26
2 Harbour I N D U S T R I E S High Performance Wire & Cable US 800 659 4733 800 65 WIRED Canada 450 293 5304 www.harbourind.com e-mail - [email protected] Founded in 1965, Harbour Industries’ vision was to fill the gap between the demand for high quality, high performance wire and cable and the supply available at the time. The military's stringent require- ments for quality wire and cable shipped in a timely manner were the formative guidelines for today's Harbour. Attention to detail and a respect for the customer's needs have enabled Harbour to grow in markets that demand quality, consistency and availability. Throughout it’s history Harbour has stressed the importance of an efficient, productive manufacturing facility. A number of moves and property acquisitions have taken place, propelling Harbour to the forefront of the Mil-Spec wire and cable industry. Today Harbour boasts TFE extrusion capacity unparalleled in North America, extensive jacketing lines and high speed braiding equipment to support a wide range of lead wires; shielded and jacketed cables; and coaxial cables. Additional product lines include silicone rubber insulated mil-spec wire and cable and corresponding UL/CSA styles. Harbour’s mission statement is to remain competitive while continuing to develop processes and procedures to ensure compliance with all mil-spec wire and cable requirements. Harbour’s reputation for quality, con- sistency and a strong technical orientation has resulted in approvals for a variety of military constructions. Since its first day producing mil-spec wire and cable, Harbour has recognized the importance of meeting the needs of government suppliers. Today Harbour also understands the importance of maintaining this focus as many manufacturers have designed systems using mil-spec requirements independently of any government agency. This has increased the importance of ensuring the ability to produce “obsolete” specification material and transitioning to commercial versions of those items. Ultimately quality is the goal and focus of Harbour Industries. Certified to ISO-9001, Harbour’s quality system ensures that what we manufacture meets or exceeds our customer’s requirements for product quality, performance and delivery.

MilSpec Catalog

Embed Size (px)

Citation preview

HarbourI N D U S T R I E SHigh Performance Wire & Cable

Founded in 1965, Harbour Industries vision was to fill the gap between the demand for high quality, high performance wire and cable and the supply available at the time. The military's stringent requirements for quality wire and cable shipped in a timely manner were the formative guidelines for today's Harbour. Attention to detail and a respect for the customer's needs have enabled Harbour to grow in markets that demand quality, consistency and availability. Throughout its history Harbour has stressed the importance of an efficient, productive manufacturing facility. A number of moves and property acquisitions have taken place, propelling Harbour to the forefront of the Mil-Spec wire and cable industry. Today Harbour boasts TFE extrusion capacity unparalleled in North America, extensive jacketing lines and high speed braiding equipment to support a wide range of lead wires; shielded and jacketed cables; and coaxial cables. Additional product lines include silicone rubber insulated mil-spec wire and cable and corresponding UL/CSA styles. Harbours mission statement is to remain competitive while continuing to develop processes and procedures to ensure compliance with all mil-spec wire and cable requirements. Harbours reputation for quality, consistency and a strong technical orientation has resulted in approvals for a variety of military constructions. Since its first day producing mil-spec wire and cable, Harbour has recognized the importance of meeting the needs of government suppliers. Today Harbour also understands the importance of maintaining this focus as many manufacturers have designed systems using mil-spec requirements independently of any government agency. This has increased the importance of ensuring the ability to produce obsolete specification material and transitioning to commercial versions of those items. Ultimately quality is the goal and focus of Harbour Industries. Certified to ISO-9001, Harbours quality system ensures that what we manufacture meets or exceeds our customers requirements for product quality, performance and delivery.

US 800 659 4733 800 65 WIRED Canada 450 293 5304 www.harbourind.com e-mail - [email protected]

2

Table of

Contents

Single Conductor ConstructionsMIL-W-16878 - Extruded TFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 M16878/4, /5, /6, /23, /25, /27 NEMA HP3 Types E, EE, ET, EN, EEN, ETN . . . . . . . . . . . . . . . . . .4 replaces M16878 MIL-W-16878 - Extruded FEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 M16878/11, /12, /13 NEMA HP4 Types K, KK, KT, KZ, KKZ, KZT . . . . . . . . . . . . . . . . . .6 replaces M16878 MIL-DTL-16878 - Wrapped TFE . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 M16878/20, /22, /24, /26, /28, /34, /35 MIL-DTL-16878 - Extruded Silicone Rubber . . . . . . . . . . . . . . . . . . .8 M16878/7, /8, /29, /30, /31, /32 MIL-W-22759 - Extruded TFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9, 10 M22759/9, /10, /11, /12, /20, /21, /22, /23 MIL-W-22759 - Mineral Filled TFE . . . . . . . . . . . . . . . . . . . . . . . . . .11 M22759/5, /6, /7, /8 MIL-W-22759 - Extruded ETFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 M22759/16, /17, /18, /19 MIL-W-81822 - Extruded TFE or ETFE . . . . . . . . . . . . . . . . . . . . . . .13 M16878/4, /5, /6, /23, /25, /27 UL and CSA Hook Up and Lead Wire Index . . . . . . . . . . . . . . . . . . . .14

Multiconductor ConstructionsMIL-DTL-27500 - Base Specification . . . . . . . . . . . . . . . . . . . . . . . . . .16 MIL-DTL-27500 - Type TE-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 M22759/16 Primary conductors MIL-DTL-27500 - Type TG-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 M22759/18 Primary conductors MIL-DTL-27500 - Type RC-06 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 M22759/11 Primary conductors, wrapped PTFE jacket Type STJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Commercial equivalent to Type RC-06 MIL-DTL-27500 - Type RC-09 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 M22759/11 Primary conductors, extruded FEP jacket Type SE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Commercial equivalent to Type RC-09 MIL-C-55021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 M16878/4 or M16878/5 Primary conductors MIL-C-17 Coaxial Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23, 24 Buying Directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25, 26

MIL-W-16878 Extruded TFEFor Reference Only*

Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260 C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment, and PTFE can be used in systems subject to current overload conditions or mechanical stress.

Similar mil-spec constructions available (call factory for details) - MIL-W-81822/6, MPD-1506

M16878/4Voltage Rating Temperature ( C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 28 19/40 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29 600 200 SPC

M16878/51000 200 SPC

M16878/6250 200 SPC

M16878/23600 260 NPC

M16878/251000 260 NPC

M16878/27250 260 NPC

10/.030 10/.032 10/.033 10/.035 10/.036 10/.036 10/.039 10/.040 10/.040 10/.044 10/.045 10/.045 10/.050 10/.051 10/.052 10/.058 10/.058 10/.061 10/.069 10/.069 13/.080 13/.095 15/.114 13/.134 -

Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.042 6/.024 10/.032 15/.043 6/.025 10/.033 15/.045 6/.027 10/.035 15/.046 6/.027 10/.036 15/.046 6/.028 10/.036 15/.049 6/.031 10/.039 15/.049 6/.031 10/.040 15/.050 6/.032 10/.040 15/.054 6/.036 10/.044 15/.055 6/.036 10/.045 15/.055 6/.038 10/.045 15/.060 6/.042 10/.050 15/.061 6/.042 10/.051 15/.062 6/.044 10/.052 15/.068 6/.050 10/.058 15/.069 6/.052 10/.058 15/.071 10/.061 15/.079 10/.069 15/.080 10/.069 18/.089 13/.080 18/.106 13/.095 21/.125 15/.114 19/.145 13/.134 24/.209 -

15/.040 15/.042 15/.043 15/.045 15/.046 15/.046 15/.049 15/.049 15/.050 15/.054 15/.055 15/.055 15/.060 15/.061 15/.062 15/.068 15/.069 15/.071 15/.079 15/.080 18/.089 18/.106 21/.125 19/.145 24/.209

6/.022 6/.024 6/.025 6/.027 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.052 -

All figures referenced are nominal.

*MIL-W-16878 is obsolete and has been replaced by NEMA HP 3 See page 4 of this catalog.

3

NEMA HP3 Types E, EE, ET Replaces M16878

Applications For use in internal wiring of electronic equipment and appliances. Nema HP-3, TFE lead wires have a low coefficient of friction which promotes easy handling. The insulation also resists hot soldering irons, is self extinguishing, non-flammable, has excellent chemical resistance and is suitable for immersion in gasoline, gasoline vapor and at 80 C. maximum, oil. PTFE insulation is not affected by weathering, ozone, or corrosive environments.

