16
I Contents MELSEC MEDOC – Start-up guide ........................................................ 1 Start MELSEC MEDOC 32-bit ..................................................................... 1 Start MELSEC MEDOC DOS ....................................................................... 1 Start options ................................................................................................... 2 Create a new project, Open a project .......................................................... 3 Programming ................................................................................................. 3 Transfer to the PLC, Transfer from the PLC ............................................. 4 Find the I/O, name or step .......................................................................... 4 Monitor mode (status display) .................................................................... 5 Monitor mode (status display) in the name list ........................................ 5 Set/Reset ......................................................................................................... 6 ONLINE-programming (modifying the program in RUN mode) ......... 7 Entry monitor in the instruction list or ladder diagram .......................... 8 Entry monitor in the Name Window ......................................................... 9 Copy to floppy disc ..................................................................................... 10 Copy from floppy disc to the hard drive ................................................. 10 Function keys ............................................................................................... 11 Alt-key functions ......................................................................................... 12 Shortcut keys (hot keys) ............................................................................. 12 Troubleshooting .......................................................................................... 13 MEDOC’s connection to the MELSEC PLC system ............................... 14

Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MEDOC-snabb.book Page I Tuesday, May 8, 2001 4:18 PM

Contents

MELSEC MEDOC – Start-up guide ........................................................1

Start MELSEC MEDOC 32-bit .....................................................................1Start MELSEC MEDOC DOS .......................................................................1Start options ...................................................................................................2Create a new project, Open a project ..........................................................3Programming .................................................................................................3Transfer to the PLC, Transfer from the PLC .............................................4Find the I/O, name or step ..........................................................................4Monitor mode (status display) ....................................................................5Monitor mode (status display) in the name list ........................................5Set/Reset .........................................................................................................6ONLINE-programming (modifying the program in RUN mode) .........7Entry monitor in the instruction list or ladder diagram ..........................8Entry monitor in the Name Window .........................................................9Copy to floppy disc .....................................................................................10Copy from floppy disc to the hard drive .................................................10Function keys ...............................................................................................11Alt-key functions .........................................................................................12Shortcut keys (hot keys) .............................................................................12Troubleshooting ..........................................................................................13MEDOC’s connection to the MELSEC PLC system ...............................14

I

Page 2: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

II

MEDOC-snabb.book Page II Tuesday, May 8, 2001 4:18 PM

Page 3: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

MEDOC-snabb.book Page 1 Tuesday, May 8, 2001 4:18 PM

MELSEC MEDOC – Start-up guide

Important!Read this before you install MELSEC MEDOC:

Copy protection: MELSEC MEDOC is not copy protected. In the licence contract it is described how to copy MELSEC MEDOC.

Licence contract: Enclosed you will find a contract, which is to be filled in and returned to Beijer Electronics.

Uninstallation: Remove all MELSEC MEDOC files from the hard diskby entering (if update version)

C:\>CD MEDOC [↵ ] - change directory to MELSEC MEDOC

ERASE MEDOC.* [↵ ] - remove MELSEC MEDOC files

ERASE *.TYP [↵ ] - remove type files

Installation: Insert the system disk to drive A and type:

A:INSTALL A: C:\MEDOC [↵ ] (DOS version)

A:SETUP [↵ ] (32-bit version)

MELSEC MEDOC installs in directory C:\MEDOC.

Start MELSEC MEDOC 32-bitStart MELSEC MEDOC from the Start-menu, Start - Programs - MELSEC MEDOC.

Start MELSEC MEDOC DOSStart by changing to the directory that MELSEC MEDOC is located in.

Example:

C:\CD MEDOC [↵ ]

Change to the directory MEDOC

Start MEDOC by entering:

MEDOC [↵ ]

1

Page 4: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

2

MEDOC-snabb.book Page 2 Tuesday, May 8, 2001 4:18 PM

Start optionsThe different start options affect the on-screen presentation and activate extended memory management.

Suitable start option for MELSEC MEDOC on PCs running Windows is

MEDOC E3.

