2 Merlin Gerin Merlin Gerin 3 0.5 to 125A: Multi 9 circuit breakers symetrical rail mounting C60 O - OFF MERLIN GERIN NC100H C100A 415Va 27265 10kA IEC 947.2 O - OFF 1 3 2 4 multi 9 MERLIN GERIN multi 9 C60N C63 400Va 6000 24208 O - OFF O - OFF 10kA IEC 947.2 1 3 2 4 MERLIN GERIN multi 9 DPN vigi C40 In 0,300A 230Va 20912 BS EN 61009 O - OFF test mensuel test monthly N 2 N 1 a 4500 6 kA IEC 947.2 DPN Vigi NC100 6 to 32A 1 to 40A 6 to 40A 10 to 40A 0.5 to 63A 10 to 100A 125A DPNa DPN N DPN N Vigi V40H C60a C60N C60H C60L NC100H NC100L NC100LS NC100LH NC125H number of poles 1 + N 1 + N 1 + N 1 + N 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1-2-3-4 1-2-3-4 1-2-3-4 1-2-3-4 3-4 electrical characteristics rated current (A) In 30°C 32 40 40 40 40 63 63 40°C 25 32.40 50.63 100 63 63 63 125 rated insulation voltage (V) Ui 440 440 440 440 440 440 440 440 440 440 440 440 440 440 415 impulse withstand voltage (kV) Uimp 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 rated operational voltage (V) Ue AC 50.60Hz 230 230 230 240 440 440 440 440 440 440 440 440 440 440 415 fast closing disconnection with positive contact indication AC breaking capacity (kA rms) IEC 947.2 (EN 60.947.2) Icu 130V 10 20 30 50 50 50 240V 10 5 10 10 20 15 30 25 50 20 40 15 30 20 50 70 80 20 400V 10 25 36 50 415V 3 5 3 10 4 15 6 25 5 20 4 15 10 25 36 40 10 440V 3 6 10 20 15 10 6 20 30 30 Ics (% of Icu) 100% 100% 100% 75% 75% 50% 50% 50% 50% 75% 75% 75% 75% 75% IEC 898 Icn 230V 4.5 6 6 Ics 4.5 6 6 DC breaking capacity (kA) IEC 947.2 (EN 60.947.2) Icu 60V 15 15 10 15 20 25 25 25 20 (1p) 125V 10 (2p) 20 (2p) 25 (2p) 30 (2p) 30 (2p) 30 (2p) 30 (2p) 125V 20 (3p) 30 (3p) 40 (3p) 50 (3p) 50 (3p) 50 (3p) 40 (3p) 250V 25 (4p) 40 (4p) 50 (4p) 60 (4p) 60 (4p) 60 (4p) 20 (4p) 25 (1p) 36 (1p) 50 (1p) Ics (% of Icu) 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% trip units (non adjustable) curve type B (lm = 3.2 to 4.8ln) C (lm = 7 to 10ln) D (lm = 10 to 14ln) K (lm = 10 to 14In) Z (lm = 2.4 to 3.2) MA (lm = 12ln) 40A 63A personnel protection add-on rcd's (Vigi module) integrated integrated 30-300mA 30mA electrical auxiliaries auxiliary and alarm switches (OF-SD) shunt trip (MX) ; undervoltage release (MN) installation plug in base 63A terminal shieds padlocking device rotary handle dimensions (mm) W 18 18 36 36 18/P 27/P H 78 78 78 81 81 81 D 70 70 70 70 70 70

MCB-MCCB

  • Upload
    con-gio

  • View
    75

  • Download
    4

Embed Size (px)

Citation preview

  • 2 Merlin Gerin Merlin Gerin 3

    0.5 to 125A: Multi 9 circuit breakerssymetrical rail mounting

    C60

    O - OFF

    MERLIN GERIN

    NC100HC100A415Va

    27265

    10kA IEC 947.2

    O - OFF

    1 3

    2 4

    multi 9

    MERLIN GERIN

    multi 9C60NC63400Va6000

    24208

    O - OFFO - OFF

    10kA IEC 947.2

    1 3

    2 4

    MERLIN GERIN

    multi 9DPN vigiC40 In 0,300A230Va

    20912

    BS EN 61009

    O - OFF

    test mensueltest monthly

    N 2

    N 1

    a4500

    6 kA IEC 947.2

    DPN Vigi

    NC100

    6 to 32A 1 to 40A 6 to 40A 10 to 40A 0.5 to 63A 10 to 100A 125ADPNa DPN N DPN N Vigi V40H C60a C60N C60H C60L NC100H NC100L NC100LS NC100LH NC125H

    number of poles 1 + N 1 + N 1 + N 1 + N 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1-2-3-4 1-2-3-4 1-2-3-4 1-2-3-4 3-4electrical characteristicsrated current (A) In 30C 32 40 40 40 40 63 63

