean soft cloths. Rinse thoroughly with water and let dry before using. Change water often to maintain water clarity.
13. Stop installation of material that is questionable in appearance and notify the manufacturer’s representative for an inspection.
3.3 CLEAN-UP
A. Upon completion of installation, remove all exposed adhesive immediately using a soft cloth and a warm, mild soap solution and rinse thoroughly with water and dry with clean towel prior to using.
B. Upon completion of the work, remove surplus materials, rubbish, and debris resulting from the wallcovering installation. Leave areas in neat, clean, and orderly condition.
END OF SECTION
SECTION 10 24 00 Manual Roller Shade
Page 1
Part I – GENERAL
A. SUMMARY 1. Section Includes
a. Manual Operated Roller Shade 2. Related Work includes the following
b. Section 06100 Rough Carpentry c. Section 08520 Aluminum Windows
B. REFERENCES 1. National Fire Protection Association (NFPA) 701 2. Department of Transportation Motor Vehicle Safety Standard 302 Flammability of Interior
Materials 3. California Administrative Code Title 19 4. Federal Standard 191 Method 5903 (used by Port Authority of New York and New Jersey
for drapery, curtain, and upholstery material) 5. Boston Fire Department Test BFD IX-1 6. New York State Uniform Fire Prevention and Building Code
C. SUBMITTALS 1. Subject under provisions of Section 01 33 00 – Submittal Procedures 2. Product Data: Manufacturer’s data sheets shall be submitted for each product specified,
including: a. Preparation instructions and recommendations b. Finishes, material descriptions, dimensions of individual components c. Construction and installation instructions d. Manufacturers recommendations for maintenance and cleaning
3. Drawings and Diagrams: Product details, installation details, working and assembly drawings shall be supplied as requested
4. Sample: Responsible contracting officer or agent shall supply one sample shade of each type specified in this contract for approval. Supplied units shall be furnished complete with all required components, mounting and associated hardware, instructions and warranty.
5. Electric shade motors shall comply with UL standards. Copy of compliance available for submission upon request.
D. QUALITY ASSURANCE 1. Supplier: Manufacturer, subsidiary, or licensed agent shall be approved to supply the
products specified, and to honor any claims against product presented in accordance with warranty.
2. Installer: Installer or agent shall be qualified to installed specified products by prior experience, demonstrated performance and acceptance of requirements of manufacturer, subsidiary, or licensed agent. Installer shall be responsible for an acceptable installation.
3. Uniformity: Provide product of only one manufacturer for entire project. 4. Mock up: Provide one (1) mock-up shade for each roller shade type/assembly specified.
E. DELIVERY, STORAGE, AND HANDLING 1. Product shall be delivered to site in manufacturer’s original packaging. 2. Product shall be handled and stored to prevent damage to materials, finishes, and
operating mechanisms. F. JOB CONDITIONS
1. Prior to shade installation, building shall be enclosed.
SECTION 10 24 00 Manual Roller Shade
Page 2
2. Interior temperature shall be maintained between 60 degrees Fahrenheit and 90 degrees Fahrenheit during and after installation; relative humidity shall not exceed 80%. Wet work shall be complete and dry.
G. WARRANTY 1. Provide a limited manufacturer’s warranty from date of Substantial Completion covering
the following periods. a. Lifetime Limited Warranty on all hardware components, fabrics warrantied for 5 years
by Hunter Douglas, and most fabrics warrantied for 10 years by the fabric manufacturer. Specific and custom product warranties available from manufacturer or its authorized agent.
Part II – PRODUCTS
A. ACCEPTABLE MANUFACTURER 1. Lutron or architect approved equivalent. 2. Request for substitutions must be approved by architect minimum of 7 days prior to close
of bid. B. (RS) MANUAL CONTRACT DUAL ROLLER SHADE C. FABRICS: Inherently anti-static, flame retardant, fade and stain resistant, light filtering, room
darkening, and blackout fabrics providing 5% openness, 5 oz/sq. yd to 20.70 oz/sq. yd, containing fiberglass, vinyl content. Colour to TBD.
