MAINTENANCE MANUALMAINTENANCE MANUALDI 16 DI 16
0.2 0.2 -- 1.6%1.6%
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Press Ctrl + L for full screen
2« click » for next step
STANDARD INSTALLATIONSTANDARD INSTALLATION
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
200 Mesh/ 80 micron filter
Union ball check/
check valve or water hammer arrestor
Inlet Outlet
Concentrate
Optional accessories:
•Pressure regulator
•Solenoid valves
•Water meter
•Flow restrictor
Optional accessories
3« click » for next step
MAIN MENUMAIN MENU• CHAPTER 1 Removing the dispenser from the installation• CHAPTER 2 Disassembling the dispenser • CHAPTER 3 Reassembling the dispenser • CHAPTER 4 Maintenance of PX piston• CHAPTER 5 Maintenance of air bleed• CHAPTER 6 Troubleshooting guide
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
« click » on the desired Chapter
or
« click » for next slide
4« click » for next step
SPECIFICATIONSSPECIFICATIONS• Injection Range:
1:500 (0.2%) to 1:64 (1.6%)1:500 (0.2%) to 1:64 (1.6%)• Water Flow Range:
0.05 to 11 GPM0.05 to 11 GPM• Operating Water Pressure:
4.3 to 85 PSI4.3 to 85 PSI• Maximum Water Temperature:
104°F 104°F –– 40°C40°C
Note: Normal safety precautions should be practiced when Note: Normal safety precautions should be practiced when working with chemicals and equipment.working with chemicals and equipment.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
5© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
« Click » to go back to the main menu
« Click » for next slide
CHAPTER 1CHAPTER 1REMOVING THE DISPENSER FROM INSTALLATIONREMOVING THE DISPENSER FROM INSTALLATION
6« click » for next step
DISASSEMBLING OF THE DISPENSER FROM THE DISASSEMBLING OF THE DISPENSER FROM THE INSTALLATIONINSTALLATION
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
After turning off the water and relieving the pressure on the unit, unscrew the dispenser inlet/outlet couplings and allow it to drain.
Unscrew the suction tube nut and remove the hose.
7© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
« Click » to go back to the main menu
« Click » for next slide
CHAPTER 2CHAPTER 2DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSER
8« click » for next step
DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSER
Unscrew middle retaining nut.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
9« click » for next step
DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSER
Pull the injection stem assembly out of the injection sleeve, and let
the solution drain out of it.
CautionCaution: Stem may be full of undiluted chemical. Be aware of
hazardous materials and take the necessary precautions for
protection.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
WATCH OUT FOR SPLASHING !WATCH OUT FOR SPLASHING !
10« click » for next step
DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSER
With the injection stem assembly in your hands, unscrew the check valve nut.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
11« click » for next step
DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Gently push the check valve out of the dosing stem with a pencil or similar object.
Do not scratch the inside of the dosing stem.
12« click » for next step
DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Separate the check valve assembly. Remove the check valve retainer with the help of small flat head screw driver. Then, remove the
cone and the spring.
13« click » for next step
DISASSEMBLING THE Y OF DISPENSERDISASSEMBLING THE Y OF DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Unscrew the bell housing and remove it.
14« click » for next step
DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Unscrew the plunger by pushing the piston down as far as possible. Use the narrow end of the suction tube nut as a
tool to unscrew the plunger.
15« click » for next step
DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Remove the piston assembly.
16« click » for next step
DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Unscrew the injection sleeve from the body of
the dispenser.
Check that the O-ring, retainer and seal are on the injection sleeve. If not, remove them from the
inside of the dispenser.
17« click » for next step
DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Remove the screen from the body, put the dispenser body on a table, hold it firmly and at the same time lift the screen with your fingers.
Remove the bell housing seal.
18« click » for next step
DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSERDisassembly of the diffuser assembly is only necessary if a leakDisassembly of the diffuser assembly is only necessary if a leak develops.develops.
Unscrew the diffuser nut.
Push the diffuser towards the interior of the dispenser. Bump it with your palm if
necessary.
Remove the diffuser assembly.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
19« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
When the disassembly of the Dosatron unit is complete, soak it in lukewarm soapy water. A soft bristled brush may be used to break residue.
