24
Veterinary Mini Fragment System. Instruments and implants for 1.5, 2.0 and 2.4 plate fixation. Compatible with DCP, LC-DCP and LCP plating systems Cortex and locking screws Instruments for standard and locked plating This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.

Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Veterinary

Mini Fragment System. Instrumentsand implants for 1.5, 2.0 and 2.4 platefixation.

Compatible withDCP, LC-DCP andLCP platingsystems

Cortex and lockingscrews

Instruments forstandard andlocked plating

This publication is not intended fordistribution in the USA.

Instruments and implants approved by the AO Foundation.

Page 2: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments
Page 3: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Table of Contents

Introduction

Product Information

Mini Fragment System 2

Plates 4

Screws 6

Universal Drill Guide Technique 8

Featured Instruments 9

Sets Lists 12

Quick Reference Guide – Instruments 18

Quick Reference Guide – Implants 19

Mini Fragment System DePuy Synthes 1

Page 4: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Mini Fragment System

The Mini Fragment Standard System– Contains the 1.5 mm, 2.0 mm and 2.4 mm implants andrelated instruments required for standard LC-DCP andDCP plating

– Can be upgraded to LCP system

The Standard System consists of:– Mini Fragment Standard Instrument Set (103.522)– Mini Fragment Standard Implant Set (103.527)

The Mini Fragment Locking System– Contains the 2.0 mm and 2.4 mm implants and related instruments required for LCP locked plating

– Locking instruments fit in Graphic Case for Mini FragmentInstrument Set (690.521)

The Locking System consists of:– Mini Fragment Locking Instrument Set (103.523)– Mini Fragment Locking Implant Set (103.528)

Graphic Cases– Cases are organized in general order of use– Compact case sizes fit most tabletop autoclaves– Implant module holds screws and plates– Includes auxiliary bins for storing additional equipment

2 DePuy Synthes Mini Fragment System

Page 5: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Mini Fragment System DePuy Synthes 3

Page 6: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

LC-DCP

DCP

Bone loss observed beneath a full-contact plate

Reduced bone loss beneath a limited-contact plate

Plates

DCP (Dynamic Compression Plate)DCP plate hole– Incorporates an incline in the hole that converts screwcompression into plate translation and compression of thebone fracture

– Accepts conventional screws that may be placed in eitherload or neutral positions, depending on whether interfragment compression is desired (see Universal DrillGuide Technique on page 8 for more detail)

– Allows 25° of longitudinal screw angulation and 7° oftransverse screw angulation

LC-DCP plate hole– The dynamic compression unit (DCU) hole is symmetricaland provides bidirectional compression

– Allows 40° of longitudinal screw angulation and 7° oftransverse screw angulation

– Accepts cortex screws that may be placed in either load orneutral positions, depending on whether interfragmentcompression is desired (see Universal Drill Guide on page8 for more detail)

– Centrally located hole at one end for metaphyseal fracturerepair

Uniform stiffness– Allows smooth contouring of the plate to the bone– Protects plate from localized high bending stress, becauseof the even distribution of stresses over a long distancealong the plate

LC-DCP (Limited Contact Dynamic Compression Plate)Grooved undersurface– Provides limited contact between the plate and bone, reducing the chance for temporary porosis under the plate

– Allows periosteal callus formation at the fracture site

4 DePuy Synthes Mini Fragment System

Page 7: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

E

A

B

C

D

LCP (Locking Compression Plate)– Locking screws create a fixed-angle construct, resulting inangular stability

– Tapered end for submuscular plate insertion, reducing tissue trauma

– Limited-contact plate design reduces plate-to-bone contact, protecting vascularity

LCP plate holes– Dynamic compression unit (DCU) hole allows 40° of longitudinal screw angulation and 7° of transverse screwangulation

– Combi-holes allow placement of cortex screws on oneside or locking screws on the opposite side of each hole

A. Threaded hole section for locking screwsB. Dynamic compression unit (DCU) hole section for standardscrews

C. Locking screw in threaded side of plate holeD. Cortex screw in compression side of plate holeE. Stacked combi-hole at plate end accepts either cortex orlocking screws

Bibliography1. Gasser, R., and S.M. Perren, "Parametric Numerical Design Optimization ofInternal Fixation Plates", 7th Meeting of the European Society of Biomechanics,Aarhus (Denmark), 1990.