D. Horizontal stabilizing battens are not required, nor will they be accepted.
1. CONTROL SYSTEMS: .
a. CLUTCH OPERATED: Chain-driven operator capable of operating fabric panels from 13 to 16 feet wide (maximum width varies by fabric weight) and up to 20 feet tall with a maximum allowable pull force of 9 pounds. Utilization of adjustment-free continuous qualified T304 stainless ball chain with 110 lbs. breaking strength for precise control, smooth operation, and ensures a uniform look. Components must be maintenance-free from adjustments or lubrication for trouble-free lifetime operation. 1. 90 pound breaking strength chains will not be accepted. 2. Chain anchor device to be compliant with WCMA safety standard A100.1.1-
2010 and must prevent the clutch system from moving the roller shade through lowering and raising if not properly installed as specified in ANSI Standard Section 6.5.2.
b. ROLLER TUBE: Circular-shaped aluminum tube extruded from alloy and temper 6063 T-6. Extruded tube to have a .063” wall thickness (2.5” outside diameter to have a 0.79” wall thickness). Heavily reinforced with minimum of six internal ribs and flutes providing additional tensile strength and allows for secure placement of clutch and end plug.
c. SPRING-LOADED IDLE END: Reinforced idler assembly containing spring loaded end plug with positive locking wheel allowing for up to 7/8” adjustment and provides for a secure installation and removal of shade. Locking tube bearing plug contains minimum 6 ribs and flutes and inserted a minimum of 2 3/8” into roller tube on heavy duty systems.
d. BOTTOM BAR: Industry standard sealed hembar with weight sewn into pocket providing for tracking adjustments and uniform look of the hanging fabric panel. Options include: Bottom Bar, aluminum finish.
e. MOUNTING HARDWARE: Manufacturer’s standard or heavy duty bracket constructed of hardened 1/8” thick steel to support full weight of shade with
SECTION 10 24 00 Manual Roller Shade
Page 3
bracket and screw hole covers to provide uniform look. Locking mechanism on bracket adapter provides for a secure installation and removal of the shade. 1. Cradle-seated hardware without a locking mechanism will not be accepted.
f. INTEGRATED LEVELING DEVICE: Built into the idle-end bracket (or intermediate bracket of a coupled shade) allowing for the vertical height adjustment of +/- one-half inch direction up or down, allowing the easy leveling of a fabric panel on its mounting surface. This assists to keep the fabric rolling square to the tube, minimizing the chance of the fabric rolling into its hardware causing creases and damage to the ends of the fabric. 1. Adjusting fabric skewing through means of tape, paper, or cardboard tucked
up inside the fabric at the tube is not acceptable. g. FASCIA: Ceiling-mounted L-shaped removable aluminum extrusion valance that
attaches to brackets and conceals roller shade. Fascia at the bottom enclosure must allow a maximum of 1” gap to allow fabric to come through. Exposure underneath greater than 1” is not to be accepted.
h. BLOCKOUT SYSTEM: Extruded aluminum side channel with concealed mounting brackets. Bottom bar with Nylon wool pile to prevent light leakage.
E. FABRICATION 1. Shade measurements shall be accurate to within +/- 1/8” or as recommended in writing
by manufacturer. F. FABRICS: Fabric: include full range of Avila blackout blinds and Basketweave. Colour and
openness TBD.
Part III – EXECUTION
A. Inspection 1. Subcontractor shall be responsible for inspection on site, approval of mounting surface,
installation conditions, and field measurement for this work. 2. Other interacting trades shall receive drawings of shade systems, dimensions, assembly,
and installation methods from subcontractor upon request. B. Installation
1. Installation shall comply with manufacturer’s specifications, standard and procedures as detailed on contract drawings
2. Adequate clearance shall be provided to permit unencumbered operation of shade and hardware.
3. Clean finish installation of dirt and finger marks. Leave work area clean and free of debris.
C. Demonstration 1. Demonstrate operation method and instruct owner’s personnel in the proper operation
and maintenance of the roller shades.
