4
MPL series “S” MPL 38S Max Power 37,5 kVA MPL 50S Max Power 50 kVA Standard version Version with Site tow Version with 250 lt. Fuel tank with retention bund and fork lift channels (1) Stand-by power: power available for emergency (2) Prime power: maximum power available at variable loads for an unlimited numbers of hours MPL 38S MPL 50S a.c. output 480 V stand-by (1) 37,5 kVA 50 kVA 60 Hz 3~ prime (2) 35,7 kVA 48 kVA power factor fuel starting alternator engine type F4M 2011 BF4M 2011 intake natural turbo cooling displacement c.c. cylinders prime power HP 47 62 RPM tank capacity lt. 3/4 load operating hours h 9,5 7,5 sound power level LwA 96 96 acoustic pressure at 7 mt. dB(A) 71 71 4 1800 65 0,8 Diesel Oil 3108 Deutz Synchronous Electric MASE GENERATORS S.p.a. Via Tortona, 345 47522 Cesena (FC) Italy Tel.+39-0547-354311 Fax.+39-0547-317555 Email : [email protected]

MPL 38S MPL 50S series “S” Max Power 37,5 kVA Max Power 50 … 38-50 eng_60Hz.pdf · MASE GENERA TORS S.p.A. V ia Tortona, 345 .0 del 26 -09-2013 47522 Cesena (FC) Italy Tel.+39-0547-35431

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MPL 38S MPL 50S series “S” Max Power 37,5 kVA Max Power 50 … 38-50 eng_60Hz.pdf · MASE GENERA TORS S.p.A. V ia Tortona, 345 .0 del 26 -09-2013 47522 Cesena (FC) Italy Tel.+39-0547-35431

MPLseries “S”

MPL 38SMax Power 37,5 kV A

MPL 50SMax Power 50 kV A

Standardversion

Version withSite tow

Version with250 lt. Fuel tankwith retentionbund and forklift channels

(1) Stand-by power:power available for emergency

(2) Prime power: maximum power availableat variable loads for an unlimited numbers ofhours

MPL 38S MPL 50Sa.c. output 480 V stand-by(1) 37,5 kVA 50 kVA

60 Hz 3~ prime (2) 35,7 kVA 48 kVA power factor

fuelstarting

alternator

enginetype F4M 2011 BF4M 2011intake natural turbocoolingdisplacement c.c.cylindersprime power HP 47 62RPM

tank capacity lt.3/4 load operating hours h 9,5 7,5

sound power level LwA 96 96acoustic pressure at 7 mt. dB(A) 71 71

4

1800

65

0,8

Diesel

Oil3108

Deutz

Synchronous

Electric

MASE GENERATORS S.p.a. Via Tortona, 345 47522 Cesena (FC) ItalyTel.+39-0547-354311 Fax.+39-0547-317555 Email : [email protected]

Page 2: MPL 38S MPL 50S series “S” Max Power 37,5 kVA Max Power 50 … 38-50 eng_60Hz.pdf · MASE GENERA TORS S.p.A. V ia Tortona, 345 .0 del 26 -09-2013 47522 Cesena (FC) Italy Tel.+39-0547-35431

MPL 38S l MPL 50S

2200

1190

900

1313

3180 1420

1455

2200

1415

900

Standardversion

Version withSite tow

Version with250 lt fuel tank

MPL 38S MPL 50S920 kg 950 kg

MPL 38S MPL 50S1020 kg 1050 kg

MPL 38S MPL 50S1130 kg 1160 kg3/4 load oper .hours 37h 29h

A.A

. R

ev.0

del

26

-09-

2013

MASE GENERATORS S.p.A. Via Tortona, 34547522 Cesena (FC) Italy

Tel.+39-0547-354311 Fax.+39-0547-317555Email : [email protected]

www.masegenerators.com

Dealer:

Page 3: MPL 38S MPL 50S series “S” Max Power 37,5 kVA Max Power 50 … 38-50 eng_60Hz.pdf · MASE GENERA TORS S.p.A. V ia Tortona, 345 .0 del 26 -09-2013 47522 Cesena (FC) Italy Tel.+39-0547-35431

CONTROL PANELS

Standard manual control panel

� Control panel

� Power cubicle with door

� Power cables - terminal board� Cover for power cables - terminal board

CONTROL PANEL

POWER CUBICLE

� Start/stop key� Operation and Alarms� Ammeter� Voltmeter� Hourmeter� Fuel level gauge � Circuit breaker

� Power cables - terminal board� Connection for remote

starting panel

OPTIONAL : Earth fault device

� Emergency stop button

Page 4: MPL 38S MPL 50S series “S” Max Power 37,5 kVA Max Power 50 … 38-50 eng_60Hz.pdf · MASE GENERA TORS S.p.A. V ia Tortona, 345 .0 del 26 -09-2013 47522 Cesena (FC) Italy Tel.+39-0547-35431

OPTIONAL: Automatic st arting

� Fuel level gauge

� Circuit breaker

Digital Genset Control

Automatic T ransferSwitch in a separate

box

� Automatic test� n° 20 alarms� n° 9 genset parameters

� n° 30 programming keys� n° 4 operating mode

OPTIONAL :

Remote control panel with 50 mt. cable

Water heater

Automatic top-up device for on-board tank with retention bundA

.A.

Rev

.0 d

el 2

6 -0

9-20

13

MASE GENERATORS S.p.A. Via Tortona, 34547522 Cesena (FC) Italy

Tel.+39-0547-354311 Fax.+39-0547-317555Email : [email protected]

www.masegenerators.com

Dealer: