Major changes in CSA O86-2014 to address mid-rise construction Y. H. Chui Professor and Director Wood Science & Technology Centre University of New Brunswick Atlantic WoodWORKS! Wood Design Seminar December 3rd, 2014 Charlottetown, PEI

Major changes in CSA O86 -2014 to address mid-rise

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Major changes in CSA O86 -2014 to address mid-rise

Major changes in CSA O86-2014 to address mid-rise construction

Y. H. ChuiProfessor and Director

Wood Science & Technology CentreUniversity of New Brunswick

Atlantic WoodWORKS! Wood Design SeminarDecember 3rd, 2014Charlottetown, PEI

Page 2: Major changes in CSA O86 -2014 to address mid-rise

Wood Science & Technology Centre

A world-renowned and nationally recognized research centre on engineered wood products and building systems

Hugh John Flemming Forestry Centre

Page 3: Major changes in CSA O86 -2014 to address mid-rise

Products R&D and testing

Floor Wall

Joist hanger & wood I-joist Steel-web beam

Page 4: Major changes in CSA O86 -2014 to address mid-rise

Research to support building codes and standards

Page 5: Major changes in CSA O86 -2014 to address mid-rise

Proposed changes on combustible construction pending final approval in March 2015

Page 6: Major changes in CSA O86 -2014 to address mid-rise

Building size limits for mid-rise combustible construction:- Upto 6 storey of residential and business occupancies- Mixed use occupancies on lower storeys

Light wood Post & Beam Cross laminated timber (CLT)

Page 7: Major changes in CSA O86 -2014 to address mid-rise
Page 8: Major changes in CSA O86 -2014 to address mid-rise
Page 9: Major changes in CSA O86 -2014 to address mid-rise
Page 10: Major changes in CSA O86 -2014 to address mid-rise
Page 11: Major changes in CSA O86 -2014 to address mid-rise
Page 12: Major changes in CSA O86 -2014 to address mid-rise

Earthquake Design:- Reduced risk of soft-storey by prohibiting Type 4

and 5 irregularity in shear wall- Increased seismic design load if natural period is

calculated by mechanics method (20%)

Page 13: Major changes in CSA O86 -2014 to address mid-rise

We will be back to pre-1953 NBCC

75 ft 1941

4 storeys 1953

6-storey or ≈ 21m proposed 2015

Page 14: Major changes in CSA O86 -2014 to address mid-rise

Structural Design:- Additional provisions in 2014 edition of CSA O86

Page 15: Major changes in CSA O86 -2014 to address mid-rise

1. Placeholder for future design provisions for CLT (2016?)

10-storey CLT building, Melbourne

Guidance documentCLT

Page 16: Major changes in CSA O86 -2014 to address mid-rise

2. Finger-jointed lumber grades

New provision permitting use of FJ MSR lumber - SPS4 ‘Fingerjoined Machine Graded Lumber (FJ-MGL)’

Page 17: Major changes in CSA O86 -2014 to address mid-rise

Special fabrication considerations for trusses

Fingerjoined lumber specifications do not require planing after joining- Offset < 1/16”

Wide Narrow

Page 18: Major changes in CSA O86 -2014 to address mid-rise

3. Size factor for glulam beams

Page 19: Major changes in CSA O86 -2014 to address mid-rise

Issue with O86-09 requirement

Large reduction in capacity for large beamsOut of date – not in

line with national and international design standards

Large testing program at UBC, including 3ft deep beams @50ft span

Page 20: Major changes in CSA O86 -2014 to address mid-rise

Impact of change on bending moment capacity

- Allows increase for shallow beams- Addresses the large reduction for large beams

0.80

0.85

0.90

0.95

1.00

1.05

1.10

1.15

1.20

0 5 10 15

Kzb

g

Span (m)

Kzbg vs span for glulam

O86-09O86-14 - d=0.3mO86-14 - d=0.6mO86-14 - d=0.9m

Page 21: Major changes in CSA O86 -2014 to address mid-rise

4. Shear resistance of glulam with an end notch

O86-09

Page 22: Major changes in CSA O86 -2014 to address mid-rise

Glulam with an end notch O86-2014 harmonizes design provisions for notched

sawn lumber and glulam members

Shear of unnotchedsection

Shear of compression side of a notched section

Fracture resistance of an end notch on tension side

Page 23: Major changes in CSA O86 -2014 to address mid-rise

5. Building movement due to shrinkage and swelling

Parallel to grain

Parallel to grain

Perpendicular to grain- Shrinkage coefficient is 40 times

0.048 inch

0.1 inch

0.048 inch

Shrinkage from 19% to 10% MC

In extreme situation (25% to 5% MC), total shrinkage ≈ 4 inches for 6-storey building Source :

b ildi i

Page 24: Major changes in CSA O86 -2014 to address mid-rise

Method of calculating shrinkage and swelling – Appendix note

Example:S = 13.75 x (25%-5%) x 0.002 = 0.55 inch

(350mm) (14mm)

Page 25: Major changes in CSA O86 -2014 to address mid-rise

6. Mechanics method for calculation capacities for shear wall and diaphragm O86-09 – Shear wall and diaphragm design strengths are given in tabular format for discrete nail size, nail spacing and sheathing thickness

Strengths were developed by testing

Page 26: Major changes in CSA O86 -2014 to address mid-rise

FFd Fd Fd

F ≈ n x Fd

where n = no of fasteners along panel edges, Fd = single nail joint capacity Other national design standards already adopted

this approach e.g. EC5, NZ, Australia

Research background

Page 27: Major changes in CSA O86 -2014 to address mid-rise

Check both fastening and panel buckling strength Check fastening

Check sheathing panel buckling (for thin sheathing)

