Manufacturing / Fabrication Hospitals & Health Care
Facilities Fireproofing Residential/Commercial Retail / Commercial
Facilities Food & Beverage Processing Maintenance Oil & Gas
Water & Wastewater Facilities Industries Served Services
Offered Project Inspection Coating Recommendation Failure Analysis
Free Technical Service Job Site Training Specification Writing
Danny Janulek Idaho, Nevada & Northern California (650)
622-6509 [email protected][email protected] Steve
Sexton Northern & Central California (925) 984-5036
[email protected]@kellymoore.com Greg Sutton Texas,
Oklahoma & Arkansas (918) 625-2538
[email protected]@kellymoore.com Trusted and preferred
by professionals since 1946 we are known for our commitment to
quality, performance and consistency.
Slide 3
Contego Passive Fire Barrier (PFB)
Slide 4
1.(SFRM) Spray Applied Fire Resistive Material 2.(PFB) Passive
Fire Barriers 3.(PFP) Passive Fire Protection (UL1709)
Slide 5
Monokote Monokote is a gypsum based cementitious spray-applied
fire resistive material for structural steel framed buildings The
term cementitious as defined by ASTM or Underwriters Laboratories
Inc. applies to all fireproofing that is wet mixed and then pumped
as a slurry. Cementitious does not refer to portland cement
content.
Slide 6
There are two basic categories of Architectural Fireproofing,
Residential and Commercial applications. These products usually
consist of a thin-film latex or solvent based material.
Slide 7
There are two basic types of industrial fireproofing
cementitious and epoxy intumescent. These products are usually
designed to meet UL1709 Cementitious fireproofing is a cement-based
material that provides fire protection through its inherent
insulative properties. Epoxy intumescent fireproofing has the
appearance and application characteristics of a protective
coating.
Slide 8
Materials including structural steel, aluminum, dimensional
lumber, manufactured wood products, trusses, drywall, spray
polyurethane foam insulation, HDPE wall panels, concrete, plaster,
solid core doors and more. The product may also be used for
conduit, decking and cladding.
Slide 9
Intumescent Fireproofing Systems allow designers to express the
steel structure as an art form in buildings where fire resistance
ratings are required. Project planners now have flexibility to
create unique exposed steel designs where fire resistance ratings
are required, with aesthetically pleasing, durable and cost
effective alternatives.
Slide 10
Decorative Thin Film Coating 1, 2 and 3 Hour Fire Ratings 0
V.O.C. /Non-Toxic Excellent Durability High Impact Strength
Provides A Clean Dust Free Environment Easy Paint-Like Application
Suitable For Top coating with any KM Paint Marketable to our
Painting Contractors Direct Manufacturer Support
Slide 11
Tested to 9 ASTM International Standards: ASTM D 1475 -
Standard Test Method For Density of Paint, Varnish, Lacquer, and
Related Products. ASTM D 2369 - Standard Test Method For Volatile
Content of Coatings. ASTM D 3359 - Standard Methods for Measuring
Adhesion by Tape Test (Methods A and B) ASTM D 3960 - Standard
Practice for Determining Volatile Organic Compound (VOC) Content of
Paints and Related Coatings. ASTM D 4017 - "Standard Test Method
for Water in Paints and Paint Materials by Karl Fischer Method.
ASTM E 84 - Standard Test Method for Surface Burning
Characteristics of Building Materials. ASTM E 119 - Standard Test
Methods for Fire Tests of Building Construction and Materials. ASTM
E 283 - Standard Test Method for Determining Rate of Air Leakage
Through Exterior Windows, Curtain Walls, and Doors Under Specified
Pressure Differences Across the Specimen. ASTM E 662 - Standard
Guide for Measurement of Gases Present or Generated During
Fires.
Slide 12
ONE HOUR PROTECTION 1 HOUR RATINGS W Shapes - Wide Flange Beams
and ColumnsTotal DFTCoverageRequiredMinimum Linear Ft.Square
Ft.Mils(Sq. Ft./Gal.)GallonsCoats Section*W/D**ft.2/ft
W12x220.5603.28384.001259.52 6415.0083.973
W12x160.4103.251178.003828.50 8810.91350.954 Sub Tot434.91 L Shapes
- Angles Total DFTCoverageRequiredMinimum Linear Ft.Square
Ft.Mils(Sq. Ft./Gal.)GallonsCoats Section*W/D**ft.2/ft
L6x6x1/20.8241.98510.001009.80 2243.6423.141
L5x3x1/40.4181.3292.00121.44 4322.335.442
L4x4x3/80.6151.3261.0080.52 2933.102.432
L4x4x1/40.4161.3266.0087.12 4322.333.902
L3x3x3/80.6080.98142.00139.59 3032.004.362
L3x3x1/40.4140.98526.00517.06 4421.8223.702 497.89 TOTAL Firefilm
722 gallons
Sample thickness required for 2 Hour application: Beam
TypeFIREFILMCONTEGO W10x49 N ot possible (Design X641)77 mils HSS
8x8x.500 186 mils (Design X642) 42 mils Winner! A/D Firefilm
III
Slide 15
Great Western Painting Commercial & Industrial Painting.
Serving the U. S. A. Water Towers -Tanks - Hotels Chemical plants -
High Rises - Structural Steel 1 - 877-749-5554
[email protected] Thank You