2
6045 Cochran Road • Cleveland, OH 44139-3303 • 1-800-850-4608 / 1-440-248-9300 • Fax: 1-440-349-2307 • www.inovision.com Inovision Radiation Measurements Master Application Guide Nuclear Power Systems Master Application Guide NPS The following table is intended as a guide for selecting the appropriate equipment for your radiation monitoring applications. If your specific application is not listed, contact the Inovision Nuclear Power Systems Department for assistance: 1-800-850-4608, Ext. 3643 or 3645, 1-440-542-3643, Fax: 1-440-349-2307, or E-mail: [email protected]. APPLICATION RECOMMENDED PRODUCT A high range area monitor that fulfills the requirements of NRC Reg. Guide 1.97, and meets NRC Reg. Guide 1.89/1.100 and IEEE 323 Model 875 High Range Containment Monitor A wide range ion chamber detector that measures gamma radiation in the range of 10 -1 to 10 7 mR/h Model 945A Wide Range Ion Chamber Area Monitor A Geiger-Mueller (GM) area monitor that detects gamma radiation over a five decade span and covers an 8 decade range from 10 -2 to 10 5 mR/h Model 955A GM Area Monitor A process skid to withdraw and monitor a sample of particulate (either fixed or moving), iodines and noble gasses, or any combination of the three Model 940-1 Off-Line Gaseous Effluent Monitor A process skid to withdraw and monitor a sample of liquid effluent Model 940-2 Off-Line Liquid Effluent Monitor A non-invasive (snowplow) effluent monitor to measure the gamma activity in a liquid process stream Model 940-3 On-Line (Snowplow) Monitor A liquid effluent monitor to measure the gamma activity in a liquid stream by inserting a detector and lead shield directly into the process line Model 940-4 In-Line Liquid Effluent Monitor An extended range gaseous effluent skid to be used in conjunction with an existing or new normal range gaseous effluent skid Model 940-5 Accident Range Gaseous Effluent Monitor A portable skid designed to be easily transported to different sites to withdraw and measure gaseous effluents Model 940-9 Portable Continuous Air Monitor A stand-alone instrument capable of interfacing directly to radiation detectors, and displaying radiation levels in CPM, mR/h, or μCi/cc Model 942A, 946A, & 956A Universal Digital Ratemeters A digital radiation monitoring, data acquisition and control system that monitors particulate, iodine, and noble gas radiation levels Model 960 Series Area Monitors Process Monitors Electronics

Master Application Guide Nuclear Power Systems NPS · Master Application Guide Nuclear Power Systems ... NRC Reg. Guide 1.97, and meets NRC Reg. Guide 1.89/1.100 and IEEE 323 Model

Embed Size (px)

Citation preview

Page 1: Master Application Guide Nuclear Power Systems NPS · Master Application Guide Nuclear Power Systems ... NRC Reg. Guide 1.97, and meets NRC Reg. Guide 1.89/1.100 and IEEE 323 Model

6045 Cochran Road • Cleveland, OH 44139-3303 • 1-800-850-4608 / 1-440-248-9300 • Fax: 1-440-349-2307 • www.inovision.com

Inovision Radiation Measurements

Master Application Guide Nuclear Power Systems

Master Application Guide

NPS

The following table is intended as a guide for selecting the appropriate equipment for your radiation monitoring applications.If your specific application is not listed, contact the Inovision Nuclear Power Systems Department for assistance:1-800-850-4608, Ext. 3643 or 3645, 1-440-542-3643, Fax: 1-440-349-2307, or E-mail: [email protected].

APPLICATION RECOMMENDED PRODUCT

A high range area monitor that fulfills the requirements of NRC Reg. Guide 1.97, and meets NRC Reg. Guide 1.89/1.100 and IEEE 323

Model 875 High Range Containment Monitor

A wide range ion chamber detector that measures gamma

radiation in the range of 10-1 to 107 mR/h

Model 945A Wide Range Ion Chamber Area Monitor

A Geiger-Mueller (GM) area monitor that detects gamma radiation over a five decade span and covers an 8 decade

range from 10-2 to 105 mR/h

Model 955A GM Area Monitor

A process skid to withdraw and monitor a sample of particulate (either fixed or moving), iodines and noble gasses, or any combination of the three

Model 940-1 Off-Line Gaseous Effluent Monitor

A process skid to withdraw and monitor a sample of liquid effluent

Model 940-2 Off-Line Liquid Effluent Monitor

A non-invasive (snowplow) effluent monitor to measure the gamma activity in a liquid process stream

Model 940-3 On-Line (Snowplow) Monitor

A liquid effluent monitor to measure the gamma activity in a liquid stream by inserting a detector and lead shield directly into the process line

Model 940-4 In-Line Liquid Effluent Monitor

An extended range gaseous effluent skid to be used in conjunction with an existing or new normal range gaseous effluent skid

Model 940-5 Accident Range Gaseous Effluent Monitor

A portable skid designed to be easily transported to different sites to withdraw and measure gaseous effluents

Model 940-9 Portable Continuous Air Monitor

A stand-alone instrument capable of interfacing directly to radiation detectors, and displaying radiation levels in CPM, mR/h, or µCi/cc

Model 942A, 946A, & 956A Universal Digital Ratemeters

A digital radiation monitoring, data acquisition and control system that monitors particulate, iodine, and noble gas radiation levels

Model 960 Series

Area Monitors

Process Monitors

Electronics

Page 2: Master Application Guide Nuclear Power Systems NPS · Master Application Guide Nuclear Power Systems ... NRC Reg. Guide 1.97, and meets NRC Reg. Guide 1.89/1.100 and IEEE 323 Model

6045 Cochran Road • Cleveland, OH 44139-3303 • 1-800-850-4608 / 1-440-248-9300 • Fax: 1-440-349-2307 • www.inovision.com

Specifications are subject to change without notice.mag-ds rev 1 09 may 01

APPLICATION RECOMMENDED PRODUCT

A GM area detector that measures gamma radiation over a five decade span

Model 897A Series GM Detectors

A scintillation detector that responds to either beta or gamma radiation

Model 943 Series Beta Scintillation Detectors

Model 943-27-31 Current Mode Beta DetectorModel 943 Series Gamma Scintillation DetectorsModel 943-36CS Gamma Scintillation Detector with Integral Check Source

A wide range ion chamber that measures gamma radiation in

the range of 10-1 to 107 R/h

Model 977 Series Wide Range Ion Chamber Detectors

A field calibrator that can be used to verify calibration of GM and ion chamber detectors

Model 848-8 Series Field Test Sources

A field calibrator that can be used to verify calibration of high range detectors

Model 878-10 High Range Ion Chamber Detectors

A lead shielded three liter off-line sampler Model 841-334 Three Liter Off-Line SamplerA moving filter particulate sampler that is 97% efficient for particles 0.3 micron or larger

Model 859A-1 Moving Particulate Filter Sampler with Controller

A remote alarm/indicator with or without an analog meter, designed for use with all UDRs and Victoreen detectors

Model 944-17/18, 948A, & 958A Remote Alarm/Indicators

Calibration Equipment

Samplers

Remote Alarms/Indicators

Detectors