APDD 702BJune 2000
XF 7.5 - 15EP 7.5 - 15HP 7.5 - 15XP 7.5 - 15
OPERATORS/INSTRUCTION MANUALPARTS LISTRECOMMENDED SPARES
Before installation or starting the compressor for
the first time,this manual should be studied careful-
ly to obtain a clear knowledge of the unit and of the
duties to be performed while operating and main-
taining the unit.
RETAIN THIS MANUAL WITH UNIT.
This Technical manual contains IMPORTANT SAFE-
TY DATA and should be kept with the air compres-sor at all times.
More Than Air. Answers.Online answers: http://www.air.ingersoll-rand.com
7/27/2019 Manual de Compresor Ingersoll Rand
2/74
INGERSOLL-RAND COMPANY
AIR COMPRESSOR GROUPBONDED WARRANTY & REGISTERED START UP
WarrantyThe Company warrants that the equipment manufactured by it and delivered hereunder will be free of defects in
material and workmanship for a period of twelve months (see extended airend warranty) from the date of placingthe Equipment in operation or eighteen months (see extended airend warranty) from the date of shipment fromDavidson, NC, whichever shall first occur.The Purchaser shall be obligated to promptly report any failure to conformto this warranty, in writing to the Company in said period, whereupon the Company shall, at its option, correct suchnonconformity, by suitable repair to such equipment or, furnish a replacement part F.O.B.point of shipment, provid-
ed the Purchaser has stored, installed maintained and operated such Equipment in accordance with good industrypractices and has complied with specific recommendations of the Company.Accessories or equipment furnished bythe Company, but manufactured by others, shall carry whatever warranty the manufacturers have conveyed to theCompany and which can be passed on to the Purchaser.The Company shall not be liable for any repairs, replace-ments, or adjustments to the Equipment or any costs of labor performed by the Purchaser or others withoutCompanys prior written approval.The effects of corrosion, erosion and normal wear and tear are specifically excluded.Performance warranties are
limited to those specifically stated within the Companys proposal. Unless responsibility for meeting such perfor-mance warranties are limited to specified tests, the Companys obligation shall be to correct in the manner and forthe period of time provided above.
THE COMPANY MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER,EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES OF MERCHANTABILI-TY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED.
Correction by the Company of nonconformities whether patent or latent, in the manner and for the period of timeprovided above, shall constitute fulfillment of all liabilities of the Company for such nonconformities whether basedon contract, warranty negligence, indemnity, strict liability or otherwise with respect to or arising out of suchEquipment.The purchaser shall not operate Equipment which is considered to be defective, without first notifying the Company
in writing of its intention to do so.Any such use of Equipment will be at Purchasers sole risk and liability.
Limitation of LiabilityThe remedies of the Purchaser set forth herein are exclusive, and the total liability of the Company with respect to
this contract or the Equipment and services furnished hereunder, in connection with the performance or breachthereof, or from the manufacture, sale, delivery, installation, repair or technical direction covered by or furnishedunder this contract, whether passed on contract, warranty negligence, indemnity, strict liability or otherwise, shall notexceed the purchase price of the unit of Equipment upon which such liability is based.The Company and its suppliers shall in no event be liable to the Purchaser, any successors in interest or any ben-
eficiary or assignee of this contract for any consequential, incidental, indirect, special or punitive damages arisingout of this contract or any breach thereof, or any defect in, or failure of, or malfunction of the Equipment hereunder,whether based upon loss of use, lost profits or revenue, interest, lost goodwill, work stoppage, impairment of othergoods, loss by reason of shutdown or non-operation, increased expenses of operation, cost of purchase of replace-ment power or claims of Purchaser or customers of Purchaser for service interruption whether or not such loss ordamage is based on contract, warranty, negligence, indemnity, strict liability or otherwise.
EXTENDED AIREND WARRANTYThe Ingersoll-Rand Company Rotary Screw Air Compressor that has been
filled prior to its original shipment from Ingersoll-Rand Company with ULTRA
COOLANT and which has been operated solely on ULTRA COOLANT there-
after shall have its AIREND warranted for twenty four (24) months from the
date of placing the COMPRESSOR in operation or thirty (30) months from the
date of shipment, whichever occurs first.
Except for the above warranty period, the standard warranty provisions shall
apply and the conditions outlined herein are understood to be a supplement to
the standard Ingersoll-Rand Company warranty.
7/27/2019 Manual de Compresor Ingersoll Rand
3/74
1
ROTARY SCREW AIR COMPRESSOR
This unit was purchased from
Ingersoll-Rand Company reserves the right to make changes or add
improvements without notice and without incurring any obligation to make
such changes or add such improvements to products sold previously.
No. of units on order:
Customer Order No:
Ingersoll-Rand Co. Order No.:
For ready reference:
Record the serial number and model number of your unit here.
Serial Number:
Model Number:
7/27/2019 Manual de Compresor Ingersoll Rand
4/74
2
TABLE OF CONTENTS
0.0 SAFETY AND WARNINGS
0.1 safety instructions
0.2 safety precautions
0.3 decals
1.0 RECEIPT OF EQUIPMENT1.1 inspection
1.2 unpacking and handling
2.0 INSTALLATION
2.1 ventilation
2.2 foundation requirements
2.3 outdoor installations
2.4 piping
2.5 electrical installation
2.6 voltage conversion
2.7 rotation check
2.8 before starting - starting - stopping
3.0 SYSTEMS
3.1 general system information
3.2 coolant system
3.3 air systems
3.4 capacity control
3.5 pressure switch adjustment
4.0 MAINTENANCE
4.1 maintenance schedule
4.2 maintenance records
4.3 maintenance procedures
4.4 pressure relief valve check
4.5 sheave alignment
4.6 drive belt
4.7 belt tension
4.8 shaft seal replacement
4.9 inlet air filter element
4.10 coolant filter element
4.11 coolant change
4.12 coolant hose
4.13 coolant separator element
4.14 separator tank scavengecheck valve/screen/orifice
4.15 cooler cores/cleaning
4.16 motor bearing maintenance-stored units
5.0 TROUBLE SHOOTING
6.0 REFERENCE DRAWINGS
6.1 electrical schematic - full voltage
6.2 electrical schematic - star-delta
6.3 piping diagram
6.4 found. plan - 80 gal tank mounted - enclosed
6.5 found. plan - 80 gal tank mounted - unenclosed
6.6 found. plan - 120 gal tank mounted - enclosed
6.7 found. plan - 120 gal tank mounted - unenclosed6.8 found. plan - base mounted - enclosed
6.9 found. plan - base mounted - unenclosed
6.10 typical system flow diagram
7.0 PARTS LIST
7.1 introduction
7.2 parts listing
starter box assembly
starter assembly - full voltage
starter assembly - star-delta
major components assembly
drive componentscontrol piping assembly
cooler box assembly with aftercooler
cooler box assembly without aftercooler
80 gallon receiver tank assembly
120 gallon receiver tank assembly
canopy assembly option
table - O-rings
7.3 service and option kits
7.4 recommended spare parts
8.0 MAINTENANCE RECORD
GENERAL INFORMATION
Cooling Air Flow:
60 Hz: 1800 cfm (0.85 m3/sec)
50 Hz: 1500 cfm (0.71 m3/sec)
Ambient Temperature Limit: 35F to 115F (2C to 46C)
Coolant: Factory Filled ULTRA COOLANT
Coolant Change: 8,000 hours or two years, whichever
comes first, when using ULTRA COOLANT
Coolant Capacity: 1.5 GAL (5.75L)
DischargeTemperature Limit: 228F (109C)
Tools: U.S. Standard and metric are required to perform
maintenance
7/27/2019 Manual de Compresor Ingersoll Rand
5/74
3
0.0 SAFETY AND WARNINGS0.1 SAFETY INSTRUCTIONSBefore you install this air compressor you should take the timeto carefully read all the instructions contained in this manual.
Electricity and compressed air have the potential to causesevere personal injury or property damage.
Before installing, wiring, starting, operating or making anyadjustments, identify the components of the air compressorusing this manual as a guide.
The operator should use common sense and good workingpractices while operating and maintaining this unit. Follow allcodes, pipe adequately, understand the starting and stoppingsequence. Check the safety devices by following the proce-dure contained in this manual.
Maintenance should be done by qualified personnel, ade-quately equipped with proper tools. Follow the maintenanceschedules as outlined in the operators manual to ensure prob-lem free operation after start up.
Safety instructions in the operators manual are bold-faced foremphasis. The signal words DANGER, WARNING and CAU-TION are used to indicate hazard seriousness levels as fol-lows:
Danger is used to indicate the presence of
a hazard which will cause severepersonal
injury, death, or substantial property dam-
age if the warning is ignored.
Warning is used to indicate the presence of
a hazard which can cause severepersonal
injury, death, or substantial property dam-
age if the warning is ignored.
Caution is used to indicate the presence of
a hazard whichwill or can cause minorper-
sonal injury or property damage if the warn-
ing is ignored.
Notice is used to notify people of installa-
tion, operation,or maintenance information
which is important but not hazard-related.
D! DANGER
! WARNING
! CAUTION
NOTICE
SAFETY PRECAUTIONSBEFORE PROCEEDING, READ CAREFULLY BEFORE INSTALLING THE
COMPRESSOR OR PERFORMING ANY MAINTENANCE
WARNING
COMPRESSED AIR AND ELECTRICITYARE DANGEROUS.
BEFORE DOING ANY WORK ON THISUNIT, BE SURE THE ELECTRICAL SUP-PLY HAS BEEN CUT OFFLOCKED &TAGGED AND THE ENTIRE COMPRES-SOR SYSTEM HAS BEEN VENTED OFALL PRESSURE.
