8
COMMERCIAL CONTROL VALVES Magnum ® Control Valve

Magnum Control Valve · 2019. 3. 29. · COMMERCIAL CONTROL VALVES Magnum ® Control Valve Logix™ Series • All-electronic control platform • 24-hour super-capacitor backup –

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

  • COMMERCIAL CONTROL VALVES

    Magnum® Control Valve

  • COMMERCIAL CONTROL VALVES

    Magnum® Control Valve

    Logix™ Series • All-electronic control platform• 24-hour super-capacitor backup – no battery necessary• Remote mount kit allows programming module to be installed up to 40 feet away• Universal controller – works on all Autotrol® brand valves• Automatic capacity calculations – no math or salt tables necessary• 12-volt operation

    742 Time Clock• Simple, economic electronic time clock (chronometric)• 7- or 99-day regeneration settings• Filter or conditioner setting in one control• Fully programmable cycle times• Salt setting in 1-pound increments (lbs/cu ft)• Single controller operates Autotrol 255, 263, 268, 278 models, and

    Pentair Water Magnum and Magnum IT with one controller

    762 Demand• Simple, economic electronic demand (volumetric)• Calendar override – 99 day• 28-day variable reserve• Filter or conditioner setting in one controller• Automatic capacity calculations• Fully programmable cycle times• Salt setting in 1-pound increments (lbs/cu ft)• Operates 255, 263, 268, 278, and Magnum IT with one controller

    764 DemandSame features as the 762, plus:• Multi-tank applications (twin alternating, multi-tank parallel)• Control lockout• Remote regeneration

    Controller OptionsThe Pentair Water® Magnum Control Valve is one of the most versatile valves on the market.

    The Logix series offers the ultimate in control for the Magnum® valve. Simple 3-step programming and installation makes this electronic controller the industry leader.

  • Flow Rates (Valve Only)Service @ 15 psi (1.03 bar) drop 76 gpm (17.3 m3/hr)Backwash @ 25 psi (1.72 bar) drop 89 gpm (20.2 m3/hr)Service Cv = 19.5 (Kv = 17)Backwash Cv = 17.8 (Kv = 19.9)

    Valve Connections/DimensionsTank Thread 4-inch 8 UNInlet/Outlet 2-inch: connections NPT or BSPT, Female, CPVCBrine Line 3/4-inch NPTDrain Line* 1-1/2-inch: connections for NPT or BSPT, Female, CPVCRiser Tube Diameter 1-1/2-inchRiser Installation Above top of tank 5/8-inch (±1/8-inch)Pilot Drain and Auxiliary Hydraulic Output 1/4-inch tube fitting

    * Valve installed drain flow controls available (5 – 40 gpm). If higher backwash flow is needed, an external flow control will be required.

    Design Specifications/RatingsValve Body ThermoplasticO-rings EPDMInjector 7 sizes available: 14, 16, 18, 21, 24, 30, 36Working Pressure 25 psi – 100 psi (1.72 bar – 6.9 bar)Water Temperature 35° – 100°F (2° – 38°C), 120°F (49°C) Ambient

    OptionsTop Mount or Side Mount Configuration

    Electrical Specifications Controller Operating Voltage 12 Volt – AC (Requires a transformer supplied by GE)

    Input Supply Frequency 50 or 60 Hz (Controller configuration dependent)

    Motor Input Voltage 12 Volt – AC

    Control System Power Consumption 3 Watts average

    Transformer Specifications – All Controllers All Controllers require the use of a Pentair Water supplied transformer.

    Transformer Output Voltage 12 Volt – AC 400mA

    Transformer Input Options 115 Volt – AC 50/60 Hz; 230 Volt – AC 50/60 Hz; 100 Volt – AC 50/60 Hz

    Transformer Plug Options Indoor North American Plug Australian Plug

    Outdoor North American United Kingdom Plug (UL Listed for outdoor use) Mainland Europe Plug Japanese Plug

    Taiwan/Korea Plug

    Additional transformers may be available – call for more information.

    Specifications

  • Injector Performance – Magnum

    COMMERCIAL CONTROL VALVES

    Magnum® Control Valve

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    m3/hr gpm

    14.0

    12.0

    10.0

    8.0

    6.0

    4.0

    2.0

    0.0

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    0.60

    0.50

    0.40

    0.30

    0.20

    0.10

    0.00

    m3/hr gpm

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    0.80

    0.70

    0.60

    0.50

    0.40

    0.30

    0.20

    0.10

    0.00

    m3/hr gpm

    3.50

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    1.40

    1.20

    1.00

    0.80

    0.60

    0.40

    0.20

    0.00

    m3/hr gpm

    7.00

    6.00

    5.00

    4.00

    3.00

    2.00

    1.00

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    1.00

    0.80

    0.60

    0.40

    0.20

    0.00

    m3/hr gpm

    10.0

    8.0

    6.0

    4.0

    2.0

    0.0

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    1.00

    0.80

    0.60

    0.40

    0.20

    0.00

    m3/hr gpm

    5.00

    4.00

    3.00

    2.00

    1.00

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    0.80

    0.70

    0.60

    0.50

    0.40

    0.30

    0.20

    0.10

    0.00

    m3/hr gpm

    3.50

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    Injector 1000441For 14-inch Tanks

    Injector 1000443For 18-inch Tanks

    Injector 1000445For 24-inch Tanks

    Injector 1000446For 30-inch Tanks

    Injector 1000447For 36-inch Tanks

    Injector 1000444For 21-inch Tanks

    Injector 1000442For 16-inch Tanks

    TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

    TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

    TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

  • NOTE: Brine draw and rinse rates on empty tank.

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    m3/hr gpm

    14.0

    12.0

    10.0

    8.0

    6.0

    4.0

    2.0

    0.0

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    0.60

    0.50

    0.40

    0.30

    0.20

    0.10

    0.00

    m3/hr gpm

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    0.80

    0.70

    0.60

    0.50

    0.40

    0.30

    0.20

    0.10

    0.00

    m3/hr gpm

    3.50

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    1.40

    1.20

    1.00

    0.80

    0.60

    0.40

    0.20

    0.00

    m3/hr gpm

    7.00

    6.00

    5.00

    4.00

    3.00

    2.00

    1.00

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    1.00

    0.80

    0.60

    0.40

    0.20

    0.00

    m3/hr gpm

    10.0

    8.0

    6.0

    4.0

    2.0

    0.0

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    1.00

    0.80

    0.60

    0.40

    0.20

    0.00

    m3/hr gpm

    5.00

    4.00

    3.00

    2.00

    1.00

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    0.80

    0.70

    0.60

    0.50

    0.40

    0.30

    0.20

    0.10

    0.00

    m3/hr gpm

    3.50

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    Injector 1000441For 14-inch Tanks

