16
LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made easy Introduction The operation and instruction manual provides the following information: Mounting and installation Service instructions Electrical installation drawing Installation and parts drawing

Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

  • Upload
    donhu

  • View
    223

  • Download
    3

Embed Size (px)

Citation preview

Page 1: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

LMS100Magnetic level gauge switch

Operating Instruction Manual OI/LMS100-EN Rev. A

KTEK products

Measurement made easy

IntroductionThe operation and instruction manual provides the following information:

– Mounting and installation – Service instructions – Electrical installation drawing – Installation and parts drawing

Page 2: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

2 OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch

Table of Contents

1.0 Introduction .............................................................3

2.0 Application ..............................................................3

3.0 Operation .................................................................3

4.0 Mounting & Adjustment ..........................................3 4.1 Standard Mounting. .............................................4 4.2 Rod Mounting ......................................................4

5.0 Installation ...............................................................5 5.1 General Installation. ............................................5 5.2 Requirements for Hazardous Locations ..............6 5.2.1 General Guidelines ....................................6 5.2.2 Nameplate Marking Procedure (Declaration of Protection Concept) ...........6 5.2.3 Flameproof / Explosion Proof Requirements ...................................7 5.2.4 Protection by Enclosure Requirements ......7 5.2.5 Inrinsic Safety / Non-Incendive Requirements ............................................8 5.3 Typical Applications ............................................9 5.4 Typical D.C. Applications ....................................9 5.5 Typical A.C. Applications ....................................9

6.0 Service ...................................................................10

7.0 Replacement Parts ................................................11

8.0 DatasheetSpecifications ......................................12

9.0 Ordering Information .............................................13

10.0 Warranty Statement ..............................................14

11.0 RMA Form .............................................................15

Page 3: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch 3

1.0 IntroductionThe LMS100 is a magnetically actuated single pole, double throw switch. When the LMS100 is mounted on a KM26 Magnetic Level Gauge, LS Series Cage Level switch or an External Cham-ber that contains a magnetic float, it can sense high or low levels within a vessel. The unique magnetic coupling action eliminates the need for seals, diaphragms, spring or torque tubes. There is no physical contact with the process. Magnetic coupling also eliminates the necessity of process connections and ensures total isolation from the process.

2.0 ApplicationThe LMS100 will provide either a normally open or normally closed dry contact which may be used to activate external devic-es such as alarms or solenoids. Its main application is to sense the passing of a magnetic float in a KM26, or similar chamber, attached to a vessel containing a fluid. These trip points can be used for alarms or to activate a pump motor starter relay.

3.0 OperationThe LMS100 consists of a form C reed switch and a magnet. The reed switch uses precious metal contacts in an inert gas at-mosphere sealed by glass to metal bond. A magnetic float travel-ing relative to the LMS100 causes the reed switch to change state. After the float has passed, the reed switch will maintain its state until the float reverses direction and passes the switch in the opposite direction. The action of the switch is break before make. The hermetically sealed contacts serve to ensure a high degree of hazardous area safety, weather resistance and general reliability of the product.

4.0 Mounting & AdjustmentThe LMS100 is mounted using two stainless steel clamps that pass around the mounting ears attached to the switch housing. The switch can be easily positioned by loosening the clamp and sliding the switch to the correct position on the chamber. Other switches can be added at any time, without the concern for ad-ditional process piping or valves. Note that two switches can be mounted so that they can trip at the same point.

NOTE:1. Do not use the switch on chambers with operating temperatures above 300°F

/ 149°C without using insulation between the switch and the chamber to keep the temperature of the switch from exceeding 300°F/ 149°C. Consult factory.

2. Any conduit or fittings connected to an LMS100 magnetically activated switch should be non-magnetic material. This is necessary to avoid interference with the operation of the KM26 Magnetic Liquid Level Indicator or other magneti-cally activated switches.

Page 4: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

4 OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch

4.1 Standard Mounting

The following procedure outlines the steps necessary to install the switch:1. Mount the switch to the chamber where you want the switch to trip.

The switch should be mounted 90° from the indicator assembly to insure optimum magnetic coupling.

2. The float must be cycled past the switch in both directions to insure that the switch will operate properly when put into service.

Example Configurations:

LMS100 Mounted on KM26 Magnetic

Level GaugeKM26 MLG

LMS100 (LO LEVEL SWITCH)

LMS100 (HI LEVEL SWITCH)

KM26 Chamber Rod Mount

LMS100 Rod Mounting Hardware

Swivel Mounting Bolts

LMS100 Switch

Note: 1. KM26 chambers that are furnished with factory in-

stalled insulation blankets may have switches mounted via special rod mount brackets to a factory installed switch mount rod that is external to the insulation. (See section 4.2)

2. When mounting/adjusting rod mounted LMS100, ensure that the mounting “ears” of the switch are flush against the float chamber to allow proper switch function. Also, be sure to tighten all mounting bolt hardware once switch is correctly mounted into posi-tion (figure 4.2)

LS700 (LS Series)

LMS100

LMS100 Mounted on LS Series Mechanical Level Switch

4.2 Rod Mounting

Page 5: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch 5

5.0 Installation WARNING! SERVICE TEMPERATURE OF THE LMS100 IS

DEPENDENT ON PROCESS TEMPERATURE, MOUNTING METHOD, AND INSULATION USAGE. REFER TO THE TABLE BELOW TO DETERMINE THE MAXIMUM SAFE PROCESS TEMPERATURE FOR EACH APPROVED COMBINATION OF INSULATION AND MOUNTING. Mounting Insulation Max Process

Standard (A1) None (Y0) 300 °F (148.8 °C)

Rod Mount (A2) None (Y0) 350°F (176.6 °C)

Standard (A1) Insulation Pad (P1) 575°F (301.6 °C)

Rod Mount (A2) Chamber Insulation 800°F (426.6 °C)

CAUTION! TO ENSURE SAFE AND RELIABLE OPERATION, DO NOT OPERATE THE SWITCH BEYOND THE FOLLOWING MAXIMUM ELECTRICAL PARAMETERS: MAX VOLTAGE: 250 V AC/DC MAX CURRENT: 1 A MAX POWER: 60 W/VA

5.1 General InstallationCAUTION: Make sure Circuit is de-energized prior to Installing the

switch. If INstalling in a hazadous location, Read requirements in 5.2 before proceeding.

