7
REMOTE MONITORING AND CLINICIAN NOTIFICATION SYSTEM Patient SafetyNet System MASIMO Accurate, actionable patient alarms delivered directly to qualified caregivers help you keep patients safe on general care floors When You Leave the Room, You’ll Still Be There.

MASIMO Patient SafetyNet System - RESPIMEDICrespimedic.com/App_ClientFile/15bfa03b-5b29-44bf-9ff2-20a86764dd8… · noninvasively monitor SpO2 and pulse rate, as well as other clinically

Embed Size (px)

Citation preview

Page 1: MASIMO Patient SafetyNet System - RESPIMEDICrespimedic.com/App_ClientFile/15bfa03b-5b29-44bf-9ff2-20a86764dd8… · noninvasively monitor SpO2 and pulse rate, as well as other clinically

Re

mo

te

mo

nit

oR

ing

an

d C

lin

iCia

n n

ot

ifiCa

tio

n s

ys

te

m

Patient SafetyNet™ SystemMASIMO

Accurate, actionable patient alarms delivered directly to qualified caregivers help you keep patients safe on general care floors

When You Leave the Room, You’ll Still Be There.™

Page 2: MASIMO Patient SafetyNet System - RESPIMEDICrespimedic.com/App_ClientFile/15bfa03b-5b29-44bf-9ff2-20a86764dd8… · noninvasively monitor SpO2 and pulse rate, as well as other clinically

2 Stoelting RK et al. APSF Newsletter. 2009;24(2):25-32.

Patient Safety ChallengeS on general Care floorS

The last thing you expect when otherwise healthy

patients are admitted for routine procedures is that

they won’t go home due to a sentinel event.

Unfortunately, the combination of patient-controlled

analgesia and lower staff-to-patient ratios on general

care floors make it less likely that a clinician will be

there to observe an avoidable adverse event.

According to the Anesthesia Patient Safety Foundation (APSF),

post-operative patients on general care floors should be monitored

for ventilation and oxygenation, however:

> “Intermittent subjective assessments of ventilation or level of consciousness are unreliable predictors of future respiratory depression, even over short time frames,”

and...

> Continuous monitoring of oxygenation via pulse oximetry must be “the routine and not the exception.” 2

“ The literature and each of our clinical experiences have examples

of physicians on rounds, or nurses coming in to check patients

who have been dead for hours.” 1

1 Abenstein JP et al. Anesthesiology. 2010;112(2).

Page 3: MASIMO Patient SafetyNet System - RESPIMEDICrespimedic.com/App_ClientFile/15bfa03b-5b29-44bf-9ff2-20a86764dd8… · noninvasively monitor SpO2 and pulse rate, as well as other clinically

> Masimo bedside devices continuously and

noninvasively monitor SpO2 and pulse rate,

as well as other clinically valuable

measurements as needed.

> No matter what level of clinical response is needed,

Patient SafetyNet facilitates appropriate clinical

response, preempts sentinel events and

avoids unnecessary ICU transfers.

the MaSiMo PatientSafetynet SolutionThe Masimo Patient SafetyNet remote monitoring and clinician notification system

combines the gold standard performance of Masimo SET® pulse oximetry with respiration

rate monitoring and wireless clinician notification via pager. Patient SafetyNet provides

an unmatched level of patient safety on general care floors in a system that can either be

integrated into your existing IT infrastructure or operate as a stand-alone system.

Connect Patients and Caregivers Quickly, Easily, and Accurately.

> Patient SafetyNet facilitates

appropriate early clinical response,

preempts sentinel events,

and avoids unnecessary

transfers while helping you

meet Joint Commission,

APSF, and ASA guidelines

> Masimo Patient SafetyNet sends timely alarms

to qualified clinicians for review and immediate

bedside intervention, with automatic

escalation to additional clinicians

when needed.

> Dispatch rapid response teams only when needed,

since Patient SafetyNet has been shown to

decrease rapid response activations

and ICU transfers.