1. Do not remove the covers, loosen orr e m ove any fittings, connections ordevices when this unit is in operation.Hot liquid and air under pressure thatare contained within this unit can causesevere injury or death.
2. The compressor has high and dan-gerous voltage in the motor starter andcontrol box. All installations must be inaccordance with recognized electricalcodes. Before working on the electricalsystem, be sure to remove voltage fromthe system by use of a manual-discon-nect-switch. A circuit breaker or fusesafety switch must be provided in theelectrical supply line leading to thecompressor.
Those responsible for installation ofthis equipment must provide suitableg ro u n d s , maintenance clearance andlightning arrestors for all electrical com-ponents as stipulated in O. S . H . A .1910.308 through 1910.329.
3. Do not operate the compressor athigher discharge pressure than thosespecified on the Compressor Nameplateor motor overload will occur.This condi-tion will result in compressor motorshutdown.
4. Use only safety solvent for cleaningthe compressor and auxiliary equip-ment.
5. Install a manual shut off valve (isola-tion type) in the discharge line.When asafety valve is installed between the iso-lation valve and the compressor,it musthave sufficient capacity to relieve thefull capacity of the compressor(s).
6 . W h e n ever pressure is releasedthrough the pressure relief valve, it isdue to excessive pressure in the sys-tem.The cause for the excessive pres-sure should be investigated immediate-ly.
7.Before doing any mechanical work onthe compressor:
a.) Shut the unit down.
b.) Electrically isolate the compressorby use of the manual disconnect switchin the power line to the unit. Lock andtag the switch so that it cannot be oper-ated.
c.) Vent pressure from the compressorand isolate the unit from any othersource of air.
8. There can be adverse effects if com-pressor lubricants are allowed to enterplant air systems.
Air line separators, properly selectedand installed, will minimize any liquidcarry-over.
The use of plastic bowls on line filterswithout metal guards can be hazardous.From a safety standpoint, metal bowlsshould be used on any pressurized sys-tem.Review of your plant air line systemis recommended.
9.When a receiver is installed, it is rec-ommended that occupational safety andhealth standards as covered in theFederal Register, Volume 36, nu m b e r1 0 5 , p a rt 11, p a r agraph 1910.169 beadhered to in the installation and main-tenance of this receiver.
10. Before starting the compressor, itsmaintenance instructions should bethoroughly read and understood.
1 1 . After maintenance functions arecompleted, covers and guards must bereplaced.
0.2 SAFETY PRECAUTIONS
7/27/2019 Manual de Compresor Ingersoll Rand
6/74
4
There is a high discharge air temperature shutdown function built into each compressor. It is factory pre-set at 228F (109C).This function should be checked at regular intervals for proper operation,once a monthis recommended.PROCEDURE:
1. Block off the cooling air discharge.
2.The compressor discharge temperature will rise at a rapid rate. Shutdown should occur when the dis-charge temperature reaches the pre-set maximum discharge air temperature setting.
Failure to adhere to these recommendations can result in mechanical failure,property damage and serious
injury or death.
All air and water inlet, and air and water discharge pipework to and from the inlet and discharge port con-
nections must take into account vibration, pulsations, temperature, maximum pressure applied, corrosion
and chemical resistance. In addition, it should be noted that lubricated compressors will discharge some
oil into the air stream;therefore, compatibility between discharge piping, system accessories and software
must be assured.
For the foregoing reasons, the use of plastic piping,soldered copper fittings and rubber hose as discharge
piping is not recommended.In addition,flexible joints and/or flex lines can only be considered for such pur-
poses if their specifications fit the operating parameters of the system.
It is the responsibility of the installer and owner to provide the appropriate service pipework to and from
the machine.
Ingersoll-Rand air compressors are not designed, intended, or approved for breathing air applications.
Ingersoll-Rand does not approve specialized equipment for breathing air application and assumes no
responsibility or liability for compressors used for breathing air services.
! WARNING
! WARNING
! SAFETY SHUTDOWN CHECK HIGH AIR TEMPERATURE
7/27/2019 Manual de Compresor Ingersoll Rand
7/74
5
0.3 DECALS
This section contains representative examples ofdecals which will be appearing throughout this manual
and are applied to the compressor unit.
If for some reason a decal is defaced, parts arereplaced or painted over, we recommend that you
obtain a replacement (See Recommended SpareParts List for Decal Kit Number).
39540273
39921804
39540240
39879762 I-R LOGO ON RECEIVER TANK
39868419 IR LOGO ON CANOPY (ENCLOSED UNITS)
39540265
39541362
7/27/2019 Manual de Compresor Ingersoll Rand
8/74
6
3954190
39544143
39544150
39540232
39540174
39859236
39540166*
39540257**THESE DECALS ARE LOCATED ON THE END OF THERECEIVER TANK ON TANK MOUNTED UNITS.
I N GE R S O L L r A N D
39540281
7/27/2019 Manual de Compresor Ingersoll Rand
9/74
7
7/27/2019 Manual de Compresor Ingersoll Rand
10/74
8
1.0 RECEIPT OF EQUIPMENT
1.1 INSPECTION
When you receive the compressor please inspect it
closely. Any indication of careless handling by the car-rier should be noted on the delivery receipt especiallyif the compressor will not be immediately un-crated.
Obtaining the delivery mans signed agreement to anynoted damages will facilitate any future insurance
claims.
1.2 UNPACKING AND HANDLINGThe compressor package has been mounted on awooden shipping base which will allow fork lifting
under the compressor base to facilitate handling dur-ing shipment. Care in positioning the forklift is impor-
tant because the location of the center of gravity isstrongly affected by the location of the airend and drive
motor.
The wooden base must be removed prior to installa-tion.
2.0 INSTALLATION
2.1 VENTILATION
Air cooled air compressors produce large amounts ofheat. Because of this large heat production, the com-pressor must be placed in a room with adequate venti-
lation.
If heated air from the compressor exhaust is allowed tore-circulate back to the compressor, the compressorwill overheat and shut down.This heat must beexhausted from the room.You should take this into
consideration when deciding where to place the com-pressor within the building. Sufficient clearance must
be allowed around the compressor to perform therequired maintenance.
Ambient temperatures higher than 115F (46C)should be avoided as well as areas of high humidi-ty. Also consider the environment near the com-
pressor.
DUST, CHEMICALS, METAL FILINGS, PAINT FUMES,and OVERSPRAY should be avoided as well as anyother conditions which might be detrimental to the
proper operation of the compressor.
2.2 FOUNDATION REQUIREMENTS
The compressor can be installed on any level floor that
is capable of supporting the weight.
When sound transmission is of particular importance,
it is often helpful to install a sheet of rubber-fabric-mat-ting, under the compressor baseplate or receiver tankfeet to reduce the possibility of resonant sounds being
transmitted or amplified through the floor.
2.3 OUTDOOR INSTALLATIONS
When a compressor must be installed outside, there
are certain items that should be incorporated into theinstallation to help assure trouble free operation.Theseitems have been listed below plus Figure 2.3-1 has
been included to show a typical outdoor protectedinstallation.The unit must be purchased with the
NEMA 4 option to provide watertight electrics, and aTEFC motor.
The compressor should be on a concrete paddesigned to drain water away. If the concrete pad is
sloped, then the compressor must be leveled.
The roof of the shelter should overhang the compres-
sor a minimum of 4 feet (1.2m) on all sides to preventdirect rain and snow from falling on the unit.
The unit must be arranged under the shelter in a waythat prevents air recirculation (i.e. hot exhaust back tothe package inlet).
If the installation includes more than one compressor,
the hot air exhaust should not be directed towards thefresh air intake of the second unit or an Air Dryer.
If a standard machine is to be installed outside, theambient temperature must never drop below 35F
(2C) or freezing of condensate will result.
Power disconnect switch must be within the compres-
sor operators line of sight and should be in close prox-imity to the unit.
Condensate drains must never be allowed to dumpon the ground. Pipe to a suitable sump for future col-lection, disposal or separation of lubricant and water
mixture.
Incoming power connections must use suitable con-
nectors for outdoor weather tight service.
Sufficient clearance must be allowed on all four sidesof the unit for service access. If possible, access by a
fork lift and/or an overhead beam hoist should be keptin mind (for eventual service to airend or motor).
7/27/2019 Manual de Compresor Ingersoll Rand
11/74
9
If the area around the installation contains fine air-borne dust or lint and fibers etc., then the unit should
be purchased with the TEFC motor option.
Some type of protection such as a fence or securitysystem, should be provided to prevent unauthorized
access.
FIGURE 2.3-1 TYPICAL OUTDOOR SHELTERED INSTALLATION35F (2C) AND ABOVE
DISCHARGEPIPE
(STEEL)
POWERDISCONNECT SWITCH
PRESSURETREATED
TIMBER TO
LEVEL
SLOPINGCONCRETE
PAD
ISOLATIONVALVE
DRIPLEG
AREA SHOULD BESECURED WITH A FENCEOR SECURITY SYSTEM
4(1.2m)OVER-HANG(ALL
SIDES)
7/27/2019 Manual de Compresor Ingersoll Rand
12/74
10
2.4 PIPING
It is essential when installing a new compressor to
review the total plant air system.This is to insure a safeand effective total system.
The use of plastic bowls on line filters without metal
guards can be hazardous.Their safety can be affected
by either synthetic lubricants or the additives used inmineral oils. From a safety standpoint, metal bowls
should be used on any pressurized system.
