Automated Radiation Therapy Phantom Analysis in Seconds
So much is asked ofmedical physicists these days
We Can Help
QC for Therapy OBI’s and CT simulators.Radia’s Catphan/OBI module performs analysis of kV and MV Cone Beam CT images using the
Catphan or Siemens phantoms. Phantom images for Varian, Elekta and Siemans Cone Beam CTs are
measured automatically and compared to manufacture recommendations and then given both Pass/
Fail and numeric results.
Radia’s Electron Density/Tissue Characterization
Module eliminates many manual steps by automatically
evaluating the density areas in the CIRS, Gammex, or
Tomo Cheese phantoms. And, it’s no longer necessary to
move the ROI around within each density plug to identify
the best sample location. This module automatically
optimizes the position of the density sample to get the
most uniform value for the measurement, saving you lots
of time and giving you the highest accuracy.
RITtrend allows you to effectively manage all your physics QA data in one powerful and customizable package.
RITtrend allows you to tag your data with customizable fields enabling you to design,
store and recall queries producing the exact data you want to view and analyze.
RITtrend allows you to design and store multiple specification sets for your
data so you can be alerted when your data exceeds those specifications. Use
standard specification sets from TG142 or customize your own. RITtrend
allows you to define baselines for your data so you can look at your
data relative to the baseline or in absolute terms. A must for TG142
compliance! The new Multi Source Data Manager’s customizable format
allows you to add analysis data from any and all equipment used in
your Medical Physics program.
Phantom images are measured automatically and given both Pass/Fail and numeric results.
One size does not fit all. Radia is available for the individual practitioner, networked groups, and even as an
OEM component.
Radia Solo Radia Group Radia Enabled
Individual and Multi-Seat
Stand alone units for the single practitioner, or group who does not need any special
modification.
Multi-Seats/Groups/Facilities
Group packages with some modifications, custom
requirements, or even a network system.
Built-Ins
Boost your own product or system with Radia inside.
Interfaces, installed components, and network systems.
Who:•PracticingPhysicists
•PhysicsGroups
• ImagingCenters
•Hospitals
Who:• ImagingCenters
•PhysicsGroups
•Hospitals&HealthCareSystems
•PhantomManufacturers
• ImagingEquipment&SoftwareOEM’s
•ServiceCompanies
•EquipmentRefurbishers
Who:• ImagingEquipment&SoftwareOEM’s
What:•“AsIs”ModulesfromthecurrentRadiaversion
What:•Multi-seatpackages
•CustomModulescombinedfromthecurrentRadiaversion
•CustomdesignedModules
•PrivateLabelBranding
•EnterpriseNetworkOptionusinglocalnetwork/intranet/serverservice
What:•Multi-seatpackages
•CustomModulescombinedfromthecurrentRadiaversion
•CustomdesignedModules
•PrivateLabelBranding
•EnterpriseNetworkOptionusinglocalnetwork/intranet/serverservice
• Interfacestotrackingandmanagementsoftwaresystems
• Installedcomponentsinimagingequipment
Choose from three different Radia packages
CatphanisaRegisteredtrademarkofThePhantomLaboratoriesPrimusisaRegisteredtrademarkofIBACyberknifeisaRegisteredtrademarkofAccurayNORMI4isaRegisteredtrademarkofPTW
©RadiologicalImagingTechnology,Inc.,July,2012
Radia Therapy Module and Test Radia Therapy Outputs
Catphan/OBI, kV/MV & Cone Beam CT Phantoms CompleteAutomaticscoringofallphantomparameters.
Varian504Catphan MeasuresandplotsmaterialvaluesandCTnumberlinearity.Measures:slicewidth,rampalignment,roddistances,lowcontrastdetectability,measuresuniformity,integralnon-uniformity,plotsintegralnon-uniformityprofile,contrast-to-noise,scoreslowcontrastobjects,measuresandplotsMTF.
Elekta503Catphan(XVI) MeasuresandplotsmaterialvaluesandCTnumberlinearity.Measures:slicewidth,rampalignment,roddistances,lowcontrastdetectability,measuresuniformity,integralnon-uniformity,plotsintegralnon-uniformityprofile,measuresandplotsMTF,uniformitymeandifference,lowcontrastvisibility.