Page 4: MASIMO Patient SafetyNet System - RESPIMEDICrespimedic.com/App_ClientFile/15bfa03b-5b29-44bf-9ff2-20a86764dd8… · noninvasively monitor SpO2 and pulse rate, as well as other clinically

Only the unmatched accuracy and reliability of Masimo SET —

the gold standard in pulse oximetry — makes trustworthy

clinician notification on general care floors possible

MaSiMo Set PulSe oxiMetry

“ In my opinion as Quality and Safety Officer, our study results strongly

demonstrate that continuous patient surveillance with Masimo

SET and Masimo Patient SafetyNet increases healthcare value by

significantly improving clinical outcomes while reducing costs.”

> Measure-through Motion and Low

Perfusion performance of Masimo SET

has been proven to outperform all other

pulse oximetry technologies in more

than 100 independent and

objective studies.

> Masimo SET has been shown to

deliver a 97% reduction in false alarms

while detecting 95% of true alarms —

even under the most difficult clinical

conditions of motion and low perfusion,

when other pulse oximeters fail.

ReduCtion offalse alaRms

97%

Proven to help clinicians

improve outcomes

Respiration rate is a critical vital sign that

provides early detection of respiratory

compromise and patient distress

Continuous monitoring of respiration rate is especially important for post-surgical

patients receiving patient-controlled analgesia (PCA) for pain management as the

sedation can induce respiratory depression and place patients at considerable risk of

serious injury or death.1-5

MaSiMo aCouStiC reSPiration rate (rra™)

> Masimo Rainbow Acoustic Monitoring™ noninvasively and continuously

measures respiration rate using an innovative adhesive sensor with an

integrated acoustic transducer that is easily and comfortably applied to the

patient’s neck.

> End-tidal CO2 monitoring is also available on Patient SafetyNet, using either

the Oridian Capnostream 20 or the CAS 750 monitor.

An eleven month evaluation by a team of clinicians

at a large academic medical center covering 2,841

patients, showed Masimo Patient SafetyNet

provides early identification of analgesia-

induced respiratory depression and

cardiac abnormalities identified

by high and low pulse rate,

poor heart rate control, and

bradycardia. The study

showed the following

results on a single

36-bed general care

post-surgical floor1:

George T. Blike, M.D. Medical Director, Patient Safety,

Dartmouth-Hitchcock Medical Center

1 Joint Commission on Accreditation of Healthcare Organizations. Sentinel Event Alert: Patient controlled analgesia by proxy. 2004.2 Institute for Safe Medication Practices. Safety issues with patient-controlled analgesia: Part I – How errors occur. 2003.3 Institute for Safe Medication Practices. Safety issues with patient-controlled analgesia: Part II – How to prevent errors. 2003.4 Bird M. ASA Newsletter. 2007;71(8).5 Weinger MB. APSF Newsletter. 2006;21:61–67.

95%tRue alaRmdeteCtion

Unacceptably high false alarm rates

with conventional pulse oximetry

(often as high as 70%) make it

inappropriate for continuous

monitoring on general care

floors. Masimo SET is the best

pulse oximetry choice for patient

safety, clinical efficiency, and

cost effectiveness.

135iCu days saved annually

0no sentinel events

ReduCtion in iCu tRansfeRs

48%

65%ReduCtion in distRess Codes

and ResCue aCtivations

1 Taenzer AH et al. Anesthesiology. 2010;112(2):282-287.

Page 5: MASIMO Patient SafetyNet System - RESPIMEDICrespimedic.com/App_ClientFile/15bfa03b-5b29-44bf-9ff2-20a86764dd8… · noninvasively monitor SpO2 and pulse rate, as well as other clinically

RM115

%SpO2

96BPM

72RR

20SpHb g/dl

7.5

RM115

%SpO2

88BPM

67RRa

10SpHb g/dl

9.0

%SpO280

---96RR

---

4020

SpHb g/dl

SpHb Low

------7.5

PVI---205

SpOC ml/dl

18

BPM30

16067PI

------7.30

%SpMET

---80.50.6

%SpCO---

---9

BPM

72

> The configurable Masimo Patient SafetyNet central

assignment station is shown at left in patient detail

mode displaying four physiological parameters —

SpO2, pulse rate, respiration rate, and total

hemoglobin (SpHb), giving you indicators of:

> Oxygenation (Sp02) > Circulation (PR)

> Ventilation (RRa) > Bleeding (SpHb)

Configurable screen allows you to view the number of patients, clinical measurements and level of detail that are important to you

With Masimo Patient SafetyNet, you choose the system configuration

that meets your specific clinical need. You can display real-time data from

up to 40 patients at a time, and select up to four Masimo Rainbow SET

measurements based on your patient population and clinical practices.