Type EVoltage Rating Temperature ( C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 28 19/40 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29 600 200 SPC

Type EE1000 200 SPC

Type ET250 200 SPC

Type EN600 260 NPC

Type EEN1000 260 NPC

Type ETN250 260 NPC

10/.030 10/.032 10/.033 10/.035 10/.036 10/.036 10/.039 10/.040 10/.040 10/.044 10/.045 10/.045 10/.050 10/.051 10/.052 10/.058 10/.058 10/.061 10/.069 10/.069 13/.080 13/.095 15/.114 13/.134 -

Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.042 6/.024 10/.032 15/.043 6/.025 10/.033 15/.045 6/.027 10/.035 15/.046 6/.027 10/.036 15/.046 6/.028 10/.036 15/.049 6/.031 10/.039 15/.049 6/.031 10/.040 15/.050 6/.032 10/.040 15/.054 6/.036 10/.044 15/.055 6/.036 10/.045 15/.055 6/.038 10/.045 15/.060 6/.042 10/.050 15/.061 6/.042 10/.051 15/.062 6/.044 10/.052 15/.068 6/.050 10/.058 15/.069 6/.052 10/.058 15/.071 10/.061 15/.079 10/.069 15/.079 10/.069 18/.089 13/.080 18/.106 13/.095 21/.125 15/.114 19/.145 13/.134 24/.209 -

15/.040 15/.042 15/.043 15/.045 15/.046 15/.046 15/.049 15/.049 15/.050 15/.054 15/.055 15/.055 15/.060 15/.061 15/.062 15/.068 15/.069 15/.071 15/.079 15/.079 18/.089 18/.106 21/.125 19/.145 24/.209

6/.022 6/.024 6/.025 6/.027 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.052 -

All figures referenced are nominal.

Products referenced on this page are manufactured with extruded PTFE insulation. Tape wrapped versions are also available, contact factory for details.

4

MIL-W-16878 Extruded FEPFor Reference Only*

Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 200 C. FEP is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment, and FEP can be used in systems subject to current overload conditions or mechanical stress.

M16878/11Voltage Rating Temperature ( C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 26 1/26 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 16 1/16 16 19/29 14 1/14 14 19/27 12 19/25 10 37/26 8 133/29 600 200 SPC

M16878/121000 200 SPC

M16878/13250 200 SPC

10/.030 10/.032 10/.033 10/.035 10/.036 10/.039 10/.040 10/.044 10/.044 10/.045 10/.050 10/.050 10/.052 10/.058 10/.058 10/.061 10/.069 10/.074 10/.080 12/.087 14/.095 15/.114 -

Insulation thickness (mils) / Overall diameter (inches) 15/.040 15/.042 15/.043 15/.045 15/.046 15/.049 15/.050 15/.054 15/.054 15/.055 15/.060 15/.060 15/.062 15/.068 15/.068 15/.071 15/.079 16/.083 18/.089 17/.098 20/.106 21/.125 19/.145 24/.209

6/.022 6/.024 6/.025 6/.027 6/.028 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.050 -

All figures referenced are nominal.

*MIL-W-16878 is obsolete and has been replaced by NEMA HP 4 See page 6 of this catalog.

5

NEMA HP4 Types K, KK, KT Replaces M16878

Applications For use in internal wiring of electronic equipment and appliances. NEMA HP4, FEP lead wires have a low coefficient of friction which promotes easy handling. The insulation also resists hot soldering irons, is self extinguishing, non-flammable, has excellent chemical resistance and is suitable for immersion in gasoline, gasoline vapor and at 80 C. maximum, oil. FEP insulation is not affected by weathering, ozone, or corrosive environments.

Type KVoltage Rating Temperature ( C.) Conductor Type AWG size & stranding 30 1/30 30 7/38 28 1/28 28 7/36 28 19/40 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29 600 200 SPC

Type KK1000 200 SPC

Type KT250 200 SPC

Type KZ600 150 TPC

Type KKZ1000 150 TPC

Type KKZT250 150 TPC

10/.030 10/.032 10/.033 10/.035 10/.036 10/.036 10/.039 10/.040 10/.040 10/.044 10/.045 10/.045 10/.050 10/.051 10/.052 10/.058 10/.059 10/.061 10/.069 10/.068 14/.080 14/.095 15/.114 13/.134 -

Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.042 6/.024 10/.032 15/.043 6/.025 10/.033 15/.045 6/.027 10/.035 15/.045 6/.027 10/.036 15/.046 6/.028 10/.036 15/.049 6/.031 10/.039 15/.049 6/.031 10/.040 15/.050 6/.032 10/.040 15/.054 6/.036 10/.044 15/.054 6/.036 10/.045 15/.055 6/.038 10/.045 15/.060 6/.042 10/.050 15/.060 6/.042 10/.051 15/.062 6/.044 10/.052 15/.068 6/.050 10/.058 15/.069 6/.052 10/.059 15/.070 10/.061 16/.079 10/.069 16/.079 10/.068 18/.089 14/.080 19/.106 14/.095 20/.125 15/.114 18/.145 13/.134 24/.209 -

15/.040 15/.042 15/.043 15/.045 15/.045 15/.046 15/.049 15/.049 15/.050 15/.054 15/.054 15/.055 15/.060 15/.061 15/.052 15/.058 15/.069 10/.061 16/.078 16/.079 18/.089 19/.106 20/.125 18/.145 24/.209

6/.022 6/.024 6/.025 6/.027 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.038 6/.042 6/.042 6/.044 6/.050 6/.052 -

All figures referenced are nominal.

6

MIL-DTL-16878 Wrapped TFEFor Reference Only*

Applications For use in electronic and electrical applications with ambient temperatures up to 200 C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment, and PTFE can be used in systems subject to current overload conditions or mechanical stress.

M16878/20Voltage Rating Temperature ( C.) Conductor Type AWG size & stranding 30 1/30 28 1/28 28 7/36 26 1/26 26 7/34 26 19/38 24 1/24 24 7/32 24 19/36 22 1/22 22 7/30 22 19/34 20 1/20 20 7/28 20 19/32 18 1/18 18 7/26 18 19/30 16 1/16 16 19/29 14 19/27 12 19/25 12 37/28 12 65/30 10 37/26 8 133/29 6 133/27 250 200 SPC

M16878/21600 200 SPC

M16878/221000 200 SPC

M16878/24250 260 NPC

M16878/26600 260 NPC

M16878/281000 260 NPC

M16878/341000 SPC

M16878/351000 NPC

6/.022 6/.025 6/.027 6/.028 6/.031 6/.031 6/.032 6/.036 6/.036 6/.037 6/.042 6/.042 6/.044 6/.050 6/.050 -

10/.030 10/.033 10/.035 10/.036 10/.039 10/.039 10/.040 10/.044 10/.044 10/.045 10/.050 10/.050 10/.052 10/.058 10/.058 11/.061 11/.069 11/.069 12/.074 14/.080 15/.095 15/.114 14/112 13/.134 -

Insulation thickness (mils) / Overall diameter (inches) 15/.040 6/.022 10/.030 15/.040 15/.043 6/.025 10/.033 15/.043 15/.045 6/.027 10/.035 15/.045 15/.046 6/.028 10/.036 15/.046 15/.049 6/.031 10/.039 15/.049 15/.049 6/.031 10/.039 15/.049 15/.050 6/.032 10/.040 15/.050 15/.054 6/.036 10/.044 15/.054 15/.054 6/.036 10/.044 15/.054 15/.055 6/.037 10/.045 15/.055 15/.060 6/.042 10/.050 15/.060 15/.060 6/.042 10/.050 15/.060 15/.062 6/.044 10/.052 15/.062 15/.068 6/.050 10/.058 15/.068 15/.068 6/.050 10/.058 15/.068 15/.071 11/.061 15/.071 16/.079 11/.069 16/.079 16/.079 11/.069 16/.079 16/.083 12/.074 16/.083 16/.089 14/.080 16/.089 17/.106 15/.095 17/.106 17/.125 15/.114 17/.125 17/.123 14/.112 17/.123 17/.127 17/.145 13/.134 17/.145 20/.209 20/.209 25/.263 25/.263

15/.045 15/.049 15/.054 15/.060 15/.068 16/.079 16/.089 17/.106 17/.125 17/.123 17/.145 20/.209 25/.263

15/.045 15/.049 15/.054 15/.060 15/.068 16/.079 16/.089 17/.106 17/.125 17/.123 17/.145 20/.209 25/.263

All figures referenced are nominal.

