1 272 CasoLine MF CasoLine MF concealed grid MF suspended ceiling system is a monolithic suspended ceiling system suitable for most internal dry lining applications. It is used in all types of commercial and industrial buildings, including institutional use areas such as schools and hospitals. The system comprises a concealed metal framework suspended from the structural soffit using strap hangers or angle section. Gypframe Acoustic Hangers can be used to suspend the grid from timber joists to maximise the degree of acoustic isolation. Gyproc boards are screw-fixed to the framework to form a ceiling lining with a seamless surface. CasoLine MF provides a robust suspended ceiling able to accept a degree of loading. The plenum is used to route ducting and other services and can be accessed by providing Gyproc Profilex access panels. Ventilation openings and other services can also be accommodated. Curved ceilings can be easily achieved using preformed Gypframe MF7 support components. Gypframe MF7 Primary Support Channel Gypframe MF5 Ceiling Section Gypframe MF9 Connecting Clip Gypframe MF6 Perimeter Channel 1 2 3 4 6.2 Choice of framing sizes to suit range of performance requirements Monolithic appearance Suspension from concrete or timber floors Acoustic hangers provide option of resilient suspension Durable ceiling lining Ventilation ducts and other services can be accommodated in plenum Access panels provide services access Easy to create bulkheads and change levels Key facts 2 3 4 Sector Guide Offices Retail Education Industrial Custodial Residential - Housing Residential - High Rise Commercial Sport & Leisure Healthcare Auditoria Entertainment Residential - Apartments CasoLine MF Concealed grid MF suspended ceiling system

MF CasoLine MF - Gyproc 6.2 - CasoLine MF.pdf · CasoLine MF CasoLine MF concealed grid MF suspended ceiling system is a monolithic suspended ceiling system suitable for most internal

  • Upload
    others

  • View
    21

  • Download
    0

Embed Size (px)

Citation preview

  • 1

    272

    CasoLine MF

    CasoLine MF concealed grid MF suspended ceiling system is

    a monolithic suspended ceiling system suitable for most

    internal dry lining applications. It is used in all types of

    commercial and industrial buildings, including institutional

    use areas such as schools and hospitals.

    The system comprises a concealed metal framework

    suspended from the structural soffit using strap hangers or

    angle section. Gypframe Acoustic Hangers can be used to

    suspend the grid from timber joists to maximise the degree

    of acoustic isolation. Gyproc boards are screw-fixed to the

    framework to form a ceiling lining with a seamless surface.

    CasoLine MF provides a robust suspended ceiling able to

    accept a degree of loading. The plenum is used to route

    ducting and other services and can be accessed by

    providing Gyproc Profilex access panels. Ventilation

    openings and other services can also be accommodated.

    Curved ceilings can be easily achieved using preformed

    Gypframe MF7 support components.

    Gypframe MF7 Primary Support Channel

    Gypframe MF5 Ceiling Section

    Gypframe MF9 Connecting Clip

    Gypframe MF6 Perimeter Channel

    1

    2

    3

    4

    6.2

    ● Choice of framing sizes to suit range of

    performance requirements

    ● Monolithic appearance

    ● Suspension from concrete or timber floors

    ● Acoustic hangers provide option of

    resilient suspension

    ● Durable ceiling lining

    ● Ventilation ducts and other services can be

    accommodated in plenum

    ● Access panels provide services access

    ● Easy to create bulkheads and change levels

    Key facts

    2

    3

    4

    Sector Guide

    Off

    ices

    Ret

    ail

    Edu

    cati

    on

    Ind

    ust

    rial

    Cu

    sto

    dia

    l

    Res

    iden

    tial

    -H

    ou

    sin

    g

    Res

    iden

    tial

    -

    Hig

    h R

    ise

    ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔✔

    Co

    mm

    erci

    al

    Spo

    rt &

    Lei

    sure

    Hea

    lth

    care

    Au

    dit

    ori

    a

    Ente

    rtai

    nm

    ent

    Res

    iden

    tial

    -A

    par

    tmen

    ts

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:37 Page 272

  • 273

    T 00353 1 629 8400 F 00353 1 623 7054 E [email protected]

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    Gyproc board products

    Gyproc WallBoard1, 2

    Thickness 9.5, 12.5, 15mm

    Width 900, 1200mm

    Gyproc SoundBloc1

    Thickness 12.5, 15mm

    Width 1200mm

    Gyproc FireLine1, 2

    Thickness 12.5, 15mm

    Width 1200mm

    Glasroc F MultiBoard

    Thickness 6, 10, 12.5mm

    Width 1200mm

    1 Moisture resistant boards are specifed in intermittent wet useareas e.g. shower areas, bathrooms and kitchens.2 Also available in DUPLEX grades where vapour control is required.pour check is required.