1. To remove the cover, first unlock the cover security bolt located at the 5 o’clock position of the cover, by turning it clockwise with an M2.5 hex key. When the bolt head no longer touches the cover, grip the cover tightly and rotate it counterclockwise to remove.

2. Remove the terminal plug from the terminal. Connect the field wires to the terminal plug according to the application. See the wiring diagram below. (figure 5.1a)

3. All field wiring that is connected to the LMS100 switch must comply with NEC, CEC, or any other applicable regional electrical codes.

Figure 5.1b

GROUND

NORMALLY CLOSED

COMMON

NOMALLY OPEN

GROUND

CN.C.

N.O.

LMS100: Float Below Switch

CN.O.

N.C.

LMS100: Float Above Switch

Figure 5.1a: Contact closure shown for both condi-tions of the switch relative to the magnetic float.

Page 6: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

6 OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch

5.2 Requirements for Hazardous Locations5.2.1 General Guidelines

1. WARNING! MAKE SURE ALL CIRCUITS ARE DE-ENER-GIZED PRIOR TO INSTALLATION.

2. The LMS100 has been evaluated as an Installation (Overvoltage) Category 1 / Pollution Degree 2 apparatus per IEC 1010.

3. The maximum altitude of operation is 6560 feet (2000 meters).

4. The LMS100 is designed with both internal and external protective earth (ground) terminals.

5. Housing and cover are made from 316L SS. Assess material suitability for the target environment before deploying.

6. Additional flamepath information available upon request.

7. Product label may be susceptible to electrostatic charge buildup in Group III environments. Care should be taken to prevent the buildup of electrostatic charge. Clean only with a damp cloth

8. Do not torque any attached conduits, thread adapters, reducers, elbows, or cable glands beyond the manu-facturer’s recommended installation torque. Torque requirements for the LMS100’s optional thread adapters are listed below.

Option DescriptionRecommended

Torque

U8 M20 adapter 316 SS 32.5 Nm

E81/2 inch by 1/2 inch

NPT elbow35 Nm

E91/2 inch NPT by M20

elbow35 Nm

5.2.2 Nameplate Marking Procedure (Declaration of Protec-tion Concept)Before installing the switch, permanently indicate the protec-tion concept associated with the hazardous area by marking the corresponding box on the product label. Only one box shall be marked. The chosen protection concept cannot be altered and shall govern the use of the product until end of life. If more than one protection concept is marked, the switch must be removed from the hazardous area immediately.

FM/FM-C Name Plate

1234

A

B

C

D

1234

A

B

C

D

The information contained herein isproprietary to and considered a tradesecret of ABB Inc., and shall not be

reproduced, in whole orin part, without the written authorization

of ABB Inc.

Lang.:

Prepared by:

Title:

Part No.:

Doc. Type: Date:

Rev.:

Sheet:Drawing No.:

Approved by:

PA/MP/LMResp.

K-TEK PRODUCTS18321 SWAMP ROAD

PRAIRIEVILLE, LA. 70769 USA

EN

LMS100 FM/FM-CNAMEPLATE

Norman W Guidry Eric Fauveau

08/05/14

3KXL000391U0200 3KXL000391U0209

-

ARTWORK DRAWING

1 of 1

REV DESCRIPTION APPROVED DATE

- ECN0915 E.F. -

CRITICAL / SCHEDULE DOCUMENTNO MODIFICATION PERMITTED WITHOUT APPROVAL

FROM AGENCY / NOTIFIED BODYNOTES:1. LABEL MATERIAL: - SUBSTRATE LAYER: BRADY B-428 - OVERLAMINATE LAYER: BRADY B-111 - ADHESIVE LAYERS: HIGH PERFORMANCE ACRYLIC2. LABEL TEMP. RANGE: -40°C TO 150°C (OUTDOOR)3. LABEL MUST BE RESISTANT TO OCCASIONAL EXPOSURE TO

PETROLEUM SOLVENTS.4. REFER TO 3KXL000391U0018 FOR MARKING PROCEDURE.5. DIMENSIONS ARE IN INCHES [MM].

SUBSTRATE LAYERADHESIVE LAYER

ADHESIVE LAYEROVERLAMINATE LAYER

3KXL000391U0200 LAYERS

3KXL000460U0100

3KXL000461U0100

PRO

DE

3KXl

!

L

4.000

.700K-TEK PRODUCTS

250V MAX1A MAX

60VA MAX(NON-IS/NI)

TYPE 4X; NO ACIDIC ATMOSPHERES / AUCUN ATMOSPHERES ACIDES; IS / NIPER CONTROL DWG 3KXL130100G0022; CONDUIT SEAL REQUIRED WITHIN2 IN / SCELLEMENT EXIGE SUR CONDUIT A 50 MM; -40°C ≤TA≤70°C

CLII DIV2 GP EFG T6; CLIII T6CLI Zn2 AEx nC IIC T6...T1Ex nC IIC T6...T1 Gc

NI: CLI DIV2 GP ABCD T6CLII GP EFG T6; CLIII T6CLI Zn1 AEx d IIC T6...T1Ex d IIC T6...T1 GbZn21 AEx tb IIIC T85°C...T450°C

XP: CLI GP ABCD T6CLII GP EFG T6; CLIII T6CLI Zn0 AEx ia IIC T6...T1Ex ia IIC T6...T1 GaZn20 AEx ia IIIC T85°C...T450°C

IS: CLI GP ABCD T6

FM

APPROVEDC US

MADE IN USA

LMS100.XX.XX.XX.XXSN: 3K650000000000MAGNETIC SWITCH

SEE MANUALOI/LMS100

!!

K-TEK PRODUCTS

250V MAX1A MAX

60VA MAX(NON-IS/NI)

TYPE 4X; NO ACIDIC ATMOSPHERES / AUCUN ATMOSPHERES ACIDES; IS / NIPER CONTROL DWG 3KXL130100G0022; CONDUIT SEAL REQUIRED WITHIN2 IN / SCELLEMENT EXIGE SUR CONDUIT A 50 MM; -40°C ≤TA≤70°C

CLII DIV2 GP EFG T6; CLIII T6CLI Zn2 AEx nC IIC T6...T1Ex nC IIC T6...T1 Gc

NI: CLI DIV2 GP ABCD T6CLII GP EFG T6; CLIII T6CLI Zn1 AEx d IIC T6...T1Ex d IIC T6...T1 GbZn21 AEx tb IIIC T85°C...T450°C

XP: CLI GP ABCD T6CLII GP EFG T6; CLIII T6CLI Zn0 AEx ia IIC T6...T1Ex ia IIC T6...T1 GaZn20 AEx ia IIIC T85°C...T450°C

IS: CLI GP ABCD T6

FM

APPROVEDC US

MADE IN USA

LMS100.XX.XX.XX.XXSN: 3K650000000000MAGNETIC SWITCH

SEE MANUALOI/LMS100

!!

ATEX/IECEx Name Plate

1234

A

B

C

D

1234

A

B

C

D

The information contained herein isproprietary to and considered a tradesecret of ABB Inc., and shall not be

reproduced, in whole orin part, without the written authorization

of ABB Inc.

Lang.:

Prepared by:

Title:

Part No.:

Doc. Type: Date:

Rev.:

Sheet:Drawing No.:

Approved by:

PA/MP/LMResp.

K-TEK PRODUCTS18321 SWAMP ROAD

PRAIRIEVILLE, LA. 70769 USA

EN

LMS100 ATEX/IECExNAMEPLATE DRAWING

Norman W Guidry Eric Fauveau

08/05/14

3KXL000391U0100 3KXL000391U0109

-

ARTWORK DRAWING

1 of 1

REV DESCRIPTION APPROVED DATE

- ECN0915 E.F. -

CRITICAL / SCHEDULE DOCUMENTNO MODIFICATION PERMITTED WITHOUT APPROVAL

FROM AGENCY / NOTIFIED BODY

.700 [17.8]

4.00 [101.6]

SUBSTRATE LAYERADHESIVE LAYER

ADHESIVE LAYEROVERLAMINATE LAYER

3KXL000391U0100 LAYERS

3KXL000460U0100

3KXL000461U0100

PRO

DE

3KXl

!

L

NOTES:1. LABEL MATERIAL: - SUBSTRATE LAYER: BRADY B-428 - OVERLAMINATE LAYER: BRADY B-111 - ADHESIVE LAYERS: HIGH PERFORMANCE ACRYLIC2. LABEL TEMP. RANGE: -40°C TO 150°C (OUTDOOR)3. LABEL MUST BE RESISTANT TO OCCASIONAL EXPOSURE TO

PETROLEUM SOLVENTS.4. REFER TO 3KXL000391U0018 FOR MARKING PROCEDURE.5. DIMENSIONS ARE IN INCHES [MM].

MADE IN USA

IP66/IP67-40°C≤TA≤70°C

II 2 G, Ex d IIC T6...T1 GbII 2 D, Ex tb IIIC T85°C...T450°C DbFM14ATEX0029X, IECEx FMG 14.0015XII 1 G, Ex ia IIC T6...T1 GaII 1 D, Ex ia IIIC T85°C...T450°C DaFM14ATEX0030X, IECEx FMG 14.0015XII 3 G, Ex nC IIC T6...T1 GcFM14ATEX0031X, IECEx FMG 14.0015X

SEE MANUALOI/LMS100

!!

LMS100.XX.XX.XX.XXSN: 3K650000000000MAGNETIC SWITCH

0575

250V MAX1A MAX

60VA MAX(NON-IS/NI)

K-TEK PRODUCTS

MADE IN USA

IP66/IP67-40°C≤TA≤70°C

II 2 G, Ex d IIC T6...T1 GbII 2 D, Ex tb IIIC T85°C...T450°C DbFM14ATEX0029X, IECEx FMG 14.0015XII 1 G, Ex ia IIC T6...T1 GaII 1 D, Ex ia IIIC T85°C...T450°C DaFM14ATEX0030X, IECEx FMG 14.0015XII 3 G, Ex nC IIC T6...T1 GcFM14ATEX0031X, IECEx FMG 14.0015X

SEE MANUALOI/LMS100

!!

LMS100.XX.XX.XX.XXSN: 3K650000000000MAGNETIC SWITCH

0575

250V MAX1A MAX

60VA MAX(NON-IS/NI)

K-TEK PRODUCTS

Page 7: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch 7

5.2.3 Flame Proof / Explosion Proof Installation Requirements (Ex d):

The LMS100 is designed for use in Zone 1 / Division 1 hazardous areas.

Installation and use of apparatus in hazardous locations shall be in accordance with an IEC 60079-14 or applicable regional standard.

If conduit is used in the installation, an approved conduit seal or stopping box is required immediately after (ATEX/IECCEx) or within 18 inches of (FM/FM-C/CSA) the end-use field wiring entrace.

Internal temperatures of the LMS100 can reach up to 257°F (125°C) when operated at maximum process and maximum ambient temperatures. The service temperature range of cable glands and field wiring shall be chosen accordingly.