*MIL-W-16878 is obsolete and has been replaced by NEMA HP 3

7

MIL-DTL-16878 Silicone Rubber

Applications For internal wiring of electrical equipment and where moisture, cold and/or heat may be present. Styles with fiberglass insulation offer excellent abrasion resistance.

M16878/7Voltage Rating Temperature ( C.) Conductor Type AWG size & stranding 24 7/32 22 7/30 20 7/28 20 10/30 18 7/26 18 16/30 16 19/29 16 26/30 14 19/27 14 41/30 12 19/25 12 65/30 10 37/26 10 105/30 8 133/29 6 133/27 4 133/25 2 133/23 1 259/25 1/0 259/24 2/0 259/23 3/0 259/22 4/0 259/21 600 200 SPC

M16878/81000 200 SPC

M16878/29600 150 TPC

M16878/301000 150 TPC

M16878/311000 150 TPC

M16878/321000 200 SPC

16/.055 16/.061 16/.069 16/.069 16/.079 16/.079 16/.088 16/.088 24/.119 24/.119 24/.138 24/.138 22/.161 -

Insulation thickness (mils) / Overall diameter (inches) 32/.087 16/.055 32/.087 32/.093 16/.061 32/.093 32/.101 16/.069 32/.101 32/.101 16/.069 32/.101 32/.111 16/.079 32/.111 32/.111 16/.079 32/.111 32/.120 16/.088 32/.120 32/.120 16/.088 32/.120 47/.166 24/.119 47/.166 47/.166 24/.119 47/.166 47/.185 24/.138 47/.185 47/.185 24/.138 47/.185 47/.205 47/.205 44/.205 22/.161 44/.205 63/.294 63/.294 63/.338 63/.338 63/.394 63/.394 63/.460 63/.460 78/.534 78/.534 78/.580 78/.580 78/.633 78/.633 88/.709 88/.709 78/.757 78/.757

35/.094 35/.100 35/.108 35/.108 35/.118 32/.111 35/.127 35/.127 52/.176 52/.176 52/.195 47/.185 52/.215 47/.205 72/.312 72/.356 73/.414 72/.478 87/.552 87/.598 87/.651 88/.709 87/.775

35/.094 35/.100 35/.108 35/.108 35/.118 32/.111 35/.127 35/.127 52/.176 52/.176 52/.195 47/.185 52/.215 47/.205 72/.312 72/.356 73/.414 72/.478 87/.552 87/.598 87/.651 88/.709 87/.775

All figures referenced are nominal.

8

MIL-W-22759 Extruded TFE

Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260 C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment and can be used in systems subject to current overload conditions or mechanical stress. Identification Surface printed in accordance with MIL-W-22759

M22759/9Voltage Rating Temperature ( C.) Conductor Type AWG size & stranding 28 7/36 26 19/38 24 19/36 22 19/34 20 19/32 18 19/30 16 19/29 14 19/27 12 19/25 10 37/26 8 133/29 1000 200 SPC

M22759/101000 260 NPC

M22759/11600 200 SPC

M22759/12600 260 NPC

Insulation thickness (mils) / Overall diameter (inches) 14/.043 14/.043 9/.033 15/.048 14/.048 10/.038 15/.053 14/.053 10/.043 15/.060 15/.060 9/.049 15/.068 15/.068 10/.058 15/.078 15/.078 10/.068 15/.085 15/.085 10/.075 16/.100 16/.100 11/.090 17/.120 17/.120 13/.111 16/.141 16/.141 15/.139 22/.207 19/.202

9/.033 10/.038 10/.043 9/.049 10/.058 10/.068 10/.075 11/.090 12/.111 15/.139 19/.202

All figures referenced are nominal.

9

MIL-W-22759 Extruded TFE

Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260 C. PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment and can be used in systems subject to current overload conditions or mechanical stress. Identification Surface printed in accordance with MIL-W-22759

M22759/20Voltage Rating Temperature ( C.) Conductor Type AWG size & stranding 28 7/36 26 19/38 24 19/36 22 19/34 20 19/32 1000 200 SPTF

M22759/211000 260 NPTF

M22759/22600 200 SPTF

M22759/23600 260 NPTF

Insulation thickness (mils) / Overall diameter (inches) 15/.043 14/.043 10/.033 15/.048 15/.048 10/.038 15/.053 15/.053 10/.043 16/.060 15/.060 10/.049 15/.068 15/.068 10/.058

9/.033 10/.038 10/.043 10/.049 10/.058

All figures referenced are nominal.

10

MIL-W-22759 Mineral Filled TFE

Applications For use in electronic and electrical applications with ambient or conductor temperatures up to 260 C. Mineral filled PTFE is self-extinguishing, non-flammable, not affected by weathering, ozone or corrosive environment and can be used in systems subject to current overload conditions or mechanical stress. Mineral filled PTFE insulation also offers improved abrasion resistance over standard PTFE constructions. Identification Surface printed in accordance with MIL-W-22759

M22759/5Voltage Rating Temperature ( C.) Conductor Type AWG size & stranding 24 19/36 22 19/34 20 19/32 18 19/30 16 19/29 14 19/27 12 19/25 10 19/26 600 200 SPC

M22759/6600 260 NPC

M22759/7600 200 SPC

M22759/8600 260 NPC

Insulation thickness (mils) / Overall diameter (inches) 26/.075 25/.075 19/.062 28/.085 27/.085 22/.073 29/.095 28/.095 22/.082 31/.110 31/.110 22/.092 36/.125 35/.125 24/.102 38/.143 37/.143 23/.115 38/.160 37/.160 24/.134 35/.179 35/.179 25/.158

19/.062 21/.073 22/.082 22/.092 24/.102 23/.115 24/.134 24/.158

All figures referenced are nominal.

HarbourI N D U S T R I E SHigh Performance Wire & Cable

11

MIL-W-22759 Extruded ETFE

Applications For use in aerospace, electronic and electrical installations with ambient or conductor temperatures up to 150 C. ETFE insulation is abrasion resistant, potable and offers excellent chemical resistance. Identification Surface printed in accordance with MIL-W-22759 Similar mil-spec constructions available (call factory for details) - MIL-W-81822/13

M22759/16Voltage Rating Temperature ( C.) Conductor Type AWG size & stranding 26 19/38 24 19/36 22 19/34 20 19/32 18 19/30 16 19/29 14 19/27 12 37/28 10 37/26 8 133/29 6 133/27 4 133/25 2 665/30 1 817/30 0 1045/30 00 1330/30 600 150 TPC

M22759/17600 150 SPTF

M22759/18600 150 TPC

M22759/19600 150 SPTF

Insulation thickness (mils) / Overall diameter (inches) 11/.040 7/.032 11/.045 11/.045 7/.036 11/.052 11/.052 7/.043 11/.060 11/.060 7/.051 12/.071 7/.061 13/.079 9/.070 13/.093 9/.085 14/.114 11/.107 15/.139 13/.134 18/.199 23/.250 27/.312 29/.388 31/.431 32/.479 44/.546 -

6/.032 6/.036 6/.043 6/.051 -

All figures referenced are nominal.