    Ceiling products

    Gyptone board products

    and

    Rigitone board products

    Gypframe metal products

    Gypframe MF5 Ceiling Section

    Main support section.

    Prime dimensions 80 x 26mm

    Gypframe MF6 Perimeter Channel

    Perimeter support for MF5s.

    Prime dimensions 20 x 28 x 30mm

    Gypframe MF7 Primary Support Channel

    Primary support for MF5s.

    Prime dimensions 15 x 45mm

    Gypframe MF8 Strap Hanger

    Suspension of ceiling grid.

    Prime dimension 25mm

    Gypframe GA1 Steel Angle

    Width 25 x 25mm

    Gypframe GAH1 Acoustic Hanger

    Length 35mm

    Gypframe GAH2 Acoustic Hanger

    Length 70mm

    Gypframe MF11 Nut and Bolt

    Joining hanger to soffit cleat.

    Dimensions 6 x 12mm bolt

    Gypframe MF12 Soffit Cleat

    Suspension point from structural soffit.

    Prime dimensions 27 x 37 x 25mm

    Gypframe MF9 Connecting Clip

    Fixing MF5s to MF7.

    Fixing and finishing products

    Gyproc Profilex Access Panels

    For access to the plenum for

    maintenance purposes.

    Gyproc Drywall Screws

    For fixing boards to framing up to

    0.79mm thick.

    Gyproc Wafer Head Drywall Screws

    For metal-to-metal fixing up to 0.79mm thick.

    Gyproc Wafer Head Jack-Point Screws

    For metal-to-metal fixing 0.8mm thick

    or greater.

    COMPONENTS

    OR

    OR

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:37 Page 273

  • 274

    www.gyproc.ie

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    Gyproc Sealant

    For sealing air paths to achieve optimum

    sound insulation.

    Gyproc Skimcoat, Gyproc Carlite Finish or

    Gyproc Board Finish

    To provide a plaster skim finish.

    Isover Modular Roll

    For providing acoustic / thermal insulation.

    Stone Mineral Wool

    For providing fire performance.

    Gyproc jointing materials

    For seamless jointing.

    Health and SafetySafety Data Sheets for all Gypsum Industries’ products

    are available to download from our website

    www.gypsum.ie, or via our Technical Sales Department.

    COMPONENTS

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:37 Page 274

  • 275

    T 00353 1 629 8400 F 00353 1 623 7054 E [email protected]

    Suspension from concrete soffitGypframe MF6 Perimeter Channel is fixed to the wall at

    maximum 600mm centres, and Gypframe MF12 Soffit Cleats

    secured to the soffit at 1200mm centres, using appropriate

    fixings. Gypframe MF8 Strap Hanger or Gypframe GA1 Steel

    Angles are pre-cut and secured to the soffit cleats with

    Gypframe MF11 Nut and Bolt. Alternatively, the GA1 angles

    can be fixed directly to the Soffit (see figure 10).

    Gypframe MF7 Primary Support Channels are installed over

    the Gypframe MF6 Perimeter Channels and secured to the

    hangers. Gypframe MF5 Ceiling Sections are run at right

    angles to the underside of primary channels to form the

    secondary grid. The ceiling sections are secured to the

    primary channels by Gypframe MF9 Connecting Clips.

    Boards are fixed to the secondary grid to form single or

    multi-layer linings as specified.

    Suspension from timber joistsThe procedure is as for concrete except that soffit cleats are

    not required – hangers are twice fixed directly to the side

    of the joists.

    Board fixingsBoard fixings for Gyproc, Glasroc F and Rigitone boards

    should be at 150mm centres at perimeters, 230mm centres

    within the field of the board.

    Board fixings for Gyptone boards should be at 230mm

    centres across perimeters and through the field of the board.

    INSTALLATION

    A special procedure is used for framing, fixing and

    jointing Rigitone and Gyptone boards. Detailed installation

    notes are given in the Installation Guide.

