MKPStainless Steel Magnetic Drive Chemical Process Pump
The sealless MKP magnetic drive pump is ideal to meet the stringent requirements of chemical processing and a multi-tude of other industries. This highly advanced and extremely energy efficient pump is built to handle a huge variety of fluids reliably and absolutely safely.
With its special design using an inverted drive configuration, the MKP requires no plain bearing carrier. The pumped fluid provides optimum lubrication and cooling of the single, centrally located impeller bearing assembly, also allowing solids-laden and low-boiling liquids to be pumped. Depending on the pumped medium, it can handle fluids containing solids in concentrations up to 30% with a particle size up to 1 mm.
The pump impeller rotates stably about a stationary axis on the gyroscopic principle, maintaining a perfect hydraulic balance. This minimises bearing loads, increasing the reliabil-ity of pump operation.
Added to its compact design with virtually no dead areas, the MKP is constructed with just a few, robust components. An intelligent modular system facilitates assembly and keeps the costs of spare parts, maintenance and servicing to a minimum.
The MKP is available in a variety of designs and configurations. In particular, a heat jacketed version allows molten sulphur to be pumped. Its connection dimensions and performance data conform to DIN EN ISO 2858, making the MKP easy to retrofit into any installation to replace old pumps.
Configurations and mounting arrangements
– Close-coupled – Frame-mounted – Horizontal – Vertical – High temperature version – Jacketed – In-line – Baseplate – Bracket
Casing materials
– Stainless steel – Uranus® B6 – Nickel-base alloys, e.g. Hastelloy® B or C – Pure nickel – Titanium
Pump protection
– Containment shell thermocouple – Double-walled containment shell with leakage monitoring – Pt100 temperature probe – Motor load sensor
Processes and fluids
Some typical services include: – Chlor-alkali electrolysis – Refrigeration and heating cycles – Hydrogen peroxide – Molten sulphur – Potassium hydroxide solution – Sulphuric acid
3000 rpm/50 Hz 1500 rpm/50 Hz
1800 rpm/60 Hz3600 rpm/60 Hz
2014
0411
_DO
K_M
KP_F
acts
heet
_en
0403
0-03
© CP Pumpen AG, Switzerland, www.cp-pumps.com
Technical data
Capacities (min./max.) 0.25 to 650 m3/h
Heads (min./max.) 3 to 145 m
Temperatures (min./max.) –100°C to +350°C
Kinematic viscosities 0.5 to 350 mm2/s
Solids concentration up to 30% depending on fluid
Directives and standards
EC Directive 2006/42/EG (Machinery)
EC Directive 94/9/EG (ATEX)
DIN EN ISO 2858
DIN EN ISO 5199
DIN EN ISO 15783
Your CP distributor
MKP 15 A 0
50 Hz Rev. 3 25.02.11 Tf
3000 min-1
1500 min-1
0
20
40
60
80
100
120
140
160
1 10 100 1000
20-1
5-20
020
-15-
160
40-2
5-16
040
-25-
200
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
050
-32-
200
65-4
0-16
065
-40-
200
80-5
0-16
080
-50-
200
125-
80-2
00
0
5
10
15
20
25
30
35
40
1 10 100 1000
20-1
5-20
020
-15-
160
40-2
5-16
040
-25-
200
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
050
-32-
200
65-4
0-16
065
-40-
200
80-5
0-16
080
-50-
200
125-
80-2
00
150-
125-
315
200-
150-
315
100-
65-2
0010
0-65
-160
100-
65-1
6010
0-65
-200
125-
80-2
50
125-
80-2
50
125-
100-
200
125-
100-
200
80-5
0-31
5
125-
80-3
15
80-5
0-31
5
125-
80-3
15
Q [m3/h]
H [m
]H
[m]
Q [m3/h]
MKP 15 A 0
50 Hz Rev. 3 25.02.11 Tf
3000 min-1
1500 min-1
0
20
40
60
80
100
120
140
160
1 10 100 1000
20-1
5-20
020
-15-
160
40-2
5-16
040
-25-
200
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
050
-32-
200
65-4
0-16
065
-40-
200
80-5
0-16
080
-50-
200
125-
80-2
00
0
5
10
15
20
25
30
35
40
1 10 100 1000
20-1
5-20
020
-15-
160
40-2
5-16
040
-25-
200
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
050
-32-
200
65-4
0-16
065
-40-
200
80-5
0-16
080
-50-
200
125-
80-2
00
150-
125-
315
200-
150-
315
100-
65-2
0010
0-65
-160
100-
65-1
6010
0-65
-200
125-
80-2
50
125-
80-2
50
125-
100-
200
125-
100-
200
80-5
0-31
5
125-
80-3
15
80-5
0-31
5
125-
80-3
15Q [m3/h]
H [m
]H
[m]
Q [m3/h]
Follow us on:
MKP 15 A 100
60 Hz Rev. 2 25.02.11 Tf
0
40
80
120
160
200
240
1 10 100 1000
20-1
5-20
020
-15-
160
40-2
5-16
040
-25-
200
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
050
-32-
200
65-4
0-16
065
-40-
200
80-5
0-16
080
-50-
200
125-
80-2
00
0
10
20
30
40
50
60
1 10 100 1000
20-1
5-20
020
-15-
160
40-2
5-16
040
-25-
200
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
050
-32-
200
65-4
0-16
065
-40-
200
80-5
0-16
080
-50-
200
125-
80-2
00
150-
125-
315
100-
65-2
0010
0-65
-160
200-
150-
315
100-
65-2
0010
0-65
-160
125-
80-2
50
125-
100-
200
80-5
0-31
5
125-
80-3
15
80-5
0-31
5
125-
80-3
1512
5-80
-250
125-
100-
200
3600 min-1
1800 min-1
Q [m3/h]
H [m
]H
[m]
Q [m3/h]
MKP 15 A 100
60 Hz Rev. 2 25.02.11 Tf
0
40
80
120
160
200
240
1 10 100 1000
20-1
5-20
020
-15-
160
40-2
5-16
040
-25-
200
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
050
-32-
200
65-4
0-16
065
-40-
200
80-5
0-16
080
-50-
200
125-
80-2
00
0
10
20
30
40
50
60
1 10 100 1000
20-1
5-20
020
-15-
160
40-2
5-16
040
-25-
200
50-3
2-25
0
65-4
0-25
0
80-5
0-25
0
50-3
2-16
050
-32-
200
65-4
0-16
065
-40-
200
80-5
0-16
080
-50-
200
125-
80-2
00
150-
125-
315
100-
65-2
0010
0-65
-160
200-
150-
315
100-
65-2
0010
0-65
-160
125-
80-2
50
125-
100-
200
80-5
0-31
5
125-
80-3
15
80-5
0-31
5
125-
80-3
1512
5-80
-250
125-
100-
200
3600 min-1
1800 min-1
Q [m3/h]
H [m
]H
[m]
Q [m3/h]