END OF SECTION
St. Joseph’s Health Centre Learning Centre Revisions HHA #2161346-02
Section M-1Addenda M-1
Page 1 of 1
H.H. Angus and Associates
ADDENDA M-1
The information listed below is to form part of the Contract Documents. All associated costs are to
be included in Tender Price shown on Tender Form. Acknowledgment of this Addendum, by number, to be shown in space provided on Tender Form.
1 DRAWINGS
1.1 M001 – Mechanical Legend & Drawing List (re-issued)
.1 Replace previously issued version of this drawing with the copy attached herewith.
1.2 M002 – Mechanical Schedules (re-issued)
.1 Replace previously issued version of this drawing with the copy attached herewith.
1.3 M100 – Level 1 Plumbing Demo (re-issued)
.1 Replace previously issued version of this drawing with the copy attached herewith.
1.4 M200 – Level 1 Heating Demo (re-issued)
.1 Replace previously issued version of this drawing with the copy attached herewith.
1.5 M201 – Level 1 Heating New (re-issued)
.1 Replace previously issued version of this drawing with the copy attached herewith.
1.6 M300 – Level 1 Ventilation Demo (re-issued)
.1 Replace previously issued version of this drawing with the copy attached herewith.
1.7 M301 – Level 1 Ventilation New (re-issued)
.1 Replace previously issued version of this drawing with the copy attached herewith.
1.8 M400 – Level 1 Fire Protection Demo and New (re-issued)
.1 Replace previously issued version of this drawing with the copy attached herewith.
END OF ADDENDUM
As indicated
M001
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
MECHANICAL LEGEND
AND DRAWING LIST
KEY PLAN
No. ISSUED/REVISED DATE
ALL DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT
AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF
THE DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN IN WHOLE OR IN PART IS STRICTLY FORBIDDEN WITHOUT
THE ARCHITECT'S WRITTEN PERMISSION. THIS DRAWING SHALL
NOT BE USED FOR CONSTRUCTION PURPOSES UNLESS
COUNTERSIGNED.
Project Number:
Drawn By:
Checked By:
Scale:
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
No. ISSUED/REVISED DATE
HHAngus & Associates Limited Consulting Engineers1127 Lesl ie Street , Toronto, ON, M3C 2J6 Canadawww.hhangus.com | T 416 443 8200 | F 416 443 8290
2161346
ISSUED FOR ADDENDUM #M11. 2019/05/09
As indicated
M002
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
MECHANICAL SCHEDULES
KEY PLAN
ISSUED/REVISED DATE
ALL DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT
AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF
THE DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN IN WHOLE OR IN PART IS STRICTLY FORBIDDEN WITHOUT
THE ARCHITECT'S WRITTEN PERMISSION. THIS DRAWING SHALL
NOT BE USED FOR CONSTRUCTION PURPOSES UNLESS
COUNTERSIGNED.
Project Number:
Drawn By:
Checked By:
Scale:
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
No. ISSUED/REVISED DATE
HHAngus & Associates Limited Consulting Engineers1127 Lesl ie Street , Toronto, ON, M3C 2J6 Canadawww.hhangus.com | T 416 443 8200 | F 416 443 8290
2161346
ISSUED FOR ADDENDUM #M11. 2019/05/09
As indicated
M100
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
LEVEL 1 PLUMBING DEMO &
NEW
ISSUED/REVISED DATE
ALL DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT
AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF
THE DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN IN WHOLE OR IN PART IS STRICTLY FORBIDDEN WITHOUT
THE ARCHITECT'S WRITTEN PERMISSION. THIS DRAWING SHALL
NOT BE USED FOR CONSTRUCTION PURPOSES UNLESS
COUNTERSIGNED.