    For full installation details, refer to the Installation Guide at www.gypsum.ie

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:37 Page 275

  • 276

    www.gyproc.ie

    PERFORMANCE

    Table 3 Dimensions, weights, and performance

    Fire protection to steel beams1 supporting concrete floors

    Ceiling boards Approx. MF5 MF7 Fire Performanceweight support support resistance2 substantiation

    centres centres reportkg/m2 mm mm mins

    ..............................................................................................................................................................................................................................................Two layers of 12.5mm Gyproc WallBoard 21 450 1200 30 C100013..........................................................................................................................................................................................................One layer of 12.5mm Gyproc FireLine 14 450 1200 60 C100014

    One layer of 12.5mm Gyproc MultiBoard 12 600 1200 60 G100036..........................................................................................................................................................................................................Two layers of 10mm Gyproc MultiBoard 20 400 1200 120 G100038

    Two layers of 15mm Gyproc FireLine 28 450 900 120 C100015..............................................................................................................................................................................................................................................1 Concrete floors as described in BS 476: Part 23: 1987. The steel beams subjected to test had a section factor A/V (Hp/A) of 205m-1 calculated onthe basis of three sided profiled exposure. The suspended ceiling will also provide adequate protection to steel beams with a lower sectionfactor. For beams with a higher section factor, contact the Technical Sales Department for guidance.

    2 Board joints must be reinforced with Gyproc Paper Joint Tape for the quoted fire resistance periods to be achieved. Please refer to sectionfor full details.

    In the following tables the fire resistance and sound insulation performances are based on imperforate constructions using

    boards with all joints taped and filled according to Gypsum Industries’ recommendations. Isover insulation may be laid

    over the back of the ceiling grid, and does not detract from the fire performance of the floors. The quoted performances

    are achieved only if Gypsum Industries’ components are used throughout, and the Company’s fixing recommendations are

    strictly observed.

    Fire protection - timber floor construction

    Ceiling boards Approx. Floor MF5 MF7 Fire Performanceweight type1 support support resistance2 substantiation

    centres centres reportkg/m2 mm mm mins

    ..............................................................................................................................................................................................................................................One layer of 12.5mm Gyproc FireLine 14 a 450 1200 30 C106001

    Two layers of 12.5mm Gyproc WallBoard 21 a 450 1200 30 C106002.........................................................................................................................................................................................................

    Two layers of 12.5mm Gyproc FireLine 24 a 450 1200 60 C106003.........................................................................................................................................................................................................

    Two layers of 15mm Gyproc FireLine 28 a 450 900 90 C106004.........................................................................................................................................................................................................

    Three layers of 10mm Gyproc MultiBoard 30 c 450 1200 120 G106035..............................................................................................................................................................................................................................................1 Floor types

    a Timber joist floors incorporating any structurally suitable wood board flooring on timber joists not less than 38mm wide at 600mm centres.

    b 21mm minimum t & g wood board flooring on timber joists not less than 44mm wide at 600mm centres.c 21mm minimum t & g wood board flooring on timber joists not less than 38mm wide at 600mm centres.

    2 Board joints must be reinforced with Gyproc Paper Joint Tape for the quoted fire resistance periods to be achieved. Please refer to sectionfor full details.

    Table 4 Dimensions, weights, and performance

    2.2

    2.2

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:37 Page 276

  • 277

    T 00353 1 629 8400 F 00353 1 623 7054 E [email protected]

    Table 5 Dimensions, weights, and performance

    Fire protection to floor or roof cavity above suspended ceiling1

    Ceiling boards Approx. Insulation Fire resistance2 Performanceweight integrity : insulation substantiationkg/m2 minutes report

    ..............................................................................................................................................................................................................................................Two layers of 22 100mm Isover 30 : 30 C10604512.5mm Gyproc WallBoard Modular Roll

    laid over grid

    .......................................................................................................................................................................................................

    Two layers of 28 30mm rock mineral wool 60 : 60 C10605115mm Gyproc FireLine slab (45 kg/m3) laid over grid

    ..............................................................................................................................................................................................................................................1 Normal fixing centres for Gypframe MF5s and MF7s (450 and 1200mm respectively).2 Board joints must be reinforced with Gyproc Paper Joint Tape for the quoted fire resistance periods to be achieved. Please refer to sectionfor full details.