Condensed water occurs naturally in air lines as a resultof compression. Moisture vapor in ambient air is concen-
trated when pressurized and condenses when cooled indownstream air piping.
Moisture in compressed air is responsible for costly
problems in almost every application that relies on com-pressed air. Some common problems caused by mois-
ture are: rusting and scaling in pipelines, clogging ofinstruments, sticking of control valves, and freezing of
outdoor compressed air lines. Any of these could resultin partial or total shutdown of the compressed air sys-
tem.
The compressed air discharging from this compressorwill be at some elevated temperature and will therefore
contain amounts of water vapor. As this air cools, the
vapor will condense within the piping system.IMPORTANT:The drain line must slope downward fromthe trap to work properly.
NOTE: For ease of inspection of the automatic drain
trap operation, the drain piping should include an openfunnel or some type of sight flow indicator.
It is possible that additional condensation can occur ifthe downstream piping cools the air even further.
Therefore, low points in the piping system should beprovided with driplegs and traps.
Compressed air dryers reduce the water vapor concen-tration and prevent liquid water formation in compressedair lines. Dryers are a necessary companion to filters,
aftercoolers, and automatic drains for improving the pro-ductivity of compressed air systems.Two types of dry-ers, refrigerated or desiccant , are used to correct mois-
ture related problems in a compressed air system.Refrigerated dryers are normally specified where com-
pressed air pressure dew points of 33F to 39F (.5C to4C) are adequate. Desiccant dryers are required where
pressure dew points must be below 33F (.5C).
! WARNING
Do not use plastic pipe, soldered copper fittings
or rubber hose for discharge piping.
Figure 2.4-1 indicates the approximate moisture con-tent in compressed air at various operating points.
Contact your local Ingersoll-Rand Distributor or Air
Center for assistance in selecting correct Ingersoll-Rand filtration or drying products.
Moisture Content of Compressed Air
FIGURE 2.4-1 MOISTURE CONTENT OF
COMPRESSED AIR
200
160
120
80
40
0
DEW POINT
t without 100F (with 35F -40F (DesiccantAftercooling Aftercooler) (Refrigerated Dryer)
Dryer)
7/27/2019 Manual de Compresor Ingersoll Rand
13/74
11
IMPORTANT: Discharge piping should be at least aslarge as the discharge connection at the compressor.
All piping and fittings must be suitably rated for thedischarge pressure and temperature.
A careful review of piping size from the compressorconnection point is essential. Length of pipe, size of
pipe, number and type of fittings and valves must be
considered for minimum air pressure drop and opti-mum efficiency of your compressor.
NOTE: Screw type compressors should not beinstalled in air systems with reciprocating compres-
sors without a means of pulsation isolation, such as acommon receiver tank.We recommend both types ofcompressor units be piped to a common receiver uti-
lizing individual air lines. See Figure 2.4-2.
When two rotary units are operated in parallel, pro-
vide an isolation valve and drain trap for each com-pressor before the common receiver.
See Figure 2.4-3
To assure long trouble free operation of a compressoroperating with On-line/ Off-line and Auto Stop/Start
control, the system volume must be large enough tokeep the load/unload cycles to a minimum.This may
require the installation of a receiver down stream ofthe compressor. Baseplate mounted units must be
piped to a receiver if installed in a system with insuffi-cient volume to keep compressor cycling to a mini-mum. If equipment such as filters or air dryers, is
installed in the main piping system, they must besized to handle the entire flow of the compressor and
an air receiver must be placed in the system between
the compressor discharge and the equipment,regardless of system volume.
This will prevent quick cycling of the compressorwhich results in large fluctuations in system pressure.
FIGURE 2.4-2 ROTARY-RECIP IN PARALLEL
FIGURE 2.4-3 ROTARY-TWOCOMPRESSOR SYSTEM
ROTARYCOMPRESSOR
ROTARY
COMPRESSOR
ROTARYCOMPRESSOR
7/27/2019 Manual de Compresor Ingersoll Rand
14/74
12
2.5 ELECTRICAL INSTALLATION
Before proceeding further, we recommend that youreview the safety data in the front of this manual.
Locate the compressor data plate on the left end ofthe cooler box next to the control box (See Figure2.5-1).
The data plate lists the rated operating pressure, themaximum discharge pressure, the electric motor char-
acteristics and power.
Confirm that the line voltage and compressor name-
plate voltage are the same.
The standard control box meets the intent of NEMA 1guidelines.
It will be necessary to make a hole in the control boxfor the incoming power connection. Care should be
taken to not allow metal shavings to enter the starter
and other electrical components within the box. Aftermaking the power inlet hole, all shavings and debris
must be removed from inside of control box beforepower is turned on.
Incoming power should be connected per the electri-cal schematic at the rear of this manual (See Section
6.0). Confirm that all electrical connections are madeand tightened. Confirm that the control transformer iswired correctly for supply voltage (See Figure 2.6-1). FIGURE 2.6-1 CONTROL TRANSFORMER
CONNECTIONS
PRIMARY
SECONDARY
Inspect the motor and control wiring for tightness.Replace control box door.
2.6 VOLTAGE CONVERSION
IMPORTANT:This procedure should only be carried out
by a qualified electrician, electrical contractor or yourlocal Ingersoll Rand Distributor or Air Center.
FIGURE 2.5-1 COMPRESSOR DATA PLATE
NOTE:This procedure applies only to units manufac-tured to multi-voltage specifications. Compressor dataplate and motor nameplate must indicate multiple volt-
ages.
7/27/2019 Manual de Compresor Ingersoll Rand
15/74
13
2.7 ROTATION CHECK.
Locate the rotation decal on the motor and check for
correct rotation.The correct rotation when viewed fromthe opposite drive end of the motor is clockwise.
If compressor is operated in the opposite direction ofrotation, airend damage can result and is not war-rantable.
The unit is shipped with a bolt in the motor support toprevent possible belt damage caused by bouncing dur-
ing shipment.This bolt must be remove prior to check-ing motor rotation or operating the unit.
Locate the shipping bolt in the motor support as shownin Figure 2.7-1. and remove.
For the compressor motor rotation check, the motorjogging should be as short a time as possible.
1. Ensure that the Stop button is in the stop
(depressed) position.
2. Check coolant level.To check coolant level, slowly
loosen the fill plug one complete turn. As the fill plug isunscrewed approximately one turn, a small amount of
pressure may be released. Do not remove the fill pluguntil all pressure has been vented. Once pressure isvented, finish removing the fill plug.The proper coolant
level is when the coolant is even with the top of the fillport. Add coolant if necessary.
3. Replace and tighten fill plug.
4. Close the main disconnect switch (ON position).
5.Verify that the main isolation valve is open.
6. Open the canopy enclosure if machine is so
FIGURE 2.7-1 SHIPPING BOLT LOCATION
SHIPPING BOLT
PROCEDURE:
Put main disconnect in the OFF position, lock and tag
(See Figure 2.6-2).
Open the motor junction box on the side of the motor.
Reconnect the motor to the desired voltage. Use theconnection diagram provided on the motor as a guide.
Reconnect the primary side of the control transformer
for the desired voltage, as shown on the control trans-former wiring decal.
Adjust motor overload setting as outlined below inFigure 2.6-3.
FIGURE 2.6-3 MOTOR OVERLOAD SETTING
Make sure all wiring connections are tight.
Put main disconnect in the ON position and check
motor rotation, as outlined in Section 2.7 of this manu-al.
FIGURE 2.6-2 MAIN DISCONNECT
LOCKED AND TAGGED
7/27/2019 Manual de Compresor Ingersoll Rand
16/74
14
equipped. Push the Start button to start the unit andimmediately depress (push) the Stop button to stop the
unit.Observe the compressor drive motor shaft. The rota-
tion should be in accordance with the directional arrowdecal on the motor.
Should the motor rotation not be correct, put the main
disconnect in the OFF position, lock and tag.
Interchange any two line connections (L1 ,L2, or L3) at
the starter. Close the control box cover. Recheck forcorrect rotation.
2.8 BEFORE STARTING - STARTING - STOPPING
Read and understand the following instructions
before operating or performing any maintenanceon this unit.
Before Starting:
1. Ensure that Stop push button is in the OFF(depressed) position (See Figure 2.8-1).
2. Check coolant level.To check coolant level, slowly
loosen the fill plug one complete turn. As the fill plug isunscrewed approximately one turn, a small amount of
pressure may be released. Do not remove the fill pluguntil all pressure has been vented. Once pressure is
vented, finish removing the fill plug.The proper coolantlevel is when the coolant is even with the top of the fillport. Add coolant if necessary.
3. Replace and tighten fill plug.
4. Close the main disconnect switch (ON position).
5.Verify that the main isolation valve is open.
FIGURE 2.8-1 CONTROL BOX
CONTROLBOX
START
BUTTON
STOP
BUTTONHOURMETER
PRESSURE
GAUGE
POWER ON
LIGHT
AUTO RESTARTLIGHT
Starting
1. Push the Start button and release.The compressor
will start and then load automatically if line pressure isbelow the lower set point of the pressure switch.
Stopping
1. Depress the Stop button to the OFF position.
Compressor will stop immediately.
2. Open the main disconnect switch (OFF position).
3.0 SYSTEMS
3.1 GENERAL SYSTEM INFORMATION
The compressor is an electric motor driven, single
stage, rotary screw compressor, complete with sup-porting components to make a fully functional unit. A
standard compressor is composed of the following:Inlet air filterDrive motor
AirendPressurized coolant system with cooler & filter
Separation systemCapacity control
InstrumentsSafety devices
Compression in the rotary screw type air compressoris created by the meshing of two helical rotors (male
and female) on parallel shafts, enclosed in a heavy
duty iron housing, with air inlet and outlet ports locatedon opposite ends.The grooves of the female rotormesh with and are driven by the male rotor. Bearingson both ends of the rotors are used to support the
rotor both laterally and axially.