12

MIL-W-81822 Extruded TFE or ETFEApplications Designed for solderless wrap connections in electrical and electronic devices and equipment. Part number example: M81822/6-A24-9 M81822 Base Specification /6 Cable Specification A ConductorDesignation 22 AWG Size 9 Color Code

Conductor Designated by applicable call out as indicated by letter designator located directly before AWG size call out in part number. Designations as follows: A - solid silver plated copper B - solid silver plated oxygen free copper C - solid silver plated high strength, high conductivity copper alloy Insulation Extruded TFE M81822/6 Extruded ETFE M81822/13, thin wall versions designated by V after AWG size call out in part number

M81822/6Voltage Rating Temperature ( C.) AWG size & stranding 30 1/30 28 1/28 26 1/26 24 1/24 22 1/22 20 1/20 18 1/18 300 200

M81822/13300 150

M81822/13 V styles300 150

6/.022 6.5/.026 7.5/.031 11/.042 12/.048 12/.056 13/.065

Insulation thickness (mils) / Overall diameter (inches) 5/.019 7/.026 7/.029 7/.034 7/.039 7/.046 7/.054

5/.023 5/.026 5/.030 -

All figures referenced are nominal.

HarbourI N D U S T R I E SHigh Performance Wire & Cable

13

UL & CSA Hook up and Lead Wire IndexInsulation MaterialPTFE

UL Style1164 1180 1198 1199 1212 1213 1659 1815

CSA ClassificationClass I Group A/B FT1 Class I Group A/B FT1 Class I Group A/B FT1 Class I Group A/B FT1 Class I Group A/B FT1 Class I Group A/B FT1 Class I Group A/B FT1 Class I Group A/B FT1 Class I Group A/B FT1 Class I Group A FT1 Class I Group A FT1 Class I Group A FT1 Class I Group A/B FT1 Class I Group A/B FT1 Class I Group A/B FT1 Class I Group A/B FT1 Class Group A FT1 Class Group A FT1 Class Group A FT1

AWG Size Range30-10 28-10 30-10 28-10 30-16 30-16 30-10 30-10 30-14 30-10 30-4/0 30-4/0 30-10 30-10 30-4/0 30-4/0 30-10 24-10 24-10 30-10 30-10 22-16 22-16 18-4/0 18-4/0 24-12 24-18 24-4/0 24-10 22-8 24-2 24-2 22-2

Voltage Rating (Volts)300 300 600 600 N.SN.S UL/150 CSA

Temperature Rating (C)150 200 150 200 80 105 250 250 80 105 200(UL)/180(CSA) 150 200(UL)/180(CSA) 150 150 150 150 150 150 200 200 150 200 150 200 200 200 200 250 250 250 450 450

600 300 N.S. N.S. 600 600 300 300 300 600 300 300 600 300 600 300 300 600 600 600 300 600 300 300 600 300 600

FEP

1226 1227 1330 1331 1332 1333

ETFE

1643 1644 1671 10125 10126 10109 10086

PFA

1709

Silicone Rubber

SFF-1, 3068 SEW-1, 3122 SFF-2, 3069,3100, 3101, 3278 SF-2, 3074, 3075, 3172, 3231 3139 3367 3530

SEWF-1 SEW-1 SEWF-2 SEW-2 Class I, Group A/B FT1 Class I, Group A/B FT2 Class I, Group A/B FT2 Class I, Group A/B FT1 Class I, Group A/B FT1 Class I, Group A/B FT1 Class I, Group A/B FT1 Class I, Group A/B FT1

Ceramic & Fiberglass Mica & Fiberglass

5315 5331 5288 5128 5107

Additional UL and CSA styles are available. Call factory for more information. All figures referenced are nominal.

14

MIL-C-55021Applications One, two or three conductor cables, shielded or unshielded covering mil-spec requirements for use as internal wiring of electrical equipment. Available in a variety of configurations, defined by the specific milspec part number referenced. Part number example: M-C-55021 / 2B E24C904-903-902STWSpecification/ Revision Base wire Specification AWG Size Conductor Material Color code of 1st Wire Color code of 2nd Wire Color code of 3rd Wire Type of Covering

MIL-C-55021/2B

E

24

C

904

903

902

STW

Specification/Revision Details of cable consruction as outlined in the governing mil-spec and revision level. Basic Wire Specification E = MIL-W-16878/4

EE = MIL-W-16878/5

AWG Size Per individual conductor style sheets for stranding and plating. Conductor Material C = Annealed copper S = Copper clad steel H = High strength copper alloy

Color code A three digit code is used to indicate the color of the wire and any identifying stripes. The first digit is the color of the insulation, the second and third digits indicate the color of the first and second stripes, where applicable. The number of color codes contained in the part number also indicates the number of conductors in the cable. In the example above there are three conductors, all of which have white insulation. The stripes on the first conductor are black and yellow, the stripes on the second conductor are black and orange and on the third they are black and red. Type of cable covering Jacket color for M55021 is white unless otherwise specified. Shields, when applied, are constructed of the same conductor materials as the base wire. F = Extruded FEP S = Shielded and unjacketed SF = Shielded and jacketed with FEP STW = Shielded and PTFE tape jacket T = PTFE tape jacket U = Unshielded and unjacketed Similar mil-spec constructions available (call factory for details) MIL-C7078, MIL-27072, MIL-47206, MIL-13929, MPD-1507

15

MIL-DTL-27500ApplicationsSingle and multiconductor cables, shielded or unshielded covering mil-spec requirements for special purpose and power electrical cable. Available in a variety of configurations, defined by the specific part mil-spec part number referenced.

Part number example: M27500A20RC3S06Specification Number Identification method AWG Size Basic Wire Specification Number of conductors Shield style and material Jacket material

M27500

A

20

RC

3

S

06

Identification methodsAll ID methods are in accordance with Table IIIA, IIIC, or IIID of MIL-C-27500 A = solid colors (Table IIIA) B = Solid colors (Table IIIC) with band markings (Table IIID) - = All conductors white with stripes (Table IIIA)

AWG sizePer individual conductor style sheets for stranding and plating

Basic Wire SpecificationEA E RA RB V A WA SA TA LE LH = MIL-W-22759/1 = MIL-W-22759/2 = MIL-W-22759/3 = MIL-W-22759/4 = MIL-W-22759/5 = MIL-W-22759/6 = MIL-W-22759/7 = MIL-W-22759/8 = MIL-W-22759/9 = MIL-W-22759/10 RC RE TE TF TG TH TK TL TM TN = MIL-W-22759/11 = MIL-W-22759/12 = MIL-W-22759/16 = MIL-W-22759/17 = MIL-W-22759/18 = MIL-W-22759/19 = MIL-W-22759/20 = MIL-W-22759/21 = MIL-W-22759/22 = MIL-W-22759/23

Shield Style and MaterialSingle Double C R F Z M K N P S T U Y L W V U Nickel clad copper Stainless steel Silver plated high strength copper Nickel plated copper Nickel plated high strength copper Silver plated copper Tin plated copper No shield

Number of conductors 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Jacket materialSingle Double 01 51 03 53 04 53 05 55 06 56 07 57 09 59 10 60 11 61 12 62 14 64 15 65 16 66 17 67 18 68 20 70 21 71 00 00 Extruded PVC White polyimide braid with polyimide finisher over polyester tape Polyester braid with high temperature finish over polyester tape Extruded clear FEP PTFE tape wrap White PTFE treated glass braid over pre-sintered PTFE tape Extruded white FEP Extruded clear PVDF Polyimide/FEP tape with FEP outer surface Polyimide/FEP tape with polyimide outer surface Extruded white ETFE Extruded clear ETFE Aromatic polyimide braid with high temperature finish over pre-sintered PTFE tape Extruded white ECTFE Extruded clear ECTFE Extruded white PFA Extruded clear PFA No jacket

Similar mil-spec constructions available (call factory for details)MIL-C7078, MIL-27072, MIL-47206, MIL-13929, MPD-1507

16

MIL-DTL-27500 Type RC-06

Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/11. Identification In accordance with MIL-C-27500 Similar mil-spec constructions available (call factory for details) - MIL-C-7078, MIL-C-27072, MIL-W47206, MIS-C-13929, MPD-1507 Part NumberMS27500-26RC-1S06 MS27500-26RC-2S06 MS27500-26RC-3S06 MS27500-26RC-4S06 MS27500-24RC-1S06 MS27500-24RC-2S06 MS27500-24RC-3S06 MS27500-24RC-4S06 MS27500-22RC-1S06 MS27500-22RC-2S06 MS27500-22RC-3S06 MS27500-22RC-4S06 MS27500-20RC-1S06 MS27500-20RC-2S06 MS27500-20RC-3S06 MS27500-20RC-4S06 MS27500-18RC-1S06 MS27500-18RC-2S06 MS27500-18RC-3S06 MS27500-18RC-4S06 MS27500-16RC-1S06 MS27500-16RC-2S06 MS27500-16RC-3S06 MS27500-16RC-4S06 MS27500-14RC-1S06 MS27500-14RC-2S06 MS27500-14RC-3S06 MS27500-14RC-4S06 MS27500-12RC-1S06 MS27500-12RC-2S06 MS27500-12RC-3S06 MS27500-12RC-4S06

