10
MICE COLLABORATION MEETING CERN March 29-April 1, 2004 MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova P. Fabbricatore INFN-Genova Detector/Focus Coil module interface Detector/Focus Coil module interface details details P. Fabbricatore INFN-Genova P. Fabbricatore INFN-Genova The actual distance from Focus#3 and Matching#1 (first coil of Detector Coil cold mass) is 600 mm. That side of Detector Coil Cryostat shall end with a gate valve DN400. It will be shown the details of Detector Coil Cryostat end with the connection to the gate valve. Beyond the gate valve it a business of Focus Coils designers (I have no details about geometrical lay- out ) An important issue to be commonly discussed is the transmission of the axial force. In the basic configuration the Detector Coils pushes with 119 kN against Focus Coils.

MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module

MICE COLLABORATION MEETING CERN March 29-April 1, 2004 MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface detailsDetector/Focus Coil module interface details P. Fabbricatore INFN-GenovaP. Fabbricatore INFN-Genova

Detector/Focus Coil module interface details Detector/Focus Coil module interface details

P. Fabbricatore INFN-GenovaP. Fabbricatore INFN-Genova

The actual distance from Focus#3 and Matching#1 (first coil of Detector Coil cold mass) is 600 mm.

That side of Detector Coil Cryostat shall end with a gate valve DN400.

It will be shown the details of Detector Coil Cryostat end with the connection to the gate valve.

Beyond the gate valve it a business of Focus Coils designers (I have no details about geometrical lay-out )

An important issue to be commonly discussed is the transmission of the axial force. In the basic configuration the Detector Coils pushes with 119 kN against Focus Coils.

Page 2: MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module

MICE COLLABORATION MEETING CERN March 29-April 1, 2004 MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface detailsDetector/Focus Coil module interface details P. Fabbricatore INFN-GenovaP. Fabbricatore INFN-Genova

Detector Coil Side to Focus Coils

600

From Match#1 end to Cryostat external surface we have 131 mm

Fucus#2 and Focus#3

Page 3: MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module

MICE COLLABORATION MEETING CERN March 29-April 1, 2004 MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface detailsDetector/Focus Coil module interface details P. Fabbricatore INFN-GenovaP. Fabbricatore INFN-Genova

Details of the gate valve DN400

Ed Black indicated #1 of the Series 101 DN400 modified to have a 50 mm thick copper plate instead of lead as quoted.

Page 4: MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module

MICE COLLABORATION MEETING CERN March 29-April 1, 2004 MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface detailsDetector/Focus Coil module interface details P. Fabbricatore INFN-GenovaP. Fabbricatore INFN-Genova

Geometrical details of the gate valve DN400

Page 5: MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module

MICE COLLABORATION MEETING CERN March 29-April 1, 2004 MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface detailsDetector/Focus Coil module interface details P. Fabbricatore INFN-GenovaP. Fabbricatore INFN-Genova

400

510

17 mm

55 mm

20 mm

5 mm 60 mm

150

Version with o-ring

ISO F standard

Page 6: MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module

MICE COLLABORATION MEETING CERN March 29-April 1, 2004 MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface detailsDetector/Focus Coil module interface details P. Fabbricatore INFN-GenovaP. Fabbricatore INFN-Genova

400

510

17 mm

55 mm

20 mm

5 mm 60 mm

150

Version with copper seal (CONFLAT)

Page 7: MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module

MICE COLLABORATION MEETING CERN March 29-April 1, 2004 MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface detailsDetector/Focus Coil module interface details P. Fabbricatore INFN-GenovaP. Fabbricatore INFN-Genova

Gap element Thickness (mm)

Cryostat 131

Connecting flange 76

O-ring 0-5

Gate valve 150

O-ring 0-5

Total 357-367

Summary thickness of gap elements between Match#1 and Focus #3

Page 8: MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module

MICE COLLABORATION MEETING CERN March 29-April 1, 2004 MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface detailsDetector/Focus Coil module interface details P. Fabbricatore INFN-GenovaP. Fabbricatore INFN-Genova

Focus #1

Coupling Focus #2

Focus #3

Match #1

Match #2

End #1 Center End #2

+2348 +168 -2242 +2205 +232 +69 +1056 -12 -1464

-37 -119

Axial forces in MICE lattice. Dimensions of Coils at RT

Configuration with field profile ..

Forces in kN

Page 9: MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module

MICE COLLABORATION MEETING CERN March 29-April 1, 2004 MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface detailsDetector/Focus Coil module interface details P. Fabbricatore INFN-GenovaP. Fabbricatore INFN-Genova

F=119 kN

The axial force may be reacted at the feet and/or through the gate valve connection.

Page 10: MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface details P. Fabbricatore INFN-Genova Detector/Focus Coil module

MICE COLLABORATION MEETING CERN March 29-April 1, 2004 MICE COLLABORATION MEETING CERN March 29-April 1, 2004 Detector/Focus Coil module interface detailsDetector/Focus Coil module interface details P. Fabbricatore INFN-GenovaP. Fabbricatore INFN-Genova

The connecting flange may be stiffened

(for force transmission)

More than 16 bolts may involved