2. Klaue, K. and S.M. Perren. Unconventional Shapes of the Plate Cross-Section inInternal Fixation: The Trapezoid Plate. Long Term Study of Bone Reaction in SheepTibiae. Davos, Switzerland: Laboratory for Experimental Surgery, AO/ASIF, 1990.

Mini Fragment System DePuy Synthes 5

Page 8: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Screws

Cortex screws– Used for bicortical fixation in diaphyseal bone– Self-tapping screws are standard in all sets– Non-self-tapping screws are also available in 1.5 mm and2.0 mm (hexagonal drive)

Screw Reference Chart

Thread diameter 1.5 mm 2.0 mm 2.0 mm 2.0 mm 2.4 mm 2.4 mm

Screw type Cortex Cortex Cortex Locking Cortex Locking

Drill bit for 1.1 mm 1.5 mm 1.5 mm 1.5 mm 1.8 mm 1.8 mmthreaded hole

Tap self-tapping self-tapping self-tapping self-tapping self-tapping self-tapping

Drive type 1.5 mm/2.0 mm 1.5 mm/2.0 mm T6 Stardrive T6 Stardrive T8 Stardrive T8 Stardrive Cruciform Cruciform

Locking screws– Used with the locking compression plate (LCP)– Conical, double-lead machine thread on the head locksinto threaded combi-hole or stacked combi-hole in theplate

– Create a fixed-angle construct– Stardrive recess is designed to provide improved torquetransmission to the screw, while retaining the screw with-out the use of a holding sleeve

6 DePuy Synthes Mini Fragment System

Page 9: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

A

B

Screw fixationBicortical cortex screw fixation compresses a plate to thebone, creating friction between the plate and bone to maintain stability. Bicortical screws require two cortices of fixation to achieve stability (Figure A).

Locking screws provide stability and load transfer due to thethreaded connection between the plate and screw, withoutcompression of the plate to the bone (Figure B).

Note: If a combination of a cortex screw and locking screwsis used, a cortex screw should be inserted first to pull theplate to the bone. If a locking screw is used first care shouldbe taken to ensure that the plate is held securely to the boneto avoid spinning of the plate about the bone.

Warning:Synthes implants and instruments are manufactured withproprietary processes that produce superior products tothose created by conventional manufacturing processes.Though other companies may be able to estimate the Synthes general product design, Synthes product dimensionsare proprietary. The precision design of Synthes products isvery important for long-term product function and optimalfit between implants.

Only the finest quality materials are used to manufactureSynthes implants. The metals Synthes uses have been scientifically proven to be of the best biocompatibility andquality available today.

With these features and qualities, the mixing of Synthes implants with the implants from other companies is not rec-ommended. The overall performance may be compromiseddue to differences in design, chemical composition, mechani-cal properties, and quality.

Given these qualities are trade-secret, no competitor of Synthes can make a genuine claim “the same as Synthes”.Combining implants from other companies with Synthes implants could reduce product performance. Consequently, itis strongly recommended to not mix parts from differentmanufacturers.

Mini Fragment System DePuy Synthes 7

Page 10: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Neutral

Compression (load)

Universal Drill Guide Technique

Compression (load) positionCompression is achieved by placing the universal drill guidein the eccentric position, and maintaining the drill guidebody above the plate as shown.

Neutral positionNeutral position is achieved by placing the universal drillguide in the eccentric position, and compressing the drillguide body into the hole.

Note: For illustrative purposes, a combi-hole has been depicted. The same methodology applies to LC-DCP andDCP holes.