Primary (AWG)26 26 26 26 24 24 24 24 22 22 22 22 20 20 20 20 18 18 18 18 16 16 16 16 14 14 14 14 12 12 12 12

Stranding (No./AWG)19/38 19/38 19/38 19/38 19/36 19/36 19/36 19/36 19/34 19/34 19/34 19/34 19/32 19/32 19/32 19/32 19/30 19/30 19/30 19/30 19/29 19/29 19/29 19/29 19/27 19/27 19/27 19/27 19/25 19/25 19/25 19/25

Primary OD (inches).038 .038 .038 .038 .043 .043 .043 .043 .049 .049 .049 .049 .058 .058 .058 .058 .068 .068 .068 .068 .075 .075 .075 .075 .090 .090 .090 .090 .111 .111 .111 .111

Shield OD (inches).055 .092 .098 .108 .059 .102 .109 .120 .065 .114 .122 .135 .074 .132 .141 .156 .084 .152 .163 .181 .091 .166 .178 .198 .106 .196 .210 .234 .127 .238 .256 .289

Cable OD (inches).079 .116 .122 .132 .083 .126 .133 .144 .089 .138 .146 .159 .098 .156 .165 .180 .108 .176 .187 .205 .115 .190 .202 .222 .130 .220 .234 .258 .151 .262 .280 .313

Weight (lbs.)6 10 13 16 7 13 16 19 10 15 20 25 11 20 27 35 15 28 38 47 17 33 46 59 23 45 62 79 33 68 95 126

Cable configurations of up to 10 primaries are also available.

All figures referenced are nominal.

17

Type STJ Commercial equivalents to Type RC-06

Applications Electrical and electronic installations with ambient temperatures up to 200 C. and voltage requirements to 600 volts. Part Number1XE26-734STJ 2XE26-734STJ 3XE26-734STJ 4XE26-734STJ 1XE24-1936STJ 2XE24-1936STJ 3XE24-1936STJ 4XE24-1936STJ 1XE24-1934STJ 2XE24-1934STJ 3XE24-1934STJ 4XE24-1934STJ 1XE20-1936STJ 2XE20-1936STJ 3XE20-1936STJ 4XE20-1936STJ 1XE18-1936STJ 2XE18-1936STJ 3XE18-1936STJ 4XE18-1936STJ 1XE16-1936STJ 2XE16-1936STJ 3XE16-1936STJ 4XE16-1936STJ 1XE14-1936STJ 2XE14-1936STJ 3XE14-1936STJ 4XE14-1936STJ 1XE12-1936STJ 2XE12-1936STJ 3XE12-1936STJ 4XE12-1936STJ

Primary (AWG)26 26 26 26 24 24 24 24 22 22 22 22 20 20 20 20 18 18 18 18 16 16 16 16 14 14 14 14 12 12 12 12

Stranding (No./AWG)7/34 7/34 7/34 7/34 19/36 19/36 19/36 19/36 19/34 19/34 19/34 19/34 19/32 19/32 19/32 19/32 19/30 19/30 19/30 19/30 19/29 19/29 19/29 19/29 19/27 19/27 19/27 19/27 19/25 19/25 19/25 19/25

Primary OD (inches).038 .038 .038 .038 .043 .043 .043 .043 .049 .049 .049 .049 .058 .058 .058 .058 .068 .068 .068 .068 .075 .075 .075 .075 .090 .090 .090 .090 .111 .111 .111 .111

Shield OD (inches).055 .092 .098 .108 .059 .102 .109 .120 .065 .114 .122 .135 .074 .132 .141 .156 .084 .152 .163 .181 .091 .166 .178 .198 .106 .196 .210 .234 .127 .238 .256 .289

Cable OD (inches).073 .110 .116 .126 .077 .120 .127 .138 .083 .132 .140 .153 .092 .150 .159 .174 .102 .176 .187 .205 .109 .190 .202 .222 .124 .220 .234 .258 .145 .262 .280 .313

Weight (lbs.)6 10 13 16 7 13 16 19 10 15 20 25 11 20 27 35 15 28 38 47 17 33 46 59 23 45 65 82 33 68 95 126

Cable configurations of up to 10 primaries are also available. All figures referenced are nominal.

18

MIL-DTL-27500 Type RC-09

Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/11. Identification In accordance with MIL-C-27500 Similar mil-spec constructions available (call factory for details) - MIL-C-7078, MIL-C-27072, MIL-W47206, MIS-C-13929, MPD-1507 Part NumberMS27500-26RC-1S09 MS27500-26RC-2S09 MS27500-26RC-3S09 MS27500-26RC-4S09 MS27500-24RC-1S09 MS27500-24RC-2S09 MS27500-24RC-3S09 MS27500-24RC-4S09 MS27500-22RC-1S09 MS27500-22RC-2S09 MS27500-22RC-3S09 MS27500-22RC-4S09 MS27500-20RC-1S09 MS27500-20RC-2S09 MS27500-20RC-3S09 MS27500-20RC-4S09 MS27500-18RC-1S09 MS27500-18RC-2S09 MS27500-18RC-3S09 MS27500-18RC-4S09 MS27500-16RC-1S09 MS27500-16RC-2S09 MS27500-16RC-3S09 MS27500-16RC-4S09 MS27500-14RC-1S09 MS27500-14RC-2S09 MS27500-14RC-3S09 MS27500-14RC-4S09 MS27500-12RC-1S09 MS27500-12RC-2S09 MS27500-12RC-3S09 MS27500-12RC-4S09

Primary (AWG)26 26 26 26 24 24 24 24 22 22 22 22 20 20 20 20 18 18 18 18 16 16 16 16 14 14 14 14 12 12 12 12

Stranding (No./AWG)19/38 19/38 19/38 19/38 19/36 19/36 19/36 19/36 19/34 19/34 19/34 19/34 19/32 19/32 19/32 19/32 19/30 19/30 19/30 19/30 19/29 19/29 19/29 19/29 19/27 19/27 19/27 19/27 19/25 19/25 19/25 19/25

Primary OD (inches).038 .038 .038 .038 .043 .043 .043 .043 .049 .049 .049 .049 .058 .058 .058 .058 .068 .068 .068 .068 .075 .075 .075 .075 .090 .090 .090 .090 .111 .111 .111 .111

Shield OD (inches).055 .092 .098 .108 .059 .102 .109 .120 .065 .114 .122 .135 .074 .132 .141 .156 .084 .152 .163 .181 .091 .166 .178 .198 .106 .196 .210 .234 .127 .238 .256 .289

Cable OD (inches).073 .110 .116 .126 .077 .120 .127 .138 .083 .132 .140 .153 .092 .150 .159 .180 .102 .176 .187 .205 .109 .190 .202 .222 .124 .220 .234 .258 .145 .262 .280 .313

Weight (lbs.)6 10 13 16 7 13 16 19 9 14 19 24 11 19 26 35 14 27 37 47 16 32 45 59 23 45 62 79 32 65 91 123

Cable configurations of up to 10 primaries are also available.

All figures referenced are nominal.

19

Type SE Commercial equivalents to Type RC-09Applications Electrical and electronic installations with ambient temperatures up to 200 C. and voltage requirements to 600 volts.

