4
For a diverse range of applications which call for a high level of ingress protection, Moduseal 2 offers a complete solution. Moduseal 2 is protected to IP65 from below in a choice of recessed and surface bodies. The clean lines of the diffusers and frames offer greater control of choice of T5 linear, T5 linear economy and LED for maximum energy efficiency. T5 versions are prismatic panel or louvred. Louvred options comply with the luminance limits given in EN12464-1. An integrated LED emergency option gives a highly efficient design solution, minimising installation points. IP65 dust tight and water jet proof from below – IP54 rear body Surface versions are IP65 throughout Minimalist extruded frame with fixtureless mounting Easily wiped down diffuser assemblies for hygiene All diffusers are TPa and can be used within emergency exit routes Integrated emergency optic for high performance design solutions Recessed body options are suitable for a wide range of ceiling integration including prepared apertures. Recessed Moduseal 2 1

Moduseal 2 - Cooper Lighting & · PDF fileversions are prismatic panel or louvred. ... Light Source and Control Gear Options • LED ... or email [email protected]

  • Upload
    ngodiep

  • View
    218

  • Download
    1

Embed Size (px)

Citation preview

For a diverse range of applications which call for ahigh level of ingress protection, Moduseal 2 offers acomplete solution.

Moduseal 2 is protected to IP65 from below in achoice of recessed and surface bodies. The cleanlines of the diffusers and frames offer greatercontrol of choice of T5 linear, T5 linear economyand LED for maximum energy efficiency. T5versions are prismatic panel or louvred. Louvredoptions comply with the luminance limits given inEN12464-1. An integrated LED emergency optiongives a highly efficient design solution, minimisinginstallation points.

IP65 dust tight and water jet proof from below•– IP54 rear body

Surface versions are IP65 throughout•

Minimalist extruded frame with fixtureless•mounting

Easily wiped down diffuser assemblies for•hygiene

All diffusers are TPa and can be used within•emergency exit routes

Integrated emergency optic for high•performance design solutions

Recessed body options are suitable for a wide•range of ceiling integration including preparedapertures.

RecessedModuseal 2

1

RecessedModuseal 2

Light Source and Control Gear Options

LED – high output, high efficiency LED chip set optimized•for maximum efficiency

Energy efficient LED drivers and high frequency T5 control•gear as standard

T5 fluorescent – luminaires optimized for maximum•efficacy with a choice of HO and HE lamps (suppliedminus lamps)

Options

Fully integrated LED emergency conversion with optic•lens, 3 hour duration

Suitable for use on defined escape routes•

We offer a range of product support contracts to aid•commissioning, reduce your maintenance costs, complywith legislative test requirements and increase thelifespan of your lighting equipment

Luminaire end detail and emergency LED - recessed T5 louvre End detail - surface mount T5 prismatic - IP65

1200 x 300 surface mount T5 - IP65 1200 x 600 recessed T5 prismatic - IP65/IP54

Diffuser frame removal tool - MS2RST Exploded view - 600 x 600 T% louvre - recessed

2

3

RecessedModuseal 2

Materials

Body – welded, full box steel construction, powder coated•RA9016 white

IP65 Frame – extruded aluminium, chromate pretreated and•powder coated RAL 9016 white

LED panel – TPa rated opal material•

T5 panel – TPa rated prismatic material•

Louvre assembly – MIRO 6 satin aluminium and clear TPa•polycarbonate panel

Surface mounted body – welded, full box steel construction,•powder coated RA9016 white

Installation notes

For ceiling type compatibility refer to the installation guide on•page 74

Contact Eaton’s Technical Support team for compatibility with•other ceilings

May be used with prepared aperture ceilings which are•suitably reinforced – see the diagram below for details

Terminal block with a 2 x 2.5mm2 cable capacity per•termination

Fixtureless frame retention can be removed with supplied•tool or diffuser frame removal tool MS2RST

MS2RST not suitable for prismatic T5 versions, use the•supplied tool only.

