Mechanical Seal Piping PlansSingle Seals Plans 01, 02, 11, 13, 14, 21, 23, 31, 32, 41
Dual Seals Plans 52, 53 A, 53 B, 53 C, 54
Quench Seals Plans 62, 65
Gas Seals Plans 72, 74, 75, 76
sealend view
internal porting
WhatInternal seal chamber flush from pump discharge.Operates similar to Plan 11.
WhySeal chamber heat removal.
Seal chamber venting on horizontal pumps.Reduce risk of freezing/polymerizing fluid in exposed Plan 11 piping.
WhereCustom seal chamber, most likely an ANSI/ASME pump.Clean, moderate temperature fluids.
Used with single seals, rarely with dual seals.
Preventative MaintenanceFlush typically can not be directed over seal faces and seal heat removal is limited.Calculate flush flow rate based on head loss through internal porting.
sealend view
open throat seal chamber shown
WhatDead-ended seal chamber with no flush.
WhyNo fluid recirculation needed.
WhereLarge bore/open throat seal chambers in moderate temperature services.Cooling jacket seal chambers in high temperature services.Clean fluids.
Top-entry mixers/agitators with dry seals.
Preventative MaintenanceProcess must have adequate boiling point margin to avoid vaporization.
Cooling fluid in seal chamber jacket may be needed at all times in hot services.Horizontal equipment must be self-venting.
Often used in combination with steam quench, Plan 62.
inlet
sealend view
orifice
WhatSeal flush from pump discharge through orifice.Default single seal flush plan.
WhySeal chamber heat removal.
Seal chamber venting on horizontal pumps.Increase seal chamber pressure and fluid vapor margin.
WhereGeneral applications with clean fluids.Clean, non-polymerizing fluids.
Preventative MaintenanceUse an orifice with a minimum 0.125" (3 mm) diameter.
Calculate flow rates to size orifice for adequate seal chamber flow.Increase boiling point margin with proper orifice and throat bushing sizing.Flush should be directed over seal faces with piping at 12 O’clock position.Typical failure mode is a clogged orifice - check temperatures at pipe ends.
outlet
sealend view
orifice
WhatRecirculation from seal chamber to pump suction through orifice.Standard flush plan on vertical pumps.
WhyContinuous seal chamber venting on vertical pumps.Seal chamber heat removal.
WhereVertical pumps.
Seal chamber pressure is greater than suction pressure.Moderate temperature fluids with moderate solids.Non-polymerizing fluids.
Preventative MaintenanceVent piping loop prior to starting vertical pumps.
Use an orifice with a minimum 0.125" (3 mm) diameter.Calculate flow rates to size orifice for adequate seal chamber flow.
Reduce seal chamber pressure with proper orifice and throat bushing sizing.Typical failure mode is a clogged orifice - check temperatures at pipe ends.
outlet
sealend view
inlet
orifices
WhatSeal flush from pump discharge and recirculation to pump suction with orifices.Combination of Plan 11 and Plan 13.
WhyContinuous seal chamber venting on vertical pumps.Seal chamber heat removal.
Increase seal chamber pressure and fluid vapor margin.
WhereVertical pumps.
Clean, non-polymerizing fluids at moderate temperatures.
Preventative MaintenanceUse an orifice with a minimum 0.125" (3 mm) diameter.
Calculate flow rates to size orifice for adequate seal chamber flow.Increase boiling point margin with proper orifice and throat bushing sizing.Flush should be directed over seal faces.
Vent piping loop prior to starting vertical pumps.Typical failure mode is a clogged orifice - check temperatures at pipe ends.
vents,normally closed
inlet
cooling outseal
end view
cooler cooling coils
orifice temperature cooling in
indicatordrain,
normallyclosed
WhatSeal flush from pump discharge through orifice and cooler.Cooler added to Plan 11 flush increases heat removal.
WhySeal cooling.
Reduce fluid temperature to increase fluid vapor margin.Reduce coking.
WhereHigh temperature service, typically less than 350°F (177°C).Hot water over 180°F (80°C).
Clean, non-polymerizing fluids.
Preventative MaintenanceSeal cooler and piping must have air vents at highest elevation - vent before starting.When using 682 Seal Cooler, pipe with series flow to maximize heat transfer.Use an orifice with a minimum 1/8" (3 mm) diameter.
Calculate flow rates to size orifice for adequate seal chamber flow.Increase boiling point margin with proper orifice and throat bushing sizing.