    40C 25 32.40 50.63 100 63 63 63 125rated insulation voltage (V) Ui 440 440 440 440 440 440 440 440 440 440 440 440 440 440 415impulse withstand voltage (kV) Uimp 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6rated operational voltage (V) Ue AC 50.60Hz 230 230 230 240 440 440 440 440 440 440 440 440 440 440 415fast closing n n n n n n n n n n n n ndisconnection with positive contact indication n n n n n n n n n n nAC breaking capacity (kA rms)IEC 947.2 (EN 60.947.2) Icu 130V 10 20 30 50 50 50

    240V 10 5 10 10 20 15 30 25 50 20 40 15 30 20 50 70 80 20400V 10 25 36 50415V 3 5 3 10 4 15 6 25 5 20 4 15 10 25 36 40 10440V 3 6 10 20 15 10 6 20 30 30

    Ics (% of Icu) 100% 100% 100% 75% 75% 50% 50% 50% 50% 75% 75% 75% 75% 75%IEC 898 Icn 230V 4.5 6 6

    Ics 4.5 6 6DC breaking capacity (kA)IEC 947.2 (EN 60.947.2) Icu 60V 15 15 10 15 20 25 25 25 20 (1p)

    125V 10 (2p) 20 (2p) 25 (2p) 30 (2p) 30 (2p) 30 (2p) 30 (2p)125V 20 (3p) 30 (3p) 40 (3p) 50 (3p) 50 (3p) 50 (3p) 40 (3p)250V 25 (4p) 40 (4p) 50 (4p) 60 (4p) 60 (4p) 60 (4p) 20 (4p) 25 (1p) 36 (1p) 50 (1p)

    Ics (% of Icu) 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%trip units (non adjustable)curve type B (lm = 3.2 to 4.8ln) n n n n n n n n n n n

    C (lm = 7 to 10ln) n n n n n n n n n n n n n n nD (lm = 10 to 14ln) n n n nK (lm = 10 to 14In) n nZ (lm = 2.4 to 3.2) n nMA (lm = 12ln) n 40A n 63A

    personnel protectionadd-on rcd's (Vigi module) integrated integrated n n n n n n n n n

    30-300mA 30mAelectrical auxiliariesauxiliary and alarm switches (OF-SD) n n n n n n n n n n nshunt trip (MX) ; undervoltage release (MN) n n n n n n n n n n ninstallationplug in base n n 63Aterminal shieds n npadlocking device n n n n n n nrotary handle n n ndimensions (mm) W 18 18 36 36 18/P 27/P

    H 78 78 78 81 81 81D 70 70 70 70 70 70

  • 4 Merlin Gerin Merlin Gerin 5

    15 to 600A: Compactdisconnector mouled case circuit breakerslow breaking capacity range: E

    ImIr

    DE 225225A/48C90105%Ir

    alarm

    ImIr

    OFF

    MERLIN GERINcompactNS225 EUi 550V. Uimp 6kV.

    220/240380/415440500660/690250

    853635308

    50

    cat A

    IEC947-2UTE VDE BS CEI UNE NEM

    A

    Ue(V)

    Icu(kA)

    Ics=50% Icu

    225Apushtotrip

    pushto

    trip

    225E

    P93083

    Compact NS225E

    15 to 100A 125 to 225A 250 to 400A 500 to 600AC100E NS225E NS400E NS600E

    number of poles 3 3 3 3electrical characteristicsrated current (A) In 40C 100 225 400 600rated insulation voltage (V) Ui 500 500 500 500rated impulse withstand voltage (kV) Uimp 6 6 6 6rated operational voltage (V) Ue AC 50/60Hz 500 500 500 500

    DCcharacteristics according to IEC 947.2rated ultimate breaking capacity Icu AC 50/60Hz 220/240V 30 30 30 30(kA rms) 380V 18 18 25 25

    415V 10 15 25 25440V 8 15 18 18500V 7.5 15 15660/690V

    rated service breaking performance Ics (% of Icu) 50% 50% 50% 50%utilisation category A A A Apollution degree III III III IIIfront face insulation class II n n n nrated admissible short time Icw (kA rms)withstand current duration (s)performances according NEMArated breaking capacity AB1 (O-CO) (kA) 240V 30 30 30 30