3.2 COOLANT SYSTEM
The coolant system consists of a separator tank, ther-
mostatic element, coolant filter, coolant cooler withfans, and a separator element.When the unit is operat-ing, the coolant is pressurized and forced to the com-
pressor bearings.The compressor is provided with a
temperature switch which will shut the unit down incase of excessive temperature, 228F (109C).Effective coolant filtration is provided by the use of a
screw on, automotive type, heavy duty coolant filter.
The compressor is designed for operation in an ambi-ent range of 35F to 115F (2C to 46C).The stan-
dard maximum temperature 115F (46) is applicableup to an elevation of 3300 ft. (1000 m).
7/27/2019 Manual de Compresor Ingersoll Rand
17/74
15
Coolant
Rotary screw compressor fluids have a triple function
to perform.They lubricate the bearings and contactingsurfaces of the rotors, seal internal clearances within
the rotor chamber, and provide for the cooling of thecompression process.The bulk of the fluid is actually
used for cooling, with only small amounts used for
lubrication and sealing.
SSR air compressors are factory filled with SSR
ULTRA COOLANT. ULTRA COOLANT is designedto operate for 8,000 hours or two years, whichever
comes first.The coolant must be changed at theseintervals to avoid breakdown and equipment dam-age.
Circulation of Coolant
Coolant is forced by air pressure from the separator
tank to the thermostatic element.The position of theelement (a direct result of coolant temperature) willdetermine whether the coolant circulates through the
cooler, bypasses the cooler, or mixes the two pathstogether to maintain an optimum compressor injection
temperature.This temperature is controlled to precludethe possibility of water vapor condensing. By injecting
coolant at a sufficiently high temperature, the dis-charge air coolant mixture temperature will be keptabove the dew point.
Before being injected into the airend, all coolant flowsthrough the coolant filter. It is a full-flow, spin-on ele-
ment, rated at 4 micron.There is a differential-pressure
bypass valve in the element that opens in the eventthat the pressure drop across the element rises to ashigh as 15 psi (1 bar), which indicates an excessivelyfouled element as well as poor maintenance practice.
Coolant/Air Separator System
The coolant/air separation system is composed of aseparator tank with specially designed internals and a
coalescing type separator element located inside thetank.
The air-coolant mixture discharges from the airend into
the separator tank.The majority of coolant is separat-ed while in the separator tank and the coalescing sep-
arator filter element is used for final cleaning of the airprior to the customers system.The system removes
nearly all of the coolant from the discharge air.Theseparated coolant is returned to the coolant systemand the air passes to the compressed air system.
3.3 AIR SYSTEM
Components and Flow
The air system is composed of:Inlet air filter
Inlet valveAirendCoolant/Air separator
Minimum pressure check valve (MPCV)Aftercooler
The direction of flow is from the inlet filter to the after-cooler.
Functions of Components
Inlet air filter, filters the incoming air, trapping 99.9% of
particles 3 micron and larger.
Inlet valve opens full for on-line operation.The valve
closes in the off-line mode and at shutdown which pre-
vents back flow of the compressed air.
The airend compresses the air.
The separator tank removes most of the coolant fromthe air.
The separator element performs the final separation ofcoolant and cleaning of the air prior to leaving the
compressor.
The minimum pressure check valve keeps the separa-tor tank and separator element at a minimum pressure
to ensure adequate oil flow and proper coolant/air sep-
aration. It also prevents line pressure from exhaustingback through the airend at shutdown and during peri-ods of unloaded operation.
The aftercooler cools the air prior to leaving the pack-
age.
7/27/2019 Manual de Compresor Ingersoll Rand
18/74
16
3.5 PRESSURE SWITCH ADJUSTMENT
Locate the pressure switch as shown in Figure 3.5-1.The pressure switch can be adjusted using the follow-
ing procedure:
1. Open, lock and tag the main electrical disconnect.Do not adjust the pressure switch with power on or
machine operating.
2. Remove pressure switch cover by turning the cover
screw counterclockwise.NOTE: It is required that the load or on-line pressure
be set first, before the unload or off-line pressure isset.
3. Set the on-line pressure by turning screw 5 (See
Figure 3.5-2).Turn clockwise to increase setting orcounter-clockwise to decrease setting (indicated by
pointer 4).
FIGURE 3.5-1 PRESSURE SWITCH LOCATION
FIGURE 3.5-2 PRESSURE SWITCH ADJUSTMENT
PRESSURE SWITCH
5 2 34
4. Set the off-line pressure by turning screw 2.Turnscrew counter-clockwise to increase setting or clock-
wise to decrease setting (indicated by pointer 3).
CAUTION:
DO NOT EXCEED MAXIMUM DISCHARGE PRES-SURE (LOCATED ON COMPRESSOR DATA
PLATE).
5.Turn power back on, start compressor and test
adjustment(s) made. If necessary, readjust accordingto steps 1-4 above.
3.4 CAPACITY CONTROL
On Line/Off Line With Automatic Start/Stop
Control
The compressor will deliver air at full capacity, (the
compressor maximum efficiency condition) or willoperate at zero capacity with high receiver pressure(the compressor minimum power condition), while the
unit continues to run.
When the compressor starts and line pressure is
below the lower setting of the line pressure switch,control solenoid 1SV will be energized (closed), inlet
valve will open, and the compressor will load.Whenthe line pressure reaches the upper setting of thepressure switch, the compressor will unload by de-
energizing (opening) 1SV and closing the inlet valve.Solenoid 1SV relieves the internal pressure of the
compressor back to the inlet filter.The only adjustmentrequired is setting of the pressure switch.
A time delay relay is energized and begins to time out.The timer, mounted in the control box, is factory set at10 minutes. It will continue to operate for as long as its
time setting, after which a relay contact opens to de-energize the compressor starter coil. At the same
time, an amber light (1LT) on the control box is lit toindicate the compressor has shut down automatically
and will restart automatically.The automatic restart willtake place when the line pressure drops to the lowersetting of the pressure switch. Adjusting the
Auto/Restart timer below the 10 minute factorysetting may shorten the life of the compressor
drive motor.
7/27/2019 Manual de Compresor Ingersoll Rand
19/74
17
4.0 MAINTENANCE4.1 MAINTENANCE SCHEDULE
THE MAINTENANCE SCHEDULE SPECIFIES ALL RECOMMENDED MAINTENANCE REQUIRED TO KEEP THE COM-PRESSOR IN GOOD OPERATING CONDITION.SERVICE AT THE INTERVAL LISTED OR AFTER THAT NUMBER OFHOURS, WHICHEVER OCCURS FIRST.
ACTION PART OR ITEM HOURS 1WK 1 MO 6 MO 9 MO YEARLY 2YR
INSPECT COOLANT LEVEL VISIBLE IN FILL PORT WEEKLY X(WHEN COLD)
INSPECT AIR FILTER WEEKLY X
REPLACE COOLANT FILTER* 150 X
REPLACE COOLANT FILTER* 2000 X
INSPECT HOSES 1000 X
INSPECT DRIVE BELTS 500 X
REPLACE DRIVE BELTS 8000 X
CHECK HIGH AIR TEMP.SWITCH 1000 X
CHECK OPERATE PRESSURE RELIEF VALVES 1000 X
CLEAN SEPARATOR SCAVENGE ORIFICE 1000 X
CLEAN COOLERS CORES** 4000 X
REPLACE AIR FILTER* 2500 X
REPLACE SEPARATOR ELEMENT* 4000 X
REPLACE ULTRA COOLANT 8000 X
REPLACE SHAFT SEAL 8000 X
TIME INTERVAL (WHICHEVER COMES FIRST)
(INITIAL CHANGE ONLY)
(SUBSEQUENT CHANGES)
4.2 MAINTENANCE RECORDS
It is very important that you, the owner, keep accurateand detailed records of all maintenance work you or
the Ingersoll-Rand Distributor or Air Center perform onyour compressor.This includes, but is not limited to,coolant, coolant filter, separator element, inlet air filter,
drive belts, shaft seals and so forth.This informationmust be kept by you, the owner, should you require
warranty service work by your Ingersoll-RandDistributor or Air Center. Maintenance record sheets
are located at the back of this manual.
4.3 MAINTENANCE PROCEDURES
Before starting any maintenance, be certain the follow-
ing is heeded.
Read Safety Instructions.Have a well equipped mechanics tool box with English
and Metric sockets. (Special tools when needed will belisted under each appropriate procedure).
Have an OSHA approved air nozzle and compressedair. (International - local codes may apply).
Have recommended spare parts on hand (See listingin back of this manual.
! WARNING
When the unit is shut down, residual pressurecan be trapped within the compressor system.
This pressure must be vented from the systemprior to beginning any service work.
*IN VERY CLEAN OPERATING ENVIRONMENTS AND WHERE INLET AIR FILTER IS CHANGED ATTHE ABOVE PRESCRIBED INTERVALS.IN EXTREME
DIRTY ENVIRONMENT CHANGE DRIVE BELTS, COOLANT, FILTERS, AND SEPARATOR ELEMENTS MORE FREQUENTLY.