Regularly monitor cooler inlet and outlet temperatures for signs of clogging or fouling.
vent, normally closed
outlet
sealend view
inletcooler
temperatureindicator
cooling out
cooling coils
cooling in
drain,normally
closed
WhatSeal flush from internal pumping device through cooler.Standard flush plan in hot water services.
WhyEfficient seal cooling with low cooler duty.Increase fluid vapor margin.
Improve water lubricity.
WhereHigh temperature service, hot hydrocarbons.
Boiler feed water and hot water over 180°F (80°C).Clean, non-polymerizing fluids.
Preventative Maintenance - Reference Appendix ASeal cooler and piping must have air vents at highest elevation - vent before starting.When using 682 Seal Cooler, pipe with parallel flow to minimize head loss.Seal chamber requires close clearance throat bushing to isolate process fluid.Tangential seal gland taps should enter at bottom and exit at top.Regularly monitor cooler inlet and outlet temperatures for signs of clogging or fouling.Process fluids with iron should flow through magnetic separator before cooler.
inlet
sealend view
cyclone separator
WhatSeal flush from pump discharge through cyclone separator.Centrifuged solids are returned to pump suction.
WhySeal chamber heat removal.
Solids removal from flush and seal chamber.
WhereDirty or contaminated fluids, water with sand or pipe slag.Non-polymerizing fluids.
Preventative MaintenanceCyclone separator works best on solids with a specific gravity twice the process fluid.Seal chamber pressure must be nearly equal to suction pressure for proper flows.Piping should not include an orifice and is not expected to vent the seal chamber.Typical failure mode is clogged separator or pipes - check temperatures at pipe ends.
inlet
sealend view
pressureindicator
temperatureindicator
flow controlvalve
flow checkvalve(optional)
indicator from clean source,(optional) normally open
strainer
WhatSeal flush from an external clean source.
WhySeal chamber heat removal.
Process and solids removal from seal chamber.Increase seal chamber pressure and fluid vapor margin.
WhereDirty or contaminated fluids, paper pulp.High temperature service.
Polymerizing and/or oxidizing fluids.
Preventative MaintenanceUse throat bushing sized to hold pressure or maintain flow velocity.To restrict dirty process fluid, regulate injection flow rate.To increase fluid vapor margin, regulate injection pressure.Injection fluid must be compatible with process fluid.
Regularly monitor control system for closed valves or signs of plugging.
vents,normally closed
inlet
sealend view
cooler
cycloneseparator
temperatureindicator
cooling out
cooling coils
cooling in
drain,normallyclosed
WhatSeal flush from pump discharge through cyclone separator and cooler.Combination of Plan 21 and Plan 31.
WhySeal cooling.
Solids removal from flush and seal chamber.
WhereHigh temperature service, typically less than 350°F (177°C).Dirty or contaminated fluids, water with sand or pipe slag.Non-polymerizing fluids.
Preventative MaintenanceSeal cooler and piping must have air vents at highest elevation - vent before starting.When using 682 Seal Cooler, pipe with series flow to maximize heat transfer.Cyclone separator works best on solids with a specific gravity twice the process fluid.Seal chamber pressure must be nearly equal to suction pressure for proper flows.Typical failure mode is clogged separator or pipes - check temperatures at pipe ends.
vent,normally open
outlet
seal orificeend view
inlet liquid fill,normally closed
reservoir
cooling out
pressure indicator
pressure switch(high)
level switch (high)
level indicator
level switch (low)
cooling coilscooling in
drain,normally
closed
WhatUnpressurized buffer fluid circulation through reservoir.
Fluid is circulated by a pumping ring in the dual seal assembly.
WhyOutboard seal acts as a safety backup to the primary seal.Zero to very low process emissions.
No process contamination is allowed.
WhereUsed with dual unpressurized seals (“tandem”).High vapor pressure fluids, light hydrocarbons.Hazardous/toxic fluids.
Heat transfer fluids.
Preventative Maintenance - Reference Appendix BPiping loop must self-vent to vapor recovery/flare system near atmospheric pressure.Process vapor pressure is generally greater than reservoir pressure.Buffer fluid must be compatible with process leakage.Primary seal leakage is indicated by increased vent pressure.Reservoir level indicator shows outboard seal leakage.
pressure source,normally open
outlet
sealend view
inlet liquid fill,normally closed
reservoir
cooling out
drain,normally
closed
pressure indicator
pressure switch(low)
level switch (high)
level indicatorlevel switch (low)
cooling
coils
cooling in
WhatPressurized barrier fluid circulation through reservoir.