    1 2

    Table 6 Dimensions, weights, and performance

    Detail Ceiling boards Approx. Laboratory sound insulation Performanceweight (100 - 3150Hz) substantiation

    Airborne Impact reportkg/m2 Rw dB LnW dB

    ..............................................................................................................................................................................................................................................

    One layer of 12.5mm Gyproc WallBoard 12 56 68 C100016

    Two layers of 12.5mm Gyproc WallBoard 22 58 66 C100017

    One layer of 12.5mm Gyproc SoundBloc 13 61 60 C100018

    Two layers of 12.5mm Gyproc SoundBloc 24 64 57 C100019..............................................................................................................................................................................................................................................1 Basic floor construction is lightweight concrete joist floor with concrete infill panel (surface density of infill is 90kg/m3) and total depth150mm. sound insulation is Rw 35dB (airborne) and LnW 91dB (impact).2 Normal fixing centres for Gypframe MF5s and MF7s (450 and 1200mm respectively).

    Upgrading of the sound insulation of concrete floors1

    CasoLine MF ceiling2

    hung underneath basic floorto give 240mm cavity

    CasoLine MF ceiling2

    hung underneath basic floorto give 240mm cavity, with 80mm

    Isover Modular Roll in cavity

    1

    1

    2

    2

    6.2

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:37 Page 277

  • 278

    www.gyproc.ie

    Sound insulation to timber floors1

    195mm x 45mm timber joists at CasoLine MF ceiling hung600mm centres with 18mm t and g underneath 195mm x 45mm wood chipboard flooring and timber joists at 600mm centres basic ceiling3. to give a 277mm cavity.

    80mm Isover Modular Roll laid on ceiling boards. Floating floor2.

    CasoLine MF ceiling CasoLine MF ceiling CasoLine MF ceiling CasoLine MF ceilinghung underneath basic floor hung underneath basic floor hung underneath basic floor hung underneath basic floor

    to give 150mm cavity. (ceiling removed) to (ceiling removed) with a (ceiling removed) using 80mm Isover Modular Roll give 277mm cavity. layer of Gyproc Plank fixed to Gypframe Acoustic Hangers

    laid on ceiling boards. 80mm Isover Modular Roll the underside of the chipboard to give a 277mm cavity.laid on ceiling boards. to give a 258mm cavity. 80mm Isover Modular Roll

    80mm Isover Modular Roll laid on ceiling boards.laid on ceiling boards.

    Detail Ceiling boards3 Approx. Floor Fire Laboratory sound insulation Performanceweight depth resistance4 (100 - 3150Hz) substantiation

    Airborne Impact reportkg/m2 mm Rw dB LnW dB

    ..............................................................................................................................................................................................................................................One layer of 12.5mm Gyproc Plasterboard 11 226 38 79 C106028

    Two layers of 12.5mm Gyproc SoundBloc 24 376 30 66 50 C106011

    One layer of 12.5mm Gyproc SoundBloc 13 389 30 58 66 C106005

    Two layers of 12.5mm Gyproc SoundBloc 24 402 30 61 60 C106006

    Two layers of 12.5mm Gyproc SoundBloc 24 320 30 60 60 C106007

    One layer of 12.5mm Gyproc SoundBloc 13 307 30 59 62 C106008

    Two layers of 12.5mm Gyproc SoundBloc 24 320 30 63 57 C106009

    Two layers of 12.5mm Gyproc SoundBloc 24 320 30 63 54 C106013

    Two layers of 15mm Gyproc SoundBloc 27 381 60 66 54 C106025

    Two layers of 12.5mm Gyproc FireLine 24 320 60 59 61 C106003

    Two layers of 15mm Gyproc SoundBloc 28 325 60 60 60 C106014

    Two layers of 12.5mm Gyproc FireLine 21 320 60 62 55 C106022

    Two layers of 15mm Gyproc SoundBloc 27 325 60 63 54 C106023

    Two layers of 15mm Gyproc FireLine 28 325 90 59 61 C106004

    Two layers of 15mm Gyproc FireLine 25 325 90 62 55 C106024..............................................................................................................................................................................................................................................1 Normal fixing centres for MF5s and MF7s (450 and 1200mm respectively).2 18mm t & g wood chipboard spot bonded to Gyproc Plank on Isover Sound Deadening Floor Slabs laid on 12mm plywood.3 If the basic ceiling comprises of lath & plaster it should be supported by chicken wire, securely nailed to the joists.4 Board joints must be reinforced with Gyproc Paper Joint Tape for the quoted fire resistance periods to be achieved. Please refer to sectionfor full details.

