MICROMANIPULATOR ASSEMBLY INR-5 INSTRUCTIONS

MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

MICROMANIPULATOR ASSEMBLY INR-5 INSTRUCTIONS

Page 2: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

© SYNTECH 2002

Hilversum, The Netherlands

Reproduction of text and/or drawings is permittedfor personal use. The use of reproductions in publicationsis only allowed if correct reference is made to SYNTECH

Page 3: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

MICROMANIPULATOR ASSEMBLYfor SSR, EAG and GC-EAG/SSR,

Type IRN-5

Page 4: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

MICROMANIPULATOR INR-5 ASSEMBLY - 1 -

Left-handpositioner

Indifferent electrodeclamp

Right-handpositioner

Probe

Preparationholder

Stimulus applicatorflow tube

Mounting thepositioners

Mounting the Probe

Connect probe cable(red dot on plug on top)

Connect grounding wire!

1

2

3

4

Page 5: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

MICROMANIPULATOR INR-5 ASSEMBLY - 2 -

Mounting the indifferentelectrode holder

Mounting the flow tube

Signal/Power interfacecable connection

Adjustment ofpreparation holders, flow tube

and electrode holders

5

6

7

8

9

Connect grounding wire!

Page 6: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

Groundingpost

Probeconnector

ProbeSwivelclampSwivel

clampSwivelclamp

Probe

Probe

Groundingwire

Groundingwire

Preparationplatform

Manipulatorin elevated

position

Elevationand Rotation

clamps

Handle

Stimulusair tube

Electrodemounting

shaft

Powerindicator

LED

Cable connectorto IDAC input

MANIPULATOR ASSEMBLY, INR-5

Page 7: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

Groundingwire

Probe

Groundingpost

Groundingpost

Groundingpost

Probecable

MANIPULATOR ASSEMBLY, INR-5 - DETAILS

Preparationplatform

Clamp withpreparation platform

Electrodeholder

Electrodeholder

Indifferent electrodeholder

Indifferent electrodeholder

Stimulusair tube

Probe

Swivelclamp

Page 8: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

DESCRIPTION The SYNTECH Micromanipulator Assembly, Type INR-5, has been developed to enable convenient registration of Single-Sensillum Recordings (SSR) and Electroantennogram (EAG) measurements in the laboratory. The system combines an interchangeable preparation platform with micro-manipulators, input probe, electrode holders and stimulus flow tube in a single compact unit. The instrument is suitable for standard laboratory experiments as well as for combined gas chromatography -electroantennographic or Single Sensillum detection (GC/EAD and GC/SSD). Recordings can be made using glass micro capillary electrodes or tungsten electrodes. The recording electrode is directly coupled to the input receptacle of a high input impedance miniature head stage (probe). Vertical and horizontal tool holders are available for the support of micro-knives as used for the tip recording method. Preparation holders can be made according to the size and shape of the insect under study. Optionally a micro thermistor air flow sensor can be installed; this air-sensor can be positioned close to the antennal preparation allowing simultaneous registration of the antennal signal and the air velocity over the preparation. Recently, a special high pass filter has been built-in in the central column. This filter effectively suppresses 50 -60 Hz interference, and thus makes the use of a Faraday shield unnecessary for EAG and GC-EAD recording. The base is provided with a receptacle for connection to an amplifier or main signal processing system. This interface is compatible with all Syntech amplifiers and data processing systems (IDAC-2, USB-IDAC, SERIAL IDAC and IDAC2000). The INR-2 does not need a battery or power supply, because power for the probe is provided via the interface cable.

Page 9: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

Different electrode holder

PROBE

Adjustable clamp

Fixing screw Z-Axis control

RIGHT-HANDMICROMANIPULATOR

Joystick

Ratio adjustment

Ring

Tension Adjustment

Ring

Coarse Z-movement

Fine Z-movement

Use small wrench to fix screw

Fixing screw

Ball joint

clamp

Page 10: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

OPERATION The figures show the overall construction and the various mechanical components of the instrument. To prepare the device for operation the following points should be carefully checked: 1. Mount the Probe and connect the cable to receptacle at the base of

the unit. NB. Never connect any other device to this receptacle! 2. Check the grounding wire connections from the indifferent electrode

holder clamp and from the probe to the central support of the device. The wires should make good contact with the grounding posts on the

central support.. 3. Set the filter switch to EAG on or off depending of the recording mode.

