Buying a product is simple,Project - is not.
Reason #1 to buy HPE POD “You wants to buy high quality solution
from reputable brand”
MDC – datacenter as a product – factory manufactured datacenter
• Requires NO or minimum special DC construction knowledge needed to buy a POD
• Guaranteed characteristics delivery• Guaranteed budget delivery• Standard service for all the solution
Input Swgr
UPS
IT/Server Loads
Smart GridSubstations Xformer
BackupGenerator
ParallelSwitchgear
Ouput Swgr
PDU
Power MonitoringControl System (PMCS)
…
Cooling
Timeframe of delivery of DC
Reason #2 to buy HPE POD“Short/guaranteed time of delivery and implementation of a datacenter”
Lightning Fast Data Center DeploymentReclaim time and expense. Increase IT responsiveness.
24 months
Just add network and powerFaster deployment — reduced time, cost, risk Eliminate under/over provisioning — pay as you grow approachPlug & Play
4 months
Monolithic Data Center
HPE MDC
Engineering and Design
Engineering Administration
Construction Administration
Facility Construction
Facility Commissioning
IT Implementation
MDC Build and IT Configuration
Facility Commissioning
MDC/IT Implementation
High efficiency & quality of the design
Reason #3 to buy HPE POD“Guaranteed efficiency and high quality design,
made by best engineers”
Intelligently adjusts cooling technology based on IT load and climate
Adaptive Cooling Intelligently Maximizes Efficiency
- PUE from 1.15 up to 1.4, depending on the solution
- High Density in small footprint (space efficiency)
- Easily deployable
- Low maintenance high quality design
• Breakthrough CAPEX savings scale with IT capacity needs• Given example is a kind of extreme high costs for B&M and low for POD. Otherwise the statement is that POD is not
expensive, it is just normal market price
Reasonable price
1MW Break & Mortal Data Center 1MW HPE POD Solution
Up to 75% savings in 1/10 the space
10%
Note: Prices for Brik and Mortal differs dramatically from country and project and could be even ½ of POD based project, depending on the quality and other…
MDC PortfolioOptimized Infrastructure for Multiple Markets
DC8200kW 368U
DC18500kW858U
DC10290kW500U
DC21-600580kW1,050U
DC441,014kW2,200U
DC450kW 200U
DC5-5050kW250U
DC21-300290kW1050U
Mini DCDC1
DC10-200200kW500U
DC20680kW or 880kW
840U
Dual MDC DC10,DC21
Connects 2 x MDC units back-to-backEliminates climate imposed rear access issuesAssembled on siteStandardised components
Units operate independentlySeparate ECS connectionsSeparate water and power connections
15
Adapting standard solutions for maximum growth
Modular built Datacenter – based on HPE MDC modules and HPE MDC infrastructure modules (power and cooling)
1.2/2.4MW modular DC • 3/6 MW modular DC
16
Examples based on 600KW per MDC module (options 100KW, 200KW, 300KW) connected with corridors and MDC power and cooling infrastructure modules
Product with full data center functionality
• Stronger
• Shock and vibration tested• Wide temperature range
– -32°C to +45°C standard– Extendable to -45°C and +55°C
• Robust Steel / Aluminium design• 20 yr+ Lifecycle• Mil specifications on request
(EMC/EMP)• IP44 for outdoor location on
commercial units• CE certification• Fire safety Earthwool Building Slabs
which are classified as Euroclass A1 to BS EN ISO 13505-1, non-combustible to BS 476:Part 4:1970 (1984) and, Class 1 Surface Spread of Flame to BS 476:Part 7:1997 and Class ‘O’ to the Building Regulations.
• Smarter
• Customizable• High density in small footprint• Integrated management
• Simpler
• Rapid Build (14-16 weeks)• Fully tested before shipment• Transportable fully loaded with IT• Easy to deploy with industry
standard connectors• Predefined support, spares and
training• Low Maintenance design
17
Elements of water cooled MDC – Air flow (closed loop)
Hot exhaust air from racks is drawn upwards towards HEX modules
19” Rack Frames
Hot aisleCold aisle
Air Temp up to 30°C
Cold Water Temp between 12°C and 24°C
Heat drawn through HEX modules
Fans push airflow downwards
Power Solutions Genset Switchgear UPS All-in-One
PMU 80Ups 50kW
PMU 150Ups 100kW
PMU 250Ups 150kW
PMU 350200kW
Includes:• UPS N or N+1• Switch gear • Genset• Diesel tank• Environment control system• Arctic kit• Monitoring• …
Cooling solutions
CM1203x40kW
CM1803X60kW
CM6002X300kW
PUMP SKIDDISTRICTCOOLINGBased on:
• Copeland, Bitzer, Stulz• CE or UL compliant
Features and options:• High Temp Kit• Arctic Kit• 100% Eco mode Kit• Buffer tank onboard• 2N on pumps• Distribution secured on UPS feed
CM3603X120kW
Customer Experience Center – Geneva, Switzerland
• 4 x 40ft MDC DC21 Modules with interconnecting corridors for covered access• Used to showcase HPE’s IT solution capabilities• Customer visits welcome
21
Build Datacenter with HPE Modular Datacenter Technology
• Easily• Quickly
• High efficiency and low OPEX• High quality @ reasonable cost• Low risks for DC construction and exploitation
HPE POD deliver