**CLEAN COOLER CORES IF UNIT SHUTDOWN OCCURS ON HIGH AIR TEMPERATURE.
7/27/2019 Manual de Compresor Ingersoll Rand
20/74
18
Before beginning any work on the compressor, open,lock and tag the main electrical disconnect and
close the isolation valve on the compressor dis-charge.Wait 2 minutes after stopping to allow inter-
nal pressure to dissipate.Vent residual pressurefrom the unit by slowly unscrewing the coolant fill
plug one turn. Unscrewing the fill plug opens a venthole, drilled in the plug, allowing the pressure to
release to atmosphere (See Figure4.3-1). A slight mist or oil droplets may be visibleduring venting. Do not remove fill plug until all pres-
sure has vented from the unit. Also vent piping byslightly opening the drip leg valve.When opening
the drain valve or removing the coolant fill plug,stand clear of the valve discharge, wear work glovesand appropriate eye protection.
4.4 PRESSURE RELIEF VALVE CHECKUnder normal operating condition a try lever test mustbe performed every month . Under severe service condi-tions, or if corrosion and/or deposits are noticed within
the valve body, testing must be performed more often. Atry lever test must also be performed at the end of any
non-service period. CAUTION! High pressure air willdischarge through the discharge ports of the valve
during try lever test.Wear ample clothing, gloves,safety glasses and ear protection during valve test-ing. Run the compressor for about 10 minutes by vent-
ing air from the system to let the unit warm up.With the
unit running, test at or near maximum operating pressureby holding the test lever fully open for at least 5 secondsto flush the valve seat free of debris.Then release lever
and permit the valve to snap shut. If lift lever does notactivate, or there is no evidence of discharge, discontin-ue use of equipment immediately and contact a licensed
contractor or qualified service personnel.
FIGURE 4.3-1 COOLANT FILL PLUG WITH
VENT HOLE
VENTHOLE
O-RING
7/27/2019 Manual de Compresor Ingersoll Rand
21/74
19
FIGURE 4.5-1 PARALLEL MISALIGNMENT
FIGURE 4.5-2 ANGULAR MISALIGNMENT
Align Sheaves
Ensure that the compressor is isolated from the
compressed air system by closing the isolationvalve and venting pressure from the drip leg.
Ensure that the main power disconnect switch islocked and tagged.
An easy and effective method of checking alignment inboth directions between the driver and driven sheaves
utilizes an accurate straightedge.
Lay the straightedge across the face of the driver
(motor) sheave and check alignment of the driven(airend) sheave.Then lay the straightedge across thedriven sheave and check that the driver sheave is
aligned.
Alignment should be within 1/16 (1.6 mm) maximum
when measuring the gap between the straightedgeand the rim of the opposite sheave in each direction.
This alignment is factory set and should only requireresetting if the drive motor or airend is removed.
The following steps should be taken to insure proper
alignment of all components.
1. Remove the cooler box top panel.
2. Holding the straightedge against the front of theairend sheave, measure the amount of misalignmentseen on the motor sheave. If misalignment is less than
1/16 (1.6 mm) then reinstall cooler box panel prior tooperating unit.
3. If misalignment is more than 1/16 (1.6 mm), themotor sheave bushing must be loosened for reposi-
tioning.
To reposition the motor sheave:
1. Remove drive belts (See Section 4.6).
2. Remove the three hex head screws that hold thesheave to the sheave bushing. See Figure 4.5-3.
3. Lubricate the thread and end of screws that werejust removed.
4. Reinstall all three screws in the holes of the bushingthat are threaded.
5. Slowly tighten the three screws evenly until the
sheave is pressed from the bushing. (Light tapping onbushing may assist removal.)
6. Remove the screws from the holes.
1/16 (1.6mm) MAX
1/16 (1.6mm) MAX
STRAIGHTEDGE
STRAIGHTEDGE
4.5 SHEAVE ALIGNMENT
Any degree of sheave misalignment will result in a
reduction of belt life. Misalignment of belt drive shouldnot exceed 1/16 in. (1.6 mm).
Parallel misalignment occurs when the drive and dri-ven shafts are parallel, but the two sheaves lie in dif-ferent planes (See Figure 4.5-1).
Angular misalignment occurs when the two shafts arenot parallel (See Figure 4.5-2).
7/27/2019 Manual de Compresor Ingersoll Rand
22/74
20
4.6 DRIVE BELTS
Ensure that the compressor is isolated from the
compressed air system by closing the isolationvalve and venting pressure from the drip leg.
Ensure that the main power disconnect switch islocked open and tagged.
If installing or removing the belts on a new unit at
startup, the motor support shipping bolt must first beremoved.This bolt is only used to secure the motor
support during shipment and will not be reinstalledonce the belts are put into place.
Locate the support shipping bolt as shown in Figure2.7-1 and remove.
Replacement Parts
Belts (See Recommended Spare Parts Section 7.3).
Be sure to use only Ingersoll-Rand genuine parts toassure proper belt size and length. Incorrectly sized
belts can lead to overloading of bearings and eventualairend or motor failure.
Disassembly
Belt tension is maintained due to a pivoting motor
support.The weight of the motor holds the belt tight.
1. Remove the cooler box rear panel.
2. Carefully lift the back of the motor support and
place a block of wood underneath the motor support.
3. Remove belts from the airend sheave and the
motor sheave.
Installation / Inspection
Inspect sheave grooves for foreign material or rubberbuild-up. Clean and degrease sheaves before
installing drive belts to insure long belt life.
1. Carefully lift the back of the motor support plate and
place a block of wood underneath the plate.
2. Install belts on the airend sheave and the motorsheave. When installing a new belt, do not pry or force
the belt over the sheave grooves.
3. Remove the block of wood from under the motor
support.
4.7 BELTTENSION
This unit has been designed with a unique self ten-sioning system for the drive belts.There is no adjust-
ment required to insure proper belt tensioning. Besure to use only Ingersoll-Rand Genuine parts to
assure correct belt tension.
A - Clearance HolesB - Threaded Holes
FIGURE 4.5-3 MOTOR SHEAVE BUSHING
7. Loosen allen screw in sheave bushing.
8. Move the bushing either in or out on the motor shaftdepending upon the measurement taken earlier.
9.Tighten allen screw in sheave bushing.
10. Being careful to not move the bushing on the shaft,align sheave so that the three threaded holes in the
sheave line up with the three clearance holes in thebushing.
11. Insert all three screws through clearance holes inthe bushing and thread into sheave.
12. Slowly and evenly tighten all sheave retaining
screws.Torque to 108 lb-in. (1.2 kg-m).
13.Tap against large end of bushing using hammer
and block or sleeve to avoid damage. Continue to
torque screws until the specified wrench torque nolonger turns the screw after tapping.
14. Install belts as shown in Section 4.6.
15. Recheck for proper alignment.
16. Reinstall cooler box outer panel.
ALLEN HEAD SCREWSHEAVE RETAINING SCREWS
B
B
B
A
A
A
7/27/2019 Manual de Compresor Ingersoll Rand
23/74
21
9. Remove seal housing from airend assembly. Usethe removal slots provided to pry the seal housing
from the airend. Do not attempt to break the sealhousing loose by tapping.
10. Drive each seal out of the housing, being carefulnot to damage the surface of the bore.The larger
double lip seal must be driven out toward the
inboard side.The term inboard side of the sealhousing will refer to the face that is mounted to the
airend assembly.The term outboard side will referto the face closest to the sheave.
11. Discard seals.
12. Remove check valve ball and plug from sealhousing.
13. Remove wear sleeve from shaft, being carefulnot to damage the shaft.
14.Thoroughly clean the scavenge holes, (See
Figure 4.8-1), bore surfaces of the seal housing,wear sleeve journal on the shaft, and the face of the
airend assembly.Be careful not to damage any ofthe surfaces, and insure that no particles are
allowed to enter the bearings.
FIGURE 4.8-1 SHAFT SEAL ASSEMBLY
LIP EDG
OF SEALINWARD
WEAR
SLEEVE
SCAVENGEHOLES
4.8 SHAFT SEAL REPLACEMENT
There are two lip type seals on the compressor.They
are wearable parts and should be replaced at 8,000hour intervals.While it is advisable to have your local
Ingersoll-Rand Distributor or Air Center perform thiswork, the task can be accomplished by a good mechanic
following these instructions.
Before beginning any work on the compressor,open, lock and tag the main electrical disconnect
and close the isolation valve on the compressor dis-charge.Wait 2 minutes after stopping to allow inter-
nal pressure to dissipate.Vent residual pressurefrom the unit by slowly unscrewing the coolant fillplug one turn. Unscrewing the fill plug opens a vent
hole, drilled In the plug, allowing the pressure torelease to atmosphere (See Figure 4.3-1). A slight
mist or oil droplets may be visible during venting.Do not remove fill plug until all pressure has vented
from the unit. Also vent piping by slightly opening
the drip leg valve.When opening the drain valve orremoving the coolant fill plug, stand clear of the
valve discharge, wear work gloves and appropriateeye protection.
SPECIAL TOOLS
A clean work benchSeal installation tool
REPLACEMENT PARTS
Shaft seal kit
Seal retainer 0-Ring
Loctite 609Loctite 515
Installation
1. Remove the cooler box rear panel.
2. Remove belts (See Section 4.6).
3. Remove the three hex lead screws that hold thesheave to the sheave bushing (See Figure 4.5-3).
4. Lubricate the thread and end of screws that were just
removed.5. Reinstall all three screws in the holes of the bushingthat are threaded.
6. Slowly tighten the three screws evenly until thesheave is pressed from the bushing. (Light tapping onbushing may assist removal.)
7. Remove the screws from the holes.
8. Loosen allen screw in sheave bushing.
7/27/2019 Manual de Compresor Ingersoll Rand
24/74
22
22. Using a clean flat tool that is larger in diameterthan the seal, press the single lip seal into the seal
housing until it is flush with the surface of the hous-ing.The seal must not be pushed beyond the flush
position.