    Table 7 Dimensions, weights, and performance

    1

    3 54

    New floating floorBasic floor

    2

    Upgrading

    6

    1

    2.2

    3

    3

    5

    5

    6

    4

    4

    4

    4

    2

    6

    6

    6

    2

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:37 Page 278

  • 279

    T 00353 1 629 8400 F 00353 1 623 7054 E [email protected]

    GypWall / CasoLine MF ceiling

    Suspended ceiling construction

    Double layer Single layer Double layer Single layer12.5mm Gyproc 12.5mm Gyproc 12.5mm Gyproc 12.5mm GyprocSoundBloc. SoundBloc. SoundBloc. SoundBloc.80mm Isover 80mm IsoverModular Roll Modular Rollon back. on back.

    Partition construction Weighted standardised level difference (DnTw)and performance substantiation report number.

    ..............................................................................................................................................................................................................................................146mm Gypframe metal studs at 600mm centres. 51 50 50 4825mm Isover Acoustic Roll in cavity. C10J001 C10J002 C10J003 C10J004One layer of Gyproc Plank and one layer of 12.5mm Gyproc SoundBloc each side.

    146mm Gypframe metal studs at 600mm centres. 49 48 48 4525mm Isover Acoustic Roll in cavity. C10J005 C10J006 C10J007 C10J008Two layers of 12.5mm Gyproc SoundBloc each side.

    70mm Gypframe metal studs at 600mm centres. 45 45 44 4525mm Isover Acoustic Roll in cavity. C10J009 C10J010 C10J011 C10J012Two layers of 12.5mm Gyproc SoundBloc each side...............................................................................................................................................................................................................................................Refer to section 3.2 GypWall for partition performance data based on laboratory tests.

    Table 8 Sound insulation of composite constructions

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:37 Page 279

  • DESIGN

    Refer to section 6.1 Introduction, for general considerations.

    Cavity barriersWhere cavity barriers are required, these can be formedusing Gyproc FireLine (limited combustability) or Glasroc FMultiBoard (non-combustible) screw-fixed to a simplemetal or timber frame. The framing should be fixed to thestructure to avoid undue loading of the ceiling suspensiongrid or, alternatively, additional hangers should beincorporated to support the ceiling alongside the cavitybarrier. Refer to section 6.7 Cavity barriers.

    Ceiling lift Recent and proposed changes to Building RegulationsTechnical Guidance Document L, Conservation of Fuel andEnergy - Dwellings, with regard to the levels of air tightnessrequired within dwellings, may lead to differential airpressure in separate areas within a building. The ceiling isnormally the lightest fixed element in the room, and istherefore most likely to be affected by this change inpressure, particularly if a door or window is opened.

    This can cause the ceiling to lift slightly, which may create anoise. Whilst this noise can be annoying to the occupier, ithas no detrimental effect on the performance of the ceiling.

    The designer should consider incorporating a pressure releasesystem to minimise the risk of ceiling lift in rooms with nopermanent ventilation. Vents in the walls, doors or ceilingsmight be suitable. Where sufficient 'pressure relief' cannot bedesigned in, it is recommended that the Gypframe MF5Ceiling Section and the Gypframe MF7 Primary SupportChannel should be screw-fixed together using two GyprocWafer Head Jack-Point Screws at each intersection,particularly where non-perforated board linings are specified.

    Suspension – Gyproc and Gyptone linings Fixing points for suspending the metal grid are required at1200mm centres in each direction. Suitable fixing devices,e.g. Rawl Hammer In Fixing, should be employed whenfixing to the structure. These should be non-combustible,e.g. Rawl Rawlok Sleeve Anchor, when the ceiling isrequired to provide fire protection. The ceiling grid can besuspended from a concrete soffit using Gypframe MF12Soffit Cleats and Gypframe MF8 Strap Hanger, oralternatively, Gypframe GA1 Steel Angle. The latter providesa more robust suspension support which restricts any flexingof the lining when pressure is applied from below.Gypframe GA1 Steel Angle is thus the preferred suspensionoption when a plaster finish is specified to Gyproc boards.