Fluid is circulated by a pumping ring in the dual seal assembly.
WhyIsolate process fluid.
Zero process emissions.
WhereUsed with dual pressurized seals (“double”).
High vapor pressure fluids, light hydrocarbons.Hazardous/toxic fluids.
Heat transfer fluids.Dirty/abrasive or polymerizing fluids.Mixers/agitators and vacuum service.
Preventative Maintenance - Reference Appendix BPiping loop must self-vent to reservoir located at highest elevation.
Pressurize reservoir at all times, maximum gas charge 150 - 200 psi (10 - 14 bar).Barrier fluid must be compatible with process.
Reservoir level indicator shows both inboard and outboard seal leakage.
vent,normally closed
pressure
outlet
sealend view
inlet
indicator
pressure source,normally closed
bladderaccumulator
temperature indicator
drain,
pressure switch(low)
finned (alternativepipe reservoir)
liquid fill,normally closed
normallyclosed
WhatPressurized barrier fluid circulation with bladder accumulator.Fluid is circulated by a pumping ring in the dual seal assembly.
WhyIsolate process fluid.
Zero process emissions.Higher pressure than Plan 53A.
WhereUsed with dual pressurized seals (“double”).
High vapor pressure fluids, light hydrocarbons.Hazardous/toxic fluids.
Heat transfer fluids.Dirty/abrasive or polymerizing fluids.
Preventative Maintenance - Reference Appendix BPiping loop must be fully vented before starting.
Accumulator must be pressurized at all times, usually by gas charge.Barrier fluid must be compatible with process.
Regularly monitor barrier pressure - manually add barrier fluid when pressure decays.
outlet
sealend view
inlet
level indicatorlevel switch (low)co
oling out
liquid fill,normallyclosed
coolingcoils
temperatureindicator
vent,normally closed
pressure reliefvalve
pressure indicator
pressure switch(low)
cooling in
drain,normallyclosed
WhatPressurized barrier fluid circulation with piston accumulator.Fluid is circulated by a pumping ring in the dual seal assembly.
WhyIsolate process fluid.
Zero process emissions.Higher pressure than Plan 53A.
Dynamic tracking of system pressure.
WhereUsed with dual pressurized seals (“double”).
High vapor pressure fluids, light hydrocarbons.Hazardous/toxic fluids.
Heat transfer fluids.
Preventative Maintenance - Reference Appendix BPiping loop must be fully vented before starting.
Reference line must tolerate process contamination without plugging.Barrier fluid must be compatible with process.
Reservoir level indicator indicates both inboard and outboard seal leakage.
outlet
sealend view
inlet
from / to externalcirculating system
WhatPressurized barrier fluid circulation by external system.
WhyIsolate process fluid.
Zero process emissions.Seal cannot induce circulation.
WhereUsed with dual pressurized seals (“double”).
High vapor pressure fluids, light hydrocarbons.Hazardous/toxic fluids.
Heat transfer fluids.Dirty/abrasive or polymerizing fluids.Mixers/agitators.
Preventative MaintenancePiping loop must be fully vented before starting.
Circulating system must be pressurized and energized at all times.Barrier fluid must be compatible with process.
Circulating system level indicator shows both inboard and outboard seal leakage.
inlet
sealend view
drain drain,normally
open
pressureindicator
(optional) steam trap(steam quench)
check valve
quench,normally
open
WhatExternal quench on atmospheric side of seal.
Quench fluids typically steam, nitrogen, or water.
WhyPrevent solids buildup on atmospheric side of seal.Prevent icing.
WhereUsed with single seals.
Oxidizing fluids or fluids that coke, hot hydrocarbons.Crystallizing fluids or fluids that salt out.Caustic.
Cold fluids less than 32°F (0°C).
Preventative MaintenanceQuench inlet should be on top of gland with outlet/drain on bottom.Quench pressure should be limited to 3 psi (0.2 bar) or less.
Use throttle bushing on atmospheric side of seal to direct quench flow to seal drain.Monitor regularly, checking for closed valves, blocked lines, and steam trap condition.
sealend view
blockvalve, level switchnormally (high)
open overflowcham
ber
bypassorifice line
drain,normally
open
WhatExternal drain with leakage detection on atmospheric side of seal.