    480V 8 15 18 18600V

    trip unitsthermal magnetic n n n nsolid state

    protectionfor distribution standard networks n n n n

    generator fed networkslong distance networksdirect current networks

    for motor startersfor people ELCB's Vigicompact

    Vigirex residual current relays n n n nindications and measurementauxiliary and alarm switches (OF-SD-SDE) n n n nlocal and/or distance control and monitoring (Dialpact) n n n ndata transmission (Dialpact) n n n nvoltage presence indicatorcurrent transformer moduleammeter moduleinsulation monitoring modulecontrol accessoriesshunt trip (MX) ; undervoltage release (MN) n n n ndirect or extended rotary handlesmotor mechanism for remote control

    installationversion fixed n n n n

    plug-in on a basedraw-out on chassis

    accessories terminal shields n n n npadlocking and locking device n n n n

    dimensions of 2-3 pole fixed version (mm) W 105 105 140 140H 128 161 255 255D 95 86 110 110

    weight (kg) 3 pole fixed version 1.3 1.8 6 6modelsvisible break circuit breaker Visucompactswitch - disconnectorautomatic / manual source changeover

  • 6 Merlin Gerin Merlin Gerin 7

    16 to 3200A: Compactdisconnector mouled case circuit breakersstandard range: N

    0

    push to trip

    OFF compactMERLIN GERIN

    CM2500HE

    3-pole

    600V 50/60Hz

    2500A max.

    IEC-VDE-BS

    molded caseswitch

    ON

    OFF

    TRIP

    ST 306ST

    test

    longtime

    shorttime

    groundfault

    trip indicator (push to reset)

    tr

    84 81

    1.52

    34 5

    6

    8

    10xIr

    Im

    .63.7

    .8.85 .9

    .95

    .98

    1xIn

    IrSTR 22 SE90

    105%Ir

    alarm

    ImIr

    I n = 2 5 0 A

    OFF

    MERLIN GERINcompactNS250 NUi 750V. Uimp 8kV.

    220/240380/415440500660/690250

    853635308

    50

    cat A

    IEC947-2UTE VDE BS CEI UNE NEM

    A

    Ue(V)

    Icu(kA)

    Ics=100% Icu

    160/250Apushtotrip

    pushto

    trip

    250N

    P93083

    PUSH TO TRIP

    MERLIN GERINcompact

    C 1001 HUi 750V. Uimp 8kV.Ue(V)220/240380/415440500/525660/690

    10070654035

    IEC 947-2UTE VDE BS CEIUNE NEMA

    Icu(kA)

    cat B

    Ics = 100% IcuIcw 8kA / 0,25s.

    OFF

    60 70 80 90 105 %Ir

    STR 55UE

    TFR

    Io

    xIn

    T tr tmth

    Ir ImIhI

    test

    fault

    t

    i

    connected

    disconnected

    16 to 100A 16 to 160A 16 to 250A 160 to 400A 250 to 630A 320 to 800A 400 to 1000A 500 to 1250A 625 to 1250A 800 to 1600A 1000 to 2000A 1250 to 2500A 1600 to 3200ANS100N NS160N NS250N NS400N NS630N C801N C1001N C1251N CM1250N CM1600N CM2000N CM2500N CM3200N

    number of poles 2 - 3 - 4 2 - 3 - 4 2 - 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3electrical characteristicsrated current (A) In 40C 100 160 250 400 630 800 1000 1250 1250 1600 2000 2500 3200rated insulation voltage (V) Ui 750 750 750 750 750 750 750 750 750 750 750 750 750rated impulse withstand voltage (kV) Uimp 8 8 8 8 8 8 8 8 8 8 8 8 8rated operational voltage (V) Ue AC 50/60Hz 690 690 690 690 690 690 690 690 690 690 690 690 690characteristics according to IEC 947.2rated ultimate breaking capacity Icu AC 50/60Hz 220/240V 85 85 85 85 85 85 85 85 85 85 85 85 85(kA rms) 380/415V 25 36 36 45 45 50 50 50 70 70 70 70 70

    440V 25 35 35 42 42 42 42 42 65 65 65 65 65500V 18 30 30 30 30 40 40 40 50 50 50 50 50

    for DC consult general catalogue 660/690V 8 8 8 10 10 25 25 25 50 50 50 50 50rated service breaking performance Ics (% of Icu) 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50% 50% 50%utilisation category A A A A A B B B B B B B Bpollution degree III III III III III III III III III III III III IIIfront face insulation class II n n n n n n n n n n n n nrated admissible short time Icw (kA rms) 12 15 15 32 32 32 32 32withstand current duration (s) 1 1 1 1 1 1 1 1performances according NEMArated breaking capacity AB1 (O-CO) (kA) 240V 85 85 85 85 85 85 85 85 85 85 85 85 85