    If Gypframe GA1 Steel Angle is used it can, if preferred, befixed directly to the soffit rather than via MF12 Soffit Cleats.The angle is cut and bent to fit as shown in Fig 10. Forsingle layer boarding, where GA1 Steel Angle is fixed direct,the MF7 Primary Support Channel and GA1 Steel Angles arefixed at 1200mm centres. For typical double layer ceilingsthe GA1 Steel Angles are fixed at max. 1200mm centres,but the MF7s are closed down to 900mm max. centres.

    280

    www.gyproc.ie

    EnvironmentalCasoLine MF is unsuitable for use in areas subject to

    continuously damp or humid conditions.

    Plasterboards are not suitable for use in temperatures

    above 49ºC but can be subjected to freezing conditions

    without risk of damage.

    Fire protectionFor reaction to fire classifications for Gyproc and Glasrocboards please refer to Section .

    Fire resistanceThe fire resistances quoted are for imperforate ceilingstested to BS 476: Part 8: 1972, or BS 476: Parts 21 and 22:1987, or Part 23: 1987, or assessments based on these tests.

    Sound insulationThe airborne and impact sound ratings quoted are forimperforate ceilings and have been tested in accordancewith BS EN ISO 140-3: 1995, and rated in accordance withBS EN ISO 717-1: 1997. The tests on ceiling/partitioncombinations in Table 8 were treated as site tests.

    Airtightness is essential for optimum sound insulation. While most junctions will be sealed with standard jointingmaterials, gaps at the perimeter of the floor and ceiling,and other small airpaths, can be sealed using GyprocSealant. The sound insulation data quoted was measured inthe absence of flanking transmission. The performanceof the floor in practice will generally be governed byflanking transmission.

    Gyptone and Rigitone boards are perforated and aredesigned to provide acoustic correction. Where soundinsulation room to room is required, sound attenuation(Dncw) of 39dB can be achieved with the inclusion of 100mmIsover Modular Roll over the back of the ceiling.Alternatively, other design considerations should beadopted such as extending adjoining partitions into theplenum void or installing a plenum barrier.

    Sound absorptionGyptone and Rigitone boards provide sound absorptionwhen used in conjunction with an air space behind theceiling. Tests have been carried out to BS EN 20354: 1993and ISO 354: 1985. Increased levels of sound absorption canbe achieved by including insulation over the back of theceiling. For full details regarding the performance of theGyproc Ceilings Range, please refer to our Ceilings Guide.

    Water vapour controlWhere there is a requirement for a vapour control layer,Duplex grade boards should be specified as the face layer(i.e. the second layer in double layer linings). Theapplication of two coats of Gyproc Drywall Sealer to theface lining will also provide vapour control.

    Thermal propertiesIsover insulation can be laid over the suspension grid toprovide the required standard of thermal insulation.

    2.1

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:37 Page 280

  • 281

    T 00353 1 629 8400 F 00353 1 623 7054 E [email protected]

    Gypframe Acoustic Hangers can be used to suspend thegrid from timber joists to maximise the degree of acousticisolation (see Fig 12). In a comparative test a 3dBimprovement in airborne sound insulation and a 6dBimprovement in impact sound insulation were achieved.Refer to Table 7, Constructions 4 and 6 , relating todouble layer Gyproc SoundBloc linings.

    With concrete floors the high mass of the constructionmeans that high levels of acoustic performance can beachieved when the CasoLine MF ceiling is suspended byconventional means i.e. strap hangers or angle section.

    Suspension – Rigitone linings The Gypframe MF7 Primary Support Channels are fixed at1000mm centres. Suspension points to the structure for theMF7’s are required at 900mm centres. Suitable Rawl fixingdevices should be employed when fixing to the structure.The ceiling grid can be suspended from a concrete soffitusing Gypframe MF12 Soffit Cleats and Gypframe MF8Strap Hanger, or alternatively, Gypframe GA1 Steel Angle.

    Suspension of CasoLine MF from engineered I joistsPlease contact the joist manufacturer for advice.

    Partition to suspended ceiling junctionTests on lightweight constructions have revealed thefollowing:–

    1. In situations where a GypWall metal stud partition, whichmust be securely fixed to the structure, penetrates CasoLineMF, the structural performance of the partition can be basedon the floor to suspended ceiling height irrespective of theconstruction. Therefore, lightweight partitions which arerequired for space division in tall storey heights will besignificantly strengthened by the ceiling system. WhereCasoLine MF is installed on one side of the partition, only aslight loss of flexural strength will occur when any loading isapplied on the ceiling side of the partition.