Part Number1XE24-1936SE 2XE24-1936SE 3XE24-1936SE 4XE24-1936SE 1XE22-1934SE 2XE22-1934SE 3XE22-1934SE 4XE22-1934SE 1XE20-1932SE 2XE20-1932SE 3XE20-1932SE 4XE20-1932SE 1XE18-1930SE 2XE18-1930SE 3XE18-1930SE 4XE18-1930SE 1XE16-1929SE 2XE16-1929SE 3XE16-1929SE 4XE16-1929SE 1XE14-1927SE 2XE14-1927SE 3XE14-1927SE 4XE14-1927SE 1XE12-1925SE 2XE12-1925SE 3XE12-1925SE 4XE12-1925SE

Primary (AWG)24 24 24 24 22 22 22 22 20 20 20 20 18 18 18 18 16 16 16 16 14 14 14 14 12 12 12 12

Stranding (No./AWG)19/36 19/36 19/36 19/36 19/34 19/34 19/34 19/34 19/32 19/32 19/32 19/32 19/30 19/30 19/30 19/30 19/29 19/29 19/29 19/29 19/27 19/27 19/27 19/27 19/25 19/25 19/25 19/25

Primary OD (inches).043 .043 .043 .043 .049 .049 .049 .049 .058 .058 .058 .058 .068 .068 .068 .068 .075 .075 .075 .075 .090 .090 .090 .090 .111 .111 .111 .111

Shield OD (inches).059 .102 .109 .120 .065 .114 .122 .135 .074 .132 .141 .156 .084 .152 .163 .181 .091 .166 .178 .198 .109 .196 .210 .234 .127 .238 .256 .289

Cable OD (inches).079 .122 .129 .140 .085 .134 .142 .155 .094 .152 .161 .180 .104 .176 .187 .205 .111 .190 .202 .222 .129 .220 .234 .258 .147 .262 .280 .309

Weight (lbs.)7 13 16 19 10 15 20 25 11 20 27 35 15 28 38 47 17 33 46 59 23 45 65 82 33 68 95 126

Cable configurations of up to 10 primaries are also available. All figures referenced are nominal.

20

MIL-DTL-27500 Type TE-14

Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/16. Identification In accordance with MIL-C-27500 Part NumberMS27500-24TE-1T14 MS27500-24TE-2T14 MS27500-24TE-3T14 MS27500-24TE-4T14 MS27500-22TE-1T14 MS27500-22TE-2T14 MS27500-22TE-3T14 MS27500-22TE-4T14 MS27500-20TE-1T14 MS27500-20TE-2T14 MS27500-20TE-3T14 MS27500-20TE-4T14 MS27500-18TE-1T14 MS27500-18TE-2T14 MS27500-18TE-3T14 MS27500-18TE-4T14 MS27500-16TE-1T14 MS27500-16TE-2T14 MS27500-16TE-3T14 MS27500-16TE-4T14 MS27500-14TE-1T14 MS27500-14TE-2T14 MS27500-14TE-3T14 MS27500-14TE-4T14 MS27500-12TE-1T14 MS27500-12TE-2T14 MS27500-12TE-3T14 MS27500-12TE-4T14

Primary (AWG)24 24 24 24 22 22 22 22 20 20 20 20 18 18 18 18 16 16 16 16 14 14 14 14 12 12 12 12

Stranding (No./AWG)19/36 19/36 19/36 19/36 19/34 19/34 19/34 19/34 19/32 19/32 19/32 19/32 19/30 19/30 19/30 19/30 19/29 19/29 19/29 19/29 19/27 19/27 19/27 19/27 19/28 19/28 19/28 19/28

Primary OD (inches).045 .045 .045 .045 .052 .052 .052 .052 .060 .060 .060 .060 .071 .071 .071 .071 .079 .079 .079 .079 .093 .093 .093 .093 .114 .114 .114 .114

Shield OD (inches).054 .095 .101 .110 .061 .109 .116 .127 .069 .125 .133 .146 .084 .145 .154 .170 .102 .157 .167 .184 .104 .185 .198 .218 .126 .229 .245 .271

Cable OD (inches).072 .113 .119 .128 .079 .127 .134 .145 .087 .143 .151 .164 .102 .163 .178 .194 .120 .181 .191 .208 .122 .209 .222 .242 .144 .253 .269 .295

Weight (lbs.)7 11 15 19 8 15 19 25 10 19 25 32 14 26 36 45 16 31 43 54 22 43 60 76 30 60 86 114

All figures referenced are nominal.

21

MIL-DTL-27500 Type TG-14Applications Used for aerospace flight vehicles. Primary conductors manufactured in accordance to M22759/18. Identification In accordance with MIL-C-27500 Part NumberMS27500-24TG-1T14 MS27500-24TG-2T14 MS27500-24TG-3T14 MS27500-24TG-4T14 MS27500-22TG-1T14 MS27500-22TG-2T14 MS27500-22TG-3T14 MS27500-22TG-4T14 MS27500-20TG-1T14 MS27500-20TG-2T14 MS27500-20TG-3T14 MS27500-20TG-4T14 MS27500-18TG-1T14 MS27500-18TG-2T14 MS27500-18TG-3T14 MS27500-18TG-4T14 MS27500-16TG-1T14 MS27500-16TG-2T14 MS27500-16TG-3T14 MS27500-16TG-4T14 MS27500-14TG-1T14 MS27500-14TG-2T14 MS27500-14TG-3T14 MS27500-14TG-4T14 MS27500-12TG-1T14 MS27500-12TG-2T14 MS27500-12TG-3T14 MS27500-12TG-4T14

Primary (AWG)24 24 24 24 22 22 22 22 20 20 20 20 18 18 18 18 16 16 16 16 14 14 14 14 12 12 12 12

Stranding (No./AWG)19/36 19/36 19/36 19/36 19/34 19/34 19/34 19/34 19/32 19/32 19/32 19/32 19/30 19/30 19/30 19/30 19/29 19/29 19/29 19/29 19/27 19/27 19/27 19/27 19/25 19/25 19/25 19/25

Primary OD (inches).036 .036 .036 .036 .043 .043 .043 .043 .051 .051 .051 .051 .061 .061 .061 .061 .070 .070 .070 .070 .085 .085 .085 .085 .107 .107 .107 .107

Shield OD (inches).054 .095 .101 .110 .061 .109 .116 .127 .069 .125 .133 .146 .084 .145 .154 .170 .090 .157 .167 .184 .104 .185 .198 .218 .126 .229 .245 .271

Cable OD (inches).072 .113 .119 .128 .079 .127 .134 .145 .087 .163 .178 .194 .102 .163 .178 .194 .108 .181 .191 .208 .122 .209 .222 .242 .144 .253 .269 .295

Weight (lbs.)6 9 12 15 7 12 17 20 9 18 22 27 12 23 31 40 15 28 39 72 21 40 56 72 30 59 83 111

All figures referenced are nominal.

22

Mil-C-1 Coaxial Cable 7 QPL ApprovedSingle braid Double braid

Triax

Twinax

Harbour supplies a complete line of high temperature, high performance QPL approved MIL-C-17 coax cables for the military, commercial and industrial applications. The specific M17 constructions referenced are manufactured in accordance with the most recent revision of the MIL-C-17 specification. The MIL-C-17 specification defines complete physical and electrical characteristics for each M17 part number, including dimensional parameters, dielectric materials, shield construction, maximum attenuation, and VSWR levels. VSWR Sweep Testing When selecting a 50 ohm coaxial cable, constructions with VSWR requirements are recommended. Manufacturing and sweep testing cables with concern for VSWR ensures a quality cable free of spikes over the referenced frequency range. (Note the test frequencies specified in the electrical characteristics section.) Precision PTFE Dielectrics All of the high temperature, high performance coax cables listed have PTFE dielectrics with high dielectric strength and low capacitance in proportion to the dielectric constant. All PTFE dielectrics are manufactured with tolerances tighter than the MIL-C-17 specification to ensure uniformity of electrical characteristics, especially impedance, attenuation and VSWR. Tape wrapped PTFE Constructions Harbour also manufactures PTFE tape wrapped cables to a previous revision of the MIL-C-17 specification. These constructions can withstand operating temperatures up to 250 C. versus 200 C. for FEP jacketed cables. Also, PTFE tape wrapped cables are generally more flexible than their FEP jacketed counterparts. UL Approvals All of Harbours M17 part numbers manufactured to the MIL-C-17 specification may be ordered with UL and FT4 approvals.