Page 28: Major changes in CSA O86 -2014 to address mid-rise

Mid-ply shear wall

Page 29: Major changes in CSA O86 -2014 to address mid-rise

7. Deflection in mid-rise buildings (6 storeys) Deflection of a single shear wall

Stud bending

Panel shear

Nail slip

Hold-down uplift

Page 30: Major changes in CSA O86 -2014 to address mid-rise

O86-14 Annex A

Stud bending

Sheathing panel

Fastener slip

Hold-down uplift

Stacked shear wall panels

Rotation at lower storeys affects total deflection at an upper storey

Page 31: Major changes in CSA O86 -2014 to address mid-rise

Multi-storey effect Total deflection at an upper storey due to shear in panels and

fastener slip is a simple summation of interstorey deflection

Sheathing panel

Fastener slip

Page 32: Major changes in CSA O86 -2014 to address mid-rise

Multi-storey effect For bending deflection and deflection due to hold-down slip,

the rotation of wall panels needs to be considered

Stud bending

Hold-down uplift

Page 33: Major changes in CSA O86 -2014 to address mid-rise

P1

P2

P3

P4

P5

P6

Mi = overturning momentVi = shear force in shear wall(EI)i = bending stiffness of boundary member

Page 34: Major changes in CSA O86 -2014 to address mid-rise

Similar concept for deflection caused by hold-down elongation

Page 35: Major changes in CSA O86 -2014 to address mid-rise

Impact of change

Building dataSize : 9.14m x 9.14mStorey height : 3mLocation: Vancouver

Impact can be significant (≈ 50% more)

Page 36: Major changes in CSA O86 -2014 to address mid-rise

6. Fire resistance of large cross-section timber members

Light framing – faster burn-through Massive timber – slower or no burn-through

Page 37: Major changes in CSA O86 -2014 to address mid-rise

2x6 nail-laminated

Heavy timber retains structural integrity during fire

Page 38: Major changes in CSA O86 -2014 to address mid-rise

Source : FPInnovations.

2015-05-28 45

Response of wood to Fire

Although wood burns at about 220°C, it has the natural ability to form a protective layer on the surface that slows down burning

Page 39: Major changes in CSA O86 -2014 to address mid-rise

Fire Resistance Test – CLT floor

Source : FPInnovations.

Page 40: Major changes in CSA O86 -2014 to address mid-rise

Scope of Annex B

FRR of a building assembly is traditionally evaluated by testing to CAN/ULC-S101’ Standard methods of fire endurance tests of building construction and materials’

Annex B provides an engineering approach to predict FRR of wood elements exposed to the standard test, CAN/ULC-S101

Page 41: Major changes in CSA O86 -2014 to address mid-rise

New Annex B – Charring method

Fire performance of heavy timber member can be easily calculated since charring rate of wood is fairly constant ≈ 0.7mm/min

Page 42: Major changes in CSA O86 -2014 to address mid-rise

Structural design for Fire

Ufire = specified loads during fire

RfireR

Source:GHL Consultants

(Unfactored)(=1)

(mean strength)

αU = factored loads α U ≤ ϕ R

Page 43: Major changes in CSA O86 -2014 to address mid-rise

Scope of new Annex B Materials covered: sawn timber, glulam

and Structural composite lumber (SCL)

5%

50%

Page 44: Major changes in CSA O86 -2014 to address mid-rise

Charring rates for various materials

- Wall, floor

- Rectangular cross sections

Page 45: Major changes in CSA O86 -2014 to address mid-rise

Heated layer – assumed zero strength

Source : FPInnovations

Page 46: Major changes in CSA O86 -2014 to address mid-rise

Example – bending resistance of glulam

2. Calculate the char depth around the member

3. Calculate the zero strength layers and effective residual cross section, Sres

1. Assume a fire resistance rating (t in min)

Page 47: Major changes in CSA O86 -2014 to address mid-rise

Example – bending resistance of glulam4. Calculate the moment resistance of

the residual cross section, Fb,fi Sres

where Kfi =factor to convert from 5th percentile to median strength (1.35 for glulam)

6. If Design load effect > Fb,fi , revise time t and recalculate until resistance > load effect

Design load effect = 1.0D + 1.0L

5. Calculate the load effect using unfactoredload

Page 48: Major changes in CSA O86 -2014 to address mid-rise

Contribution of gypsum board

Gypsum Board Members Fire Resistance Rating

One layer of 12.7mm (½ in) GWB 15min

One layer of 15.9mm (⅝ in) GWB 30min

Two layers of 12.7mm (½ in) GWB 40min

Two layers of 15.9mm (⅝ in) GWB 60min

Three layers of 15.9mm (⅝ in) GWB 90min

Four layers of 15.9mm (⅝ in) GWB 120min

Page 49: Major changes in CSA O86 -2014 to address mid-rise

Mid- to high-rise wood buildings around the world

9-storey, London (2009)

10-storey, Melbourne (2012)

7-storey, Växjö, Sweden (2008)

Page 50: Major changes in CSA O86 -2014 to address mid-rise

14-storey, Bergen, Norway (2014-15)https://www.youtube.com/watch?feature=player_detailpage&v=e5XsqauBCX4

Mid- to high-rise wood buildings around the world

Page 51: Major changes in CSA O86 -2014 to address mid-rise
Page 52: Major changes in CSA O86 -2014 to address mid-rise

Thank you