Temperature classifications of the LMS100 are dependent on the temperature of the coupled process vessel. Use the table below to determine temperature class:

Maximum Process Temperature Temperature Class

-40°F (-40°C) ≤ T ≤ 167°F (75°C) T6

167°F (75°C) < T ≤ 194°F (90°C) T5

194°F (90°C) < T ≤ 257°F (125°C) T4

257°F (125°C) < T ≤ 374°F (190°C) T3

374°F (190°C) < T ≤ 554°F (290°C) T2

554°F (290°C) < T ≤ 780°F (416°C) T1

5.2.4 Protection by EnclosureInstallation Requirements (Ex tb):

Field wiring fittings such as cable glands and conduit must main-tain the ingress protection rating of the enclosure (IP6X).

Not suitable for use in uncontrolled dust environments.

Temperature classification of the LMS100 is related to process temperature. The temperature class of the LMS100 can be deter-mined by using the relationship below:

Max Process Temp Temperature Class

176 °F (80 °C) 185 °F (85 °C)

203 °F (95 °C) 212 °F (100 °C)

266 °F (130 °C) 275 °F (135 °C)

383 °F (195 °C) 392 °F (200 °C)

563 °F (295 °C) 581 °F (305 °C)

780.8 °F (416 °C) 798.8 °F (426 °C)

Temperature Class vs. Process Temperature

TCLASS = TPROCESS + 10°C,when TPROCESS > 200°C

TCLASS = TPROCESS + 5°C,when TPROCESS > 70°C

TCLASS = 75°C, whenTPROCESS ≤ 70°C

450

400

350

250

200

150

100

50

0

Tem

per

atur

e C

lass

(°C

)Process Temperature (°C)

-100 -50 0 50 100 150 200 250 300 350 400 450

Page 8: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

8 OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch

5.2.5 Intrinsic Safety / Non-Incendive Requirements

AM

BIE

NT

TEM

PERATU

RE

RAN

GE: -

40°

C ≤

Ta ≤ +

70 °

CCLI

DIV

1 GP

ABC

D T

6; C

LII D

IV1

GP

EFG T

6; C

LIII

T6CLI

DIV

2 GP

ABC

D T

6; C

LII D

IV2

GP

EFG T

6; C

LIII

T6

(NO

TES

3, 5

, 9)

(NO

TES

3, 5

, 9)

LMS

100

SW

ITC

H (N

OTE

S 1

, 2, 8

)

NC

NO

C

GR

OU

ND

I.S.

CU

STO

ME

R W

IRIN

G

NO

N-H

AZARD

OUS

AREA

12

34

ABCD

12

34

ABCD

The

inf

orm

atio

n co

ntai

ned

here

in is

pro

prie

tary

to

and

cons

ider

ed a

tra

dese

cret

of A

BB

Inc

., an

d sh

all n

ot b

ere

pro

duce

d, in

who

le o

rin

par

t, w

ithou

t th

e w

ritte

n au

thor

izat

ion

of

AB

B In

c.

Lang

.

Pre

par

ed b

y

Titl

e:

Par

t No.

Do

c. T

ype:

Dat

e

Rev

.

She

etD

raw

ing

No.

Ap

pro

ved

by

PA

/MP

/LM

Res

p.

K-T

EK

PR

OD

UC

TS18

321

SW

AM

P R

OA

DP

RA

IRIE

VIL

LE, L

A. 7

0769

US

A

EN

LMS

100

IS/N

I CO

NTR

OL

DR

AW

ING

US

JOJE

NU

SE

RFA

U

10/2

4/14

N/A

3KX

L130

100G

0122

-

CE

RTI

FIC

ATI

ON

SC

HE

MA

TIC

1 of

1

HAZARD

OUS

AREA

Ex ia

IIC T

6...T

1 Ga

Ex ia

IIIC T

85°C

...45

0°C D

aEx

nC IIC

T6.

..T1

Gc

RE

VD

ES

CR

IPTI

ON

AP

PR

OV

ED

DA

TE

NC

EC

N09

15E

.F.

10/2

4/14

(NO

TES

3, 4

)

CLI

Zn0

AEx

ia

IIC T

6...T

1; E

x ia

IIC

T6.

..T1

Ga

Zn2

0 AEx

ia

IIIC T

85°C

...T4

50°C

CLI

Zn2

AEx

nC IIC

T6.

..T1;

Ex

nC IIC

T6.

..T1

Gc

NO

TE

S 6

NO

TE

S 6

AP

PR

OV

ED

SIN

GLE

OR

MU

LTIP

LE C

HA

NN

EL

ZE

NE

R B

AR

RIE

R(N

OTE

S 2

, 6, 7

)

0575

II 1

GII

1 D

II 3

G

GE

NE

RA

L N

OTE

S1.

SW

ITC

H I.

S. E

NTI

TY P

AR

AM

ETE

RS

: Ui:

60 V

, Ii:

1 A

, Ci:

0μF

, Li

: 0 m

H (N

OTE

: FIE

LD W

IRE

SM

US

T Q

UA

LIF

Y A

S S

EP

AR

AT

E IN

TRIN

SIC

ALL

Y S

AFE

CIR

CU

ITS

OR

BE

CO

NS

TRU

CTE

DFR

OM

SH

IELD

ED

INS

UL

ATI

ON

WIT

H >

0.50

MM

RA

DIA

L W

ALL

TH

ICK

NE

SS

)2.

ALT

ER

NA

TE S

WIT

CH

I.S

. IN

PU

T P

AR

AM

ETE

RS

:

U

i = 1

4 V

,

Ii =

120

0 m

A,

Pi =

4.2

0 W

Ui =

30

V,

Ii =

101

mA

,

Pi =

757

mW

Ui =

18

V,

Ii =

440

mA

,P

i = 1

.98

WU

i = 6

0 V

, Ii

= 2

9 m

A,

P

i = 4

35 m

WU

i = 2

4 V

, I

i = 1

74 m

A,

Pi =

1.0

44 W

3.