8 DePuy Synthes Mini Fragment System

Page 11: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Featured Instruments

312.140 Double Drill Guide 1.5/1.1 For use with 2.0/1.5 LC-DCP plates and

2.0/1.5 LCP plates (1.5 mm cortex screws)

Compression is achieved by placing the drill sleeve in the eccentric position, while the neutral position is achieved byplacing the drill sleeve in the center of the plate hole.

312.181 Double Drill Guide 2.4/1.8, with CenteringCollar

323.200 Universal Drill Guide 2.0 For use with 2.0/1.5 LC-DCP plates,

2.4/2.0 LC-DCP plates and2.0/1.5 LCP plates(2.0 mm cortex screws)

323.202 Universal Drill Guide 2.4 For use with 2.4/2.0 LC-DCP plates and

2.4 LCP plates (2.4 mm cortex screws)

The universal drill guides are the only drill guides which function in all Synthes plate holes.

When a cortex screw is used, a universal drill guide should beused to guide the drill bit. If the screw is intended to achieveinterfragment compression, the universal drill guide shouldbe placed in the load position. If the screw is intended tohold the plate, the universal drill guide should be placed inthe neutral position.

Mini Fragment System DePuy Synthes 9

Page 12: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Featured Instruments

323.034 LCP Drill Sleeve 2.0, with Scale, forDrill Bits B 1.5 mm with marking

– For use with 2.0 mm locking screws – Threads into locking plate for correct

alignment of locking screw with platehole

– Centers drill bits to ensure perpendiculardrilling

– Permits proper mating of locking screwin the threaded portion of the combi-hole

323.029 LCP Drill Sleeve 2.4, with Scale up to 30 mm, for Drill Bits B 1.8 mm

– For use with 2.4 mm locking screws – Threads into locking plate for correct

alignment of locking screw with platehole

– Centers drill bits to ensure perpendiculardrilling

– Permits proper mating of locking screwin the threaded portion of the combi-hole

Technique tip: To prevent cross-threading, turn the LCP drillsleeve counterclockwise until it is properly engaged (a slightclick may be apparent), then turn it guide clockwise.

Note: The LCP drill sleeve can also be used intraoperativelyas a reference for visualizing the projection of a lockingscrew in a given hole.

10 DePuy Synthes Mini Fragment System

Page 13: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

329.921 Bending Pin for LCP Plates 2.0, with thread

329.922 Bending Pin for LCP Plates 2.4 and 2.7, with thread

– Protect threaded hole during contouring – Assist in making bends and twist when

used in pairs

511.776 Torque Limiter, 0.8 Nm, with AO/ASIF Quick Coupling For use with 2.4 mm locking screws

511.777 Torque Limiter, 0.4 Nm, with AO/ASIFQuick CouplingFor use with 2.0 mm locking screws

When inserting a locking screw, a torque limiter is used toensure the appropriate amount of torque is applied, to mini-mize the risk of a locking screw backing out of the plate orcold-welding the screw to the plate.

Mini Fragment System DePuy Synthes 11

Page 14: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Mini Fragment Standard Instrument Set(103.522)