    2. The structural performance of a GypWall metal studpartition fixed to the framework of a CasoLine MF ceiling,or to noggings cut from Gypframe MF5 Ceiling Section setat 600mm centres, is equal to the performance of a metalstud partition of the same height fixed direct to thestructural soffit.

    Imposed loadsTables 9, 10 and 11 provide loading data for the suspensiongrid for Gyproc, Gyptone and Rigitone boards respectively,based on a limiting deflection factor of L/400.

    Table 9 Maximum recommended loads on

    CasoLine MF grid1 with Gyproc linings

    Suspension point MF7 Maximum load including

    centres channel weight of board and insulation*

    centres

    mm mm kg/m2

    ....................................................................................................................

    1200 1200 30

    1200 900 40

    1200 600 60

    900 1200 35

    ....................................................................................................................1 MF5 Ceiling Sections spaced at 450mm centres (maximum).

    Table 10 Maximum recommended loads on

    CasoLine MF grid with Gyptone linings

    Suspension MF7 Maximum load including point channel board and any insulation.*centres centres MF5s at 600mm centres mm mm kg/m2

    ....................................................................................................................1200 1200 251200 900 351200 600 55....................................................................................................................

    Table 11 Maximum recommended loads on

    CasoLine MF grid with Rigitone linings

    Suspension MF7 Maximum load including point channel board and any insulation.*centres centres MF5s at nominal 330mm centresmm mm kg/m2

    ....................................................................................................................900 1000 30....................................................................................................................

    * Maximum loads should be reduced by 25% if GypframeGA1 Steel Angles are fixed directly to the soffit.

    ServicesThe plenum can be used to route all service requirementsincluding ducting, pipework, electrical cables and conduit.Where lighting fittings, Gyproc Profilex access panels andsimilar components are incorporated as part of the designrequirements, consideration must be given to maintainingthe integrity of the ceiling to meet fire resistance andsound insulation requirements. Where Gyproc access panelsare required they can be installed as shown in Fig 4. Refer to section 8.4 - Gyproc Profilex Access Panels.

    The installation of services should be in accordance with allavailable standards, guidelines and recommendations.

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:37 Page 281

  • 282

    www.gyproc.ie

    Fixtures / Fixings

    Fixings to the system should always be made into the metalgrid or to supplementary framing. Some adjustment of theprimary grid may be required to support particularly heavyloads, see Tables 9, 10 and 11. Where loads outside thisrange are anticipated, independent suspension should beprovided from the structure.

    Control jointsGyproc Control Joints may be required in the ceiling torelieve stresses induced by expansion and contraction of thestructure. The location of the control joints is at thediscretion of the specifier. It is recommended that theycoincide with movement joints within thesurrounding structure.

    Rigitone expansion jointsRigitone boards should be cut 10mm short of the perimeterwall and should not be fixed to the perimeter channel, seeFigs 7 and 8. Expansion joints should be included in theceiling, one 10mm expansion joint should be included every10m of ceiling in each direction, and where there is anexpansion joint within the surrounding structure.

    FinishingRefer to section 1.5 Finishing Coat Plasters, section 2.2Jointing, and section 2.5 Decorative effects.

    Additional care and attention should be exercised whenjointing Gyptone and Rigitone boards so as not to fill theperforations and impair the acoustic performance ofthe finished ceiling.

    Estimating – Gyproc / Gyptone liningsThe estimated construction time is 1.5m2 / man hour (singlelayer ceiling) or 1m2 / hour (double layer ceiling) readyfor finishing.

    Estimating – Rigitone liningsThe estimated construction time is 0.75m2 / man hour readyfor decoration.

    CONSTRUCTION DETAILS

    Fig 1 Typical layout for plasterboard

    1200mm

    1200mm150mm

    maximumcentres

    230mmmaximum

    centres

    450mm

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:37 Page 282

  • 283

    T 00353 1 629 8400 F 00353 1 623 7054 E [email protected]

    Fig 2 Typical layout for Gyptone board (LINE 6 – 2400 x 1200mm board illustrated)

    1200mm

    1200mm

    600mm

    CONSTRUCTION DETAILS CONT’D

    Fig 3 Typical layout for Rigitone board

    1000mm max. 1000mm 1000mm

    A A

    B

    B

    900m

    m90

    0mm

    330

    no

    m33

    0n

    om

    330

    no

    m33

    0n

    om

    330

    no

    m33

    0n

    om

    150

    max

    .