SiemensImageQualityPhantom Geometricalmeasurements,centralareameanandstandarddeviation,uniformitymeasurements,measuresandplotsMTF,lowcontrasttargetscoring.
Catphan500/600 MeasuresandplotsmaterialvaluesandCTnumberlinearity.Measures:slicewidth,rampalignment,roddistances,lowcontrastdetectability,measuresuniformity,integralnon-uniformity,plotsintegralnon-uniformityprofile,contrast-to-noise,scoreslowcontrastobjects,measuresandplotsMTF.
Electron Density/Tissue Characterization Phantoms
CIRS062+062A(conebeam) Measuresandplots17densityareas.
Gammex467 Measuresandplots17densityareas.GeometricmeasurementinXandYdirection.
TomoCheese Measuresandplots20densityareas.
PTWEPIDQCPhantom(26cmx26cmtestareaatisocenter!–LARGEAREAtesting)
Mean,standarddeviation,andsignaltonoiseforeachofthe10coppersteps.Meanvalueforeachofthefourobjectsinthesixbrasssteps,horizontalandverticalspacingforgeometricaccuracy,MTFreportedandplottedforresolutionpattern,contrastisreportedforeachofthe27contrastobjects.
QC-3 Contrast,resolution
LasVegas Contrast
DR/CR/Fluoro kV Imaging Phantoms
•DISCPlus• IBAPrimusL•PTWNormi-4
Mean,standarddeviationandcontrastratioforeachstep,contrast-to-noiseratioforeachlowcontrastobject,uniformityandnoise,MTFreportedfortheresolutionpattern,geometricdistortionmeasurement.
LeedsTOR18FG Contrast,resolution
kV/MV Imager Coincidence Phantoms
CIRSISOCube kV/MVimagecoincidenceandpositioning,kVandMVradiation/lightfieldalignment,magnification,laserlocalization,CBCTalignment,tableheightaccuracy.
DICOMimageviewerandDICOMtagviewer
Severalmethodstolocateandimportyourimages DICOMdirectorybrowser,opendirectorybrowser,DICOMfilefilterfororganizingyourimages.
Batchprocessingofimages
Database AllmeasurementscanbetrackedandplottedovertimeintheRITtrend™database.Anynumberofdatabasescanbeused.AllStatisticalProcessControlparametersmeasuredandplotted.
MonitorImageQuality SMPTEpatternandTG18images
ManualMeasurements Distance,angle,profile,histograms,roundandsquareROI.ASCIIoutputofprofiles
OutputFormats Print,PDF,Excel(withcustomtemplates),XML
ImageTransfer BuiltinimageFTPfunction
Catp
han/O
BI, k
V/M
V &
Cone B
eam
Ele
ctr
on D
ensi
tyE
PID
QC
DR
/CR
/Flu
oro
kV
kV
/MV
Base
Module
s
Analyze large batches and even historical data that you’ve archived in just minutes.
Radia’s RunQueueC scripting feature provides fast, easy
batch analysis that can be performed on entire directories
of images in a single operation. After a simple set-
up establishing your personal protocols, choose image
batches from one machine, a group of machines, or even
machines located throughout a hospital system. Reports are
automatically generated with pass/fails clearly indicated,
and added to the RITtrend™ database which shows you image quality measurements over time.
After your one-time setup, use it again and again. Or better yet, have someone else do it for you,
again and again.
It’s On Everyone’s Minds. Meeting TG142 Best Practice Guidelines.
Radia and RIT113 Classic performs or trends EVERY daily, weekly, monthly and annual imaging and
dosimetry test recommended in TG142. A medical physics department with the RIT package and
corresponding phantoms has everything they need. Please refer to the RIT TG142 datasheet for a
complete list.