    480V 25 35 35 42 42 42 42 42 65 65 65 65 65600V 10 20 20 20 20 30 30 30 50 50 50 50 50

    trip unitsthermal magnetic n n nsolid state n n n n n n n n n n n n n

    protectionfor distribution standard networks n n n n n n n n n n n n n

    generator fed networks n n n n n n n n n n n n nlong distance networks n n n n n n n n n n n n ndirect current networks n n n n n n

    for motor starters n n n n n n n nfor people ELCB's Vigicompact n n n n n

    Vigirex residual current relays n n n n n n n n n n n n nindications and measurementauxiliary and alarm switches (OF-SD-SDE) n n n n n n n n n n n n nlocal and/or distance control and monitoring (Dialpact) n n n n n n n n n n n n ndata transmission (Dialpact) n n n n n n n nvoltage presence indicator n n n n ncurrent transformer module n n n n nammeter module n n n n ninsulation monitoring module n n n n ncontrol accessoriesshunt trip (MX) ; undervoltage release (MN) n n n n n n n n n n n n ndirect or extended rotary handles n n n n n n n nmotor mechanism for remote control n n n n n n n n n n n n n

    installationversion fixed n n n n n n n n n n n n n

    plug-in on a base n n n n ndraw-out on chassis n n n n n n n n

    accessories terminal shields n n n n n n n npadlocking and locking device n n n n n n n n n n n n n

    dimensions of 2-3 pole fixed version (mm) W 105 105 105 140 140 210 210 210 418 418 418 418 418H 161 161 161 255 255 374 374 374 430 430 430 430 550D 86 86 86 110 110 172 172 172 337 337 337 337 337

    weight (kg) 3 pole fixed version 1.6 1.6 1.9 6.0 6.0 13 13 13 41 41 46 63 83modelsvisible break circuit breaker Visucompact n n n n n n n n n n n nswitch - disconnector n n n n n n n n n n nautomatic / manual source changeover n n n n n n n n

    Compact NS250N

    Compact C801N with universal chassis

    Compact CM1250N

  • 8 Merlin Gerin Merlin Gerin 9

    1.5 to 3200A: Compactdisconnector mouled case circuit breakershigh breaking capacity range: H

    1.52

    34 5

    6

    8

    10xIr

    Im

    .63.7

    .8.85 .9

    .95

    .98

    1xIn

    IrSTR 22 SE90

    105%Ir

    alarm

    ImIr

    I n = 2 5 0 A

    OFF

    MERLIN GERINcompactNS250 NUi 750V. Uimp 8kV.

    220/240380/415440500660/690250

    853635308

    50

    cat A

    IEC947-2UTE VDE BS CEI UNE NEM

    A

    Ue(V)

    Icu(kA)

    Ics=100% Icu

    160/250Apushtotrip

    pushto

    trip

    250N

    P93083

    1.5 to 80A 16 to 100A 16 to 160A 16 to 250A 160 to 400A 250 to 630A 320 to 800A 400 to 1000A 500 to 1250A 625 to 1250A 800 to 1600A 1000 to 2000A 1250 to 2500A 1600 to 3200ANS80HMA NS100H NS160H NS250H NS400H NS630H C801H C1001H C1251H CM1250H CM1600H CM2000H CM2500H CM3200H

    number of poles 3 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3electrical characteristicsrated current (A) In 40C 80 100 160 250 400 630 800 1000 1250 1250 1600 2000 2500 3200rated insulation voltage (V) Ui 750 750 750 750 750 750 750 750 750 750 750 750 750 750rated impulse withstand voltage (kV)Uimp 8 8 8 8 8 8 8 8 8 8 8 8 8 8rated operational voltage (V) Ue AC 50/60Hz 690 690 690 690 690 690 690 690 690 690 690 690 690 690characteristics according to IEC 947.2rated ultimate breaking Icu AC 50/60Hz 220/240V 100 100 100 100 100 100 100 100 100 125 125 125 125 125capacity (kA rms) 380/415V 70 70 70 70 70 70 70 70 70 85 85 85 85 85

    440V 65 65 65 65 65 65 65 65 65 85 85 85 85 85500V 25 50 50 50 50 50 50 50 50 50 50 50 50 50

    for DC consult general catalogue 660/690V 6 10 10 10 20 20 40 40 40 50 50 50 50 50rated service breaking perform. Ics (% of Icu) 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50% 50% 50%utilisation category A A A A A A B B B B B B B Bpollution degree III III III III III III III III III III III III III IIIfront face insulation class II n n n n n n n n n n n n n nrated admissible short time Icw (kA rms) 12 15 15 32 32 32 32 32withstand current duration (s) 1 1 1 1 1 1 1 1performances according NEMArated breaking capacity AB1 (O-CO) (kA) 240V 100 100 100 100 100 100 100 100 100 125 125 125 125 125