BreaKthrough noninVaSiVe MeaSureMentS

Patient SafetyNet lets you choose the clinical measurements that

are right for you now and be confident that your investment in

patient safety won’t become obsolete tomorrow

> Masimo Rainbow SET Measure-through Motion and Low

Perfusion pulse oximetry virtually eliminates false alarms.

> Masimo Desat Index,™ PI Delta,™ and Rapid Desat™ alarms

work together to recognize and capture clinically significant

patterns of desaturation and other physiological events

that may be missed by static SpO2 and pulse rate alarms.

> Configurable alarm rules at bedside and system levels

provide maximum clinical flexibility.

> Alarm escalation rules ensure every patient is protected

by Masimo Patient SafetyNet all the time.

> Sp02

> Pulse Rate

> SpHb®

> SpOC™

> SpCO®

> SpMet®

> PVI®> RRa™

> Perfusion Index

> Masimo’s gold standard

accuracy combined with

our advanced alarm

performance lets you

effectively monitor patients

without nuisance alarms

Page 6: MASIMO Patient SafetyNet System - RESPIMEDICrespimedic.com/App_ClientFile/15bfa03b-5b29-44bf-9ff2-20a86764dd8… · noninvasively monitor SpO2 and pulse rate, as well as other clinically

A cost-effective solution that seamlessly integrates into your hospital’s IT infrastructure or operates as a stand-alone systemMasimo Patient SafetyNet remote monitoring and clinician notification system is

designed from the ground up to be an integrated IT solution, using IEEE industry

standards for connectivity to allow for more efficient sharing of data across your

hospital’s IT platforms. By leveraging existing IT infrastructure when possible,

Masimo Patient SafetyNet may provide your hospital with a lower overall cost

of ownership and improved financial benefits.

the MaSiMo Patient Safetynet SySteM

> Automatically Transmit Patient Data to a Caregiver

Who Can Intervene with Confidence

Central Clinician/Patient assignment station

server

Paging transmitterWireless access Point

> Speed appropriate clinical response

to the bedside with real-time

transmissions of clinically relevant

alarms to designated caregivers

> Early intervention avoids

adverse events

> Alarm notification directly to

qualified caregiver via low-cost,

easy-to-use pager

> IT-hosted server with configurable

alarm management logic

> Continuous streaming clinical data

transmitted over the IT network.

> Accurately monitor patients at

the bedside with Masimo pulse

oximetry and other clinically

relevant measurements

> Choose the patient monitor or set

of monitors that are right for your

specific clinical need.

Multiple patient data views provide maximum clinical flexibilityThe Patient SafetyNet Central Station can be custom

configured to provide you with patient data views that

meet your specific clinical needs.

Page 7: MASIMO Patient SafetyNet System - RESPIMEDICrespimedic.com/App_ClientFile/15bfa03b-5b29-44bf-9ff2-20a86764dd8… · noninvasively monitor SpO2 and pulse rate, as well as other clinically

© 2

010

Ma

simo

Co

rpo

ratio

n. a

ll righ

ts rese

rve

d.

Masimo InternationalNeuchâtel, Switzerlandtel [email protected]

Masimo Americas Irvine, Californiatel 1-877-4-Masimo [email protected] 76

23

-472

3F-

1010

interfaCe MaSiMo Patient Safetynet to a MaSiMo Paging SySteM,

your oWn internal Paging or other MeSSaging SySteM:

Origin of Alarm Alarm Description Date of Alarm Parameter Values

Navigate Back Navigate Forward Function Menu Read Messages, On Button

Navigate Down

Navigate Up

Alarm Level

MaSiMo Patient Safetynet BedSide radio

Dimensions . . . . . . . . . . . . . . . . . . . . . . . .6.5” x 3.3”x 1.2” (16.5 cm x 8.5 cm x 3.0 cm)Interface Ethernet (RJ-45) serial (DB-9) 802.11a/b/gSecurity. . . . . . . . . . . . WPA-TKIP, WPA2-AES (128-bit) 40/64-104,128/152-bit WEP IEEE 802.1X wireless client support and wired LAN authentication EAP-TLS, PEAP and LEAP-compatible authenticationOperating Temperature . . . . . . . . . . . . . . . . .32 - 104° F (0 - 40° C)Power Supply . . . . . . . . . . . . . . . . . . . . . . . .110 - 240 VACCompatible Masimo Devices . . . . . . . .Radical-7, Rad-8