Graphic Case

690.521 Graphic Case for Mini Fragment Instrument Set, without Contents

Instruments

310.110 Drill Bit B 1.1 mm, length 60/35 mm, 2-flute, for Quick Coupling, 2 ea.

310.160 Drill Bit B 1.5 mm, length 110/85 mm, 2-flute, for Quick Coupling

310.190 Drill Bit B 2.0 mm, length 100/75 mm, 2-flute, for Quick Coupling, 2 ea.

310.510 Drill Bit B 1.8 mm, length 100/75 mm, 2-flute, for Quick Coupling

310.530 Drill Bit B 2.4 mm, length 100/75 mm, 2-flute, for Quick Coupling, 2 ea.

310.880 Countersink 1.5 to 2.4, length 52 mm, for Mini Quick Coupling

310.950 Handle with Mini Quick Coupling

311.150 Tap for Cortex Screws B 1.5 mm, length 50/20 mm

311.190 Tap for Cortex Screws B 2.0 mm, length 53/24 mm

311.430 Handle with Quick Coupling, length 110 mm

312.140 Double Drill Guide 1.5/1.1, for No.311.150

312.181 Double Drill Guide 2.4/1.8, with Centering Collar

312.220 Double Drill Guide 2.0/1.5

314.467 Screwdriver Shaft, Stardrive, T8, self-holding

314.670 Screwdriver Shaft 1.5/2.0, cruciform, with Holding Sleeve, length 66 mm, blue

319.006 Depth Gauge for Screws B 2.0 mm and 2.4 mm, measuring range up to 38 mm

319.110 Depth Gauge for Screws B 1.5 and 2.0 mm, measuring range up to 26 mm

319.970 Screw Forceps, self-holding, length 85 mm

323.200 Universal Drill Guide 2.0

323.202 Universal Drill Guide 2.4

329.010 Bending Iron for Plates 1.5 and 2.0, length 130 mm, 2 ea.

VW0803.70.10 Kirschner Wire B 0.8 mm with trocar tip, length 70 mm, Stainless Steel, 10 ea.

Also available313.842 Screwdriver Shaft Stardrive 2.0, short, self-holding, for Mini Quick Coupling

329.020 Bending Iron for LC-DCP 4.5 and DCP 4.5, length 250 mm

VW0603.70.10 Kirschner Wire B 0.6 mm with trocar tip, length 70 mm, Stainless Steel, 10 ea.

12 DePuy Synthes Mini Fragment System

Page 15: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Mini Fragment Locking InstrumentSet (103.523)

Instruments

313.842 Screwdriver Shaft Stardrive 2.0, short, self-holding, for Mini Quick Coupling

323.029 LCP Drill Sleeve 2.4, with Scale up to 30 mm, for Drill Bits B 1.8 mm, 2 ea.

323.034 LCP Drill Sleeve 2.0, with Scale, for Drill Bits B 1.5 mm with marking , 2 ea.

329.921 Bending Pin for LCP Plates 2.0, with thread, 2 ea.

329.922 Bending Pin for LCP Plates 2.4 and 2.7, with thread, 2 ea.

Also available

511.777 Torque Limiter, 0.4 Nm, with AO/ASIF Quick Coupling

511.776 Torque Limiter, 0.8 Nm, with AO/ASIF Quick Coupling

Note: Mini Fragment Instrument Set (103.521) consists ofMini Fragment Standard Instrument Set (103.522) andMini Fragment Locking Instrument Set (103.523) stored inGraphic Case for Mini Fragment Instrument Set (690.521).

Mini Fragment System DePuy Synthes 13

Page 16: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Mini Fragment Standard Implant Set(103.527)

Graphic Case

690.523 Graphic Case for Mini Fragment Standard Implants, without Contents

Standard ImplantsCortex Screws B 1.5 mm, self-tapping, 3 ea. (module will hold 6 ea.)

Length (mm) Length (mm)

VS102.006 6 VS102.010 10

VS102.007 7 VS102.011 11

VS102.008 8 VS102.012 12

VS102.009 9

Cortex Screws B 2.0 mm, self-tapping, 3 ea. (module willhold 6 ea.)

Length (mm) Length (mm)

VS202.006 6 VS202.014 14

VS202.008 8 VS202.016 16

VS202.010 10 VS202.018 18

VS202.012 12 VS202.020 20

Cortex Screws Stardrive B 2.4 mm, self-tapping, 3 ea.(module will hold 6 ea.)

Length (mm) Length (mm)

VS210.008 8 VS210.018 18

VS210.010 10 VS210.020 20

VS210.012 12 VS210.022 22

VS210.014 14 VS210.024 24

VS210.016 16

Mini T-Plate 1.5/2.0

Holes (head) Holes (shaft) Length (mm)

VP1322.04 2 4 35

T-Plate 1.5/2.0

Holes (head) Holes (shaft) Length (mm)

VP1322.08 2 8 62

Acetabular Plate 2.0

Holes

VP2500.06 6

LC-DCP 1.5/2.0

Holes Length (mm)

VP3012.06 6 37

VP3012.07 7 43

VP3012.08 8 49

VP3012.10 10 61

LC-DCP 2.0/2.4

Holes Length (mm)

VP3021.06 6 49

VP3022.08 8 65

VP3022.10 10 81

VP3022.12 12 97

14 DePuy Synthes Mini Fragment System

Page 17: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Also available Cortex Screws B 1.5 mm, self-tapping,(module will hold 6 ea.)