23. Remove any excess Loctite 609 from the
seals, the seal housing. and from the seal scavenge
holes in the seal housing between the seals.
24. Install the plug in the bottom of the seal housing.
25. Lightly lubricate a new O-ring with clean coolantand install on the rotor shaft.
26. Insure that the surface of the seal housing isclean and dry. Put a thin continuous coat of Loctite515 on the inboard face of the seal housing. Do not
over apply.
27. Install a new check valve ball in the seal hous-
ing. A small amount of grease can be used to hold
the check valve ball in place for assembly.
28. Making sure that the check valve ball remains in
place, assemble the seal housing to the rotor hous-ing. Attach the seal housing to the rotor housing with
eight screws and tighten to 92-102 lb-in (1.07-1.19Kg-m).
29. Lightly lubricate the inner diameter and the outerdiameter of the new wear sleeve with clean com-pressor coolant.
30. Carefully slide the wear sleeve onto the rotorand through the seals until the wear sleeve locates
against the bearing.
31. Reinstall the spacer, key, sheave, and bushing.Push the bushing back against the spacer, until it
locates against the wear sleeve, when tighteningthe two bushing allen head screws to 175 Ib-in (2.0
Kg-m).
32. Reinstall belts, and check alignment per Section
4.5.
33. Reinstall cooler box outer panel.
FIGURE 4.8-2 SEAL INSTALLATION TOOL
REMOVE BURRS
1MINIMUM
15. Be certain to install the seals from the proper sideand in the proper orientation. Carefully follow directions
for seal assembly. Protect seal elements from inadver-tent damage during installation. Be sure all tools are free
of contaminants before installation.
16. Put a thin continuous coat of Loctite 609 on the
outer diameter of the double lip seal.
17. Position the seal in the seal housing from theinboard side.The seal should be oriented such that the
edge of the lip is toward the installer.
18. Using the seal installation tool (machined accordingto Figure 4.8-2), press the double lip seal into the seal
housing until it locates against the shoulder.
19. Remove any excess Loctite 609 with a clean cloth.
20. Put a thin continuous coat of Loctite 609 on the
outer diameter of the single lip seal.
21. Position the seal in the seal housing from the out-
board side.The seal should be oriented such that theedge of the lip is installed first.
7/27/2019 Manual de Compresor Ingersoll Rand
25/74
23
4.9 INLET AIR FILTER ELEMENT
The inlet air filter element should be changed at theinterval shown in the maintenance chart or any time
the filter becomes dirty.
The filter element is not washable and must be
replaced. Remove air filter housing top cover. Remove
air filter element. Install new element and replace topcover. (See Figure 4.9-1).
FIGURE 4.9-1 INLET AIR FILTER
4.10 COOLANT FILTER
Time of change - after the first 150 hours and every2000 hours thereafter, or when the coolant is being
changed. In dirty operating environments, the filtershould be changed more frequently.
Before beginning any work on the compressor,open, lock and tag the main electrical disconnect
and close the isolation valve on the compressordischarge.Wait 2 minutes after stopping to allowinternal pressure to dissipate.Vent residual pres-
sure from the unit by slowly unscrewing the
coolant fill plug one turn. Unscrewing the fill plugopens a vent hole, drilled in the plug, allowing thepressure to release to atmosphere (See Figure 4.3-
1). A slight mist or oil droplets may be visible dur-ing venting. Do not remove fill plug until all pres-sure has vented from the unit. Also vent piping by
slightly opening the drip leg valve.When openingthe drain valve or removing the coolant fill plug,
stand clear of the valve discharge, wear workgloves and appropriate eye protection.
Special Tools
Suitable clean drain pan or container to hold coolant
drained from unit.
A quantity of proper coolant sufficient to top off the
coolant level in the compressor.
One genuine IR replacement coolant filter of the prop-
er type for the unit.
Procedure
1. Place a clean pan under the coolant filter.
2. Using a filter wrench, remove the coolant filter.
Remember that the filter and coolant may be hot!
3. Discard the old filter.
4.Wipe the sealing surface of the filter housing with a
clean lint-free rag to prevent entry of dirt into the sys-tem.
5. Remove the replacement filter from its protectivepackage.
6. Apply a small amount of clean coolant on the rubber
seal of the filter.
7. Screw filter on until the seal makes contact with the
head of the filter housing.Tighten approximately onehalf to three quarters turn additional.
8. Remove coolant fill plug (See Figure 4.10-1).
FIGURE 4.10-1 SEPARATOR TANK
TOP COVER
COOLANT FILL PLUG
7/27/2019 Manual de Compresor Ingersoll Rand
26/74
24
9. Fill unit with new coolant as follows:a. Fill tank to the bottom of the threads in the
coolant fill port.b. Replace fill plug.
c. Run compressor 15-20 seconds.d. Stop compressor and relieve pressure by
slowly unscrewing the coolant fill plug oneturn. Do not remove fill plug until all pressure
has vented.e. Add more coolant up to the bottom of the
threads of the coolant fill port.
f. Replace fill plug.g. Start the compressor and verify coolant level
is in the bottom half of the sight glass(See Figure 4.11-1) when the compressor isrunning unloaded. Check for leaks.
Do not add coolant through the intake of the compres-
sor, as this can result in overfilling, saturation of the sep-arator filter element, and coolant carry-over downstream.
4.11 COOLANT CHANGE
Before beginning any work on the compressor,open, lock and tag the main electrical disconnectand close the isolation valve on the compressor
discharge.Wait 2 minutes after stopping to allowinternal pressure to dissipate.Vent residual pres-
sure from the unit by slowly unscrewing thecoolant fill plug one turn. Unscrewing the fill plug
opens a vent hole, drilled in the plug, allowing thepressure to release to atmosphere (See Figure4.3-1). A slight mist or oil droplets may be visible
during venting. Do not remove fill plug until allpressure has vented from the unit. Also vent pip-
ing by slightly opening the drip leg valve.Whenopening the drain valve or removing the coolant
fill plug, stand clear of the valve discharge, wearwork gloves and appropriate eye protection.
Special Tools
Suitable clean drain pan or container to hold approxi-
mately 1.5 gal. (5.75 L) of coolant drained from unit.
A quantity of proper coolant sufficient to refill the
coolant level in the compressor.
One genuine IR replacement coolant filter of theproper type for the unit.
ProcedureThe coolant should be drained soon after the com-
pressor has been shut down. When the coolant iswarm, the drainage will be more complete and any
particles in suspension in the coolant will be carriedout with the coolant.
7/27/2019 Manual de Compresor Ingersoll Rand
27/74
25
FIGURE 4.11-1 COOLANT DRAIN VALVE
COOLANT DRAIN VALVE
SIGHT GLASS
11. Remove coolant fill plug (See Figure 4.10-1).
12. Fill unit with new coolant as follows:
a. Fill tank to the bottom of the threads of thecoolant fill port.
b. Replace fill plug.c. Run compressor 15-20 seconds.
d. Stop compressor and relieve pressure byslowly unscrewing the coolant fill plug oneturn. Do not remove fill plug until all pressure
has vented.e. Add more coolant up to the bottom of the
threads of the coolant fill port.f. Replace fill plug.
g. Start the compressor and verify coolant level
is in the bottom half of the sight glass(See Figure 4.11-1) when the compressor is
running unloaded.Check for leaks.
Do not add coolant through the intake of the compres-sor, as this can result in overfilling, saturation of the sep-arator element, and coolant carry-over downstream.
4.12 COOLANT HOSE
The flexible hose that carries coolant to the airend maybecome brittle with age and will require replacement.
Have your local Ingersoll-Rand Distributor or Air Centercheck it every year, and replace as needed or every 2years.
Before beginning any work on the compressor,
open, lock and tag the main electrical disconnectand close the isolation valve on the compressor dis-charge.Wait 2 minutes after stopping to allow inter-nal pressure to dissipate.Vent residual pressure
from the unit by slowly unscrewing the coolant fillplug one turn. Unscrewing the fill plug opens a vent
hole, drilled in the plug, allowing the pressure torelease to atmosphere (See Figure 4.3-1). A slight
mist or oil droplets may be visible during venting.Do not remove fill plug until all pressure has ventedfrom the unit. Also vent piping by slightly opening
the drip leg valve.When opening the drain valve orremoving the coolant fill plug, stand clear of the
valve discharge, wear work gloves and appropriateeye protection.
Removal
Drain coolant into a clean container. Cover the container
to prevent contamination. If the coolant is contaminated,a new charge of coolant must be used.
Remove the hose.
3.Thread the coolant drain fitting (supplied with com-pressor), with hose attached, onto the coolant drainvalve.The valve will open as the fitting is inserted
allowing the coolant to drain.
4. Using a filter wrench, remove the coolant filter.Remember that the coolant filter may be hot!
5. Discard the old filter.
6. Wipe the sealing surface of the filter head with aclean lint-free rag to prevent entry of dirt into the sys-
tem.
7. Remove the replacement filter from its protectivepackage.
8. Apply a small amount of clean coolant on the rub-
ber seal of the filter.
9. Screw element on until the seal makes contact with
the seat on the filter header.Tighten approximatelyone half to three quarters turn additional.