Project Number:
Drawn By:
Checked By:
Scale:
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
No. ISSUED/REVISED DATE
HHAngus & Associates Limited Consulting Engineers1127 Lesl ie Street , Toronto, ON, M3C 2J6 Canadawww.hhangus.com | T 416 443 8200 | F 416 443 8290
2161346
KEY PLAN
ISSUED FOR ADDENDUM #M11. 2019/05/09
As indicated
M200
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
LEVEL 1 HEATING DEMO
ISSUED/REVISED DATE
ALL DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT
AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF
THE DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN IN WHOLE OR IN PART IS STRICTLY FORBIDDEN WITHOUT
THE ARCHITECT'S WRITTEN PERMISSION. THIS DRAWING SHALL
NOT BE USED FOR CONSTRUCTION PURPOSES UNLESS
COUNTERSIGNED.
Project Number:
Drawn By:
Checked By:
Scale:
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
No. ISSUED/REVISED DATE
HHAngus & Associates Limited Consulting Engineers1127 Lesl ie Street, Toronto, ON, M3C 2J6 Canadawww.hhangus.com | T 416 443 8200 | F 416 443 8290
2161346
KEY PLAN
ISSUED FOR ADDENDUM #M11. 2019/05/09
DISHWASH
1B-110
VENDING
MACHINES
101
CORRIDOR
1B-101A
AUDITORIUM
B
B1-11B
COLLABORATORY
B1-12
MEETING
ROOM
B1-12A
CORRIDOR
C101
ECOLOGIZER
1B-110B
JANITORIAL
1B-110A
MEN'S WR
106A
WOMEN'S
WR
106B
STAIRS A
1B-213
STAIRS
1B-214
STOR.
D107
As indicated
M201
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
LEVEL 1 HEATING NEW
ISSUED/REVISED DATE
ALL DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT
AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF
THE DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN IN WHOLE OR IN PART IS STRICTLY FORBIDDEN WITHOUT
THE ARCHITECT'S WRITTEN PERMISSION. THIS DRAWING SHALL
NOT BE USED FOR CONSTRUCTION PURPOSES UNLESS
COUNTERSIGNED.
Project Number:
Drawn By:
Checked By:
Scale:
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
No. ISSUED/REVISED DATE
HHAngus & Associates Limited Consulting Engineers1127 Lesl ie Street, Toronto, ON, M3C 2J6 Canadawww.hhangus.com | T 416 443 8200 | F 416 443 8290
2161346
KEY PLAN
ISSUED FOR ADDENDUM #M11. 2019/05/09
As indicated
M300
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
LEVEL 1 VENTILATION DEMO
ISSUED/REVISED DATE
ALL DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT
AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF
THE DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN IN WHOLE OR IN PART IS STRICTLY FORBIDDEN WITHOUT
THE ARCHITECT'S WRITTEN PERMISSION. THIS DRAWING SHALL
NOT BE USED FOR CONSTRUCTION PURPOSES UNLESS
COUNTERSIGNED.
Project Number:
Drawn By:
Checked By:
Scale:
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
No. ISSUED/REVISED DATE
HHAngus & Associates Limited Consulting Engineers1127 Lesl ie Street, Toronto, ON, M3C 2J6 Canadawww.hhangus.com | T 416 443 8200 | F 416 443 8290
2161346
KEY PLAN
ISSUED FOR ADDENDUM #M11. 2019/05/09
DISHWASH
1B-110
VENDING
MACHINES
101
CORRIDOR
1B-101A
AUDITORIUM
B
B1-11B
COLLABORATORY
B1-12
MEETING
ROOM
B1-12A
CORRIDOR
C101
ECOLOGIZER
1B-110B
JANITORIAL
1B-110A
MEN'S WR
106A
WOMEN'S
WR
106B
STAIRS A
1B-213
STAIRS
1B-214
STOR.