Specification

To specify state: Modular recessed luminaire, IP65/IP54 full boxwelded construction body with post coat powder paint, TPa PVCprismatic lens/MIRO 6 louvre and TPa clear polycarbonate panel /TPa opal in extruded aluminium frame with RAL9016 finish,securely fixed and with gaskets to achieve IP65/IP54 from belowceiling/ IP65 surface mounted. LED emergency option with iniquelens optic delivering up to 10m x 10m distribution, as Eaton’sModuseal range, part no. ________

Dimensions

Photometric Data

�) ), ),

�+,�+,

�),�),

-+,-+,

.),.),

*)+,*)+,

))

))

/0'�1

SHR nom: 1.50SHR max: 1.555LO 3636 lm

Cat. No. MS2R364Z

�( (* (*

�)*�)*

+(*+(*

,)*,)*

-(*-(*

�()*�()*

�((

�)(

((

./&�0

SHR nom: 1.50SHR max: 1.589

Cat. No. MS2R314Z

Utilisation factors / TM5Reflectances Room Index C W F 0.75 1.0 1.25 1.5 2.0 2.5 3.0 4.0 5.0 70 50 20 61 69 77 82 89 93 97 101 104 70 30 20 53 62 69 75 83 88 92 97 100 70 10 20 48 56 64 70 78 84 88 94 97 50 50 20 59 67 74 79 86 90 93 97 100 50 30 20 53 61 68 73 81 85 89 94 97 50 10 20 48 56 63 69 76 82 86 91 94 30 50 20 58 65 72 76 83 87 90 93 96 30 30 20 52 59 67 72 78 83 86 91 94 30 10 20 47 55 62 68 75 80 83 88 91 0 0 0 45 53 60 65 71 76 79 84 87 BZ-class 4 4 4 4 4 4 4 4 4

Utilisation factors / TM5Reflectances Room Index C W F 0.75 1.0 1.25 1.5 2.0 2.5 3.0 4.0 5.0 70 50 20 40 46 51 54 59 62 65 67 69 70 30 20 35 41 46 50 55 59 61 65 67 70 10 20 32 37 43 46 52 56 59 62 65 50 50 20 39 45 49 53 57 60 62 65 67 50 30 20 35 40 45 49 54 57 59 63 65 50 10 20 32 37 42 46 51 54 57 61 63 30 50 20 38 43 48 51 55 58 60 62 64 30 30 20 34 39 44 48 52 55 58 61 63 30 10 20 31 36 41 45 50 53 56 59 61 0 0 0 30 35 40 43 48 51 53 56 58 BZ-class 4 4 4 4 4 4 4 4 4

�&(&*(&*

)* )*

+&*+&*

,)*,)*

-&*-&*

'&)*'&)*

'&&

')&

&&

)&

(&&

./$�0

SHR nom: 1.50SHR max: 1.649

Cat. No. MS2R414ZUtilisation factors / TM5Reflectances Room Index C W F 0.75 1.0 1.25 1.5 2.0 2.5 3.0 4.0 5.0 70 50 20 48 54 58 61 65 67 69 71 72 70 30 20 44 50 54 57 62 65 66 69 71 70 10 20 41 47 51 55 59 62 64 67 69 50 50 20 47 52 56 59 63 65 66 68 70 50 30 20 43 49 53 56 60 63 65 67 68 50 10 20 41 46 51 54 58 61 63 65 67 30 50 20 46 51 55 58 61 63 64 66 67 30 30 20 43 48 52 55 59 61 63 65 66 30 10 20 41 46 50 53 57 60 61 64 65 0 0 0 39 44 49 51 55 57 59 61 62 BZ-class 1 2 2 1 1 1 1 1 1

W

D

L

W

D

L

X X X

N

B

A

A

B

X X X

W1

L1

L1

W1

Variant L (mm) W (mm) D (mm) A (mm) B (mm)