10. Remove drain fitting and replace drain valve cap.
1. Place a clean pan under the coolant drain valve.
2. Remove the cap from the coolant drain valve(See Figure 4.11-1).
7/27/2019 Manual de Compresor Ingersoll Rand
28/74
26
Before beginning any work on the compressor,open, lock and tag the main electrical disconnect
and close the isolation valve on the compressordischarge.Wait 2 minutes after stopping to allow
internal pressure to dissipate.Vent residual pres-sure from the unit by slowly unscrewing the
coolant fill plug one turn. Unscrewing the fill plugopens a vent hole, drilled in the plug, allowing the
pressure to release to atmosphere (See Figure 4.3-1). A slight mist or oil droplets may be visible dur-ing venting. Do not remove fill plug until all pres-
sure has vented from the unit. Also vent piping byslightly opening the drip leg valve. When opening
the drain valve or removing the coolant fill plug,stand clear of the valve discharge, wear workgloves and appropriate eye protection.
Procedure:
1. Disconnect tank discharge fitting, inlet valve controltubing, and scavenge tube.
2. Remove tank cover bolts and cover (See Figure4.13-2).
3. Remove separator element.
4. Clean all tank flange surfaces of dirt and residual
gasket material.
5. Install new separator element, making sure that the
grounding staple comes in contact with the flangematerial.
FIGURE 4.13-2 TANK COVER REMOVAL
BOLT
Installation
Install the new hose. Refill the unit with coolant. Start
the compressor and check for leaks. Stop unit andcheck coolant level in the sight glass on the separator
tank.
4.13 COOLANT SEPARATOR ELEMENT
The separator element should be replaced every yearor after 4000 hours of operation, whichever comes
first, to prevent excessive coolant carryover into theplants air piping system.
The element is located inside the separator tank (SeeFigure 4.13-1).
FIGURE 4.13-1 SEPARATOR ELEMENT LOCATION
SEPARATOR ELEMENT (INSIDE)
7/27/2019 Manual de Compresor Ingersoll Rand
29/74
27
4.15 COOLER CORES/CLEANING
Inspection
Visually check the cooler cores for build up of dirt,dust, lint or other foreign material.
Using an OSHA approved air gun, blow air through thecooler cores in the opposite direction of normal air
flow.
Remove cooler box rear panel and clean all loosematerial that blew from the coolers into the fans.
Reinstall the cooler box rear panel.
Start unit and verify proper operation.
4.16 MOTOR BEARING MAINTENANCE-
STORED UNITS
THE MOTOR BEARINGS ARE PERMANTLY LUBRI-
CATED AND DO NOT REQUIRE RE-LUBRICATION.
To ensure that complete contact is maintainedbetween the motor bearings and the bearing grease
on units to be placed in storage for extended intervals,the following motor maintenance procedure should be
adhered to:
1. Prior to placing a unit in storage, rotate the motorseveral revolutions by hand in the proper direction of
rotation.
2.Thereafter, rotate the motor as described in Step 1
at three month intervals until such time as the unit is
placed in service.
6. Replace cover and start the retaining bolts.
7.Torque bolts evenly to 80 ft.-lb (109 N-m).
8. Replace connections removed in step 1.
9. Start unit and check for leaks.
4.14 SEPARATOR TANK SCAVENGECHECK VALVE/SCREEN/ORIFICE
Tools Required
Open end wrench
Screwdriver
Procedure
Disconnect tubing at each end of check valve/screen/orfice assembly.
Check orifice and clean if required. Use suitable tooland remove screen/orifice end from its housing (SeeFigure 4.14-1). Be careful not to damage flared end of
fitting or O-ring. Wash screen and housing in safetysolvent and blow dry.
Press the check valve/screen/orifice into fitting block.
Assemble the check valve/screen/orifice assembly to
the tubing lines.The fitting must be re-installed withthe screen on the upstream side of the orifice as indi-cated by the flow arrow (See Figure 4.14-1).
FIGURE 4.14-1 SEPARATOR TANK SCAVENGECHECK VALVE/SCREEN/ORIFICE
INLET
SPRINGHOUSING
CHECKVALVE
SCREEN ORIFICE
VITONO-RING
7/27/2019 Manual de Compresor Ingersoll Rand
30/74
28
5.0 TROUBLE SHOOTING
TROUBLE CHECK POINT NUMBERS
Compressor Fails to Start 1,2,3Repeat Shutdowns 3,4,5,2High Amp Draw 8,9,6,7
Low Amp Draw 1,10,12High Discharge Pressure 13,15,16,19
Low Air System Pressure 22, 20,17,18,13,15,14,19,7Unit Running Hot 22,21,23,24,6
High Coolant Consumption 28,27,25,26Excessive Noise Level 17,18,31,30,29Shaft Seal Leak 32
Pressure Relief Valve Opens 6,13,15,14,16,19Black Residue on Belt 17,33,34
Guard/Cooler Box
CHECK POINT NUMBERS TROUBLE CAUSE1. Control Voltage Not Available2. Defective Starter
3. Motor Overload4. Incorrect Overload Size
5. Line Voltage Variation6. Compressor Operating Above Rated Pressure7. Dirty Separator Element
8. Low Voltage9. Unbalanced Voltage
10. Dirty Air Filter11. Compressor Operating Unloaded
12. High Voltage
13. Incorrect Pressure Switch Setting14. Faulty Minimum Pressure Valve
15. Load Solenoid Valve Defective16. Blowdown Valve Defective
17. Drive Belts Slipping18. Air System Leaks
19. Inlet Valve Malfunction20. System Demand Exceeds Compressor Delivery21. Coolant Cooler Core Dirty
22. Low Coolant Level23. High Ambient Temperature
24. Restricted Cooling Air Flow25. Separator Element Leak
26. Plugged Separator Scavenge/Orifice27. Compressor Operating Below Rated Pressure
28. Coolant System Leak29. Airend Defective30. Motor Defective
31 Loose Components32 Worn or Defective Shaft Seal
33 Sheaves Misaligned34 Worn Sheaves
7/27/2019 Manual de Compresor Ingersoll Rand
31/74
29
6.0 REFERENCE DRAWINGS39914643REV 01
6.1 ELECTRICAL SCHEMATIC - FULL VOLTAGE
7/27/2019 Manual de Compresor Ingersoll Rand
32/74
30
6.2ELECTRICALSCH
EMATIC
-STAR-DELTA
7/27/2019 Manual de Compresor Ingersoll Rand
33/74
31
6.3PIPINGDIAGRAM
7/27/2019 Manual de Compresor Ingersoll Rand
34/74
32
6.4FOUNDATION
PLAN-80GALTANK
MOUNTED
-E
NCLOSED
(CONTINUED)
7/27/2019 Manual de Compresor Ingersoll Rand
35/74
33
6.4FOU
NDATION
PLAN
-80GALTANK
MOUNTED
-ENCLOSED
7/27/2019 Manual de Compresor Ingersoll Rand
36/74
34
6.5FOUNDATION
PLAN-80GALTANK
MOUNTED
-UNENCLOSED
(CONTINUED)
7/27/2019 Manual de Compresor Ingersoll Rand
37/74
35
6.5 FOUNDATION PLAN - 80 GAL TANK MOUNTED - UNENCLOSED
7/27/2019 Manual de Compresor Ingersoll Rand
38/74
36
6.6FOUNDATION
PLAN-120GALTANK
MOUNTED
-ENCLOSED
(CONTINUED)
7/27/2019 Manual de Compresor Ingersoll Rand
39/74
37
6.6 FOUNDATION PLAN - 120 GAL TANK MOUNTED - ENCLOSED
7/27/2019 Manual de Compresor Ingersoll Rand
40/74
38
6.7FOUNDATION
PLAN-120GALTANK
MOUNTED
-UNENCLOSED
(CONTINUED)
7/27/2019 Manual de Compresor Ingersoll Rand
41/74
39
6.7FOUNDA
TION
PLAN
-120GALTANK
MO
UNTED
-UNENCLOSED
7/27/2019 Manual de Compresor Ingersoll Rand
42/74
40
6.8FOUNDATION
PLAN-BASEMOUNTED
-ENCLOS
ED
(CONTINUED)
7/27/2019 Manual de Compresor Ingersoll Rand
43/74
41
6.8FOUNDATION
PLAN
-BASEMOUNTED
-ENCLOSED
7/27/2019 Manual de Compresor Ingersoll Rand
44/74
42
6.9 FOUNDATION PLAN - BASE MOUNTED - UNENCLOSED (CONTINUED)
7/27/2019 Manual de Compresor Ingersoll Rand
45/74
43
6.9
FOUNDATION
PLAN
-BASEMO
UNTED
-UNENCLOSED
7/27/2019 Manual de Compresor Ingersoll Rand
46/74
44
6.10 TYPICAL SYSTEM FLOW DIAGRAM (TWO BASE PLATE MOUNTED UNITS)
FUTURE
COMP.
ISOLATION
VALVE
PRE FILTERAFTERFILTER
DRYER
TOP
TO
SYSTEM
OUTSIDE
COMPRESSORROOM
RECEIVER
BOT
PRE FILTER
GLADHAND Emergency Standby Air Hook Up.Complete with Necessary Fitting For Portableor IR Rental Air Unit From Local IRDistributor
VALVE Water, Or Ball Type Valve
UNION Aids in Disconnecting Compressor From The System
PRESSURE GAUGE
DRIP LEG
MANOMETER
DIFFERENTIAL PRESSURE INDICATOR
THERMOMETER
I-R AUTOMATIC DRAIN VALVE
FALSE LOADER Blows Off Air Outside Of Compressor Room
SYSTEM INSTRUMENTATION INCLUDES
Nephelometer;Hygrometer;Pressure;Temperature
VENTILATION Moisture Louvers, Exhaust Fans
AFTERCOOLER/SEPARATOR, ISOLATION VALVE, UNION, STRAINER AND TRAP
7/27/2019 Manual de Compresor Ingersoll Rand
47/74
45
7.0 PARTS LIST
7.1 INTRODUCTION
GENERALThis manual, which contains an
illustrated parts breakdown, hasbeen prepared as an aid in identify-
ing and ordering parts for the SSRcompressor. All of the compressor
parts, listed in the parts break-down, are manufactured with thesame precision as the original
equipment.