I.S. S

WIT

CH

CO

NTA

CTS

SH

ALL

NO

T B

E U

SE

D U

NLE

SS

CO

NN

EC

TED

TO

AN

AP

PR

OVE

DS

AF

ET

Y B

AR

RIE

R4.

AN

Y U

NU

SE

D S

WIT

CH

CO

NTA

CTS

MU

ST

BE

ELE

CTR

ICA

LLY

ISO

LATE

D.

5.

IN U

SE

I.S

. SW

ITC

H C

ON

TAC

TS M

US

T S

HA

RE

TH

E S

AM

E S

AFE

TY B

AR

RIE

R C

HA

NN

EL.

6. V

OLT

AG

E A

PP

LIE

D T

O O

R S

UP

PLI

ED

BY

AS

SO

CIA

TED

AP

PA

RA

TUS

MU

ST

NO

T E

XC

EE

D2

50 V

.7.

PA

RA

LLE

L O

R S

ER

IES

OF

CO

MB

INA

TIO

N O

F S

AFE

TY B

AR

RIE

R O

UTP

UT

TER

MIN

ALS

ISN

OT

PE

RM

ITTE

D.

8. W

AR

NIN

G:

SU

BS

TITU

TIO

N O

F C

OM

PO

NE

NTS

MA

Y IM

PA

IR S

UIT

AB

ILIT

Y F

OR

US

E IN

HA

ZA

RD

OU

S L

OC

AT

ION

S.

AV

ER

TIS

SE

ME

NT:

LA

SU

BS

TITU

TIO

N D

E C

OM

PO

SA

NTS

PEU

TR

EN

DR

E C

E M

ATE

RIE

L IN

AC

CE

PTA

BL

E P

OU

R L

ES

EM

PLA

CE

MEN

TS D

AN

GER

EU

X.

9. W

AR

NIN

G: E

XP

LOS

ION

HA

ZA

RD

- D

O N

OT

DIS

CO

NN

EC

T E

QU

IPM

EN

T U

NLE

SS

PO

WER

HA

S B

EE

N S

WIT

CH

ED

OFF

OR

TH

E A

RE

A I

S K

NO

WN

TO

BE

NO

N-H

AZ

AR

DO

US

/A

VE

RTI

SS

EM

EN

T: R

ISQ

UE

D'E

XP

LOS

ION

- A

VA

NT

DE

DIS

CO

NN

EC

TER

L'E

QU

IPM

EN

T,C

OU

PE

R L

E C

OU

RA

NT

OU

S'A

SS

UR

ER

QU

E L

'EM

PLA

CEM

EN

T ES

T D

ES

IGN

E N

ON

DA

NG

ER

EU

X.

CR

ITIC

AL

/ SC

HED

ULE

DO

CU

MEN

TN

O M

OD

IFIC

ATI

ON

PER

MIT

TED W

ITH

OUT

APP

RO

VAL

FRO

M A

GEN

CY

/ N

OTI

FIED

BO

DY

NO

TE

S R

ELA

TED

TO

FM

/FM

-C A

PP

RO

VAL:

·S

WIT

CH

CO

NFO

RM

S T

O F

M A

PP

RO

VA

L S

TAN

DA

RD

361

0.·

INS

TALL

IN A

CC

OR

DA

NC

E W

ITH

AN

SI/

ISA

RP

12.6

AN

D A

NS

I/NFP

A 7

0S

EC

TIO

NS

504

AN

D 5

05.

·U

SE

OF

AN

AP

PR

OV

ED

SA

FETY

BA

RR

IER

NO

T R

EQ

UIR

ED

INN

ON

-IN

CE

ND

IVE

(DIV

ISIO

N 2

) AP

PLI

CA

TIO

NS

IF S

WIT

CH

IS IN

STA

LLED

PE

R N

AT

ION

AL

EL

EC

TRIC

AL

CO

DE

DIV

ISIO

N 2

WIR

ING

ME

THO

DS

AS

SO

CIA

TED

EQ

UIP

ME

NT

MU

ST

BE

FM

AP

PR

OVE

D.

SE

E T

HE

FO

LLO

WIN

G D

OC

UM

EN

TS F

OR

MO

RE

INFO

RM

ATI

ON

:D

S/L

MS

100

-EN

: D

ATA

SH

EE

TO

I/LM

S1

00-E

N:

OP

ER

ATI

NG

INS

TRU

CTI

ON

MA

NU

AL

NO

TE

S R

EL

AT

ED

TO

CS

A A

PP

RO

VAL

US

E O

F A

N A

PP

RO

VE

D S

AFE

TY B

AR

RIE

R N

OT

RE

QU

IRE

D IN

NO

N-I

NC

EN

DIV

E (D

IVIS

ION

2) A

PP

LIC

ATI

ON

S IF

SW

ITC

H IS

INS

TALL

EDP

ER

CA

NA

DIA

N E

LEC

TRIC

AL

CO

DE

PA

RT

1 (C

22.1

) D

IVIS

ION

2 W

IRIN

GM

ET

HO

DS

INS

TALL

AT

ION

SH

AL

L C

ON

FO

RM

TO

PA

RT

I OF

THE

CA

NA

DIA

NE

LEC

TRIC

AL

CO

DE

AN

D T

O T

HE

INS

TRU

CTI

ON

S S

UP

PLI

ED

WIT

HA

SS

OC

IATE

D E

QU

IPM

EN

T.·

AS

SO

CIA

TED

EQ

UIP

ME

NT

MU

ST

BE

CS

A A

PP

RO

VE

D.