D107
As indicated
M301
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
LEVEL 1 VENTILATION NEW
ISSUED/REVISED DATE
ALL DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT
AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF
THE DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN IN WHOLE OR IN PART IS STRICTLY FORBIDDEN WITHOUT
THE ARCHITECT'S WRITTEN PERMISSION. THIS DRAWING SHALL
NOT BE USED FOR CONSTRUCTION PURPOSES UNLESS
COUNTERSIGNED.
Project Number:
Drawn By:
Checked By:
Scale:
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
No. ISSUED/REVISED DATE
HHAngus & Associates Limited Consulting Engineers1127 Lesl ie Street, Toronto, ON, M3C 2J6 Canadawww.hhangus.com | T 416 443 8200 | F 416 443 8290
2161346
KEY PLAN
ISSUED FOR ADDENDUM #M11. 2019/05/09
DISHWASH
1B-110
VENDING
MACHINES
101
CORRIDOR
1B-101A
AUDITORIUM
B
B1-11B
COLLABORATORY
B1-12
MEETING
ROOM
B1-12A
CORRIDOR
C101
ECOLOGIZER
1B-110B
JANITORIAL
1B-110A
MEN'S WR
106A
WOMEN'S
WR
106B
STAIRS A
1B-213
STAIRS
1B-214
STOR.
D107
As indicated
M400
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
LEVEL 1 FIRE PROTECTION
DEMO AND NEW
ISSUED/REVISED DATE
ALL DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT
AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF
THE DRAWINGS, SPECIFICATIONS, RELATED DOCUMENTS AND
DESIGN IN WHOLE OR IN PART IS STRICTLY FORBIDDEN WITHOUT
THE ARCHITECT'S WRITTEN PERMISSION. THIS DRAWING SHALL
NOT BE USED FOR CONSTRUCTION PURPOSES UNLESS
COUNTERSIGNED.
Project Number:
Drawn By:
Checked By:
Scale:
SJHC LEARNING CENTRE
30 THE QUEENSWAY
TORONTO, ON M6R 1B5
No. ISSUED/REVISED DATE
HHAngus & Associates Limited Consulting Engineers1127 Lesl ie Street, Toronto, ON, M3C 2J6 Canadawww.hhangus.com | T 416 443 8200 | F 416 443 8290
2161346
KEY PLAN
ISSUED FOR ADDENDUM #M11. 2019/05/09
St. Joseph’s Health Centre Learning Centre Revisions HHA #2161346-02
Section E-1Addenda E-1
Page 1 of 1
H.H. Angus and Associates
ADDENDA E-1
The information listed below is to form part of the Contract Documents. All associated costs are to
be included in Tender Price shown on Tender Form. Acknowledgment of this Addendum, by number, to be shown in space provided on Tender Form.
1 DRAWINGS
1.1 E000 – Electrical Legend and Drawing List (re-issued)
.1 Replace previously issued version of this drawing with the copy attached herewith.
1.2 E100 – Electrical Demolition Plan (re-issued)
.1 Replace previously issued version of this drawing with the copy attached herewith.
1.3 E200 – Electrical Lighting, Power and Systems Plan (re-issued)
.1 Replace previously issued version of this drawing with the copy attached herewith.
1.4 E200B – Electrical Lighting, Power and Systems Plan – Alternate Lighting Option (Separate Price) (not issued)
.1 This drawing is the same as re-issued drawing E200 EXCEPT in Auditorium A and B, light fixture type ‘LA’ is a 2’x6’ version of the fixture in order to accommodate the 2’x6’ ACT ceiling type which shall be a separate price. Quantity of ‘LA’ light fixtures shall be the same as seen on re-issued drawing E200.
1.5 E300 – Electrical Details Sheet 1 and E300 – Electrical Details Sheet 2 (re-issued)
.1 Replace previously issued versions of these drawings with the copies attached herewith.
END OF ADDENDUM