Length (mm) Length (mm)

VS102.013 13 VS102.020 20

VS102.014 14 VS102.022 22

VS102.016 16 VS102.024 24

VS102.018 18

Cortex Screws B 2.0 mm, self-tapping,(module will hold 6 ea.)

Length (mm) Length (mm)

VS202.022 22 VS202.028 28

VS202.024 24 VS202.030 30

VS202.026 26

Cortex Screws B 2.0 mm, self-tapping,(module will hold 2 ea.)

Length (mm) Length (mm)

VS202.032 32 VS202.038 38

VS202.034 34 VS202.040 40

VS202.036 36

Cortex Screws Stardrive B 2.4 mm, self-tapping

Length (mm)

VS210.026 26 (6 each)

VS210.028 28 (6 each)

VS210.030 30 (2 each)

LC-DCP Plates 1.5/2.0

Holes Length (mm) Thickness (mm)

VP3011.04 4 25 1.2

VP3011.05 5 31 1.2

VP3011.06 6 37 1.2

VP3011.07 7 43 1.2

VP3012.09 9 55 1.5

VP3012.12 12 73 1.5

VP3012.14 14 85 1.5

LC-DCP Plates 2.4/2.0

Holes Length (mm) Thickness (mm)

VP3021.04 4 33 1.7

VP3021.05 5 41 1.7

VP3021.07 7 57 1.7

VP3021.08 8 65 1.7

VP3022.09 9 73 2.0

VP3022.14 14 113 2.0

OptionalCortex Screws Stardrive B 2.0 mm, self-tapping

Length (mm)

VS209.006 – 6 –40VS209.040

Mini Fragment System DePuy Synthes 15

Page 18: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Mini Fragment Locking Implant Set(103.528)

Graphic Case

690.524 Graphic Case for Mini Fragment Locking Implants, without Contents

Locking Screws B 2.0 mm, self-tapping, 2 ea.(module will hold 5 ea.)

Length (mm)

VS207.006 6

VS207.008 8

VS207.010 10

VS207.012 12

VS207.014 14

VS207.016 16

VS207.018 18

VS207.020 20

Locking Screws Stardrive B 2.4 mm, self-tapping, T8, 2 ea.(module will hold 5 ea.)

Length (mm)

VS208.008 8

VS208.010 10

VS208.012 12

VS208.014 14

VS208.016 16

VS208.018 18

VS208.020 20

VS208.022 22

VS208.024 24

LCP 1.5/2.0

Holes Length (mm) Thickness (mm)

VP4012.06 6 41 1.5

VP4012.07 7 48 1.5

VP4012.08 8 55 1.5

VP4012.10 10 69 1.5

LCP 2.4

Holes Length (mm) Thickness (mm)

VP4021.06 6 48 1.7

VP4022.08 8 64 2.0

VP4022.10 10 80 2.0

VP4022.12 12 96 2.0

LCP Notched Head T-Plate 2.0

Holes shaft Holes head Length (mm)

VP4312.07 7 2 54

LCP Notched Head T-Plate 2.4

Holes shaft Holes head Length (mm)

VP4322.07 7 2 59

Note: Mini Fragment Implant Set (103.524) consists of MiniFragment Standard Implant Set (103.527) and Mini FragmentLocking Implant Set (103.528) stored in Graphic Case forMini Fragment Implant Set (690.522).

16 DePuy Synthes Mini Fragment System

Page 19: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Also availableLocking Screws B 2.0 mm, self-tapping(module will hold 2 ea.)