    Injector 1000443For 18-inch Tanks

    Injector 1000445For 24-inch Tanks

    Injector 1000446For 30-inch Tanks

    Injector 1000447For 36-inch Tanks

    Injector 1000444For 21-inch Tanks

    Injector 1000442For 16-inch Tanks

    TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

    TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

    TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    m3/hr gpm

    14.0

    12.0

    10.0

    8.0

    6.0

    4.0

    2.0

    0.0

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    0.60

    0.50

    0.40

    0.30

    0.20

    0.10

    0.00

    m3/hr gpm

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    0.80

    0.70

    0.60

    0.50

    0.40

    0.30

    0.20

    0.10

    0.00

    m3/hr gpm

    3.50

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    1.40

    1.20

    1.00

    0.80

    0.60

    0.40

    0.20

    0.00

    m3/hr gpm

    7.00

    6.00

    5.00

    4.00

    3.00

    2.00

    1.00

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    1.00

    0.80

    0.60

    0.40

    0.20

    0.00

    m3/hr gpm

    10.0

    8.0

    6.0

    4.0

    2.0

    0.0

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    1.00

    0.80

    0.60

    0.40

    0.20

    0.00

    m3/hr gpm

    5.00

    4.00

    3.00

    2.00

    1.00

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    0.80

    0.70

    0.60

    0.50

    0.40

    0.30

    0.20

    0.10

    0.00

    m3/hr gpm

    3.50

    3.00

    2.50

    2.00

    1.50

    1.00

    0.50

    0.00

    bar

    PSI 202 3.5 5 6 7.5

    40 60 80 100 120

    Injector 1000441For 14-inch Tanks

    Injector 1000443For 18-inch Tanks

    Injector 1000445For 24-inch Tanks

    Injector 1000446For 30-inch Tanks

    Injector 1000447For 36-inch Tanks

    Injector 1000444For 21-inch Tanks

    Injector 1000442For 16-inch Tanks

    TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

    TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

    TOTAL BRINE DRAW RINSE TOTAL BRINE DRAW RINSE

  • P

    R

    E

    S

    S

    U

    R

    E

    D

    R

    O

    P

    F L O W R A T E

    MAGN

    UM C

    v BA

    CKW

    ASH

    FLO

    W

    MAGN

    UM Cv

    SERV

    ICE

    FLOW

    10 3020 40 50 60 10080 90700

    m3/h

    gpm

    0 2 4 6 8 10 12 14 16 18 20 22

    240

    220

    200

    180

    160

    140

    120

    100

    80

    60

    40

    20

    0

    bar psi

    35

    30

    25

    20

    15

    10

     5

      0

    Valve Flow Rate Characteristics

    Flow Sensor OptionsInternal Turbine UnitNormal Operating Range 2 - 80 gpm (0.45 - 18.1 m3/hr)

    Peak Operating Range 1 - 100 gpm (0.22 - 22.7 m3/hr)

    Normal Accuracy Range ±3%

    External Flow Meter – 2.0 InchNormal Operating Range* 5.0 - 225 gpm (0.50 - 51.0 m3/hr)

    Normal Accuracy Range ±3%

    Connections 2-inch: connections NPT or BSPT, Female, CPVC

    *Recommended maximum continuous duty flow rate of 2-inch turbine is 70% of maximum flow rate.

    Tank Adapter OptionsThreaded Stainless Steel 4-inch 8 UN

    Flanged Stainless Steel 6-inch

    Magnum Cv C&I Valve (1-1/2 inch inlet)

    COMMERCIAL CONTROL VALVES

    Magnum® Control Valve

  • 1-1/2-inch Magnum Cv 2-inch Magnum IT

    3.993 (10.14 cm)

    6.493 (16.5 cm)

    7.500 (19.05 cm)

    22.796 (57.90 cm)

    2.817 (7.15 cm)

    4.018 (10.20 cm)

    8.680 (22.04 cm)

    9.000 (22.86 cm)13.481 (34.24 cm)

    19.500 (49.53 cm)

    7.000 (17.78 cm)

    14.000 (35.56 cm)

    15.539 (39.47 cm)

    1.113 (2.82 cm)

    11.471 (29.13 cm)

    15.53 91.113

    11.376

    4.42 9

    13.4819.000

    9.750

    7.000 6.500

    16.250

    8.710

    3.9982.817

    27.224

    13.993 4.429

    DRAIN

    AUX.

    4.500

    4.500

    Magnum Valve Outline Dimensions

    3.993 (10.14 cm)

    6.493 (16.5 cm)

    7.500 (19.05 cm)

    22.796 (57.90 cm)

    2.817 (7.15 cm)

    4.018 (10.20 cm)

    8.680 (22.04 cm)

    9.000 (22.86 cm)13.481 (34.24 cm)

    19.500 (49.53 cm)

    7.000 (17.78 cm)

    14.000 (35.56 cm)

    15.539 (39.47 cm)

    1.113 (2.82 cm)

    11.471 (29.13 cm)

    15.53 91.113

    11.376

    4.42 9

    13.4819.000

    9.750

    7.000 6.500

    16.250

    8.710

    3.9982.817

    27.224

    13.993 4.429

    DRAIN

    AUX.

    4.500

    4.500

  • 20580 Enterprise Avenue 5730 North Glen Park Road ©2010 Pentair Residential Filtration, LLCBrookfield, WI 53045 Milwaukee, WI 53209 1017972 Rev F FE10Tel: 262.784.4490 Tel: 262.238.4400Fax: 262.784.7794 Fax: 262.238.4402