Our DR/CR/Fluoro Module kV imaging tests are used to measure the full field performance of OBI
systems on Linacs and Cyberknife. Complete tests of Contrast, Uniformity, Noise, Modulation, kV,
and Geometric Distortion are performed over large field
areas ( 30 cm x 30 cm ). These tests ensure compliance
with the TG142 Table 6 recommendations for Planar kV
imaging.
Radia’s PTW Epid QC Module confirms the EPID image
quality by measuring Signal to Noise in multiple areas,
Geometric Accuracy, Resolution, and Contrast over
large imaging areas (26x26 cm at isocenter), exceeding
TG142 table 6 recommendations for MV imaging.
Radia gives you the same results you get from your own analysis, but a whole lot faster.
Clinical studies show that Radia analysis is equal to trained observers in every comparison, and
because it is objective, consistent and repeatable the need for review is completely eliminated. Our
incredibly fast batch analysis is an added bonus that takes it to a whole
new level. Because it’s so quick, users report that they are able to do
ALL of the image analysis that’s required for TG142 compliance! That’s
a big leap in image quality and efficiency.
Or better yet, have someone else do it for you.
Chooseanunlimitednumberofimagestocreateabatchandexecuteoneofyourpre-establishedprotocolstoauto-generatereports
Select Analysis Routine
Selectfromoptionstocreateanunlimitednumberofreusableanalysisprotocols&reportingscripts
Select Your Images
Individuallyanalyzeanynumberofimagesinseconds.
Click Analyze
A medical physics department with the RIT package and corresponding phantoms has everything they need.
A big leap in image quality and efficiency
Plan your service downtime at your departments’ convenience.
Our RITtrend™ Statistical Process Control analysis shows you how your equipment performs over
time and shows you decline in image quality before it falls below minimums. You can schedule
service at your convenience before the machine has to go down.
Delegate with Complete ConfidenceRadia lets you train a therapist to easily perform daily, weekly or any QC checks with automated
analysis and reports that keep you informed. Setup is quick and easy for you, and then with one
click by a staff member Radia automatically performs the objective analysis and generates reports
to the RITtrend™ database, other system of your choice, or output reports that can be sent to you.
Red/Green light notifications identify when image quality is within or outside of your specifications.
You can have the confidence that image quality is correctly measured no matter who executes the
testing!
Radia’s imaging scoring algorithms are adjustable. Radia’s default values are set to score from the average of a group of Physicists, but you can easily
adjust and set the sensitivity of each scoring module to match your own observations.
With one click, Radia automatically performs the objective analysis and generates reports. Radia Sequencer
The NEW Radia Sequencer allows users to populate the Radia RunQueueC work list with a
predefined set of images and analyses in just a single click. The user can define any number of
custom sequences using the sequence editor. The sequences can pull slices from absolute or
relative slice locations and even average over several slices as they are imported. Once imported a
single click will analyze the entire image set at once!
Analyze large batches and even historical data that you’ve archived in just minutes.
Radia’s RunQueueC scripting feature provides fast, easy
batch analysis that can be performed on entire directories
of images in a single operation. After a simple set-
up establishing your personal protocols, choose image
batches from one machine, a group of machines, or even
machines located throughout a hospital system. Reports are
automatically generated with pass/fails clearly indicated,
and added to the RITtrend™ database which shows you image quality measurements over time.
After your one-time setup, use it again and again. Or better yet, have someone else do it for you,
again and again.
It’s On Everyone’s Minds. Meeting TG142 Best Practice Guidelines.
Radia and RIT113 Classic performs or trends EVERY daily, weekly, monthly and annual imaging and
dosimetry test recommended in TG142. A medical physics department with the RIT package and
corresponding phantoms has everything they need. Please refer to the RIT TG142 datasheet for a
complete list.
Our DR/CR/Fluoro Module kV imaging tests are used to measure the full field performance of OBI
systems on Linacs and Cyberknife. Complete tests of Contrast, Uniformity, Noise, Modulation, kV,
and Geometric Distortion are performed over large field
areas ( 30 cm x 30 cm ). These tests ensure compliance
with the TG142 Table 6 recommendations for Planar kV
imaging.