    See Fig 7

    See Fig 8

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:38 Page 283

  • 284

    www.gyproc.ie

    Fig 5 Perimeter arrangement – Gypframe MF5Ceiling Section

    Fig 6 Perimeter arrangement – Gypframe MF7Primary Support Channel

    Fig 4 Gyproc Profilex access panel installation

    Fig 7 Perimeter arrangement – Rigitone boards Fig 8 Perimeter arrangement – Rigitone boards

    1000mmmax.

    150mmSection AA of Figure 3.

    Section BB of Figure 3.

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:38 Page 284

  • 285

    T 00353 1 629 8400 F 00353 1 623 7054 E [email protected]

    Fig 11 Bulkhead

    Fig 13 Change of level

    Fig 12 Suspension from timber joists usingGypframe Acoustic Hangers

    Fig 10 Pre-forming Gypframe GA1 Steel Angle fordirect fixing to the structure. Note: Please refer toTables 11 to 13.

    Fig 9 Clip fixing of Gypframe MF5 Ceiling Section.Note: Please refer to DESIGN: Imposed loads on p15.

    MF12

    MF8

    MF7

    MF9

    MF5

    Gypframe Acoustic Hanger

    MF11

    35m

    m

    M6nut/bolt/washers

    (by others)

    6.2

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:39 Page 285

  • 286

    www.gyproc.ie

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    Geometric design, perforated boards with a special sound

    absorbent tissue backing, provide a jointless finish that is

    ready for on-site decoration. All Gyptone boards are capable

    of giving sound insulation performance up to Dncw = 39dB.

    LINE 6

    Edge Nominal Weightprofile size mm kg/m2

    Tapered 2400 x 1200 x 12.5 8

    LINE 7 BASE

    Curve Curve

    Edge Nominal Weightprofile size mm kg/m2

    Tapered 2400 x 900 x 6.5 5 (LINE 7)

    6 (BASE)

    QUATTRO 41

    Edge Nominal Weightprofile size mm kg/m2

    Tapered 2400 x 1200 x 12.5 8

    QUATTRO 46

    Edge Nominal Weightprofile size mm kg/m2

    Tapered 2400 x 1200 x 12.5 8

    QUATTRO 47

    Edge Nominal Weightprofile size mm kg/m2

    Tapered 2400 x 1200 x 12.5 8

    GYPTONE BOARDS

    ACOUSTIC PERFORMING CEILING BOARDS AVAILABLE FOR THE CASOLINE MF SYSTEM

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:41 Page 286

  • 287

    T 00353 1 629 8400 F 00353 1 623 7054 E [email protected]

    Caso

    Lin

    e M

    FC

    on

    ceal

    ed g

    rid

    MF

    susp

    end

    ed c

    eilin

    g s

    yste

    m

    6.2

    RIGITONE

    8 / 18

    Edge Nominal Weightprofile size mm kg/m2

    Square 1998 x 1188 x 12.5 10

    10 / 23

    Edge Nominal Weightprofile size mm kg/m2

    Square 2001 x 1196 x 12.5 10

    15 / 30

    Edge Nominal Weightprofile size mm kg/m2

    Square 2010 x 1200 x 12.5 9.5

    Gypsum boards perforated with regular or random patterns with sound absorbent tissue backing. Provides a monolithic

    appearance ready for on-site decoration. Boards can be dry curved to a minimum radius of 5000mm.

    12 - 20 / 66

    Edge Nominal Weightprofile size mm kg/m2

    Square 1980 x 1188 x 12.5 9.5

    8 - 15 - 20

    Edge Nominal Weightprofile size mm kg/m2

    Square 2000 x 1200 x 12.5 10

    8 - 15 - 20 SUPER

    Edge Nominal Weightprofile size mm kg/m2

    Square 1960 x 1200 x 12.5 10

    ACOUSTIC PERFORMING CEILING BOARDS AVAILABLE FOR THE CASOLINE MF SYSTEM CONT’D

    book 6_jan10a:c01 Introduction v3.qxd 15/04/2010 19:42 Page 287

    /ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False

    /CreateJDFFile false /Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure false /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles false /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /DocumentCMYK /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /UseDocumentProfile /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice