VA 50
Primary (Volts) 120 / 240
Secondary (Volts) 12 / 24
Input /Output Amps 0.42 , 0.21 / 4.17 , 2.08
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 50 / 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50A
Notes:
H1-H4
120
240
INTERCONNECT:
H1-H3 AND H2-H4
H2-H3
VOLTS
12
24
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
H1-H4
X1-X4
CONNECTION DIAGRAM
H4 H1
X1 X3
X2 X4
H2H3
0V
0V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 120 / 240
Secondary (Volts) 120 / 240
Input /Output Amps 0.42 , 0.21 / 0.42 , 0.21
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 50 / 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50B
Notes:
H1-H4
120
240
INTERCONNECT:
H1-H3 AND H2-H4
H2-H3
VOLTS
120
240
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
H1-H4
X1-X4
CONNECTION DIAGRAM
H4 H1
X1 X3
X2 X4
H2H3
0V
0V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 208 / 416
Secondary (Volts) 12 / 24
Input /Output Amps 0.24 , 0.12 / 4.16 , 2.08
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 50 / 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50C
Notes:
H1-H4
208
416
INTERCONNECT:
H1-H3 AND H2-H4
H2-H3
VOLTS
12
24
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
H1-H4
X1-X4
CONNECTION DIAGRAM
H4 H1
X1 X3
X2 X4
H2H3
0V
0V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 208 / 416
Secondary (Volts) 120 / 240
Input /Output Amps 0.24 , 0.12 / 0.42 , 0.21
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 50 / 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50D
Notes:
H1-H4
208
416
INTERCONNECT:
H1-H3 AND H2-H4
H2-H3
VOLTS
120
240
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
H1-H4
X1-X4
CONNECTION DIAGRAM
H4 H1
X1 X3
X2 X4
H2H3
0V
0V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 240 / 480
Secondary (Volts) 120 / 240
Input /Output Amps 0.21, 0.10 / 0.42 , 0.21
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50E
Notes:
H1-H4240
480
INTERCONNECT:
H1-H3 AND H2-H4
H2-H3
VOLTS
120
240
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
H1-H4
X1-X4
CONNECTION DIAGRAM
H4 H1
X1 X3
X2 X4
H2H3
0V
0V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 480
Secondary (Volts) 12 / 24
Input /Output Amps 0.10 / 4.17 , 2.08
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50F
Notes:
H1-H2480
VOLTS
12
24
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
X1-X4
12/24 X2-X3 X1-X3-X4
CONNECTION DIAGRAM
H2
H1
X1 X2
0V
0V
X4X3
480 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 277
Secondary (Volts) 120 / 240
Input /Output Amps 0.18 / 0.42 , 0.21
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50G
Notes:
H1-H2277
VOLTS
120
240
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
X1-X4
120/240 X2-X3 X1-X3-X4
CONNECTION DIAGRAM
H2
H1
X1 X2
0V
0V
X4X3
277 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 347 / 380
Secondary (Volts) 120 / 240
Input / Output Amps 0.14 , 0.13 / 0.42 , 0.21
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 50 / 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50H
Notes:
H1-H2347
380
VOLTS
120
240
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
H1-H3
X1-X4
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
Pos.
Volts
CONNECTION DIAGRAM
0V
H2
H3H1
X1X2X3
0V
347 380
X4
0V
H2 H3H1
Primary Tabs
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 600
Secondary (Volts) 12 / 24
Input /Output Amps 0.08 / 4.17 , 2.08
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50I
Notes:
H1-H2600
VOLTS
12
24
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
X1-X4
12/24 X2-X3 X1-X3-X4
CONNECTION DIAGRAM
H2
H1
X1 X2
0V
0V
X4X3
600 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 600
Secondary (Volts) 120 / 240
Input /Output Amps 0.08 / 0.42 , 0.21
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50J
Notes:
H1-H2600
VOLTS
120
240
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
X1-X4
120/240 X2-X3 X1-X3-X4
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
CONNECTION DIAGRAM
H2
H1
X1 X2
0V
0V
X4X3
600 V
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 240 / 480
Secondary (Volts) 12 / 24
Input /Output Amps 0.21 , 0.10 / 4.12 , 2.08
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50K
Notes:
H1-H4240
480
INTERCONNECT:
H1-H3 AND H2-H4
H2-H3
VOLTS
12
24
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
H1-H4
X1-X4
CONNECTION DIAGRAM
H4 H1
X1 X3
X2 X4
H2
H3
0V
0V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 347 / 380
Secondary (Volts) 12 / 24
Input / Output Amps 0.14 , 0.13 / 4.17 , 2.08
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 50 / 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50L
Notes:
H1-H2347
380
VOLTS
12
24
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
H1-H3
X1-X4
Pos.