23

Mil-C-1 Coaxial Cables 7Physical Characteristics:M17 Number Center Conductor PTFE Overall Minimum Operating Weight Dielectric Shield Jacket Diameter Recommended Temp. (C) (lbs./MFT) Diameter Bend Radius.116 .033 .033 .063 .102 .146 .116 .060 .285 .116 .033 .060 .116 .033 .116 .060 .285 .116 .042 SPC(2) SPC SPC FEP FEP PFA .195 .071 .071 .100 .141 .202 .170 .098 .390 .195 .116 .114 .195 .071 .170 .098 .390 .195 .129 1.0 0.4 0.4 0.4 0.7 1.0 0.9 0.5 2.0 1.0 0.6 0.6 1.0 0.4 0.9 0.5 2.0 1.0 0.6 -55 +200 -55 +200 -55 +230 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +200 -55 +230 43.0 6.3 6.3 10.8 19.8 40.0 31.0 11.5 165.0 50.0 15.0 18.5 43.0 6.3 31.0 11.5 165.0 50.0 18.0

Comments

M17/60-RG142 .037 SCCS M17/93-RG178 .0120 / (7 .004)SCCS M17/93-00001 .0120 / (7 .004)SCCS M17/94-RG179 .0120 / (7 .004)SCCS M17/95-RG180 .0120 / (7 .004)SCCS M17/110-RG302 .0253SCCS M17/111-RG303 .037SCCS M17/113-RG316 .0201 / (7 .0067)SCCS M17/127-RG393 .094(7/.0312)SC M17/128-RG400 .0384(19/.008)SC M17/131-RG403 .0120 / (7 .004)SCCS M17/152-00001 .0201 / (7 .0067)SCCS M17/158-00001 M17/169-00001 M17/170-00001 M17/172-00001 M17/174-00001 M17/175-00001 M17/176-00002 .037SCCS .0120 / (7 .004)SCCS .037(SCCS .0201 / (7 .0067)SCCS .094(7/ .0312)SCCS .0384(19/.008)SC .0235 (19/.005)SPA(2)

M17/93-RG178 w/extended temp. range

SPC FEP SPC FEP SPC FEP SPC FEP SPC FEP SPC(2) FEP SPC(2) FEP SPC(2) FEP(2) SPC(2) FEP SPC(2) SPC SPC SPC SPC(2) SPC(2) SPA FEP FEP FEP FEP FEP FEP PFA

Triaxial M17/93-RG178 Double shielded M17/113-RG316 Unswept M17/60-RG142 Unswept M17/93-RG178 Unswept M17/111-RG303 Unswept M17/113-RG316 Unswept M17/127-RG393 Unswept M17/128-RG400 Controlled impedance twinax Flexible, 250 C. rated Flexible, 250 C. rated Flexible, 250 C. rated Flexible, 250 C. rated

PTFE Tape Wrap Jacketed RG Cables RG 187 A/U .0120(7/.004)SCCS RG 188 A/U .0201(7/.0067)SCCS RG 195 A/U .0120(7/.004)SCCS RG 196 A/U .0120(7/.004)SCCS

.063 .060 .102 .034

SPC SPC SPC SPC

PTFE PTFE PTFE PTFE

.100 .100 .141 .067

0.5 0.5 0.7 0.4

-55 +250 -55 +250 -55 +250 -55 +250

10.0 11.0 18.0 6.0

Electrical Characteristics:M17 Number Impedence Capacitance Max. Operating (ohms) (pF/ft) Voltage (RMS)1900 1000 1000 1200 1500 2300 1900 1200 2500 1900 1000 1200 1900 1000 1900 1200 2500 1900 1000 1200 1200 1500 1000

100 MHz5.5 16.0 16.0 3.9 11.0 2.4 4.5 11.5 11.0 -

Maximum attenuation (dB/100ft) @ 400 MHz 1 GHz 3 GHz 5 GHz 10 GHz11.7 33.0 33.0 21.0 17.0 8.0 8.6 21.0 5.0 10.5 37.0 24.0 11.7 33.0 8.6 21.0 5.0 10.5 21.0 21.0 17.0 29.0 19.0 52.0 52.0 15.0 38.0 8.8 17.0 40.0 1.4 38.0 35.0 94.0 94.0 26.0 28.0 58.0 18.0 38.0 75.0 48.0 24.6 50.0 110.0 37.0 78.0 170.0 -

Max. Test/Cut off (Freq-GHz)8.0/32.6 3.0 /110.8 3.0 /110.8 0.4/66.5 0.4/43.8 3.0/29.1 3.0/32.6 3.0/62.3 11.0/13.2 12.4/32.3 0.4/110.8 12.4/62.3 0.40/32.6 0.40/110.8 0.40/32.6 0.40/62.3 0.40/13.2 0.40/32.3 0.40/66.5 3.0/62.3 0.40/43.8 0.40/110.8

M17/60-RG142 50 +/- 2 29.4 M17/93-RG178 50 +/- 2 29.4 M17/93-00001 50 +/- 2 29.4 M17/94-RG179 75 +/- 3 19.4 M17/95-RG180 95 +/- 5 16.4 M17/110-RG302 75 +/- 3 19.4 M17/111-RG303 50 +/- 2 29.4 M17/113-RG316 50 +/- 2 29.4 M17/127-RG393 50 +/- 2 29.4 M17/128-RG400 50 +/- 2 29.4 M17/131-RG403 50 +/- 2 29.4 M17/152-00001 50 +/- 2 29.4 M17/158-00001 50 +/- 2 29.4 M17/169-00001 50 +/- 2 29.4 M17/170-00001 50 +/- 2 29.4 M17/172-00001 50 +/- 2 29.4 M17/174-00001 50 +/- 2 29.4 M17/175-00001 50 +/- 2 29.4 M17/176-00002 77 +/- 7 19.0 PTFE Tape Wrap Jacketed RG Cables RG 187 A/U 75 +/- 3 19.4 RG 188 A/U 50 +/- 2 29.4 RG 195 A/U 95 +/- 5 15.4 RG 196 A/U 50 +/- 2 29.4

58.0

Maximum test frequencies are those as referenced on individual slant sheets of the MIL-C-17 specification.

24

Buying DirectoryMIL-C-17 COAXIAL CABLESwept Unswept

INDUSTRIAL WIRE & CABLETCGT 250C UL AND CSA UL Style AWG Sizes Voltage 5315 #24-#2 300 5288 #24-#8 600 TGGT 250C UL AND CSA UL Style AWG Sizes Voltage 5257 #24-#8 300 5156 #24-#2 600 MG 450C UL and CSA UL Style AWG Sizes Voltage 5128 #22-#4 300 5107 #22-#4/0 600 SLIPSTRIP 450C UL and CSA UL Style AWG Sizes Voltage 5360 #30-#4/0 300 5359 #30-#4/0 600 UL/CSA FEP Wires (AWM) UL/CSA AWG Voltage Temp. C. 3135/I A/B #8-#2 600 200 3127/I A/B #8-#2 600 150 3139/I A #24-#12 600 200 3241/I A/B #24-#14 300 200 3304/n/a #22-#12 10KV 200 3239/TV-15 #24-#10 15KV 150 3239/TV-20 #24-#10 20KV 150 3239/TV-25 #24-#10 25KV 150 3239/TV-30 #24-#10 30KV 150 3239/TV-40 #24-#10 40KV 150 3239/TV-50 #24-#10 50KV 150 UL and CSA LEAD WIRES PTFE STYLES UL/CSA AWG Sizes Voltage Temp. C. 1164/1 A/B #28-#12 300 200 1180/1 A/B #28-#12 300 200 1198/1 A/B #24-#12 300 150 1199/1 A/B #24-#12 600 200 1212/1 A/B #32-#12 n/r 200 1213/1 A/B #32-#12 n/r 200 1371/1 A/B #32-#12 n/r 200 1512/1 A/B #16-#14 n/r 200 1538/1 A/B #32-#12 125 105 1584/1 A/B #30-#12 1000 200 1659/1 A/B #26-#12 600 250 1716/1 A/B #32-#12 150 1500 1815/1 A/B #32-#12 300 250 UL FEP Wires (AWM) UL/CSA AWG Sizes Voltage Temp. C. 1226/I A/B #26-#20 n/r 80 1227/I A/B #26-#14 n/r 105 1330/I A/B #26-#4/0 600 200 1331/I A/B #26-#4/0 600 150 1332/I A/B #36-#10 300 200 1333/I A/B #26-#4/0 300 150 1371/I A/B #26-#6 n/r 105 1538/I A/B #30-#6 125 105 1716/I A/B #30-#6 150 150 ETFE Wires UL/CSA AWG Sizes Voltage Temp. C. 1517/I A/B #24-#20 n/r 105 1586/I A/B #24-#6 n/r 105 1609/I A/B #24-#6 125 105 1610/I A/B #24-#10 n/r 105 1671/I A #30-#10 300 150 10086/I A/B #24-#10 600 200 10109/I A/B #24-#10 300 200 10125/I A/B #30-#4/0 300 150 10126/I A/B #30-#4/0 600 150