Radia’s PTW Epid QC Module confirms the EPID image
quality by measuring Signal to Noise in multiple areas,
Geometric Accuracy, Resolution, and Contrast over
large imaging areas (26x26 cm at isocenter), exceeding
TG142 table 6 recommendations for MV imaging.
Radia gives you the same results you get from your own analysis, but a whole lot faster.
Clinical studies show that Radia analysis is equal to trained observers in every comparison, and
because it is objective, consistent and repeatable the need for review is completely eliminated. Our
incredibly fast batch analysis is an added bonus that takes it to a whole
new level. Because it’s so quick, users report that they are able to do
ALL of the image analysis that’s required for TG142 compliance! That’s
a big leap in image quality and efficiency.
Or better yet, have someone else do it for you.
Chooseanunlimitednumberofimagestocreateabatchandexecuteoneofyourpre-establishedprotocolstoauto-generatereports
Select Analysis Routine
Selectfromoptionstocreateanunlimitednumberofreusableanalysisprotocols&reportingscripts
Select Your Images
Individuallyanalyzeanynumberofimagesinseconds.
Click Analyze
A medical physics department with the RIT package and corresponding phantoms has everything they need.
A big leap in image quality and efficiency
Plan your service downtime at your departments’ convenience.
Our RITtrend™ Statistical Process Control analysis shows you how your equipment performs over
time and shows you decline in image quality before it falls below minimums. You can schedule
service at your convenience before the machine has to go down.
Delegate with Complete ConfidenceRadia lets you train a therapist to easily perform daily, weekly or any QC checks with automated
analysis and reports that keep you informed. Setup is quick and easy for you, and then with one
click by a staff member Radia automatically performs the objective analysis and generates reports
to the RITtrend™ database, other system of your choice, or output reports that can be sent to you.
Red/Green light notifications identify when image quality is within or outside of your specifications.
You can have the confidence that image quality is correctly measured no matter who executes the
testing!
Radia’s imaging scoring algorithms are adjustable. Radia’s default values are set to score from the average of a group of Physicists, but you can easily
adjust and set the sensitivity of each scoring module to match your own observations.
With one click, Radia automatically performs the objective analysis and generates reports. Radia Sequencer
The NEW Radia Sequencer allows users to populate the Radia RunQueueC work list with a
predefined set of images and analyses in just a single click. The user can define any number of
custom sequences using the sequence editor. The sequences can pull slices from absolute or
relative slice locations and even average over several slices as they are imported. Once imported a
single click will analyze the entire image set at once!
Analyze large batches and even historical data that you’ve archived in just minutes.
Radia’s RunQueueC scripting feature provides fast, easy
batch analysis that can be performed on entire directories
of images in a single operation. After a simple set-
up establishing your personal protocols, choose image
batches from one machine, a group of machines, or even
machines located throughout a hospital system. Reports are
automatically generated with pass/fails clearly indicated,
and added to the RITtrend™ database which shows you image quality measurements over time.
After your one-time setup, use it again and again. Or better yet, have someone else do it for you,
again and again.
It’s On Everyone’s Minds. Meeting TG142 Best Practice Guidelines.
Radia and RIT113 Classic performs or trends EVERY daily, weekly, monthly and annual imaging and
dosimetry test recommended in TG142. A medical physics department with the RIT package and
corresponding phantoms has everything they need. Please refer to the RIT TG142 datasheet for a
complete list.
Our DR/CR/Fluoro Module kV imaging tests are used to measure the full field performance of OBI
systems on Linacs and Cyberknife. Complete tests of Contrast, Uniformity, Noise, Modulation, kV,
and Geometric Distortion are performed over large field
areas ( 30 cm x 30 cm ). These tests ensure compliance
with the TG142 Table 6 recommendations for Planar kV
imaging.
Radia’s PTW Epid QC Module confirms the EPID image
quality by measuring Signal to Noise in multiple areas,
Geometric Accuracy, Resolution, and Contrast over
large imaging areas (26x26 cm at isocenter), exceeding
TG142 table 6 recommendations for MV imaging.
Radia gives you the same results you get from your own analysis, but a whole lot faster.