NO

TES

RE

LATE

D T

O A

TEX

/IEC

AP

PR

OV

AL

INS

TALL

AT

ION

AN

D U

SE

OF

AP

PA

RA

TU

S I

N H

AZ

AR

DO

US

LO

CA

TIO

NS

SH

ALL

BE

INA

CC

OR

DA

NC

E W

ITH

IEC

600

79-1

4 O

R E

QU

IVA

LEN

T R

EG

ION

AL

STA

ND

AR

D.

Page 9: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch 9

5.3 Typical ApplicationsSome ABB switch products (LMS100, MS50, MS10) are based on magnetically operated reed switches. Since reed switches have the inherent characteristic of very closely spaced switch contacts, it is extremely important to protect these contacts from high voltage transients caused by inductive loads. When an inductive load is de-energized., the collapsing magnetic field induces a high voltage of opposite polarity into itself and thus the switch . Two basic methods exist to clamp this voltage and thus protect the switch contacts.

5.4 Typical D.C. ApplicationsFor D.C. applications, a diode is placed in parallel with the induc-tive load (note the polarity of the diode and power supply). A 1N4001 general purpose diode is normally sufficient to clamp the induced voltage of the inductive load to as safe level. NOTE: Not evaluated for use in hazardous locations

5.5 Typical A.C. ApplicationsFor A.C. applications, a Metal Oxide Varistor (MOV transient surge suppressor) is placed either in parallel with the switch or the inductive load. The MOV changes from a high impedance to a very low impedance when the voltage across the MOV exceeds its rated voltage (the MOV rating must correspond with the power

supply voltage). For 120 VAC control systems a typical MO would be the GE (General electric Co.) part number V130LA10A. In either case shown, the result is the limiting of the switch volt-age to approximately 130 volts. NOTE: Not evaluated for use in hazardous locations

D.C. Contact Protection

A.C. Contact Protection

DC POWER SUPPLY

INDUCTIVE LOAD DIODE

WHITE(COMMON)

BLACK OR RED(NO) (NC)

+ -

AC POWER SUPPLY

INDUCTIVE LOAD MOV

WHITE(COMMON)

BLACK OR RED(NO) (NC)

+ -

DC POWER SUPPLY

INDUCTIVE LOAD DIODE

WHITE(COMMON)

BLACK OR RED(NO) (NC)

+ -

AC POWER SUPPLY

INDUCTIVE LOAD MOV

WHITE(COMMON)

BLACK OR RED(NO) (NC)

+ -

Page 10: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

10 OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch

4) Place the included screws into the replacement core assem-bly’s mounting holes. Apply Loctite® 271 to each of the screws. Align the core assembly screws with the threaded holes in the enclosure as seen in the figure below. Tighten the screws with a precision Phillips screwdriver.

NOTE: removing the switch from the chamber and placing it on a flat surface as shown in the figure below will sim-plify the replacement process. Be sure to note and mark the exact mounting position of switch with respect to the chamber before removal.

6.0 ServiceThe LMS100 does not require any routine maintenance in normal day to day operation.

CAUTION: If there is a need to take the switch out of service or disconnect it for any reason, then make sure the circuit is de-energized or that the area is known to be non-hazardous.

The LMS100’s reed switch core assembly is field replace-able. In the event of a failure, a replacement can be ordered through an ABB sales representative by referencing part number 3KXL130100L0001.

Reed Switch Core Assembly Replacement Instructions

CAUTION! De-energize all field wiring before servicing. 1) To remove the cover, first unlock the cover security bolt located at the 5 o’clock position of the cover, by turning it clockwise with an M2.5 hex key. When the bolt head no longer touches the cover, grip the cover tightly and rotate it counterclockwise to remove.

2) Remove the terminal plug and, if possible, associated field wir-ing from the enclosure to ensure proper clearance.

3) Using a small precision Phillips screwdriver, loosen the two screws shown in the figure below. When loose, grip the core as-sembly with the thumb and index fingers. Pull outward to remove. (see figure b)

Page 11: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch 11

CAUTION! Ensure that field wiring to the device remains de-energized before proceeding.

5) Insert the terminal plug and reconnect any field wiring removed in step 2. Replace the cover and tighten fully. Be sure to lock the cover in place by turning the cover security bolt counterclockwise with an M2.5 hex key until the bolt is pressed firmly against the cover.

7.0 Replacement Parts

Page 12: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

12 OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch

8.0 Data Sheet Specifications:

Switch type Magnetically actuated, hermetically sealed, bi-stable switch.Single pole, double throw (Form C)

Contact Material Rhodium alloy

Switch Action Break before make

Max Deadband Approx. +/- 0.75 in. (1.9 cm) of float travel

Contact RatingsMaximum voltage: 250 V AC/DCMaximum current: 1 AMaximum power: 60 W/VA

Minimum operating temperature -40 °F (-40 °C) Contact factory regarding use in colder applications

Maximum operating temperature 300 °F (149 °C) For process temperatures to 800 °F (427 °C), see mounting options, below

Vibration Tested to IEC 60068-2-6 (2-2000 Hz, 2 g)

Shock Tested to IEC 60068-2-29 (10 g) and IEC 60068-2-27

Impact Tested to IEC 60079-0 (1 kg)

Freefall Test to IEC 60068-2-31 (0.5 m, 6 falls)

Hazardous Area Rating:

FM / FM-C – -40 °C ≤ TA ≤ 70 °C – IS: CLI GP ABCD T6 / CLI Zn0 AEx ia IIC T6...T1 / Ex ia IIC T6...T1 Ga / CLII GP EFG T6 /

CLIII T6 / Zn20 AEx ia IIIC T85°C...T450°C – XP: CLI GP ABCD T6 / CLI Zn1 AEx d IIC T6...T1 / Ex d IIC T6...T1 Gb / CLII GP EFG T6 /