M16/60-RG142 M17/93-RG178 M17/93-00001 M17/94-RG179 M17/95-RG180 M17/110-RG302 M17/111-RG303 M17/113-RG316 M17/128-RG400 M17/131-RG403 M17/152-00001 M17/176-00002

M17/158-00001 M17/169-00001 M17/170-00001 M17/172-00001 M17/174-00001 M17/175-00001Commercial Grade

RG 187 A/U RG 188 A/U RG 195 A/U RG 196 A/U RG 393 IMAX

SPECIALTY COAXCommunications Network Coaxial*

CN142 CN316

CN178 CN400

CN179

*Available in single or double braid configurations with Tin Plated Copper or Silver Plated Copper Braid.

Low Loss, High Frequency Coax

LL120 LL142 LL304 LL393-1 LL393-2Low Noise Coax

SB142 SB304 SB393 SB405

SS402 SS405

High Strength Coax

LN178 LN179 LN180

HS178 HS179 HS180

SPECIALTY INDUSTRIAL WIRESFlameguard - 2 hour Fire Rated Heatguard - Temperatures to 1000 C. Hartrex - Resistant to 1000 Megrads SLAR - Nuclear robotics cable

SureformPlus Hand Formable Coax Unjacketed Jacketed

SC401 SC402 SC405

SC401FJ SC402FJ SC405FJ

SC401PJ SC402PJ SC405PJ

High Performance Foam - NEC 800, NEC 820, CMR, Halogenated, Non-Halogen, CATVR

HPF195 HPF240

HPF200 HPF400

Custom designs utilizing the following components are available upon request: SOLID & STRANDED CONDUCTORSBare Copper Grade A Nickel Nickel Plated Copper Nickel Plated High Strength Copper Alloy Nickel Plated Steel Nickel Plated Copper Clad Steel Silver Plated High Strength Copper Alloy Silver Plated Copper Clad Steel Silver Plated Copper Tin Plated Copper Thermocouple Alloys Resistive Alloys Oxygen Free Nickel Plated Copper Oxygen Free Silver Plated Copper Tin Overcoat Copper

PREMISE NETWORKING CABLESPlenum, Coaxial FEP Core

NEC 800, CMP RG-59 RG-58-Thinnet RG-6 100 Ohm Twinax Category 3 XH Category 5e Category 6

RG-62

Local Area Network Cable - PVC & Plenum Rated

Category 5e

SHIELD MATERIALSNickel Plated Copper Nickel Plated Copper Clad Steel Silver Plated Copper Silver Plated Copper Clad Steel Stainless steel Flat Braid Round Braid Spirally Applied Flat Aluminum Polyester Tape Aluminum Polyimide Tape

CL2P, CMP, MMP, FPLP, CSA, FT4, FT6 Low-Cap Mid-Cap Loop Sound and Control Signaling Ethernet Transceiver IEEE 802.3 Point-of-sale cables

Power-limited cables - NEC725, NEC800

INSULATION & JACKETING MATERIALSExtruded Materials ETFEP ECTFE FRPVC FEP PVC PEEK PTFE PVDF PFA TPE Polyethylene Polyimide Polyurethane Silicone Rubbers Tapes Ceramic Fiberglass Mica Polyester PTFE Yarns Aramid Ceramic Fiberglass K-fiber Polyimide Polyester Fiberglass

US 800 659 4733 800 65 WIRED Canada 450 293 5304 www.harbourind.com [email protected]

The UL and CSA styles listed here represent the most commonly requested items. Harbour is approved for many more styles not listed here. If you do not see a particular style that you need call 1 800 659 4733 to check availability.

25

Hook-Up WireMIL-W-16878* Revision F. PTFE InsulationExtruded Insulation

MIL-W-22759 Revision E PTFE Insulation Part No. M22759/9 M22759/10 M22759/11 M22759/12 M22759/20 M22759/21 M22759/22 M22759/23 M22759/5 M22759/6 M22759/7 M22759/8ETFE Insulation

Part No. NEMA HP-3 AWG Size Conductor Voltage Temp. C. M16878/4 E #30-#10 SPC 600 200 M16878/5 EE #30-#8 SPC 1000 200 M16878/6 ET #30-#20 SPC 250 200 M16878/23 ET #30-#20 NPC 250 260 M16878/25 E #22-#12 NPC 600 260 M16878/27 EE #25-#12 NPC 1000 260Wrapped Insulation

M16878/21 M16878/22 M16878/26 M16878/28 M16878/34 M16878/35FEP Insulation

E EE E EE EE EE K KK KT -

#22-#10 #22-#6 #22-#10 #22-#6 #22-#8 #22-#8 #26-#8 #26-#4/0 #26-#20 #24-#10 #24-#4/0 #24-#10 #24-#4/0 #24-#4/0 #24-#4/0

SPC SPC NPC NPC SPC NPC SPC SPC SPC SPC SPC TPC TPC TPC SPC

600 1000 600 1000 1000 1000 600 1000 250 600 1000 600 1000 1000 1000

200 200 260 260 200 260 200 200 200 200 200 150 150 150 200

AWG Size #28-#8 #28-#12 #28-#8 #28-#12 #28-#20 #28-#20 #28-#20 #28-#20 #24-#10 #24-#10 #24-#10 #24-#10 #24-#2/0 #26-#20 #26-#10 #26-#20

Conductor SPC NPC SPC NPC SPTF NPTF SPTF NPTF SPC NPC SPC NPC TPC SPA TPC SPA

Voltage 1000 1000 600 600 1000 1000 600 600 600 600 600 600 600 600 600 600

Temp.C. 200 260 200 260 200 260 200 260 200 260 200 260 150 150 150 150

Mineral Filled PTFE Insulation

M16878/11 M16878/12 M16878/13 M16878/7 M16878/8 M16878/29 M16878/30 M16978/31 M16878/32

M22759/16 M22759/17 M22759/18 M22759/19

Silicone Rubber Insulation

MILITARY/COMMERCIAL CABLESShielded or unshielded, extruded FEP, ETFE or tape wrapped PTFE jackets using the following components: MIL-C-27500 PTFE Insulated Primaries Symbol Primaries LE M22759/9 LH M22759/10 RC M22759/11 RE M22759/12 TK M22759/20 TM M22759/22 TN M22759/23 ETFE Insulated Primaries TE M22759/16 TF M22759/17 TG M22759/18 TH M22759/19 Commercial Cables SE FEP Extruded Jacket STJ PTFE Wrapped Jacket

Silicone Rubber and Fiberglass Insulation

*MIL-W-16878 is obsolete and no longer active. Specification requirements for equivalent constructions are found in NEMA HP-3

AWG Size #28-#8 #28-#12 #28-#8 #28-#12 #28-#20 #28-#20 #28-#20 #26-#2/0 #26-#20 #26-#10 #26-#20

In addition to the referenced Military Specifications, Harbour Industries also manufactures hook-up wire and cables to the following specifications:

Hook-Up Wires (MIL-W-) 8777, 81381, 81822, 47206

Cables (MIL-C-) 7078, 27072, 55021/2B

Other MPD-1506, MPD-1507, MIS-13928, MIS-13929

Harbour Industries, Inc. makes every effort to ensure the accuracy of the information contained in this publication. However, Harbour is not responsible for errors or changes.

US 800 659 4733 800 65 WIRED Canada 450 293 5304 www.harbourind.com e-mail - [email protected]

HarbourI N D U S T R I E SHigh Performance Wire & Cable

26