  • 6045 Cochran Road Cleveland, OH 44139-3303 1-800-850-4608 / 1-440-248-9300 Fax: 1-440-349-2307 www.inovision.com

    Inovision Radiation Measurements

    Master Application Guide Nuclear Power SystemsMaster Application Guide

    NPS

    The following table is intended as a guide for selecting the appropriate equipment for your radiation monitoring applications.If your specific application is not listed, contact the Inovision Nuclear Power Systems Department for assistance:1-800-850-4608, Ext. 3643 or 3645, 1-440-542-3643, Fax: 1-440-349-2307, or E-mail: systems@inovision.com.

    APPLICATION RECOMMENDED PRODUCT

    A high range area monitor that fulfills the requirements of NRC Reg. Guide 1.97, and meets NRC Reg. Guide 1.89/1.100 and IEEE 323

    Model 875 High Range Containment Monitor

    A wide range ion chamber detector that measures gamma

    radiation in the range of 10-1 to 107 mR/h

    Model 945A Wide Range Ion Chamber Area Monitor

    A Geiger-Mueller (GM) area monitor that detects gamma radiation over a five decade span and covers an 8 decade

    range from 10-2 to 105 mR/h

    Model 955A GM Area Monitor

    A process skid to withdraw and monitor a sample of particulate (either fixed or moving), iodines and noble gasses, or any combination of the three

    Model 940-1 Off-Line Gaseous Effluent Monitor

    A process skid to withdraw and monitor a sample of liquid effluent

    Model 940-2 Off-Line Liquid Effluent Monitor

    A non-invasive (snowplow) effluent monitor to measure the gamma activity in a liquid process stream

    Model 940-3 On-Line (Snowplow) Monitor

    A liquid effluent monitor to measure the gamma activity in a liquid stream by inserting a detector and lead shield directly into the process line

    Model 940-4 In-Line Liquid Effluent Monitor

    An extended range gaseous effluent skid to be used in conjunction with an existing or new normal range gaseous effluent skid

    Model 940-5 Accident Range Gaseous Effluent Monitor

    A portable skid designed to be easily transported to different sites to withdraw and measure gaseous effluents

    Model 940-9 Portable Continuous Air Monitor

    A stand-alone instrument capable of interfacing directly to radiation detectors, and displaying radiation levels in CPM, mR/h, or Ci/cc

    Model 942A, 946A, & 956A Universal Digital Ratemeters

    A digital radiation monitoring, data acquisition and control system that monitors particulate, iodine, and noble gas radiation levels

    Model 960 Series

    Area Monitors

    Process Monitors

    Electronics

  • 6045 Cochran Road Cleveland, OH 44139-3303 1-800-850-4608 / 1-440-248-9300 Fax: 1-440-349-2307 www.inovision.com

    Specifications are subject to change without notice.mag-ds rev 1 09 may 01

    APPLICATION RECOMMENDED PRODUCT

    A GM area detector that measures gamma radiation over a five decade span

    Model 897A Series GM Detectors

    A scintillation detector that responds to either beta or gamma radiation

    Model 943 Series Beta Scintillation Detectors

    Model 943-27-31 Current Mode Beta DetectorModel 943 Series Gamma Scintillation DetectorsModel 943-36CS Gamma Scintillation Detector with Integral Check Source

    A wide range ion chamber that measures gamma radiation in

    the range of 10-1 to 107 R/h

    Model 977 Series Wide Range Ion Chamber Detectors

    A field calibrator that can be used to verify calibration of GM and ion chamber detectors

    Model 848-8 Series Field Test Sources

    A field calibrator that can be used to verify calibration of high range detectors

    Model 878-10 High Range Ion Chamber Detectors

    A lead shielded three liter off-line sampler Model 841-334 Three Liter Off-Line SamplerA moving filter particulate sampler that is 97% efficient for particles 0.3 micron or larger

    Model 859A-1 Moving Particulate Filter Sampler with Controller

    A remote alarm/indicator with or without an analog meter, designed for use with all UDRs and Victoreen detectors

    Model 944-17/18, 948A, & 958A Remote Alarm/Indicators