CLIII T6 / Zn21 AEx tb IIIC T85°C...T450°C – NI: CLI DIV2 GP ABCD T6 / CLI Zn2 AEx nC IIC T6...T1 / Ex nC IIC T6...T1 Gc / CLII DIV2

GP EFG T6 / CLIII

ATEX / IECEx – -40 °C ≤ TA ≤ 70 °C – II 1 G / Ex ia IIC T6...T1 Ga – II 1 D / Ex ia IIIC T85°C...T450°C Da – II 2 G / Ex d IIC T6...T1 Gb – II 2 D, Ex tb IIIC T85°C...T450°C Db – II 3 G / Ex nC IIC T6...T1 Gc

Electrical Cable Connection 1/2 in. FNPT connection

Mounting optionsFor process temperatures to 575 °F (301.6 °C) use switch LMS100.P1 with insulation pad. For process temperatures to 800 °F (427 °C) use switch LMS100.A2 with rod mount brackets with insulated KM26 Gauges, or, on ST95 Seal Fluid Supply Tanks with rod mount brackets.

Housing 316SS, NEMA 4X IP66/IP67, Cable entry 1/2” FNPT

Application note Inductive and Capacitive loads require special considerations. Contact factory for technical literature and assistance.

Accessories IR10 10 Amp Relay Output Module and PP10 PUMP-PAK Controller. See appropriate sales literature for details.

0575

Page 13: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch 13

9.0 Ordering Information: LMS100.a.b.c.da Mounting

A1Standard, up to 300 °F (149 °C) (mounted to chamber via gear clamps)

A2

Switch rod mount up to 350 °F (176.6 °C) max process temperatures. When used with chamber insulation option,800 °F (427 °C) max process temperatures

b High temperature processes insulation options

Y0Standard, without insulation pad, up to 300 °F (149 °C) (standard gear clamp mounting)

P1Insulation pad (IH) for temperature, up to 575 °F (301.6 °C) (with standard gear clamp mounting only)

c ApprovalsY0 General Purpose, (not for hazardous locations)

N4FM / FM-C (Canada), (see applicable approval markings on page 2)

E4ATEX, IECEx, (see applicable approval markings on page 2)

d Electrical cable connectionA1 Standard 1/2 inch FNPT

U8M20 adapter 316 SS, ATEX, IEC, CSA, Ex approved

E81/2 inch by 1/2 inch NPT elbow for cyrogenic insulation applications, ATEX, IEC, CSA, Ex approved

E91/2 inch NPT by M20 elbow for cyrogenic insulation applications, ATEX, IEC, CSA, Ex approved

Accessories ordered separatelyAR1 10 A relay output module (IR10)

AR2 Pump pack controller (PP10)

OperationThe LMS100 consists of a form C reed switch actuated by a rotating permanent magnet. The reed switch uses precious metal contacts in an inert gas atmosphere sealed by glass to metal bond. A magnetic float traveling in a chamber, relative to the LMS100 causes the reed switch to change state. After the float has passed, the reed switch will maintain it’s state until the float reverses direction and passes the switch in the opposite direction. The action of the switch is break before make. The hermetically sealed contacts serve to insure a high degree of hazardous area safety, weather resistance and general reliability of the product.

ApplicationThe LMS100 will provide either a normally open or normally closed dry contact which may be used to activate external devices such as alarms or annunciator. Its main application is to sense the passing of a magnetic float in a KM26 level gauge, or similar chamber, attached to a vessel containing a fluid. These trip points can be used for alarms to activate a pump motor starter relay.

MountingThe LMS100 is mounted using two stainless steel clamps that pass behind the housing’s integrated mounting tabs. The switch can be easily positioned by loosening the clamp and sliding the switch to the correct position on the chamber. Other switches can be added at any time, without the concern for additional process piping or valves. Note that two switches can be mounted so that they can trip at the same point or at two points separated by more than the height of the switch.

CN.C.

N.O.

LMS100: Float Below Switch

CN.O.

N.C.

LMS100: Float Above Switch

Figure 1: Contact closure shown for both condi-tions of the switch relative to the magnetic float.

Page 14: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

14 OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch

10.0 Warranty Statement

5 YEAR WARRANTY FOR: KM26 Magnetic Liquid Level Gauges; MagWave Dual Chamber System; LS Series Mechanical Level Switches (LS500, LS550, LS600, LS700, LS800 & LS900); EC External Chambers, STW Stilling Wells and ST95 Seal Pots.

3 YEAR WARRANTY FOR: KCAP300 & KCAP400 capacitance switches. BETA Pressure and Temperature Switches have a limited factory guarantee, excluding wetted parts & consumables.

2 YEAR WARRANTY FOR: AT100, AT100S and AT200 series transmitters; RS80 and RS85 liquid vibrating fork switches; RLT100 and RLT200 reed switch level transmitters; TX, TS, TQ, IX and IM thermal dispersion switches; IR10 and PP10 External Relays; MT2000, MT5000, MT5100 and MT5200 radar level transmitters; RI100 Repeat Indicators; KP paddle switches; A02, A75 & A77 RF capacitance level switches and A38 RF capacitance level transmitters; Buoy-ancy Level Switches (MS50, MS10, MS8D & MS8F); Magnetic Level Switches (LMS100, MS40, MS41, PS35 & PS45).

1 YEAR WARRANTY FOR: KM50 gauging device; AT500 and AT600 series transmitters; La-serMeter and SureShot series laser transmitters; LPM200 digital indicator; DPM100 digital indicators; APM100 analog indicators; KVIEW series digital indicators and controllers; SF50 and SF60 vibrating fork switches, KB Electro-Mechanical Continuous Mea-suring Devices, KSONIK ultrasonic level switches, transmitters & transducers, ChuteMaster Microwave Transmitter / Receiver and TiltMaster Switches.

