w w w . i t r o n . c o m
Electricity
Based on the successful ACE9000 Taurus ISP
meter, the ACE9000 Taurus IBS meter (Integrated
BS prepayment meter) is the latest single phase
keypad based, prepayment meter in a British
Standard (BS) housing.
The meter is suitable for new reticulation as well as
retrofitting of credit meters with BS footprints (e.g.
Ferraris meters). The ACE9000 Taurus IBS meter
is fully compliant to SABS 1524, IEC 62052-11, IEC
62053-21 and STS standards.
Benefits and Features The meter has a compact design for easy
installation and has a standard BS5685 footprint
for standardised mounting. Both symmetrical
(BS) and asymmetrical (DIN) wiring options are
supported.
All meters have a tamper detection switch. In the
event of tampering the meter can be programmed
(during manufacturing) either to automatically
disconnect the load or to log the tamper event while
allowing the load still to be connected.
The ACE9000 Taurus IBS meter is designed to
withstand extreme external conditions and is
manufactured to ISO9001 standards. The meter has
an IP54 rating (to be confirmed) and improved RF
immunity of 16V/m allowing it to be installed and
operated in harsh and humid environments.
For ease of use and user friendliness, all ACE9000
Taurus IBS meters include a LED rate indicator,
a status light showing status of the contactor,
indication of consumption, and a LCD.
The keypad when pressed has both tactile and
audible feedback. The acceptance or rejection of
a token is shown on the LCD. In addition the meter
stores and can display the last five tokens entered.
The Meter contains a sealable slot for retrofitting
Infopod.
The meter has a Utility Interrogation port via
auxiliary terminals located under the sealable
terminal cover.
Meter options
The ACE9000 Taurus IBS product range supports
the following options:
> Programmable audible low credit warning
threshold (in kWh)
> Maximum power limit setting (in W)
> Tamper switch operation: disconnection
or logging only
> Symmetrical (BS) or asymmetrical (DIN) wiring.
ACE9000 Taurus IBSIntegrated Single Phase Prepayment Electricity Meter
> ACE9000 Taurus IBS
- Maximum current of 80 A with Class
1 accuracy
- Standard BS Footprint for easy
mounting
- Symmetrical (BS) or asymmetrical
(DIN) terminal arrangement
- Tamper switch
- 20 Digit STS encryption
- Utility access port via auxiliary
terminals located under sealableterminal cover
- Sealable slot for retrofitting Infopod
8/17/2019 Meter Itron
2/2
> Dimensions
> Connection Diagrams
Itron House
Tygerberg Office Park
Hendrik Verwoerd Drive
7500 PlattekloofSouth Africa
www.itron.com
© Copyright 2009, Itron. All Rights Reserved. - Itron reserves the right to change these specifications without prior notice.
Technical Specifications
Standards SABS 1524-1 MC 195
SABS IEC 1036 as referenced in SABS 1524-1
SCSSCAAA9 (MC171) SCSSCAAJ1
TRMSCAAP2 RES/RR/00/11740
ESKASAAN2
NRS: 009-4-2; 009-6-6; 009-6-7; 009-6-9; 009-7
Rated voltage 230V (-20% + 15%)
Frequency 50Hz +/- 5Hz
Accuracy Class 2 (Class 1 optional)Basic current (lb) 10A or 20A
Maximum current (lmax) 60A or 80A
Starting current 20mA
Operating voltage range Maximum: 265V
Minimum: 184V
Maximum withstand voltage (48hr) 415V
RF immunity 16V/m
Power consumption Asymmetrical (DIN)
L
N *
1 3 4 6
> Symmetrical (BS)
1 3 4 6
L
N
*
About Itron Inc.
Itron Inc. is a leading technology provider to the global energy and water industries. Our company is the world’s leading
provider of metering, data collection and utility software solutions, with nearly 8,000 utilities worldwide relying on
our technology to optimize the delivery and use of energy and water. Our products include electricity, gas and water
meters, data collection and communication systems, including automated meter reading (AMR) and advanced metering
infrastructure (AMI); meter data management and related software applications; as well as project management,
installation, and consulting services. To know more, start here: www.itron.com
EL.0032-EN-10.09