DESCRIPTION
Three Rivers Technical Conference August 3-4, 2010 NDT Testing of built-up sections and Electronic Components Presenter: Rushie Ghimire Supervised by : Dr. Gary Anderson Team: Nikunj Parmar. Materials Evaluation and Testing Laboratory (METLab) - PowerPoint PPT Presentation
Citation preview
04/22/23 1
Materials Evaluation and Testing Laboratory (METLab)Mechanical Engineering Department, Box 2219 SCEH 214 South Dakota State University, Brookings, SD 57007-0294
Phone: (605) 688-4300, Fax: (605) 688-5878, http://www.sd-metlab.org
Three Rivers Technical Conference August 3-4, 2010
NDT Testing of built-up sections and Electronic Components
Presenter: Rushie Ghimire
Supervised by : Dr. Gary AndersonTeam: Nikunj Parmar
Project Director: Dr. Fereidoon Delfanian
NSI conference
Acoustic Emission Testing (AE) Microscopic evaluationRadiography (RT) – Uses high energy photons (X-
ray machine)
04/22/23 NSI conference 2
Different methods of NDT testing
AE is the transient elastic energy which is generated from the material due to fracture, deformation, dislocation or discontinuity in the material itself
AE technology is used to examine the defect, flaw and formation of cracks in structural materials (Health monitoring of structures).
04/22/23 NSI conference 3
Acoustic Emission (AE) Overview
Sounds made by a material, structure, or machine in use or under load are heard and analyzed to determine its "state of health”
One or more sensors are attached to the object and the sounds are analyzed using computer based instruments
Noises may arise from:– crack growth – material changes (such as
corrosion)– friction
04/22/23 NSI conference 4
AE Principle
• Peak amplitude - The maximum of AE signal. dB=20log10(Vmax/1µvolt)-preamlifier gain
• Energy – Integral of the rectified voltage signal over the duration of the AE hit.
• Duration – The time from the first threshold crossing to the end of the last threshold crossing.
• Counts – The number of AE signal exceeds threshold.• Rise time - The time from the first threshold crossing to the maximum
amplitude. • Count rate - Number of counts per time unit.
04/22/23 NSI conference 5
AE HIT and Parameters
• During Production: welding, heat treatment, tempering, firing of ceramics.
• Quality Control: Testing of pressure vessels and pipes, proof testing of components.
• In-service Inspection: Pressure vessels and pipes, bridges, buildings, machines, ropes,dams.
04/22/23 6
AE Applications
NSI conference
Built up section04/22/23 7NSI conference
• Develop an AE method to properly quantifying AE signals that are measured on the outer steel liner or outer composite liner that are generated by the inner steel liner.
04/22/23 NSI conference 8
Objective of the test
steel and composite samples04/22/23 9NSI conference
Steel specimensDimensions: 7 inches long, 1 inch wide, and 0.125 inch thick.
Carbon composite specimensDimensions: 7 inches long, 1 inch wide, and 0.06 inch thick.
Cont..04/22/23 10NSI conference
Dimensions of steel: 9 inches long, 1 inch wide, and 0.125 inch thick.Dimensions of composite: 7 inches long, 1 inch wide, and 0.06 inch thick.
Cont..04/22/23 11NSI conference
Dimensions of inner layer steel: 9 inches long, 1 inch wide, and 0.125 inch thick.Dimensions of outer layer steel: 7 inches long, 1 inch wide, and 0.125 inch thick.Dimensions of composite: 7 inches long, 1 inch wide, and 0.06 inch thick.
AE Tensile test 04/22/23 12NSI conference
Monitor the damage during the tensile test of the steel and composite specimens at different loadings.
After each load, a picture was taken of the microscopic image of the specimen and evaluated for structural damage.
The universal test machine was used to load the specimens.
Steel specimen:• Loaded to 25 kN • 28.68 kN (failure)
AE Tensile test result of steel
04/22/23 13NSI conference
0 20000 40000 60000 80000 100000 120000 140000
0
25
50
75
100
125
150
175
200
225
250
275
300Steel-04 Samples
Stre
ss (M
Pa)
Strain (µ)
Stress4
0 200 400 600 800 1000 1200 1400 1600
0
25
50
75
100
125
150
175
200
225
250
275
300 Steel-04 Samples
Stre
ss (M
Pa)
Cumulative Count
Stress4
• Yield stress is 175 MPa and Failure stress is 284 MPa• Yield stress from the plots of cumulative count is 168 MPa and
failure stress is 280 MPa• Increase in cumulative count after yield shows the formation and
growth of defects leading to failure.