Examples of other start options (MEDOC):

MEDOC H2 High resolution mode

MEDOC H3 High resolution mode + compressed ladder diagram

MEDOC E3 Activates extended memory management. Saves the PLC-program on the hard drive.

MEDOC ? Lists all the start options on-screen.

Page 5: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

MEDOC-snabb.book Page 3 Tuesday, May 8, 2001 4:18 PM

Create a new project Open a project

Programming

Start

New_Proj

Select PLC type

Name the project

Start

Open

Select the project

Edit

Name Instr Ladder

F2 – to the working area

F5 – insert

Enter – change

F6 – delete

F5 – exit insert

F2 – leave the working area

Save

F7 – exit ladder programming

F7 – start ladder programming

Enter – changing the I/O

F6 – delete the rung

3

Page 6: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

4

MEDOC-snabb.book Page 4 Tuesday, May 8, 2001 4:18 PM

Transfer to the PLC Transfer from the PLC

Find the I/O, name or step

Transfer

PLC

Medoc > PLC-answer the questions

Transfer

PLC

PLC > Medoc-answer the questions

Edit

Instr Ladder

Enter, Enter... – find, find next

Esc – cancel search when right position has been found

0 – find step zero

Edit, monitor, etc.

Enter I/O or name

F2 – to the working area

Page 7: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

MEDOC-snabb.book Page 5 Tuesday, May 8, 2001 4:18 PM

Monitor mode (status display)

Monitor mode (status display) in the name list

Edit

Instr Ladder

F8 – status display

F8 – exit status display

F2 – to the working area Find the I/O, name or step

Edit

Instr Ladder

Enter the device number

F8 – status display

Name

F8 – exit status display

5

Page 8: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

6

MEDOC-snabb.book Page 6 Tuesday, May 8, 2001 4:18 PM

Set/Reset

Note!The PLC-program is superordinate to the forced setting when the PLC is in RUN mode.

Edit

Instr Ladder

F8 – status display

F7 – Set/Reset

F2 – to the working area Enter the device number

Name

Enter the device number

1 – set to one (digital I/O)

0 – set to zero (digital I/O)

0-9 – change register content

F8 – exit status display

Esc – exit forced setting

The question regarding confirmation can be re-moved under Options/Security

Page 9: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

MEDOC-snabb.book Page 7 Tuesday, May 8, 2001 4:18 PM

ONLINE-programming (modifying the program in RUN mode)

Note!ONLINE-changes should only be used for minor adjustments such as changing the timer/ counter preset or supplementing individual instructions. The program in MEDOC and the PLC must be identical prior to change. The PLC-program may only include one END.

Edit

Instr Ladder

F3– highlight start line for modifi-cation

F2 – to the working area

F7 – modify or add by the highlighted rung

Alt+O – exit ONLINE

F7 – transfer changes to the PLC

F3– highlight final linefor the modifica-tion

Enter–modifications can take placein the area

Alt+O – ONLINE mode

Save

F2 – leave the working area

7

Page 10: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

8

MEDOC-snabb.book Page 8 Tuesday, May 8, 2001 4:18 PM

Entry monitor in the instruction list or ladder diagram

Note!Saved settings can be retrieved in the Name Window’s Entry monitor or in the Device monitor (F9 in the working area).

Alt+S – save settings

Alt+R – load saved settings

Edit

Instr Ladder

F8 – status display

F5 – enter I/O (total 16) to be monitored

F2 – to the working area

Arrow up and Arrow down change between page 1 and page 2

Find the I/O, name or step

F8 – exit status display

F5 – status display of the program and selected I/O

Ten different settings can be saved

Page 11: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

MEDOC-snabb.book Page 9 Tuesday, May 8, 2001 4:18 PM

Entry monitor in the Name Window

Alt+S – save settings

Alt+R – load saved settings

Edit

Instr Ladder

Enter I/O – e.g. X0

F7 – Select arbitrary I/OF9 – I/O above the cursor is copied

to the Entry monitor

Name

F8 – exit status display

F8 – status display

Ten different settings can be saved

9

Page 12: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

10

MEDOC-snabb.book Page 10 Tuesday, May 8, 2001 4:18 PM

Copy to floppy disc

Copy from floppy disc to the hard drive

Files

e.g. A:\Enter destination

Enter – carry out copying

State the name of the copy

Copy – select the project to be copied

Files

E.g. the directory you have noted. Directory selection (Dir_Set) can also take place using the function key F8. Exit by indicating a project in the directory.