Clinical studies show that Radia analysis is equal to trained observers in every comparison, and
because it is objective, consistent and repeatable the need for review is completely eliminated. Our
incredibly fast batch analysis is an added bonus that takes it to a whole
new level. Because it’s so quick, users report that they are able to do
ALL of the image analysis that’s required for TG142 compliance! That’s
a big leap in image quality and efficiency.
Or better yet, have someone else do it for you.
Chooseanunlimitednumberofimagestocreateabatchandexecuteoneofyourpre-establishedprotocolstoauto-generatereports
Select Analysis Routine
Selectfromoptionstocreateanunlimitednumberofreusableanalysisprotocols&reportingscripts
Select Your Images
Individuallyanalyzeanynumberofimagesinseconds.
Click Analyze
A medical physics department with the RIT package and corresponding phantoms has everything they need.
A big leap in image quality and efficiency
Plan your service downtime at your departments’ convenience.
Our RITtrend™ Statistical Process Control analysis shows you how your equipment performs over
time and shows you decline in image quality before it falls below minimums. You can schedule
service at your convenience before the machine has to go down.
Delegate with Complete ConfidenceRadia lets you train a therapist to easily perform daily, weekly or any QC checks with automated
analysis and reports that keep you informed. Setup is quick and easy for you, and then with one
click by a staff member Radia automatically performs the objective analysis and generates reports
to the RITtrend™ database, other system of your choice, or output reports that can be sent to you.
Red/Green light notifications identify when image quality is within or outside of your specifications.
You can have the confidence that image quality is correctly measured no matter who executes the
testing!
Radia’s imaging scoring algorithms are adjustable. Radia’s default values are set to score from the average of a group of Physicists, but you can easily
adjust and set the sensitivity of each scoring module to match your own observations.
With one click, Radia automatically performs the objective analysis and generates reports. Radia Sequencer
The NEW Radia Sequencer allows users to populate the Radia RunQueueC work list with a
predefined set of images and analyses in just a single click. The user can define any number of
custom sequences using the sequence editor. The sequences can pull slices from absolute or
relative slice locations and even average over several slices as they are imported. Once imported a
single click will analyze the entire image set at once!
Automated Radiation Therapy Phantom Analysis in Seconds
So much is asked ofmedical physicists these days
We Can Help
QC for Therapy OBI’s and CT simulators.Radia’s Catphan/OBI module performs analysis of kV and MV Cone Beam CT images using the
Catphan or Siemens phantoms. Phantom images for Varian, Elekta and Siemans Cone Beam CTs are
measured automatically and compared to manufacture recommendations and then given both Pass/
Fail and numeric results.
Radia’s Electron Density/Tissue Characterization
Module eliminates many manual steps by automatically
evaluating the density areas in the CIRS, Gammex, or
Tomo Cheese phantoms. And, it’s no longer necessary to
move the ROI around within each density plug to identify
the best sample location. This module automatically
optimizes the position of the density sample to get the
most uniform value for the measurement, saving you lots
of time and giving you the highest accuracy.
RITtrend allows you to effectively manage all your physics QA data in one powerful and customizable package.
RITtrend allows you to tag your data with customizable fields enabling you to design,
store and recall queries producing the exact data you want to view and analyze.
RITtrend allows you to design and store multiple specification sets for your
data so you can be alerted when your data exceeds those specifications. Use
standard specification sets from TG142 or customize your own. RITtrend
allows you to define baselines for your data so you can look at your
data relative to the baseline or in absolute terms. A must for TG142
compliance! The new Multi Source Data Manager’s customizable format
allows you to add analysis data from any and all equipment used in
your Medical Physics program.
Phantom images are measured automatically and given both Pass/Fail and numeric results.
One size does not fit all. Radia is available for the individual practitioner, networked groups, and even as an
OEM component.
Radia Solo Radia Group Radia Enabled
Individual and Multi-Seat
Stand alone units for the single practitioner, or group who does not need any special
modification.
Multi-Seats/Groups/Facilities
Group packages with some modifications, custom
requirements, or even a network system.
Built-Ins
Boost your own product or system with Radia inside.
