2
5147 Alhambra Ave. Los Angeles CA 90032 P. 323.221.9137 F. 323.221.2579 www.arrowheadbrass.com MANUFACTURED IN CALIFORNIA SINCE 1936 Hot & Cold Frost-Free An-Siphon Hydrant 490BFP Series Hot & Cold Mixing Frost-Free Hydrant An-Siphon Self-Draining Vacuum Breaker Allows faucet to Drain upon Shut-Off Available in Horizontal or Vercal (“V”) Models Nickel Plated Brass Body and Copper Tubes Color Coded Metal Handles and Stainless Steel Screws Exclusive “No-Leak” O-Ring Seal, One-Piece Bonnet & Stem Assembly Factory-installed vacuum breaker prevents tampering & use if device is removed Standard stem lengths 2” - 14” Max. 140°F – 125 PSI 9-10 GPM at 50 PSI ASSE 1019 Approved, IAPMO Listed 3 Year Warranty; Made in USA from domesc and foreign components Not designed for constant pressure applicaons An-Siphon Vacuum Breaker required, non-removable. Not for potable water applicaons, product contains lead & other potenally harmful chemicals Features [TS.490] Series Inlet Connection 491 3/4” Wirsbo ® WPX 492 1/2” Wirsbo ® WPX 493 3/4” Push-Fit* 494 1/2” Push-Fit* 495 3/4” MIP OR 1/2” FIP 496 1/2” Sweat OR 1/2” MIP 497 3/4” PEX 498 3/4” Sweat OR 3/4” MIP 499 1/2” PEX Hot & Cold Hydrant Models Vercal Hot & Cold Hydrant Models (“V” Series) Standard Hot & Cold Hydrant Models *Push-Fit Connecons are NOT Removable. Faucet seat is built-in to adapter.

MANUFACTURED IN CALIFORNIA SINCE 1936 Hot & Cold Frost

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MANUFACTURED IN CALIFORNIA SINCE 1936 Hot & Cold Frost

5147 Alhambra Ave. Los Angeles CA 90032P. 323.221.9137 F. 323.221.2579 www.arrowheadbrass.com

MANUFACTURED IN

CALIFORNIA SINCE 1936

Hot & Cold Frost-Free Anti-Siphon Hydrant490BFP Series

• Hot & Cold Mixing Frost-Free Hydrant• Anti-Siphon Self-Draining Vacuum Breaker Allows

faucet to Drain upon Shut-Off• Available in Horizontal or Vertical (“V”) Models• Nickel Plated Brass Body and Copper Tubes• Color Coded Metal Handles and Stainless Steel Screws• Exclusive “No-Leak” O-Ring Seal, One-Piece Bonnet &

Stem Assembly • Factory-installed vacuum breaker prevents tampering

& use if device is removed• Standard stem lengths 2” - 14”• Max. 140°F – 125 PSI• 9-10 GPM at 50 PSI• ASSE 1019 Approved, IAPMO Listed• 3 Year Warranty; Made in USA from domestic and

foreign components• Not designed for constant pressure applications• Anti-Siphon Vacuum Breaker required, non-removable.• Not for potable water applications, product contains

lead & other potentially harmful chemicals

Features

[TS.490]

Series Inlet Connection

491 3/4” Wirsbo® WPX

492 1/2” Wirsbo® WPX

493 3/4” Push-Fit*

494 1/2” Push-Fit*

495 3/4” MIP OR 1/2” FIP

496 1/2” Sweat OR 1/2” MIP

497 3/4” PEX

498 3/4” Sweat OR 3/4” MIP

499 1/2” PEX

Hot & Cold Hydrant Models

Vertical Hot & Cold Hydrant

Models(“V” Series)

Standard Hot & Cold Hydrant

Models

*Push-Fit Connections are NOT Removable. Faucet seat is built-in to adapter.

Page 2: MANUFACTURED IN CALIFORNIA SINCE 1936 Hot & Cold Frost

5147 Alhambra Ave. Los Angeles CA 90032P. 323.221.9137 F. 323.221.2579 www.arrowheadbrass.com

MANUFACTURED IN

CALIFORNIA SINCE 1936

2-1/2”Horizontal Models: Width 5”

On center3-1/4”

Standard Hydrant Lengths: 2”, 4”, 6”, 8”, 10”, 12”, 14”

3-1/2”1”- 2”

Depending on Inlet Type

2-1/2” 4-1/4”

Standard Stem Lengths: 2”, 4”, 6”, 8”, 10”, 12”, 14”

Model Stem Length Plus 5”

Vertical Models:Height 7”

Illus. # Description Part ##1 Red Oval Handle 11R#1 Blue Oval Handle 11B

#2 Stainless-Steel Self-Tapping Screw for Handles 8

#3 Hot & Cold Stem & O-Ring Bonnet Replacement (Horizontal)

PK9004 through PK9014

Hot & Cold Stem & O-Ring Bonnet Replacement (Vertical)

PK9004V through PK9014V

#4 Self-Draining Vacuum Breaker(Horizontal)

PK1390 or 59BF-PCHR

#5 Self-Draining Vacuum Breaker Lower Half(Vertical) 59RVB

#5 Self-Draining Vacuum Breaker with 490 Vertical Adapter 59BFPHCVSUBP

#6 Seat Washer 5#7 Stainless Steel Seat Washer Screw 6

Replacement Parts

Arrowhead Brass & Plumbing, LLCReliable - Proven - Trusted - Since 1936

WARNING! When using a hose with a self-closing nozzle, always relieve pressureby draining the hose upon water shutoff to activate the drainage of the hydrant.

#1

#2

#3#4

#6 #7

#5

59BFPCHR