Cont..
04/22/23 14NSI conference
The displacement plot on the right shows non-linearity around 210 seconds. Around 210 sec a large number of emissions are recorded with both higher and lower amplitude at the time of maximum load.
04/22/23 NSI conference 1504/22/23
The amplitude tends to start out small and increases in amplitude as the crack size increases.During crack growth there is a non-periodic cycling of event amplitude from 45-100 dB, suggesting the intermittent weakening at the crack front.
Microscopic Image before and after failure
04/22/23 16NSI conference
Images and plots at failure loading04/22/23 17NSI conference
Steel Failure04/22/23 18
Specimen failure plane was at approximately at 45 degree angle from the horizontal.
NSI conference
Steel afilure04/22/23 19NSI conference
The failure plane was at approximately at 15 degree angle from the horizontal.
AE test on carbon composite04/22/23 20
•Load to 30.45kN•Load to 49.42kN (failure)
Specimen failed right across the grip which may be due the teeth of the grip penetrating the outer layer of the composite.
NSI conference
Composite failure results
04/22/23 21
Higher amplitude, number of counts, and duration are observed near failure.Higher amplitude is the sign of the fiber breakage and matrix cracking.
NSI conference
Outer layer crack
04/22/23 22
Fibers in composite specimen run bidirectional in the outer layer and unidirectional in the inner layers.
NSI conference
Fiber Breakage and Pullout from Matrix
04/22/23 23NSI conference
Matrix Debonding
04/22/23 24NSI conference
AE results of E-glass 04/22/23 25
0 3000 6000 9000 12000 15000 18000 21000 24000
0
15
30
45
60
75
90
105
120
135E-Glass Composite
Stre
ss (M
Pa)
Axial Strain (µ)
Stress
• Stress-strain plots of E-Glass showing maximum stresses at 117 Mpa
• The stress vs. cumulative count plot has a linear relationship from zero to yield stress, from where the plot begins to diverge from a straight line.
• Yield stress of E-Glass sample on cumulative count plot is at 90Mpa.
• Cumulative counts for E-glass increases rapidly after yield stress with little increase in stress
• Brittle failure
NSI conference
0 10000 20000 30000 40000 50000
15
30
45
60
75
90
105
120
135 EG Sample
Stre
ss (M
Pa)
Cumulative Count
Stress
AE results of Fiber glass04/22/23 26
0 1x104 2x104 3x104 4x104 5x104 6x104
15
30
45
60
75
90
105
120 FG Sample
Stre
ss (M
Pa)
Cumulative Count
Stress
Maximum stress of fiber glass sample: 125 MPa yield stress of Fiber glass sample is 55 Mpa on cumulative count plot. Cumulative counts for Fiber glass also increases rapidly after yield stress with little
increase in stress.
NSI conference
0 4000 8000 12000 16000 20000
0
20
40
60
80
100
120
140 Fiber Glass Composite
Stre
ss (M
Pa)
Axial Strain (µ)
Stress
Use of X-ray in AE testing
• Microscopic picture can only show defects on the outer layer.
• The inner surface micro-crack can be seen using X-ray images.
• Several papers have discussed the use of CT-scan or x-ray to see the inner surface cracks and relate then to the AE hit pattern
• The use of CT-can or X-ray has been done rarely.
04/22/23 27NSI conference
X-ray of the steel specimens 04/22/23 28NSI conferenceNSI conference
AE can be problematic due to: Effect of mounting condition
• couplant (silicone gel or petroleum jelly)• mounting pressure• Thickness of the hot glue
Noise from the loading machine Degradation of the sensitivity of the system
• wiring faults• deterioration of electronics
04/22/23 29NSI conference
Industrial task04/22/23 30NSI conference
Conclusion
• AE technique is an excellent tool to determine when a micro cracks initiated in the specimens.
• The continuous high AE amplitude represents the failure of the material or that the material is at risk.
• AE can find yield in steel and composite.• AE can find failure of steel and composite
04/22/23 31NSI conference
Questions?
04/22/23 NSI conference 32
Thank you!