Interfaces, installed components, and network systems.
Who:•PracticingPhysicists
•PhysicsGroups
• ImagingCenters
•Hospitals
Who:• ImagingCenters
•PhysicsGroups
•Hospitals&HealthCareSystems
•PhantomManufacturers
• ImagingEquipment&SoftwareOEM’s
•ServiceCompanies
•EquipmentRefurbishers
Who:• ImagingEquipment&SoftwareOEM’s
What:•“AsIs”ModulesfromthecurrentRadiaversion
What:•Multi-seatpackages
•CustomModulescombinedfromthecurrentRadiaversion
•CustomdesignedModules
•PrivateLabelBranding
•EnterpriseNetworkOptionusinglocalnetwork/intranet/serverservice
What:•Multi-seatpackages
•CustomModulescombinedfromthecurrentRadiaversion
•CustomdesignedModules
•PrivateLabelBranding
•EnterpriseNetworkOptionusinglocalnetwork/intranet/serverservice
• Interfacestotrackingandmanagementsoftwaresystems
• Installedcomponentsinimagingequipment
Choose from three different Radia packages
CatphanisaRegisteredtrademarkofThePhantomLaboratoriesPrimusisaRegisteredtrademarkofIBACyberknifeisaRegisteredtrademarkofAccurayNORMI4isaRegisteredtrademarkofPTW
©RadiologicalImagingTechnology,Inc.,July,2012
Radia Therapy Module and Test Radia Therapy Outputs
Catphan/OBI, kV/MV & Cone Beam CT Phantoms CompleteAutomaticscoringofallphantomparameters.
Varian504Catphan MeasuresandplotsmaterialvaluesandCTnumberlinearity.Measures:slicewidth,rampalignment,roddistances,lowcontrastdetectability,measuresuniformity,integralnon-uniformity,plotsintegralnon-uniformityprofile,contrast-to-noise,scoreslowcontrastobjects,measuresandplotsMTF.
Elekta503Catphan(XVI) MeasuresandplotsmaterialvaluesandCTnumberlinearity.Measures:slicewidth,rampalignment,roddistances,lowcontrastdetectability,measuresuniformity,integralnon-uniformity,plotsintegralnon-uniformityprofile,measuresandplotsMTF,uniformitymeandifference,lowcontrastvisibility.
SiemensImageQualityPhantom Geometricalmeasurements,centralareameanandstandarddeviation,uniformitymeasurements,measuresandplotsMTF,lowcontrasttargetscoring.
Catphan500/600 MeasuresandplotsmaterialvaluesandCTnumberlinearity.Measures:slicewidth,rampalignment,roddistances,lowcontrastdetectability,measuresuniformity,integralnon-uniformity,plotsintegralnon-uniformityprofile,contrast-to-noise,scoreslowcontrastobjects,measuresandplotsMTF.
Electron Density/Tissue Characterization Phantoms
CIRS062+062A(conebeam) Measuresandplots17densityareas.
Gammex467 Measuresandplots17densityareas.GeometricmeasurementinXandYdirection.
TomoCheese Measuresandplots20densityareas.
PTWEPIDQCPhantom(26cmx26cmtestareaatisocenter!–LARGEAREAtesting)
Mean,standarddeviation,andsignaltonoiseforeachofthe10coppersteps.Meanvalueforeachofthefourobjectsinthesixbrasssteps,horizontalandverticalspacingforgeometricaccuracy,MTFreportedandplottedforresolutionpattern,contrastisreportedforeachofthe27contrastobjects.
QC-3 Contrast,resolution
LasVegas Contrast
DR/CR/Fluoro kV Imaging Phantoms
•DISCPlus• IBAPrimusL•PTWNormi-4
Mean,standarddeviationandcontrastratioforeachstep,contrast-to-noiseratioforeachlowcontrastobject,uniformityandnoise,MTFreportedfortheresolutionpattern,geometricdistortionmeasurement.
LeedsTOR18FG Contrast,resolution
kV/MV Imager Coincidence Phantoms
CIRSISOCube kV/MVimagecoincidenceandpositioning,kVandMVradiation/lightfieldalignment,magnification,laserlocalization,CBCTalignment,tableheightaccuracy.