Make sure the switch is in its off position when making single sensillum recordings (SSR).

4. Adjust the position of the micromanipulators. The mounting screws should be well secured using a small hexagon wrench.

Adapt the ratio and tension adjustment rings of the joystick lever of the manipulators to the operator's requirements and feeling.

5. Arrange the neutral position of the electrode holders and the

preparation holder in such a way that the preparation is within the working range of the manipulator X-Y-Z movements .

6. Mount the air flow tube and fix its position with respect to the

preparation site.

Page 11: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

Electrode preparation

Page 12: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

ELECTRODE PREPARATION The use of SYNTECH electrode holders and the insertion of electrode

wire and glass pipette is illustrated in the figure. Note that the body of the different ('recording') electrode, which is

mounted onto the PROBE, is not on ground potential. It is connected to the output of the first operational amplifier inside the PROBE, thus forming a so called 'guard'. Such a guard circuit constitutes an effective shield against noise interference and eliminates the effect of leakage currents across the input. Therefore, do not connect the body of this electrode to ground, and prevent it from making direct contact with the indifferent electrode or any grounded part of the instrument or set up.

Practice has thought that in most applications AgCl coating of the silver wires is not necessary, because the input 'window' of the PROBE allows offset voltages of up to 400 mV.

Preparing the micropipettes For single sensillum recording the tip size of the recording glass

pipette electrode should be adjusted to the proper size depending on the recording method.

For EAG recording purposes the tips of most glass micropipettes are too fine. Therefore, carefully break off the tips with the help of fine forceps to an inner diameter wide enough to enable insertion of an excised antenna.

A good stereo dissecting microscope is indispensable for this work. Preparing the Ringer/PVP solution Add an amount of about 10% by volume of polyvinylpyrrolidone

(PVP) to an aqueous solution of 0.1 N KCl or other suitable insect Ringer solution. Shake well and let it stand for a while until the solution becomes clear. Do not prepare more than l00 ml at a time, and store the solution in a refrigerator between experiments.

Filling the micropipettes Pipettes with a relative wide tip fill spontaneously due to capillary ac-

tion when the tip is dipped into the Ringer/PVP solution. Fine tipped pipettes are easily filled by dipping and simultaneous sucking from the wide end through a well fitting tube.

Take care to fill only the first 10 - 15 mm from the tip. Fill the micropipettes shortly before making the antennal preparation.

Page 13: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

GAIN DC LEVEL AC LEVEL

DCRETURN

AC FILTER

ON

OFF

INPUT

STATUSSIGNAL

10 10

50 50100 100200 200

500 500

1000 1000

- - ++

off

5

10

1

DC AC

AntennaIndifferentelectrode Different

electrode

PROBE

Grounding wire

Grounding wire

Continuous air flow inlet

Stimulus pipette

test substance

Stimulus Application

Page 14: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

Sensorhead

Mountingclamp

AIR SPEED SENSOR ATTACHMENT

Page 15: MICROMANIPULATOR ASSEMBLY INR-5 - Kirchzarten · 2. Check the grounding wire connections from the indifferent electrode holder clamp and from the probe to the central support of the

COMPUTER withINTERFACE CARD

PRINTER

PROGRAMSOFTWARE

TEST STIMULUS

EFFLUENTMIXING TUBE

ASSEMBLY

A I R D C A C D C

A I R

E X T. P O W E R / R EM O TE

T A P E

R E C .

10 10

STIM U LUS C O NTRO LL ERCS-05

1

2 2

3 3

4 45 6

7 7

8 8

9 9

0.1

0.2

0.3

0.4

0.50.8

1

2

3

5

10

POWER

START

PEDAL

PULSE

PULSE DURATION

FLOWCONT INUO US

FLOW

NORMAL COM P L.

DELAY

s

STIMULUS CONTROLLER

START PEDAL

DC (EAD) SIGNAL

GC/EAD Recording and analysisProgram for WINDOWS

CH AN NE L 2

CH AN NEL 1

DC

DCDC

(GC )

(E AG )BA S E LIN ECO N TR OL

S T IM UL USPUL SE

T RIG G ERP UL SE

ACCH AN NE L( SP IKES )

A/BSE L E CTAC/DC PROBE( A=lo w )

10.1

0.2

0.3

0 .40.6

0.7

0.8

0.9

0.5

PC

AUTOSPIKEMA NUA LAU TO

AC A MP L . ADJ .

IDACbo x

Signal Interface Box