Change seal kit every 12 months. Seal kit part No. EDDI002 includes: JDI012 - Top O-ring JDI011 - Top sealJDI010 - Plunger sealJDI009 - Injection stem O-ringMDI028 - Check valve springPDI032 - Check valve coneJDI011 - Check valve seal JDI012 - Check valve O-ring
CLEANING & MAINTENANCE PROCEDURECLEANING & MAINTENANCE PROCEDURE
DISASSEMBLING THE DISPENSERDISASSEMBLING THE DISPENSER
20© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
« Click » to go back to the main menu
« Click » for next slide
CHAPTER 3CHAPTER 3REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
21« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
Place the screen inside the body. Then, reseat or replace the bell
housing O-ring. Replace the O-ring if leaking.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
22« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Install the diffuser nut hand tight.
If the diffuser is leaking, replace the diffuser O-ring. Install the diffuser assembly into the body. Be sure to
align the notch in the diffuser with the tooth that is molded in the body.
23« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSERInjection AssemblyInjection Assembly
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Replace the check valve seal on the barb fitting with the
raised portion facing upward.
Replace the check valve O-ring.
24« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSERInjection AssemblyInjection Assembly
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Replace the check valve cone and spring. Insert them in the check valve guide. Then, put the check valve retainer to hold the cone and the spring in
place.
Caution: Small, spring loaded parts are easily lost!Caution: Small, spring loaded parts are easily lost!
25« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Assemble the check valve assembly by firmly pushing the guide and the barbed fitting together.
Injection AssemblyInjection Assembly
26« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
Replace the injection stem O-ring.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Injection AssemblyInjection Assembly
27« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Insert the check valve assembly into the injection stem.
Injection AssemblyInjection Assembly
Slide the middle nut on the stem and thread the check valve nut.
28« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Injection Sleeve AssemblyInjection Sleeve Assembly
Put the top seal retainer with the ridge toward the seal.
Replace the injection seal on the injection sleeve. Make sure
the raised part is facing up.
29« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Thread the injection sleeve assembly into the body of
the dispenser.
Replace the sleeve O-ring on the top of the retainer.
Injection Sleeve AssemblyInjection Sleeve Assembly
30« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Plunger AssemblyPlunger Assembly
Replace the plunger seal. Make sure not to damage the seal or plunger.
31« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Plunger AssemblyPlunger Assembly
Push the piston down as far as possible and screw the plunger onto
the plunger rod. Use the narrow end of the suction tube nut as a tool to screw the plunger all the way until it stops.
32« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
Insert the piston assembly.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
33« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
Screw the bell housing onto the body of the dispenser. It should be hand tight.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
34« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
Insert the injection stem assembly into the sleeve.
Insert the stem ring into the sleeve assembly until flush.
Align tooth on sleeve with a notch in clear adjusting nut.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
35« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Thread the middle nut onto the injection sleeve.
36« click » for next step
REASSEMBLING THE DISPENSERREASSEMBLING THE DISPENSER
The dispenser is ready to be reinstalled.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
37© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
« Click » to go back to the main menu
« click » for next step
CHAPTER 4 CHAPTER 4 MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTON
38« click » for next step
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTON
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Insert upper portion of piston into the bell housing half way down, turn the bell housing upside down and hold the smaller part of the piston ONLY, then lift it. The piston should be snug in the bell housing and the bell housing should not fall off, if it does the upper piston shell needs to be replaced. Also inspect the inside of the bell housing and look for deep vertical scratches. If this is the case, the bell housing needs to be replaced.
Piston “Fit” TestPiston “Fit” Test
39« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Insert the lower part of the piston half way down the body. Holding onto the top of the piston, let go of the body. The piston should be snug in the body, and the
body should not fall off, if it does the lower piston shell needs to
be replaced.
Also inspect the inside of the body and look for deep vertical
scratches. If this is the case, the body needs to be replaced.
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTONPiston “Fit” TestPiston “Fit” Test Note: It is best to remove the plunger (page 14) prior to Note: It is best to remove the plunger (page 14) prior to
doing this test so it will not interfere.doing this test so it will not interfere.
40« click » for next step
Remove the plunger rod. To do so, turn the nut 1/8 turn counter clockwise. Pull on nut once, then, turn again the
nut 1/8 turn counter clockwise.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTONDisassembly of pistonDisassembly of piston
41« click » for next step
Remove the upper valves by squeezing the upper area of the valve.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTONDisassembly of pistonDisassembly of piston
42« click » for next step
Unscrew the 4 screws that connect the piston rod retainer to piston shell. Remove the piston
rod retainer.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTONDisassembly of pistonDisassembly of piston
Pull out the actuator assembly
from the top.