DICOMimageviewerandDICOMtagviewer
Severalmethodstolocateandimportyourimages DICOMdirectorybrowser,opendirectorybrowser,DICOMfilefilterfororganizingyourimages.
Batchprocessingofimages
Database AllmeasurementscanbetrackedandplottedovertimeintheRITtrend™database.Anynumberofdatabasescanbeused.AllStatisticalProcessControlparametersmeasuredandplotted.
MonitorImageQuality SMPTEpatternandTG18images
ManualMeasurements Distance,angle,profile,histograms,roundandsquareROI.ASCIIoutputofprofiles
OutputFormats Print,PDF,Excel(withcustomtemplates),XML
ImageTransfer BuiltinimageFTPfunction
Catp
han/O
BI, k
V/M
V &
Cone B
eam
Ele
ctr
on D
ensi
tyE
PID
QC
DR
/CR
/Flu
oro
kV
kV
/MV
Base
Module
s
Automated Radiation Therapy Phantom Analysis in Seconds
So much is asked ofmedical physicists these days
We Can Help
QC for Therapy OBI’s and CT simulators.Radia’s Catphan/OBI module performs analysis of kV and MV Cone Beam CT images using the
Catphan or Siemens phantoms. Phantom images for Varian, Elekta and Siemans Cone Beam CTs are
measured automatically and compared to manufacture recommendations and then given both Pass/
Fail and numeric results.
Radia’s Electron Density/Tissue Characterization
Module eliminates many manual steps by automatically
evaluating the density areas in the CIRS, Gammex, or
Tomo Cheese phantoms. And, it’s no longer necessary to
move the ROI around within each density plug to identify
the best sample location. This module automatically
optimizes the position of the density sample to get the
most uniform value for the measurement, saving you lots
of time and giving you the highest accuracy.
RITtrend allows you to effectively manage all your physics QA data in one powerful and customizable package.
RITtrend allows you to tag your data with customizable fields enabling you to design,
store and recall queries producing the exact data you want to view and analyze.
RITtrend allows you to design and store multiple specification sets for your
data so you can be alerted when your data exceeds those specifications. Use
standard specification sets from TG142 or customize your own. RITtrend
allows you to define baselines for your data so you can look at your
data relative to the baseline or in absolute terms. A must for TG142
compliance! The new Multi Source Data Manager’s customizable format
allows you to add analysis data from any and all equipment used in
your Medical Physics program.
Phantom images are measured automatically and given both Pass/Fail and numeric results.
One size does not fit all. Radia is available for the individual practitioner, networked groups, and even as an
OEM component.
Radia Solo Radia Group Radia Enabled
Individual and Multi-Seat
Stand alone units for the single practitioner, or group who does not need any special
modification.
Multi-Seats/Groups/Facilities
Group packages with some modifications, custom
requirements, or even a network system.
Built-Ins
Boost your own product or system with Radia inside.
Interfaces, installed components, and network systems.
Who:•PracticingPhysicists
•PhysicsGroups
• ImagingCenters
•Hospitals
Who:• ImagingCenters
•PhysicsGroups
•Hospitals&HealthCareSystems
•PhantomManufacturers
• ImagingEquipment&SoftwareOEM’s
•ServiceCompanies
•EquipmentRefurbishers
Who:• ImagingEquipment&SoftwareOEM’s
What:•“AsIs”ModulesfromthecurrentRadiaversion
What:•Multi-seatpackages
•CustomModulescombinedfromthecurrentRadiaversion
•CustomdesignedModules
•PrivateLabelBranding
•EnterpriseNetworkOptionusinglocalnetwork/intranet/serverservice
What:•Multi-seatpackages
•CustomModulescombinedfromthecurrentRadiaversion
•CustomdesignedModules
•PrivateLabelBranding
•EnterpriseNetworkOptionusinglocalnetwork/intranet/serverservice
• Interfacestotrackingandmanagementsoftwaresystems
• Installedcomponentsinimagingequipment
Choose from three different Radia packages
CatphanisaRegisteredtrademarkofThePhantomLaboratoriesPrimusisaRegisteredtrademarkofIBACyberknifeisaRegisteredtrademarkofAccurayNORMI4isaRegisteredtrademarkofPTW
©RadiologicalImagingTechnology,Inc.,July,2012
Radia Therapy Module and Test Radia Therapy Outputs
Catphan/OBI, kV/MV & Cone Beam CT Phantoms CompleteAutomaticscoringofallphantomparameters.