    480V 65 65 65 65 65 65 65 65 65 85 85 85 85 85600V 10 35 35 35 35 35 42 42 42 50 50 50 50 50

    trip unitsthermal magnetic n n nsolid state n n n n n n n n n n n n n n

    protectionfor distribution standard networks n n n n n n n n n n n n n

    generator fed networks n n n n n n n n n n n n nlong distance networks n n n n n n n n n n n n ndirect current networks n n n n n

    for motor starters n n n n n n n n nfor people ELCB's Vigicompact n n n n n

    Vigirex residual current relays n n n n n n n n n n n n n nindications and measurementauxiliary and alarm switches (OF-SD-SDE) n n n n n n n n n n n n n nlocal and/or distance control and monitoring (Dialpact) n n n n n n n n n n n n ndata transmission (Dialpact) n n n n n n n n nvoltage presence indicator n n n n ncurrent transformer module n n n n nammeter module n n n n ninsulation monitoring module n n n n ncontrol accessoriesshunt trip (MX) ; undervoltage release (MN) n n n n n n n n n n n n n ndirect or extended rotary handles n n n n n n n n nmotor mechanism for remote control n n n n n n n n n n n n n

    installationversion fixed n n n n n n n n n n n n n n

    plug-in on a base n n n n ndraw-out on chassis n n n n n n n n

    accessories terminal shields n n n n n n n n npadlocking and locking device n n n n n n n n n n n n n n

    dimensions of 2-3 pole fixed version (mm) W 90 105 105 105 140 140 210 210 210 418 418 418 418 418H 120 161 161 161 255 255 374 374 374 430 430 430 430 550D 80 86 86 86 110 110 172 172 172 337 337 337 337 337

    weight (kg) 3 pole fixed version 1.0 1.6 1.6 1.9 6.0 6.0 13 13 13 41 41 46 63 83modelsvisible break circuit breaker Visucompactswitch - disconnectorautomatic / manual source changeover n n n n n n n n

    Compact NS250H

    60 70 80 90 105 %Ir

    STR 55UE

    TFR

    Io

    xIn

    T tr tmth

    Ir ImIhI

    testfault

    t

    i

    I

    0

    MERLIN GERINcompact

    C 1001 HUi 750V. Uimp 8kV.Ue(V)220/240380/415440500/525660/690

    10070654035

    IEC 947-2UTE VDE BS CEIUNE NEMA

    Icu(kA)

    cat B

    Ics = 100% IcuIcw 8kA / 0,25s.

    Compact C801H with motor mechanism

    0

    push to trip

    OFF compactMERLIN GERIN

    CM2500HE

    3-pole

    600V 50/60Hz

    2500A max.

    IEC-VDE-BS

    molded caseswitch

    ON

    OFF

    TRIP

    ST 306ST

    test

    longtime

    shorttime

    groundfault

    trip indicator (push to reset)

    tr

    84 81

    Compact CM1250H

  • 10 Merlin Gerin Merlin Gerin 11

    16 to 1000A: Compactdisconnector mouled case circuit breakerscurrent limiting range: L

    1.52

    34 5

    6

    8

    10xIr

    Im

    .63.7

    .8.85 .9

    .95

    .98

    1xIn

    IrSTR 22 SE90

    105%Ir

    alarm

    ImIr

    I n = 2 5 0 A

    OFF

    MERLIN GERINcompactNS250 NUi 750V. Uimp 8kV.

    220/240380/415440500660/690250

    853635308

    50

    cat A

    IEC947-2UTE VDE BS CEI UNE NEM

    A

    Ue(V)

    Icu(kA)

    Ics=100% Icu

    160/250Apushtotrip

    pushto

    trip

    250N

    P93083

    16 to 100A 16 to 160A 16 to 250A 160 to 400A 250 to 630A 320 to 800A 400 to 1000ANS100L NS160L NS250L NS400L NS630L C801L C1001L

    number of poles 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4 3 - 4electrical characteristicsrated current (A) In 40C 100 160 250 400 630 800 1000rated insulation voltage (V) Ui 750 750 750 750 750 750 750rated impulse withstand voltage (kV) Uimp 8 8 8 8 8 8 8rated operational voltage (V) Ue AC 50/60Hz 690 690 690 690 690 690 690characteristics according to IEC 947.2rated ultimate breaking capacity Icu AC 50/60Hz 220/240V 150 150 150 150 150 150 150(kA rms) 380/415V 150 150 150 150 150 150 150