Length (mm)

VS207.022 22

VS207.024 24

VS207.026 26

VS207.028 28

VS207.030 30

Locking Screws B 2.4 mm, self-tapping(module will hold 5 ea.)

Length (mm)

VS208.006 6

VS208.026 26

VS208.028 28

VS208.030 30

LCP 1.5/2.0

Holes Length (mm) Thickness (mm)

VP4011.04 4 28 1.2

VP4011.05 5 35 1.2

VP4011.06 6 42 1.2

VP4011.07 7 49 1.2

VP4012.09 9 62 1.5

VP4012.12 12 83 1.5

VP4012.14 14 97 1.5

LCP 2.4

Holes Length (mm) Thickness (mm)

VP4021.04 4 32 1.7

VP4021.05 5 40 1.7

VP4021.07 7 56 1.7

VP4021.08 8 64 1.7

VP4022.09 9 72 2.0

VP4022.14 14 112 2.0

Mini Fragment System DePuy Synthes 17

Page 20: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Quick Reference Guide – Instruments

Mini Fragment Mini Fragment MiniStandard Locking Fragment

Instrument Set Instrument Set Instrument Set(103.522) (103.523) (103.521)

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

Part Number Description

310.110 Drill Bit B 1.1 mm, length 60/35 mm, 2-flute, for Quick Coupling

310.160 Drill Bit B 1.5 mm, length 110/85 mm, 2-flute, for Quick Coupling

310.190 Drill Bit B 2.0 mm, length 100/75 mm, 2-flute, for Quick Coupling

310.510 Drill Bit B 1.8 mm, length 100/75 mm, 2-flute, for Quick Coupling

310.530 Drill Bit B 2.4 mm, length 100/75 mm, 2-flute, for Quick Coupling

310.880 Countersink 1.5 to 2.4, length 52 mm, for Mini Quick Coupling

310.950 Handle with Mini Quick Coupling

311.150 Tap for Cortex Screws B 1.5 mm, length 50/20 mm

311.190 Tap for Cortex Screws B 2.0 mm, length 53/24 mm

312.140 Double Drill Guide 1.5/1.1, for No. 311.150

312.181 Double Drill Guide 2.4/1.8, with Centering Collar

312.220 Double Drill Guide 2.0/1.5

314.670 Screwdriver Shaft 1.5/2.0, cruciform, with Holding Sleeve, length 66 mm, blue

319.006 Depth Gauge for Screws B 2.0 mm and 2.4 mm, measuring range up to 38 mm

319.110 Depth Gauge for Screws B 1.5 and 2.0 mm, measuring range up to 26 mm

319.970 Screw Forceps, self-holding, length 85 mm

323.200 Universal Drill Guide 2.0

323.202 Universal Drill Guide 2.4

329.010 Bending Iron for Plates 1.5 and 2.0, length 130 mm

311.430 Handle with Quick Coupling, length 110 mm

313.842 Screwdriver Shaft Stardrive 2.0, short, self-holding, for Mini Quick Coupling

314.467 Screwdriver Shaft, Stardrive, T8, self-holding

323.029 LCP Drill Sleeve 2.4, with Scale up to 30 mm, for Drill Bits B 1.8 mm

323.034 LCP Drill Sleeve 2.0, with Scale, for Drill Bits B 1.5 mm with marking

329.921 Bending Pin for LCP Plates 2.0, with thread

329.922 Bending Pin for LCP Plates 2.4 and 2.7, with thread

690.521 Graphic Case for Mini Fragment Instrument Set, without Contents

18 DePuy Synthes Mini Fragment System

Page 21: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Part Number Description

VS102.006 – Cortex Screws B 1.5 mm, self-tapping, 6 mm –12 mmVS102.012

VS202.006 – Cortex Screws B 2.0 mm, self-tapping, 6 mm –20 mmVS020.020

VS210.008 – Cortex Screws Stardrive B 2.4 mm, self-tapping, 8 mm –24 mmVS210.024

VP1322.04 Mini T-Plate 1.5/2.0, shaft 4 holes, length 35 mm, Stainless Steel

VP1322.08 T-Plate 1.5/2.0, head 2 holes, shaft 8 holes, length 62 mm, Stainless Steel