WhyLeakage collection for process leakage or quench fluid.Safety indicator for primary seal to detect failure.
WhereMay be used alone or with Plan 62 quench.Used with close clearance throttle bushing.
Useful with single seals in remote locations and critical services.
Preventative MaintenanceDrain must be on bottom of gland with downward-sloped piping.Continuously drain to liquid recovery system.
Orifice downstream of level switch typically 1/4” (5 mm) must be oriented vertically.Bypass line from overflow chamber must re-enter below orifice.Piping may require heat tracing when used with solidifying fluids.Monitor regularly, checking for closed valves, blocked lines, and working level switch.
1 - drain
vent
inletseal
end view GH
drain
2
1 F
2 - vent3 - gas inlet, normally open
4 - filter drain, normally closed
B
A
3C
D 4
A - coalescing filterE B - regulator
C - pressure indicatorD - pressure switch (low)E- orifice
F - flow indicatorG - flow switch (high)H - check valve
WhatUnpressurized buffer gas control system.
Containment seal support typically with nitrogen buffer gas.
WhyZero to very low process emissions.Safety backup to primary seal.
WhereUsed with dual unpressurized containment seals (“tandem”).High vapor pressure fluids, light hydrocarbons.Hazardous/toxic fluids.
Clean, non-polymerizing, non-oxidizing fluids.Used in combination with Plan 75 and/or Plan 76.
Preventative MaintenanceClean, reliable, low pressure gas must be supplied to seal at all times.
Bottled gas supply is not recommended except as part of emergency backup system.Primary seal leakage is indicated by pressure in the vent line.
Vent or drain are usually connected to low pressure vapor recovery/flare system.
1 - upset drain, normally closed2 - gas inlet, normally open
inletseal
end view
drain
1
3 - filter drain, normally closed
FE
G
D
2 A B
C
3A - coalescing filterB - regulator
C - flow indicatorD - flow switch (high)E- pressure switch (low)F- pressure indicatorG - check valve
WhatPressurized barrier gas control system.
Gas seal support typically with nitrogen barrier gas.
WhyIsolate process fluid.
Zero process emissions.
WhereUsed with dual pressurized gas seals (“double”).High vapor pressure fluids, light hydrocarbons.Hazardous/toxic fluids.Services that do not tolerate liquid barrier seals.Clean, non-polymerizing fluids.
Moderate temperature fluids.
Preventative MaintenanceClean, reliable, pressurized gas must be supplied to seal at all times.
Barrier pressure is typically at least 25 psig (1.75 bar) above seal chamber pressure.Flow indicator shows both inboard and outboard seal leakage.Bottled gas supply is not recommended except as part of emergency backup system.
isolation
sealend view
leveldrain indicator
valve vent,pressure switch normally
(high)
openpressure
indicatororifice
level switch (high)
reservoir locatedbelow seal drain port
drain,normally
closed
WhatDrain from containment seal cavity to liquid collector and vapor recovery.
WhyLeakage collection for zero to very low process emissions.Safety indicator for primary seal.
WhereMay be used alone or with Plan 72 on containment seals.Fluids that condense at ambient temperature.High vapor pressure fluids, light hydrocarbons.Hazardous/toxic fluids.
Clean, non-polymerizing, non-oxidizing fluids.
Preventative MaintenanceCollection reservoir must be located below seal drain and downward-sloped piping.Continuously vent collection reservoir to low pressure vapor recovery/flare system.Drain collection reservoir to liquid recovery system as needed.Primary seal leakage is indicated by increased vent pressure.Monitor regularly for liquid level, valve settings, and low vent pressure.
vent
sealend view
draindrain,
normallyclosed
vent,normally open
orifice pressure indicator
pressure switch (high)
drain,normally closed
WhatVent from containment seal cavity to vapor recovery.
WhyLeakage collection for zero to very low process emissions.Safety indicator for primary seal.
WhereMay be used alone or with Plan 72 on containment seals.Fluids that do not condense at ambient temperature.High vapor pressure fluids, light hydrocarbons.Hazardous/toxic fluids.
Clean, non-polymerizing, non-oxidizing fluids.
Preventative MaintenanceContinuously vent to low pressure vapor recovery/flare system.Vent piping should include a condensate drain.Primary seal leakage is indicated by increased vent pressure.
Monitor regularly for valve settings, blocked lines, and low vent pressure.