Varian504Catphan MeasuresandplotsmaterialvaluesandCTnumberlinearity.Measures:slicewidth,rampalignment,roddistances,lowcontrastdetectability,measuresuniformity,integralnon-uniformity,plotsintegralnon-uniformityprofile,contrast-to-noise,scoreslowcontrastobjects,measuresandplotsMTF.
Elekta503Catphan(XVI) MeasuresandplotsmaterialvaluesandCTnumberlinearity.Measures:slicewidth,rampalignment,roddistances,lowcontrastdetectability,measuresuniformity,integralnon-uniformity,plotsintegralnon-uniformityprofile,measuresandplotsMTF,uniformitymeandifference,lowcontrastvisibility.
SiemensImageQualityPhantom Geometricalmeasurements,centralareameanandstandarddeviation,uniformitymeasurements,measuresandplotsMTF,lowcontrasttargetscoring.
Catphan500/600 MeasuresandplotsmaterialvaluesandCTnumberlinearity.Measures:slicewidth,rampalignment,roddistances,lowcontrastdetectability,measuresuniformity,integralnon-uniformity,plotsintegralnon-uniformityprofile,contrast-to-noise,scoreslowcontrastobjects,measuresandplotsMTF.
Electron Density/Tissue Characterization Phantoms
CIRS062+062A(conebeam) Measuresandplots17densityareas.
Gammex467 Measuresandplots17densityareas.GeometricmeasurementinXandYdirection.
TomoCheese Measuresandplots20densityareas.
PTWEPIDQCPhantom(26cmx26cmtestareaatisocenter!–LARGEAREAtesting)
Mean,standarddeviation,andsignaltonoiseforeachofthe10coppersteps.Meanvalueforeachofthefourobjectsinthesixbrasssteps,horizontalandverticalspacingforgeometricaccuracy,MTFreportedandplottedforresolutionpattern,contrastisreportedforeachofthe27contrastobjects.
QC-3 Contrast,resolution
LasVegas Contrast
DR/CR/Fluoro kV Imaging Phantoms
•DISCPlus• IBAPrimusL•PTWNormi-4
Mean,standarddeviationandcontrastratioforeachstep,contrast-to-noiseratioforeachlowcontrastobject,uniformityandnoise,MTFreportedfortheresolutionpattern,geometricdistortionmeasurement.
LeedsTOR18FG Contrast,resolution
kV/MV Imager Coincidence Phantoms
CIRSISOCube kV/MVimagecoincidenceandpositioning,kVandMVradiation/lightfieldalignment,magnification,laserlocalization,CBCTalignment,tableheightaccuracy.
DICOMimageviewerandDICOMtagviewer
Severalmethodstolocateandimportyourimages DICOMdirectorybrowser,opendirectorybrowser,DICOMfilefilterfororganizingyourimages.
Batchprocessingofimages
Database AllmeasurementscanbetrackedandplottedovertimeintheRITtrend™database.Anynumberofdatabasescanbeused.AllStatisticalProcessControlparametersmeasuredandplotted.
MonitorImageQuality SMPTEpatternandTG18images
ManualMeasurements Distance,angle,profile,histograms,roundandsquareROI.ASCIIoutputofprofiles
OutputFormats Print,PDF,Excel(withcustomtemplates),XML
ImageTransfer BuiltinimageFTPfunction
Catp
han/O
BI, k
V/M
V &
Cone B
eam
Ele
ctr
on D
ensi
tyE
PID
QC
DR
/CR
/Flu
oro
kV
kV
/MV
Base
Module
s