MaSiMo Patient Safetynet SerVer

CPU . . . . . . .minimum Quad-Core Intel Xeon 2.0 GhzMemory . . . . . . . . . . . . . . . . . . . . . . . minimum 4GB RAMStorage . . . . . minimum 160 GB RAID 1 storage arrayManagement . . . . . . . . . . . . . . . remote access capableCommunications . . . . . . . . . . . . . . . redundant Gigabit 10/100/1000 BaseT Ethernet NICsAC power . . . . . . . . . . . . . . . . redundant power supplies (110 – 240 VAC, 50/60 Hz)Accessories . . . . . . . . . . . . . monitor/keyboard/mouse Temperature, Operating . . . . . 50 – 95° F (10 – 35° C)Form Factor . . . . . . . . . . . . . . . . . .2U Chassis EnclosurePhysical Dimensions . . . . . . . . . 3.44” x 17.64” x 27.50” (8.75 cm x 44.80 cm x 69.88 cm)Weight . . . . . . . . . . . . . . . . . . . . . . . . . . .51.5 lb (19.22 kg)

MaSiMo Patient Safetynet CliniCian aSSignMent Station

CPU . . . . . . . . . . . . . . . . . . . . . . . . . . . minimum 1.0 GHzMemory . . . . . . . . . . . . . . . . . . . . . . .minimum 1 GB RAMStorage . . . . . . . . . . . . . . . . . . . . . . .minimum 8 GB HDDGraphics . . . . . . . . . minimum 1280 x 1024 resolutionOperating System . . . . . . . . . . . . . . Windows XP, VistaCommunications . . . . . . . . . . . . . . minimum ethernet 10/100 BaseTAC power . . . . . . . . . . . . . . . . . 110 – 240 VAC 50/60 HzAccessories . . . . . . . . . . . . . . . . . . . . . keyboard/mouse

MaSiMo Patient Safetynet PSn VieW CliniCian aSSignMent Station

CPU . . . . . . . . . . . minimum Intel Core 2 Duo, 2.0 GHzMemory . . . . . . . . . . . . . . . . . . . . . . minimum 4 GB RAMStorage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .320 GB HDDOperating System . . . . . . . . . . . . . . . . . Windows Vista Home PremiumCommunications . . . . . . . . . . . . . . . . . . . .10/100/1000 BaseT Ethernet NICAC power . . . . . . . . . . . . . . . . 110 – 240 VAC, 50/60 Hz)Temperature, Operating . . . . 50 – 95° F (10 – 35° C)Physical Dimensions . . . . . . . . . . . . . . . 17.4” x 21” x 2.6” (44.20 cm x 53.34 cm x 6.60 cm)Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 lb (10.89 kg)

MaSiMo Patient Safetynet Paging tranSMitter PerforManCe

Transmit Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5wFrequency . . . . . . . . . . . . . . . . . . . . .UHF 440 - 470 MHzAC power . . . . . . . . . . . . . . . . . 110 - 240 VAC 50/60 HzDimensions . . . . . . . . . . . . . . . . . . . . . . . 2.8” x 8.5” x 10” (7.3 cm x 21.6 cm x 25.4 cm)Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.9 lbs (850 g) external ConneCtorS

RJ45 . . . . . . . . . . . . . . . . . . . . . standard network cableAntenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BNC MaSiMo Patient Safetynet Pager

Display Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .LCDInformation . . . . . . . . . date, origin and type of alarm, current clinical parameter, and level of alarmNotification Modes . . . . . . . . . . . . tone and/or vibrateDimensions . . . . . . . . . . . . . . . . . . . . . . 80 x 54 x 19 mmWeight (with battery) . . . . . . . . . . . . . . . . . . . 65 gramsBattery Type . . . . . . . . . . . . . . . . . . . . . . . . 1 AA alkaline Transmit distances for the Patient SafetyNet bedside radio and the Patient SafetyNet paging transmitter will vary depending upon the structural surroundings (construction, shielding, interfering devices, etc.)

PerforManCe

MaSiMo Set PerforManCe