Volts
CONNECTION DIAGRAM
0V
H2
H3H1
X1X2X3
0V
347 380
X4
0V
H2 H3H1
Primary Tabs
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 120
Secondary (Volts) 12
Input /Output Amps 0.42 / 4.17
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50M
Notes:
H1-H2120
CONNECT LINES TO :
VOLTS
X1-X212
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
120 V
12 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 120
Secondary (Volts) 24
Input /Output Amps 0.42 / 2.08
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50N
Notes:
H1-H2120
CONNECT LINES TO :
VOLTS
X1-X224
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
120 V
24 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 208
Secondary (Volts) 120
Input /Output Amps 0.24 / 0.42
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50O
Notes:
H1-H2208
CONNECT LINES TO :
VOLTS
X1-X2120
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
208 V
120 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 240
Secondary (Volts) 24
Input /Output Amps 0.21 / 2.08
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50P
Notes:
H1-H2240
CONNECT LINES TO :
VOLTS
X1-X224
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
240 V
24 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 240
Secondary (Volts) 120
Input /Output Amps 0.21 / 0.42
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50Q
Notes:
H1-H2240
CONNECT LINES TO :
VOLTS
X1-X2120
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
240 V
120 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 480
Secondary (Volts) 24
Input /Output Amps 0.10 / 2.08
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50R
Notes:
H1-H2480
CONNECT LINES TO :
VOLTS
X1-X224
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
480 V
24 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 480
Secondary (Volts) 120
Input /Output Amps 0.10 / 0.42
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50S
Notes:
H1-H2480
CONNECT LINES TO :
VOLTS
X1-X2120
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
480 V
120 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 600
Secondary (Volts) 12
Input /Output Amps 0.08 / 4.17
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50T
Notes:
H1-H2600
CONNECT LINES TO :
VOLTS
X1-X212
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
600 V
12 V
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 600
Secondary (Volts) 24
Input /Output Amps 0.08 / 2.08
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50U
Notes:
H1-H2600
CONNECT LINES TO :
VOLTS
X1-X224
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
600 V
24 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 600
Secondary (Volts) 120
Input /Output Amps 0.08 / 0.42
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50V
Notes:
H1-H2600
CONNECT LINES TO :
VOLTS
X1-X2120
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
600 V
120 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 600
Secondary (Volts) 240
Input /Output Amps 0.08 / 0.21
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50W
Notes:
H1-H2600
CONNECT LINES TO :
VOLTS
X1-X2240
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
600 V
240 V
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 120 / 240
Secondary (Volts) 16 / 32
Input /Output Amps 0.42 , 0.21 / 3.13 , 1.56
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 50 / 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50X
Notes:
H1-H4120
240
INTERCONNECT:
H1-H3 AND H2-H4
H2-H3
VOLTS
16
32
INTERCONNECT:
X1-X3 AND X2-X4
X2-X3
CONNECT LINES TO :
X1-X4
H1-H4
X1-X4
CONNECTION DIAGRAM
H4 H1
X1 X3
X2 X4
H2H3
0V
0V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
VA 50
Primary (Volts) 208
Secondary (Volts) 24
Input /Output Amps 0.24 / 2.08
Approvals
Temperature Rise 80°C
Insulation Class B (130°C)
Frequency 60Hz
Polarity additive
Noise level less than 40DB
DESCRIPTION
Type Open
Winding Copper
UL listed
CE compliant
CSA approved
WIRING CONNECTION
CONNECT LINES TO :
PRIMARY :
VOLTS
SECONDARY :
MODEL MTB50Y
Notes:
H1-H2208
CONNECT LINES TO :
VOLTS
X1-X224
CONNECTION DIAGRAM
H2H1
X1
0V
0V
X2
208 V
24 V
E
A
D
B
C
0.21 x 0.625
MOUNTING
INCHES / MM
WEIGHT
SHIP
HOLES
B DC E
2.25
1.05.3 x 15.9
3.753.00
67.3
2.502.25
95.3 63.557.2
DIMENSIONS
2.65
76.2
A
LBS / KG
INCHES / MM
VA
50
TECHNICAL DATA
MARCUS
SINGLE PHASE CONTROL TRANSFORMER
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]