Enter destination

Enter – carry out copying

State the name of the copy

Copy – select the project to be copied

Dir_Set

Dir_Set

A:\ – from the disk drive A

Note the current setting (shall be reset later)

Change to the directory where you have saved the copy. Directory selection (Dir_Set) can also take place using the function key F8. Exit by indicating a project in the directory.

Page 13: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

MEDOC-snabb.book Page 11 Tuesday, May 8, 2001 4:18 PM

Function keys

F1 Help: Show the help text for the current position.

F2 Jump between the menu area and the working area.

F3 Marking: Start/stop, used for example when moving an area.

F4 a) Block name: The block can be selected with “Move”, “Copy”and “Delete”b) Name: Display of names on/off.

F5 Insert row.

F6 Delete line or ladder rung.

F7 Start/stop programming of ladder rung.

F8 Monitoring on/off.

F9 Show further instructions when entering instructions.

F10 Copy previous row in the name field, special key in other functions.

Enter Activation of the selected function.

Esc Abort.

←→ Movement in the menu area + [Enter] for selectionF2: Working area ON/OFF

F4: Names ON/OFFF5: Insert (Instr/Name)F6: DeleteF7: Ladder editingF8: Status display + F7: Set/ResetEnter: Change of existing code or I/O

F1: Help

ESC: Abort

menu areastatus lineworking area

11

Page 14: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

12

MEDOC-snabb.book Page 12 Tuesday, May 8, 2001 4:18 PM

Alt-key functionsAlt+H Cursor in the working area – High resolution mode on/off

Alt+O Edit-Instr/Ladder. Cursor in the working area. – ONLINE programming mode.

Alt+C Edit-Instr/Ladder. Cursor in the working area. – Line comment reading (programming mode)

Alt+T Edit-Ladder. Cursor in the working area.

– Logic check of program from beginning to end and stop with: 1. No error: at the start of the last converted section. 2. With error: at the start of the converted section of the program where the error was discovered.

Shortcut keys (hot keys)Used to quickly move through the menus.

0 Open an existing project (Start Open)

1 Edit the instruction list (Edit Instr)

2 Edit the ladder diagram (Edit Ladder)

3 Edit the name list (Edit Name)

4 Edit parameters (Edit Param)

5 Transfer between MEDOC and the PLC system (Transfer PLC)

6 Transfer between MEDOC and other programming unit (Transfer GPP)

7 Printout (Print)

8 File management (Files)

9 Exit MEDOC (Quit Yes)

Page 15: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

MEDOC-snabb.book Page 13 Tuesday, May 8, 2001 4:18 PM

TroubleshootingReading of Error code when ERROR is lit on the PLC system

1. Start MELSEC MEDOC

2. Open the project

3. Select Edit

4. Select Instr or Ladder

5. Select Name and state the channel number for the error code registerFX-series Error codes: D8060-D8067

Program step: D8069 (if the error is linked to a specific instruction)

A-series Error codes D9008 (AnA/AnN also have D9091)Program step D9010 (if the error is linked to a specific

instruction)

6. Press F8 for status display of the register. Read the error code and pro-gram step.

7. Exit status display by pressing F8.

8. Correct the error.

13

Page 16: Contents MEDOC – Start-up guide FOR DOS.pdf · PLC must be identical prior to change. The PLC-program may only include one END. Edit Instr Ladder F3– highlight start line for

MELSEC MEDOC – Start-up guide

14

MEDOC-snabb.book Page 14 Tuesday, May 8, 2001 4:18 PM

MEDOC’s connection to the MELSEC PLC system

Converter SC09

Converter SC09

Converter SC09

The FX0S/FX0/FX0N/ The FX series The A seriesFX1S/FX1N/FX2N series