Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
AHNAY SERIESBi-11-350 to Bi-11-395
Superior moduleefficiency as per
internationalbenchmarks
WS09179001025384
Modules binned bycurrent to improve
system performance
Glass with antireflective coating
improves lighttransmission
Salt mist,ammonia, blowing
sand and hailresistant
I-V VARIATION WITH IRRADIANCE
I-V VARIATION WITH TEMPERATURE
The Graphs are for reference purpose only. Please consult Waaree technical team for further clarifications.
www.waaree.com
PID resistantwith long
term reliability
Sustain heavywind & snow loads
(2400 pa & 5400 pa)
Full squareMono PERC
cells
2158.75 mm
0 10 20 30 40
Voltage [V]
0
2
4
6
8
10
12
Curr
ent
[A]
395.3 WIncident Irrad. = 1000 W/m²
Cells temp. = 25 °C
314.1 WIncident Irrad. = 800 W/m²
233.0 WIncident Irrad. = 600 W/m²
152.4 WIncident Irrad. = 400 W/m²
73.2 WIncident Irrad. = 200 W/m²
0 10 20 30 40 50
Voltage [V]
0
2
4
6
8
10
12
Curr
ent
[A]
Incident Irrad. = 1000 W/m²
Cells temp. = 10 °C, Pmpp = 416.8 W
Cells temp. = 25 °C, Pmpp = 395.3 W
Cells temp. = 40 °C, Pmpp = 373.3 W
Cells temp. = 55 °C, Pmpp = 350.7 W
Cells temp. = 70 °C, Pmpp = 327.7 W
ISO 9001:2015 l ISO 14001:2015 l ISO 45001:2018 l IEC 61215-2016^ l UL 61730-1 & 2^Independent assessment of factories by BLACK & VEATCH
ELECTRICAL CHARACTERISTICS
www.waaree.com
Waaree Energies Ltd. is amongst the top Solar Energy Companies and has the country's largest Solar PV Module manufacturing capacity of 2 GW. In addition, it is committed to provide top notch EPC services, project development, rooftop solutions, solar water pumps and also in an Independent Power Producer. Waaree has its presence in over 325+ locations nationally and 68 countries globally.
*If you need specific product certificates, and if module installations are to deviate from our guidance specified in our installation manual, please contact your local Waaree sales and technical representatives.
Power Output (W)
Module Efficiency (%)
Power Output (W)
Module Efficiency (%)
Power Output (W)
Module Efficiency (%)
Power Output (W)
Module Efficiency (%)
15%
20%
25%
30%
BI-FACIAL OUTPUT BACKSIDE POWER GAIN
Bi-11-350 to Bi-11-395
Bi-11-350
402.50
20.14
420
21.01
438
21.89
455
22.76
Bi-11-355
408.25
20.42
426
21.31
444
22.20
461.5
23.09
Bi-11-360
414
20.71
432
21.61
450
22.51
468
23.41
Bi-11-365
419.75
21.00
438
21.91
456
22.82
474.5
23.74
Bi-11-370
425.50
21.29
444
21.21
463
23.14
481
24.06
Bi-11-375
431.25
21.57
450
22.51
469
23.45
487.5
24.39
Bi-11-380
437
21.86
456
22.81
475
23.76
494
24.71
Bi-11-385
442.75
22.15
462
23.11
481
24.07
500.5
25.04
Bi-11-390
448.50
22.44
468
23.41
488
24.39
507
25.36
Bi-11-395
454.25
22.72
474
23.71
494
24.70
513.5
25.69
10 Years Product Warranty* • Power Output Warranty**25 Years Minimum 90% at the end of 10 years • Minimum 80% at the end of 25 years
ModelsPmax (W)
Bi-11-350
Bi-11-355
Bi-11-360
Bi-11-365
Bi-11-370
Bi-11-375
Bi-11-380
Bi-11-385
Bi-11-390
Bi-11-395
STC NOCT
350
355
360
365
370
375
380
385
390
395
Vmp (V)
STC NOCT
Imp (A)
STC NOCT
Isc (A)
STC NOCT
Voc (V)
STC NOCTModule Eff. (%)
38.53
38.80
39.07
39.34
39.60
39.85
40.11
40.36
40.61
40.88
9.09
9.16
9.23
9.30
9.37
9.43
9.50
9.56
9.62
9.69
9.58
9.64
9.71
9.77
9.84
9.90
9.97
10.03
10.09
10.16
46.77
47.09
47.41
47.72
48.04
48.35
48.67
48.98
49.29
49.62
17.51
17.76
18.01
18.26
18.51
18.76
19.01
19.26
19.51
19.76
258.4
262.2
266.1
268.8
273.4
277.2
280.9
284.6
288.3
292.1
35.27
35.54
35.80
36.06
36.30
36.55
36.79
37.04
37.29
37.52
7.32
7.37
7.43
7.48
7.53
7.58
7.63
7.69
7.73
7.78
7.75
7.80
7.86
7.90
7.96
8.00
8.06
8.11
8.16
8.22
43.18
43.46
43.76
44.04
44.33
44.62
44.91
45.11
45.48
45.78
• The electrical data given here is for reference purpose only.• Please confirm your exact requirements with the sales representative while placing your order.• Refer installation Manual instructions & Waaree warranty statement for terms & conditions.• Waaree Reserves the right to change the specifications without prior notice.
*Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%.
(^) Certications Under progress
MECHANICAL CHARACTERISTICS
Length x Width x Thickness (LxWxT)
Weight
Solar Cells per Module (Units)/Arrangement
Solar Cell Type & Size
Front Glass
Encapsulate
Junction Box (Protection degree/Material)
Cable & Connector (Protection degree/Type)
Cable cross - section & Length
THERMAL CHARACTERISTICS
Temperature coefficient of Current
(Isc), α (%/ºC)
Temperature coefficient of Voltage
(Voc), ß (%/ºC)
Temperature coefficient of Power
(Pm), γ (%/ºC)
NOCT (ºC)
Operating temperature range (ºC)
0.05
-0.27
-0.37
46 ± 2
-40 to 85
2002 mm (L) x 998.5 mm (W) x 6.5 mm (T)
28 kgs
72 cells / (12x6)
158.75 x 158.75 mm Mono PERC Bifacial,
empered glass with2.5mm Low Iron and T
ARC coating
PID Free & UV Resistant
IP68 / Weatherproof PPO
IP68 rated / MC4 compatible24 mm & 500mm
System Voltage Series Fuse Rating1500 V 20 A
AHNAY SERIES