    440V 130 130 130 130 130 100 100500V 100 100 70 100 50 100 100

    for DC consult general catalogue 660/690V 75 75 20 75 35 60 60rated service breaking performance Ics (% of Icu) 100% 100% 100% 100% 100% 50% 50%utilisation category A A A A A A Apollution degree III III III III III III IIIfront face insulation class II n n n n n n nrated admissible short time Icw (kA rms) 6.4 8withstand current duration (s) 1 1performances according NEMArated breaking capacity AB1 (O-CO) (kA) 240V 200 200 200 200 200 150 150

    480V 130 130 130 130 130 100 100600V 50 50 50 50 50 65 65

    trip unitsthermal magnetic n n nsolid state n n n n n n n

    protectionfor distribution standard networks n n n n n n n

    generator fed networks n n n n n n nlong distance networks n n n n n n ndirect current networks n n n n n n n

    for motor starters n n n n n n nfor people ELCB's Vigicompact n n n n n

    Vigirex residual current relays n n n n n n nindications and measurementauxiliary and alarm switches (OF-SD-SDE) n n n n n n nlocal and/or distance control and monitoring (Dialpact) n n n n n n ndata transmission (Dialpact) n n n n n n nvoltage presence indicator n n n n ncurrent transformer module n n n n nammeter module n n n n ninsulation monitoring module n n n n ncontrol accessoriesshunt trip (MX) ; undervoltage release (MN) n n n n n n ndirect or extended rotary handles n n n n n n nmotor mechanism for remote control n n n n n n n

    installationversion fixed n n n n n n n

    plug-in on a base n n n n ndraw-out on chassis n n n n n n n

    accessories terminal shields n n n n n n npadlocking and locking device n n n n n n n

    dimensions of 2-3 pole fixed version (mm) W 105 105 105 140 140 210 210H 161 161 161 255 255 374 374D 86 86 86 110 110 262 262

    weight (kg) 3 pole fixed version 1.6 1.6 1.9 6.0 6.0 25 25modelsvisible break circuit breaker Visucompactswitch - disconnectorautomatic / manual source changeover n n n n n n n

    Compact NS250L

    STR 53 UE

    test

    MERLIN GERINcompact

    NS400 LUi 750V. Uimp 8kV.Ue(V)220/240380/415440500/525660/690

    10070654035

    IEC 947-2UTE VDE BS CEIUNE NEMA

    Icu(kA)

    cat B

    Ics = 100% IcuIcw 6kA / 0,25s

    In = 400A

    pushto

    trip

    pushto

    trip 400

    tr

    tm

    ImIr I

    %Ir >Ir >Im >Ih

    Io

    x In.5

    .6.7

    .8 .9 1

    1

    Ir

    x Io.8

    .85

    .88.9 .93

    .95

    1.98

    Im

    x Ir1.523

    4 56

    10

    8

    Il

    x In1.523

    4 68

    11

    10

    Ih

    x In.2.3.4

    .5 .6.7

    10

    .8

    tr

    (s) @ 6 Ir1

    24

    8 16

    16

    th(s)

    I2t1

    23

    4 43

    1

    2

    on off

    tm(s)

    I2t0

    12

    3 32

    0

    1

    on off

    A

    Compact NS400L

    PUSH TO TRIP

    MERLIN GERINcompact

    C 1001 HUi 750V. Uimp 8kV.Ue(V)220/240380/415440500/525660/690

    10070654035

    IEC 947-2UTE VDE BS CEIUNE NEMA

    Icu(kA)

    cat B

    Ics = 100% IcuIcw 8kA / 0,25s.

    OFF

    60 70 80 90 105 %Ir

    STR 55UE

    TFR

    Io

    xIn

    T tr tmth

    Ir ImIhI

    test

    fault

    t

    i

    Compact C801L

  • 12 Merlin Gerin Merlin Gerin 13

    800 to 6300A: Masterpactdisconnector air circuit breaker

    M08 M20 M32 M50M10 M25 M40 M63M12M16

    number of poles 3 - 4 3 - 4 3 - 4 3 - 4electrical characteristicsrated current (A) In 40C 800-1000-1250-1600 2000-2500 3200-4000 5000-63004th pole rating (A) 800-1000-1250-1600 2000-2500 3200-4000 2500-3200rated insulation voltage (V) Ui 1000rated impulse withstand voltage (kV) Uimp 8breaking time (ms) total maxi. 25 to 30 (with no intentional delay)closing time (ms)

  • 14 Merlin Gerin Merlin Gerin 15

    .4.2.1

    MERLIN GERINinterpactINS80Ui 500VUimp 6kVIth 80A@ 60C

    Ue(V) Ie(A)

    AC23A

    IEC 947.3UTE VDE BS CEI UNE

    500 80AC22A

    AC23ADC23A

    806363

    440500250

    OFFO

    ONI

    Interpact INS80

    Interpact IN switch-disconnectors IN250 IN400 IN630 IN1000 IN1600 IN2500number of poles 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4electrical characteristics as per IEC 947-3conventional thermal current (A) Ith 60C 250 400 630 1000 1600 2500rated insulation voltage (V) Ui AC 50/60Hz 690 690 690 690 690 690rated impulse withstand voltage (kV) Uimp 8 8 8 8 8 8rated operational voltage (V) Ue AC 50/60Hz 690 690 690 690 690 690

    DC 250 250 250 250 250 250rated operational current (A) Ie AC 50/60Hz AC 22 A AC 23 A AC 22 A AC 23 A AC 22 A AC 23 A AC 21 A AC 22 A AC 21 A AC 22 A AC 21 A AC 22 A

    220/240V 250 250 400 400 630 630 1000 1000 1600 1600 2500 2500380/415V 250 250 400 400 630 500 1000 1000 (2) 1600 1600 (2) 2500 2500440/480 (1) -500V 250 250 400 400 630 500 1000 800 1600 1200 2500660/690V 250 125 400 250 500 320 1000 1600 2500

    DC DC 22 A DC 23 A DC 22 A DC 23 A DC 22 A DC 23 A DC 22 A DC 23 A DC 22 A DC 23 A DC 21 A DC 22 A250V (1P) 250 250 400 400 630 630 1000 1000 1600 1600 1600

    making capacity Icm (kA peak) switch-disconnector alone 30 40 50 75 75 105with upstream protection 330 330 330 176 105 105

    short-time withstand current Icw (kA rms) 1s 8500 12000 25000 35000 35000 500003s 4900 6900 14400 20000 20000 2850020s 1900 2680 5590 7800 7800 11000

    suitability for isolation n n n n n nendurance (category A) (CO cycles) mechanical 10000 10000 10000 3000 3000 3000

    electrical AC AC22A 690V 1000 1000 1000 500 500 500AC23A 500V 1000 1000 1000

    electrical DC DC23A 250V 1000 1000 1000 500 500 500 (DC21A)positive contact indication yes yes yes yes yes yesdegree of pollution III III III III III IIIinstallationdimensions of 3 poles fixed FC (mm) W 230 280 280 340 340 340

    H 170 230 230 300 300 440D 99.5 118 118 118 118 200

    weight (kg) 3 poles, fixed, FC 2.7 4.3 4.8 12 15 35(1) Suitable for 480 V NEMA.(2) IN1000 and IN1600: 630A in AC23A.

    interpactMERLIN GERIN

    IN630

    IEC-VDE-BS-UTE

    Ui 660 Vlth 630AAC 22 630AAC 23 500A380/415V500 V

    I

    0 OFF

    Interpact IN630

    40 to 2500A: Interpactswitch-disconnector

    Interpact INS switch-disconnectors INS40 INS63 INS80 INS100 INS125 INS160number of poles 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4electrical characteristics as defined by IEC 947-3 and EN 60947-3conventional thermal current (A) Ith at 60C 40 63 80 100 125 160rated insulation voltage (V) Ui AC 50/60Hz 690 690 690 750 750 750rated impulse-withstand voltage (kV) Uimp 8 8 8 8 8 8rated operational voltage (V) Ue AC 50/60Hz 500 500 500 690 690 690

    DC 250 250 250 250 250 250rated operational current (A) Ie AC 50/60Hz AC 22 A AC 23 A AC 22 A AC 23 A AC 22 A AC 23 A AC 22 A AC 23 A AC 22 A AC 23 A AC 22 A AC 23 A

    220/240-380/415-440/480V (1) 40 40 63 63 80 80 100 100 125 125 160 160500V 40 32 63 40 80 63 100 100 125 125 160 160660/690V 100 63 125 80 160 100

    DC (4P in series) DC 22 A DC 23 A DC 22 A DC 23 A DC 22 A DC 23 A DC 22 A DC 23 A DC 22 A DC 23 A DC 22 A DC 23 A250V 40 40 63 63 80 80 100 100 125 125 160 160

    short-circuit Icm (kA peak) switch-disconnector alone 15 15 15 20 20 20making capacity with upstream protection 75 75 75 154 154 154short-time withstand current Icw (A rms) 1s 3000 3000 3000 5500 5500 5500

