9
Management Of Requirements At FMC June 1st 2010 Barbara W. Eiken

Management Of Requirements At FMC

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Management Of Requirements At FMC

June 1st 2010

Barbara W. Eiken

Quality Definition (Philip B. Crosby)

Product range

Turret Mooring Systems

Tension Leg Platforms

Light Well Intervention

Guidelineless Deepwater Trees

Subsea Manifold

Smart Well Control Systems Subsea Template

Systems

Standard Subsea Trees

Metering & Control Systems

Surface Well Systems

ROV Tie-In Systems

Subsea Processing

Subsea Drilling Systems

Yesterday

Change

Change

Change

Change

Today With RM Matrix

Change

RM Matrix

System part of RMM today:

135 requirements

RMM today:

1040 requirements

RM Matrix: Implementation Challenges

• Investments have to be made early, gains of improved performance are gathered later in the project life cycle

• Business Processes have to be updated

TenderProduct

EngineeringProcurement

Production /

Build + Test

System

Engineering

Contract

Improved performance

Investment

Project live

Eff

ect of R

M M

atr

ix

RMM + Function Tree

R2 R 3 R4 R5

R1

Rx: Set of requirements defining the function

of the corresponding system / product level

R6

R18

R7 R8 R11 R12 R13R9 R10 R14 R15 R16 R17

R19 R20 R21 R22 R23 R24 R20 R21 R22 R23 R24 R25 R26 R27 R28 R29R30 R31 R32 R33 R34 R35 R36 R37R38 R39 R40 R41 R42

System

Requirements

Sub-System

Requirements

Product Family

Requirements

Product

Requirements

RequirementParameter

Service Life 5 years

Water depth 500 m…

… …

Rsystem

Total Weight Max 40 Te…

… …

… …

Rsub-ystem

BOP System data…

… ?… …

Rproduct family

Umbillical bending radius …

… …RProduct

… …

?

?

Assumptions

Rig XX

BOP XX

“RMM”

Only few

parameters

are different

Master

parts

Requirements

independent of

customer/FMC

Standard

parts

Requirements

FMC (Strategy, etc.)

Requirements

Customer A

Requirements

Customer B

Requirements

Customer C

Requirements

Customer D

R18A R18

B R18C R18

D

R1A R1

B R1C R1

D

R18FMC

R1FMC

R2A R2

B R2C R2

D R2FMC

R3A R3

B R3C R3

D R3FMC

R6A R6

B R6C R6

D R6FMC

R19A R19

B R19C R19

D R19FMC

R20A R20

B R20C R20

D R20FMC

R21A R21

B R21C R21

D R21FMC

… … … … …

… … … … …

… … … … …… … … … …

… … … … …R26

A R26B R26

C R26D R26

FMC

Standardization

R2 R 3 R4 R5

R1

R6

R18

R7 R8 R11 R12 R13R9 R10 R14 R15 R16 R17

R19 R20 R21 R22 R23 R24 R20 R21 R22 R23 R24 R25 R27 R28 R29R30 R31 R32 R33 R34 R35 R36 R37R38 R39 R40 R41 R42R26

R30R29

Split

functions