VP2500.06 Acetabular Plate 2.0, 6 holes, Stainless Steel

VP3012.06 LC-DCP 1.5/2.0, 6 holes, length 37 mm, thickness 1.5 mm, Stainless Steel

VP3012.07 LC-DCP 1.5/2.0, 7 holes, length 43 mm, thickness 1.5 mm, Stainless Steel

VP3012.08 LC-DCP 1.5/2.0, 8 holes, length 49 mm, thickness 1.5 mm, Stainless Steel

VP3012.10 LC-DCP 1.5/2.0, 10 holes, length 61 mm, thickness 1.5 mm, Stainless Steel

VP3021.06 LC-DCP 2.0/2.4, 6 holes, length 49 mm, thickness 1.7 mm, Stainless Steel

VP3022.08 LC-DCP 2.0/2.4, 8 holes, length 65 mm, thickness 2.0 mm, Stainless Steel

VP3022.10 LC-DCP 2.0/2.4, 10 holes, length 81 mm, thickness 2.0 mm, Stainless Steel

VP3022.12 LC-DCP 2.0/2.4, 12 holes, length 97 mm, thickness 2.0 mm

690.523 Graphic Case for Mini Fragment Standard Implants, without Contents

VS207.006 – Locking Screw B 2.0 mm, self-tapping, 6 mm –20 mmVS207.020

VS208.008 – Locking Screw Stardrive B 2.4 mm, self-tapping, 8 mm –24 mmVS208.024

VP4012.06 LCP 1.5/2.0, 6 holes, length 41 mm, thickness 1.5 mm, Stainless Steel

VP4012.07 LCP 1.5/2.0, 7 holes, length 48 mm, thickness 1.5 mm, Stainless Steel

VP4012.08 LCP 1.5/2.0, 8 holes, length 55 mm, thickness 1.5 mm, Stainless Steel

VP4012.10 LCP 1.5/2.0, 10 holes, length 69 mm, thickness 1.5 mm, Stainless Steel

VP4021.06 LCP 2.4, 6 holes, length 48 mm, thickness 1.7 mm, Stainless Steel

VP4022.08 LCP 2.4, 8 holes, length 64 mm, thickness 2.0 mm, Stainless Steel

VP4022.10 LCP 2.4, 10 holes, length 80 mm, thickness 2.0 mm, Stainless Steel

VP4022.12 LCP 2.4, 12 holes, length 96 mm, thickness 2.0 mm, Stainless Steel

VP4312.07 LCP Notched Head T-Plate 2.0, shaft 7 holes, head 2 holes, length 54 mm, Stainless Steel

VP4322.07 LCP Notched Head T-Plate 2.4, shaft 7 holes, head 2 holes, length 59 mm, Stainless Steel

690.524 Graphic Case for Mini Fragment Locking Implants, without Contents

690.522 Graphic Case for Mini Fragment Implant Set, without Contents

Quick Reference Guide – Implants

Mini Fragment Mini Fragment Mini Standard Locking Fragment Implant Set Implant Set Implant Set (103.527) (103.528) (103.524)

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

Mini Fragment System DePuy Synthes 19

Page 22: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments
Page 23: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments
Page 24: Mini Fragment System. Instruments and implants for 1.5, 2.0 and …synthes.vo.llnwd.net/o16/LLNWMB8/INT Mobile/Synthes... · 2019-08-02 · Veterinary Mini Fragment System. Instruments

Synthes GmbHEimattstrasse 34436 OberdorfSwitzerlandTel: +41 61 965 61 11Fax: +41 61 965 66 00www.depuysynthes.com ©

DePuy Synthes Veterinary, a division of Synthes GmbH. 2018. All rights reserved.

036.000.996

DSEM/VET/1115/0006(1)

06/18

This publication is not intended for distribution in the USA.

All surgical techniques are available as PDF files at www.depuysynthes.com