43« click » for next step
Remove screws from outer perimeter of piston
shell.
Separate the upper piston shell from the lower piston shell.
Remove the seal between the two piston shells.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTONDisassembly of pistonDisassembly of piston
44« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTONReassembly of pistonReassembly of piston
Screw the screws from outer perimeter of piston
shell.
Put together the upper and the lower piston
shells.
Replace the seal between the two piston shells.
45« click » for next step
Insert the piston assembly into the piston shell. Make sure that the two guides are aligned with
the piston shell columns.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTONReassembly of pistonReassembly of piston
Replace the lower valves O-rings if
they are missing or deteriorating.
Replace the toggle spring.
46« click » for next step
Put together the piston rod retainer, the two feet
should face downward.
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
Install the piston rod retainer in the piston shell. Attach it with the four screws.
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTONReassembly of pistonReassembly of piston
47« click » for next step
Replace the O-rings on the upper piston valves if they are
missing or deteriorating. Insert the two upper piston
valves.© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTONReassembly of pistonReassembly of piston
The splits in the valves should line up.
48« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTONReassembly of pistonReassembly of piston
Install plunger rod in the rod retainer. The pin in the head of the rod should be aligned with the slot inside the rod retainer.
Lock it in to place by turning the lock nut clockwise 1/8 turn,
pushing it down and 1/8 turn clockwise again.
49« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF PX PISTONMAINTENANCE OF PX PISTONReset PistonReset Piston
To reset the piston, remove the bell housing, push the piston all the way down, it may click, pull the piston all the way up. Holding it in up position, push down on the vertical posts and it should click. Push the piston back down and screw the bell housing on.
50© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
« Click » to go back to the main menu
« Click » for next slide
CHAPTER 5CHAPTER 5MAINTENANCE OF AIR BLEEDMAINTENANCE OF AIR BLEED
51« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF AIR BLEEDMAINTENANCE OF AIR BLEEDDisassembly of air bleedDisassembly of air bleed
Remove the rubber cap from the top of the air bleed button.
52« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF AIR BLEEDMAINTENANCE OF AIR BLEED
Remove the ribbed collar by pulling it straight up.
Disassembly of air bleedDisassembly of air bleed
Using a small flat blade screwdriver, gently pry loose
the ribbed collar.
53« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF AIR BLEEDMAINTENANCE OF AIR BLEEDDisassembly of air bleedDisassembly of air bleed
Gently twist the air bleed button with pliers (if necessary) until the two tabs on the air bleed button align with the corresponding grooves in the bell housing.
Remove the air bleed button by pushing it through the bell housing.
54« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF AIR BLEEDMAINTENANCE OF AIR BLEEDReassembly of air bleedReassembly of air bleed
Replaced the O-ring.
The only serviceable part on the air bleed is the O-ring.
55« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF AIR BLEEDMAINTENANCE OF AIR BLEEDReassembly of air bleedReassembly of air bleed
Align the two tabs on the air bleed with the
corresponding grooves in the bell housing.
56« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF AIR BLEED
Install the air bleed button from the inside of the bell
housing. Make sure the two tabs get out of the bell
housing.Rotate the air bleed button
a quarter turn.
Reassembly of air bleedReassembly of air bleed
57« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
MAINTENANCE OF AIR BLEEDMAINTENANCE OF AIR BLEEDReassembly of air bleedReassembly of air bleed
Install the ribbed collar so that the tabs fit into the
slots in the collar.
Re-install the rubber cap on the air bleed button.
58© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002
« Click » to go back to the main menu
« Click » for next slide
CHAPTER 6 CHAPTER 6 TROUBLESHOOTING GUIDETROUBLESHOOTING GUIDE
59« click » for next step
TROUBLESHOOTINGTROUBLESHOOTING
© COPYRIGHT, DOSATRON INTERNATIONAL S.A. , 2002
Do piston “fit” test (pages 38-39). Replace piston shells, body and bell housing as necessary. Make sure your installation has a 200 mesh filter before the Dosatron.
Worn piston shells, bell housing or body
Clean the in line water filter. Clean the inside screen (see pages 17 and 21).