    3s 1730 1730 1730 3175 3175 317520s 670 670 670 1230 1230 1230

    suitability for isolation n n n n n nendurance (category A) (CO cycles) mechanical 20000 20000 20000 15000 15000 15000

    electrical AC AC22A 500V 3000 3000 3000 2000 2000 2000AC22A 690V 2000 2000 2000

    electrical AC AC23A 440V 3000 3000 3000 2000 2000 2000AC23A 500V 2000 (32A) 2000 (40A) 2000 (63A) 2000 2000 2000AC23A 690V 1500 (63A) 1500 (80A) 1500 (100A)

    electrical DC DC23A 250V 1500 1500 1500 1500 1500 1500positive contact indication yes yes yes yes yes yesdegree of pollution III III III III III IIIinstallationoverall dimensions of 3 poles (mm) W 90 90 90 135 135 135

    H 81 81 81 100 100 100D 62.5 62.5 62.5 62.5 62.5 62.5

    approximate weight (kg) 3 poles 0.5 0.5 0.5 0.8 0.8 0.8

  • 15Merlin Gerin

    B, C and D curvesApplicationControl and protection of circuits againstoverloads and short-circuits.c in domestic installations;c in commercial and industrial electricaldistribution systems.Technical datac current rating: 1 to 63 A at 30 C;c voltage rating: 230-400 V AC;c breaking capacity:rat. type voltage breaking(A) (V) capacity (A)to EN 608981 to 63 1P 230 10000

    2, 3P 400 10000to IEC 947-2 Icu1 to 63 1P 230-240 15000

    2, 3P 230-240 30000400-415 15000c positive contact indication;c fast closing;c number of operating cycles (0-C): 20000;c tripping characteristics:v B curve: the magnetic releases operate

    between 3 and 5 In,v C curve: the magnetic releases operatebetween 5 and 10 In,v D curve: the magnetic releases operatebetween 10 and 14 In;c tropicalization: treatment 2 (relativehumidity 95 % at 55 C);c weight (g):type 1P 2P 3P

    110 220 340c connection: tunnel terminals for rigidcables up to:v 25 mm2 for rating 25 A,v 35 mm2 for rating 63 A;c comb busbars 100 A - 40 Ctype No. mod. cat. No.1P 24 14881

    96 (set of 2 combs 48 mod.) 14891108 14801

    2P 96 (set of 2 combs 48 mod.) 14892108 14802

    3P 24 1488396 (set of 2 combs 48 mod.) 14893108 14803

    00000

    circuit protectioncircuit breakers up to 63 AC60H circuit breaker - EN 6089810000

    3type width rat. cat. No.

    in mod. (A) B C Dof 9 mm curve curve curve

    1P 2 0.512346101316202532405063

    2P 4 0.512346101316202532405063

    3P 6 0.512346101316202532405063

    1

    2

    3

    4

    ????

    1

    2

    ????

    00000

    00000

    1

    2

    3

    4

    5

    6

    ????

  • 14 Merlin Gerin

    type width rat. cat. No.in mod. (A) B C Dof 9 mm curve curve curve

    1P 2 0.512346101316202532405063

    2P 4 0.512346101316202532405063

    3P 6 0.512346101316202532405063

    B, C and D curvesApplicationControl and protection of circuits againstoverloads and short-circuits.c in domestic installations;c in commercial and industrial electricaldistribution systems.Technical datac current rating: 1 to 63 A at 30 C;c voltage rating: 230-400 V AC;c breaking capacity:rat. type voltage breaking(A) (V) capacity (A)to EN 608981 to 63 1P 230 6000

    2, 3P 400 6000to IEC 947-2 Icu1 to 63 1P 230-240 10000

    2, 3P 230-240 20000400-415 10000c number of operating cycles (0-C): 20000;c tripping characteristics:v B curve: the magnetic releases operate

    between 3 and 5 In,v C curve: the magnetic releases operatebetween 5 and 10 In,v D curve: the magnetic releases operatebetween 10 and 14 In;c tropicalization: treatment 2 (relativehumidity 95 % at 55 C);c weight (g):type 1P 2P 3P

    110 220 340c connection: tunnel terminals for rigidcables up to:v 25 mm2 for rating 25 A,v 35 mm2 for rating 63 A;c comb busbars 100 A - 40 Ctype No. mod. cat. No.1P 24 14881

    96 (set of 2 combs 48 mod.) 14891108 14801

    2P 96 (set of 2 combs 48 mod.) 14892108 14802

    3P 24 1488396 (set of 2 combs 48 mod.) 14893108 14803

    00000

    1

    2

    ????

    1

    2

    3

    4

    5

    6

    ????

    1

    2

    3

    4

    ????

    00000

    00000

    circuit protectioncircuit breakers up to 63 AC60N circuit breaker - EN 608986000

    3

    MCB-MCCB.PDFMCB C60H.pdfMCB C60N.pdf