SPECIAL WARRANTY CONSIDERATIONS: ABB does not honor OEM warranties for items not manufac-tured by ABB (i.e. Palm Pilots). These claims should be handled directly with the OEM.

ABB will repair or replace, at ABB’s election, defective items which are returned to ABB by the original purchaser within the period specified above from the shipment date of the item and which is found, upon examination by ABB, to its satisfaction, to contain defects in materials or workmanship which arose only under normal use and service and which were not the result of either alterations, misuse, abuse, improper or inadequate adjust-ments, applications or servicing of the product. ABB’s warranty does not include onsite repair or services. Field service rates can be supplied on request.

If a product is believed to be defective, the original purchaser shall notify ABB and request a Returned Material Authorization before returning the material to ABB, with transportation prepaid by the purchaser. (To expedite all returns/repairs from outside of the United States, consult ABB’s customer service team ([email protected]) to determine an optimal solution for shipping method and turnaround time.) The product, with repaired or replaced parts, shall be returned to the purchaser at any point in the world with transportation prepaid by ABB for best-way trans-portation only. ABB is not responsible for expedited shipping charges. If the product is shipped to ABB freight collect, then it will be returned to the customer freight collect.

If inspection by ABB does not disclose any defects in material or workmanship, ABB’s normal charges for repair and shipment shall apply (minimum 250.00 USD).

The materials of construction for all ABB products are clearly specified and it is the responsibility of the purchaser to determine the compatibility of the materials for the application.

THE FOREGOING WARRANTY IS ABB’S SOLE WARRANTY AND ALL OTHER WARRANTIES EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OF MER-CHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE, ARE EXCLUDED AND NEGATED TO THE MAXIMUM EXTENT PERMITTED BY LAW. NO PERSON OR REPRESENTATIVE IS AUTHORIZED TO EXTEND ANY OTHER WARRANTY OR CRE-ATE FOR ABB ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ABB’S PRODUCTS. THE REMEDIES SET FORTH IN THIS WARRANTY ARE EXCLUSIVE OF ALL OTHER REM-EDIES AGAINST ABB. ABB SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR SPECIAL DAMAGES OF ANY KIND. ABB’S SOLE OBLIGATION SHALL BE TO REPAIR OR REPLACE PARTS (FOUND TO BE DEFECTIVE IN MATERI-ALS OR WORKMANSHIP) WHICH ARE RETURNED BY THE PURCHASER TO ABB.

Page 15: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

OI/LMS100-EN Rev. A | LMS100 Magnetic Level Gauge Switch 15

11.0 RMA Form

ABB US18321 Swamp RoadPrairieville, LA 70769Phone: +1 (225) 673-6100 Fax: +1 (225) 673-2525 Email: [email protected] Free: (800) 735-5835

*** IMPORTANT CUSTOMER NOTICE: PLEASE READ PRIOR TO RETURNING PRODUCTS TO ABB***

Be sure to include the Return Authorization (RA) number on the shipping label or package to the attention: Customer Service. A copy of this document should also be included with the packing list. ABB wants to maintain a safe work environment for its employees. In the event, the returned product or material has been in contact with a potentially hazardous chemical, per fed-eral regulations, the customer must provide evidence of decontamination and the related chemical composition and character-istics. In order to expedite your return, please include the applicable Material Safety Data Sheets (MSDS) and decontamination tagsbyaffixingthesedocumentsincloseproximitytotheshipmentlabelforidentificationpurposes.(January18,2006)

Return Authorization Form

Customer: Date:

Contact Name: Product:

Contact Email: Serial No:

Contact Phone: Job No:

Contact Fax: Service Rep:

Completed by Customer

Reason

Problem Found: None

Action: NoneRequested:Is expedited return shipping requested? YesIf yes, please provide a purchase order or your shipper’s account number (ex. FedEx or UPS). ABB pays return transport via standard ground shipments only.

If purchase order is issued, a copy of purchase order must be included with return documentation.Is ABB authorized to repair items determined to be non-warranty? Yes If yes, a copy of purchase order must be included with return documentation. Account #:

Customer PO: Date:

Has product been in contact with any potentially hazardous chemical? YesIf yes, documentation product and forward MSDS to ABB, “ATTN: Customer Service”

Return Repaired Product to Address

Shipping Address: Billing Address:

Ship Via:

Page 16: Magnetic level gauge switch KTEK products Measurement made ... · LMS100 Magnetic level gauge switch Operating Instruction Manual OI/LMS100-EN Rev. A KTEK products Measurement made

OI/

LMS

100-

EN

Rev

. A

12

.201

4

Contact us

ABB Inc. 18321 Swamp RoadPrairieville, LA 70769 USAPhone: +1 225 673 6100Service: +1 225 677 5836Fax: +1 225 673 2525E-mail: [email protected] e-mail: [email protected]

ABB Inc.585, Boulevard Charest E., Suite 300Quebec, QC Canada G1K 9H4Phone: +1 418 877 2944Service: +1 800 858 3847Fax: +1 418 877 2834E-mail: [email protected] e-mail: [email protected]

ABB Engineering (Shanghai) Ltd.No. 5, Lane 369, Chuangye RoadKangqiao Town, Pudong District Shanghai, 201319, P.R. ChinaPhone: +86 10 64231407Service: +86 21 61056421Fax: +86 10 64371913E-mail: [email protected] e-mail: [email protected]

ABB LimitedSalterbeck Trading EstateWorkington, Cumbria, England CA14 5DSPhone: +44 7885333752Service: +44 145 3826661E-mail: [email protected] e-mail: [email protected]

www.abb.com/level

NoteWe reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreedparticulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.

We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts – is forbidden without prior written consent of ABB.

Copyright© 2014 ABBAll rights reserved

3KXL130100R4201

Sales

Service