Ingersoll-Rand Company servicefacilities and parts are available
worldwide.There are Ingersoll-Rand Company Branch Offices andauthorized distributors located in
the principle cities of the UnitedStates. In Canada, our customers
are serviced by the CanadianIngersoll-Rand Company, Limited.
There are also Ingersoll-RandCompany subsidiaries and autho-rized distributors located in the
principle cities throughout theworld.
DESCRIPTION
The illustrated parts breakdown
illustrates the various assemblies,sub-assemblies and detailed partswhich make up this particular
SSR compressor. A series of illus-trations show each part clearly and
in its correct location relative to theother parts in the illustration. Each
part of an illustration is referencedwith a number.The number,
description and quantity neededper assembly are listed in numeri-
cal order on the following pages.
Items with a description of NSS are
not sold separately and must bepurchased as an assembly. Items
with a description of Ref. indicatethat the item is located elsewherein the parts list.
HOW TO USE THIS
PARTS MANUAL
1. Turn to the Parts Section tolocate desired illustrations.
2. Locate the part on the illustrationby visual identification and the ref-
erence number.
3. Find the reference number onthe Tabulated page, along with thePart Number and Description.
SERIAL NUMBER BREAKWhen a part is changed and it
doesnt supersede the previouspart, this change must be docu-
mented by a serial number break.By using the last six (6) digits of
the serial number, as outlinedbelow, this change is recorded in
the parts list.
U99202 indicates part is used
on units up to and including serialnumber ending in U99202.
U99203 indicates part is usedon units with serial number ending
in U99203 or higher.
HOW TO ORDER PARTS
In order that all avoidable errors beeliminated when ordering parts,please specify the following:
1.The model number of the unit as
shown on the Compressor DataPlate.
2.The serial number of the unit asshown on the Compressor Data
Plate.
3.The form number of this manual.
4.The reference number, part num-ber, description and quantity need-ed exactly as listed.
5.The motor data code shown on
the motor data plate.
LX0000 U 99 202
MANUFACTURED IN U.S.
YEAR OF MANUFACTURE
JULIAN DATE OF MANUFACTURE
7/27/2019 Manual de Compresor Ingersoll Rand
48/74
46
7/27/2019 Manual de Compresor Ingersoll Rand
49/74
47
7/27/2019 Manual de Compresor Ingersoll Rand
50/74
48
7/27/2019 Manual de Compresor Ingersoll Rand
51/74
49
7/27/2019 Manual de Compresor Ingersoll Rand
52/74
50
7/27/2019 Manual de Compresor Ingersoll Rand
53/74
51
7/27/2019 Manual de Compresor Ingersoll Rand
54/74
52
7/27/2019 Manual de Compresor Ingersoll Rand
55/74
53
7/27/2019 Manual de Compresor Ingersoll Rand
56/74
54
7/27/2019 Manual de Compresor Ingersoll Rand
57/74
55
NOTE:
7/27/2019 Manual de Compresor Ingersoll Rand
58/74
56
7/27/2019 Manual de Compresor Ingersoll Rand
59/74
57
7/27/2019 Manual de Compresor Ingersoll Rand
60/74
58
7/27/2019 Manual de Compresor Ingersoll Rand
61/74
7/27/2019 Manual de Compresor Ingersoll Rand
62/74
60
7/27/2019 Manual de Compresor Ingersoll Rand
63/74
61
7/27/2019 Manual de Compresor Ingersoll Rand
64/74
62
7/27/2019 Manual de Compresor Ingersoll Rand
65/74
63
7/27/2019 Manual de Compresor Ingersoll Rand
66/74
64
7/27/2019 Manual de Compresor Ingersoll Rand
67/74
65
7/27/2019 Manual de Compresor Ingersoll Rand
68/74
66
7/27/2019 Manual de Compresor Ingersoll Rand
69/74
7/27/2019 Manual de Compresor Ingersoll Rand
70/74
68
O-RINGS FOR SAE FITTINGS
Part Size/ TubeNo. Thread ID Width Size
39404157 7/16-20 0.351 0.072 1/439404132 9/16-18 0.468 0.078 3/839404165 3/4-16 0.644 0.087 1/239437074 7/8-14 0.755 0.097 5/8
39407531 1- 1/16-12 0.924 0.116 3/439404173 1- 5/16-12 1.171 0.116 139404140 1- 5/8-12 1.475 0.118 1-1/439406996 1- 7/8-12 1.720 0.118 1-1/239410279 2- 1/2-12 2.337 0.118 2
7/27/2019 Manual de Compresor Ingersoll Rand
71/74
69
7.3 SERVICE AND OPTION KITS
Service Kits:
Part Number Description Models
42448456 *Kit, Maintenance Units with Uncoded Separator Tank42474692 *Kit, Maintenance Units with ASME/CRN Separator Tank
Option Kits:
Part Number Description
42457721 Kit, Field - Power Outage Restart (PORO)42455865 Kit, Field - High Dust Air Filter
42448753 Kit, Field - Enclosure42471094 Kit, Field - 80 Gallon Receiver Tank42471102 Kit, Field - 120 Gallon Receiver Tank
* Contains (1) oil filter, (1) air filter, (1) separator element, and (5) gallons of Ultracoolant
7/27/2019 Manual de Compresor Ingersoll Rand
72/74
70
7.4 RECOMMENDED SPARE PARTS LIST
I-R QTYCOMPRESSOR PART DESCRIPTION PART PER
NO. UNIT
Maintenance Kit (Units with Uncoded Tank) 42448456 1
Maintenance Kit (Units with ASME/CRN Coded Tank) 42474692 1Ultra Coolant (5 gal.Container) 39433735 1Air Filter Element 88171913 1Coolant Filter 39329602 1Coolant Separator Element (Uncoded Tank) 39900923 1Coolant Separator Element - (ASME/CRN Coded Tank) 39912969 1V-Belt, 42.5 39204714 **V-Belt, 45.0 39204722 **V-Belt, 47.5 39204730 **Inlet Valve Rebuild Kit 39257514 1Inlet Valve O-Ring 95022117 1Load Solenoid Valve (1SV) - NEMA 1 39583943 1Load Solenoid Valve (1SV) - NEMA 4 39492566 1Blowdown Solenoid Valve (3SV) 39492558 1Shaft Seal Kit 42412197 1Thermostatic Control Element 39441944 1High Air Temperature Switch (HATS) 39416128 1
O-ring, HATS 39404157 1Orifice, CheckValve / Filter 39303219 1Combination Oil Cooler / Aftercooler 39899893 1Minimum Pressure CheckValve (MPCV) 39490693 1Hose, MPCV to Aftercooler In 39571872 1Hose, Aftercooler Out to Receiver Tank (120 Gal.Tank) 39571922 1Hose, Aftercooler Out to Receiver Tank (80 Gal.Tank) 39571963 1Hose, Oil Filter to Airend Injection 39572003 1Control Relay 39255559 2Start Switch Operator 39255609 1Start Switch Contact Block 39255633 1Stop Switch Operator 39255625 1Stop Switch Contact Block 39255641 1Auto Restart Indicator Light 39255666 1Power On Indicator Light 39243985 1Auto Restart Timer Relay 39255567 1Pressure Gauge 39499256 1Pressure Switch 39439740 1Starter Contactor Assembly, Size C16 39255518 1*Starter Contactor Assembly, Size C23 39333257 1*Starter Contactor Assembly, Size C30 39252010 1*Starter Contactor Assembly, Size C43 39250998 1Starter Contactor Assembly, Size C60 39251004 1Reversing Starter Contactor Assy, Size C16 39255518 1*Mechanical Interlock (Star-Delta) 39251186 1Starter Overload Relay, EA5FB (1OL) 39255542 1Starter Overload Relay, EA5GB (1OL) 39255591 1Starter Overload Relay, EA5HC (1OL) 39251988 1Starter Overload Relay, EA5JD (1OL) 39251079 1Starter Overload Relay, EA5KE (1OL) 39251087 1Auxiliary Contact, 2 N.O. 39255492 1Hourmeter, 60 Hz 39226618 1Hourmeter, 50 Hz 39233382 1Relief Valve (Separator Tank) 39588082 1Relief Valve (Receiver Tank) 39588017 1Cooling Fan (7-1/2 & 10 HP) 39858485 2Cooling Fan (15 HP) 39858485 3Fuse, FU1 / FU2 39239355 2Fuse, FU3 39113527 1Control Circuit Transformer 39233408 1Decal Kit (English) 39256730
* QUANTITY IS (2) FOR STAR-DELTA
** BELT SIZE AND QUANTITY VARYWITH HORSEPOWER AND PRESSURE RATING.CONTACT YOUR LOCAL INGERSOLL-RANDDISTRIBUTOR IF ASSISTANCE IS NEEDED FOR BELT REPLACEMENT.
7/27/2019 Manual de Compresor Ingersoll Rand
73/74
71
DATE RUN TIME WORK DONE QTY. UNIT WORK
(HOURS) MEASURE BY
8.0 MAINTENANCE RECORD
7/27/2019 Manual de Compresor Ingersoll Rand
74/74
DATE RUN TIME WORK DONE QTY. UNIT WORK
(HOURS) MEASURE BY
MAINTENANCE RECORD