T5

2 x 28/54W 1200 300 75 1044 186

4 x 14/24W 600 600 75 420 420

4 x 28/54W 1200 600 75 1044 420

LED

3600/4800lm 600 600 75 420 420

3800/5600lm 1200 300 75 1044 186

Variant L (mm) W (mm) D (mm) A (mm) B (mm) L1 (mm) W1 (mm)

T5

2 x 28/54W 1198 298 75 1176 276 1176 276

4 x 14/24W 598 598 75 576 576 576 576

4 x 28/54W 1198 598 75 1176 576 1176 576

LED

3600/4800lm 598 598 75 576 576

3800/5600lm 1198 298 75 1176 276

NOTE: Drill desiredcable entry hole (wheremarked ‘X’) from theinside of the fitting out.Entry points are spaced40mm equally about thecentre line and 82.2mmfrom the edge

Cable entry gland holes.Entry points are spaced40mm equally about thecentre line and 57mmfrom the edge

RecessedSurface

Prepared aperture

4

RecessedModuseal 2

Catalogue Numbers

Lamp rating Cat no Weight (kg) LED emergency Weight (kg)

600 x 600

3 x 14W MS2R314Z 6.6 EBMS2R314Z 7.1

4 x 14W MS2R414Z 6.6 EBMS2R414Z 7.1

3 x 24W MS2R324Z 6.6 EBMS2R324Z 7.1

4 x 24W MS2R424Z 6.6 EBMS2R424Z 7.1

1200 x 300

2 x 28W MS2R228Z 7.5 EBMS2R228Z 8.0

2 x 54W MS2R254Z 7.5 EBMS2R254Z 8.0

1200 x 600

4 x 28W MS2R428Z 12.6 EBMS2R428Z 13.1

4 x 54W MS2R454Z 12.6 EBMS2R454Z 13.1

Variant Cat NoLumenoutput

Wattage(W) Llm/cW

Weight(kg) Emergency cat no

Weight(kg)

600 x 600

3600 MS2R364KZ 3636 40 90.9 7.0 ELMS2R364KZ 7.5

4800 MS2R484KZ 4824 55 87.7 7.0 ELMS2R484KZ 7.5

1200 x 300

3800 MS2R384KZ 3539 48 73.7 7.9 ELMS2R384KZ 8.4

5600 MS2R564KZ 5608 81 69.2 7.9 ELMS2R564KZ 8.4

Lamp rating Cat no Weight (kg) LED emergency Weight (kg)

600 x 600

4 x 14W MS2RL414Z 7.6 EBMS2RL414Z 8.1

4 x 24W MS2RL424Z 7.6 EBMS2RL424Z 8.1

1200 x 300

2 x 28W MS2RL228Z 8.5 EBMS2RL228Z 9.0

2 x 54W MS2RL254Z 8.5 EBMS2RL254Z 9.0

1200 x 600

4 x 28W MS2RL428Z 14.6 EBMS2RL428Z 15.1

4 x 54W MS2RL454Z 14.6 EBMS2RL454Z 15.1

LED

T5 Prismatic Panel

T5 Louvre

Surface mounted versions are to be ordered complete only. Recessed variants cannot be upgraded to Surface Mounted

For Surface Mounted versions replace character R with S , e.g. MS2S364KZ

For DALI Dimming option replace character Z with DD , e.g. MS2R364KZ becomes MS2R364KDD

For DALI EM PRO emergency options replace add character P as a suffix, e.g. MS2R36KDD becomes MS2R364DDP

Emergency versions also available with automatic test functionality, e.g. EasiCheck 2

For further information, contact our Technical Support and Application department on 01302 303240

or email [email protected]

Llm/cW = luminaire lumens per circuit watt

Surface Mounted

Accessories

Description Cat no

Diffuser frame removal tool MS2RST