In-line water filter or inside screen is clogged
1. Reduce the flow rate and restart the unit slowly.2. Open bell housing, check O-rings around the four piston valves (2 at the top, 2 at the bottom) to see if they are missing or dislodged. 3. Reset the piston (see page 49 for instructions) screw bell housing back on.
Excessive water flow
PISTONPiston is not clicking
Reset piston (see page 49 for instructions) and install water hammer arrestor in the appropriate location.
Water hammer
Do piston “fit” test (pages 38-39). replace piston shells, body and bell housing as necessary. Make sure your installation has a 200 mesh filter before the Dosatron.
Scratched/scored piston shells, bell housing and/or body
Bleed out the air by pushing the air bleed button until constant flow of water comes out from around the button.
Presence of air inside the bell housing
Reset piston. See page 49 for instructions. Flip bypass to ON position if dispenser is equipped with manual bypass
Piston locked up/not clicking or bypass is in OFF position.
The arrow on the unit should point in the same direction as the water flow. Water supply and demand valve should be open.
The unit is installed in the wrong direction
REMEDYCAUSESYMPTOM
60« click » for next step
TROUBLESHOOTINGTROUBLESHOOTING
© COPYRIGHT, DOSATRON INTERNATIONAL S.A. , 2002
Clean or replace check valve parts and reassemble check valve correctly. Be sure the check valve seal is in proper position. Pages 23-25.
Check valve dirty, worn, assembled incorrectly or missing
DOSING Water flowing back into solution container.
Check suction tube connection. Inspect suction tube for pin holes or cracks.Check tightness of connection nuts.Cut ½” of top of the hose and reattach it correctly.
Air leak in the suction tube
No suction of solution
Clean or replace plunger seal.If plunger seal is missing, check incoming water pressure; refer to unit manual for specifications.
Plunger seal is damaged, swollen or missing
Clean or replace check valve parts. In particular the seal and the cone. Pages 23-25.
Check valve worn, improperly assembled, dirty or damaged
Do piston “fit” test (pages 38-39). If necessary replace piston shells, body and bell housing. Make sure your installation has a200 mesh filter before the Dosatron.
Worn piston shells, bell housing or body
Clean suction tube and strainer or replace hose assembly.Raise strainer 2” off the bottom of stock tank solution.
Suction tube or strainer clogged
Reset piston. See page 49 for instructions. Flip bypass to ON position if dispenser is equipped with manual bypass
Piston locked up/not clicking or bypass is in OFF position
REMEDYCAUSESYMPTOM
61« click » for next step
TROUBLESHOOTINGTROUBLESHOOTING
© COPYRIGHT, DOSATRON INTERNATIONAL S.A. , 2002
Do piston “fit” test (pages 38-39). If necessary replace piston shells, bell housing and/or body. Make sure your installation has a 200 mesh filter before the Dosatron.
Worn or scratched piston shells, bell housing and/or body
Check suction tube connection. Inspect suction tube for pin holes or cracks. Check tightness of connection nuts. Cut ½” off top of the hose and reattach it correctly.
Suction of air
Under-Injection
Listen to the unit clicking, count the individual clicks, should not exceed 36 clicks in 15 seconds otherwise is excessive flow. If excessive flow reduce the flow rate and restart the unit slowly.
Excessive water flow
Replace plunger seal.Worn plunger seal
Replace injection stem.Worn or cracked injection stem
Clean or replace check valve parts. In particular the seal and the cone. Pages 23-25.
Check valve worn, improperly assembled, dirty or damaged
REMEDYCAUSESYMPTOM
62« click » for next step
TROUBLESHOOTINGTROUBLESHOOTING
© COPYRIGHT, DOSATRON INTERNATIONAL S.A. , 2002
Position correctly or replace the diffuser seal.Check tightness of the nut. Pages 18 & 22.
Diffuser seal is damaged or positioned incorrectly
Position correctly or replace the diffuser if damaged. Align notch in the diffuser with tooth molded in the body. Pages 18 & 22.
Diffuser is installed incorrectly
Position correctly, clean the seal seat, or replace the bell housing seal.
Bell housing seal is damaged, positioned incorrectly or missing
Leaks between the body and the bell housing
Check and replaced the body if necessary.Body may be cracked
LEAKSLeaks in the vicinity of the black nut under the body
REMEDYCAUSESYMPTOM
63« click » for next step
© COPYRIGHT, DOSATRON INTERNATIONAL SA, 2002