8
GRUNDFOS DATA BOOKLET MQ Self-priming multistage pumps 60 Hz

MQ – DATA BOOKLET - · PDF file4 General data MQ Control panel Operation of the MQ pump is effected entirely via the control panel. Fig. 1 MQ control panel Installation Self-cooling

  • Upload
    vuliem

  • View
    219

  • Download
    4

Embed Size (px)

Citation preview

Page 1: MQ – DATA BOOKLET - · PDF file4 General data MQ Control panel Operation of the MQ pump is effected entirely via the control panel. Fig. 1 MQ control panel Installation Self-cooling

GRUNDFOS DATA BOOKLET

MQ

Self-priming multistage pumps60 Hz

Page 2: MQ – DATA BOOKLET - · PDF file4 General data MQ Control panel Operation of the MQ pump is effected entirely via the control panel. Fig. 1 MQ control panel Installation Self-cooling

2

Contents

General dataApplications 3Type key 3Pumped liquids 3Operating conditions 3Technical data 3Features and benefits 3Control panel 4Installation 4Product range 4

Technical dataMaterial specification 5Performance curves 6Dimensions 6Technical data 6

Page 3: MQ – DATA BOOKLET - · PDF file4 General data MQ Control panel Operation of the MQ pump is effected entirely via the control panel. Fig. 1 MQ control panel Installation Self-cooling

MQGeneral data

ApplicationsThe MQ pump is designed for water supply and pressure boosting

• in private homes• in summer houses and weekend cottages• on farms as • in market gardens and other large gardens.The pump is suitable for pumping of potable water and rainwater.

Type key

Pumped liquidsPotable water, rainwater or other clean, thin, non-aggressive liquids, not containing solid particles or fibres.

Operating conditionsSystem pressure: Max. 109 psi (7.5 bar)

Inlet pressure: Max. 44 psi (3 bar)

Suction lift: Max. 26 ft (8 m)

Liquid temperature: 32 °F to +95 °F (0 °C to +35 °C)

Ambient temperature: 32 °F to +113 °F (0 °C to +45 °C).

Technical dataMains voltage: 1 x 110-120 V, 60 Hz

1 x 220-240 V, 60 Hz

Voltage tolerances: – 10 % / + 6 %

Enclosure class: IP 54

Insulation class: B

Sound pressure level: ≤ 55 dB(A)

Marking: CE.

Features and benefits• Complete system

The MQ is a complete, all-in-one unit, incorporating pump, motor, diaphragm tank, pressure and flow sensor, controller and non-return valve.The controller ensures that the pump starts automatically when water is consumed and stops automatically when the consumption ceases. In addition, the controller protects the pump in case of faults.

• InstallationDue to its compact design, the pump does not take up much space and is easy to install. No space around the pump is required.

• Simple operationThe pump features a user-friendly control panel with On/Off button and indicator lights for indication of the operational state of the pump.

• Self-priming pumpAs it is self-priming, the MQ is able to pump water from a level below the pump. Provided it is filled with water, the pump is able to lift water from a depth of 8 m in less than 5 minutes. This facilitates installation and start-up of the pump and provides more reliable water supply in installations where there is a risk of dry running and leakages in suction hose or pipes.

• Built-in protective functionsIf exposed to dry running or excessive temperature, for example in case of seizure or overload, the pump will stop automatically, thus preventing a motor burnout.

• Automatic resetThe pump features an automatic reset function. In case of dry running or similar alarm, the pump will stop. Restarting will be attempted every 30 minutes for a period of 24 hours. The reset function can be deactivated.

• Low noise levelThanks to its hydraulic design and internal cooling, the pump is extremely low-noise, which makes it suitable for both indoor and outdoor use.

• Pressure tankThe built-in pressure tank reduces the number of starts and stops in case of leakages in the pipe system, causing less wear on the pump.

• MaintenanceNo maintenance of the pump is required.

Example MQ 3 -35 A -O -A - BVBPPump range

Rated flow [m3/h]

Maximum head [m]

Code for pump version A: Standard

Code for pipework connection O: External thread

Code for materialsA: Standard

Code for shaft seal

3

Page 4: MQ – DATA BOOKLET - · PDF file4 General data MQ Control panel Operation of the MQ pump is effected entirely via the control panel. Fig. 1 MQ control panel Installation Self-cooling

4

General data MQ

Control panelOperation of the MQ pump is effected entirely via the control panel.

Fig. 1 MQ control panel

InstallationSelf-cooling, compact and horizontal, the pump is well suited for installations where space is limited.

In addition, the pump discharge is flexible, ± 5 °, to facilitate connection to existing pipework.

The pump is supplied complete with a 2 m cable.

Product range

TM01

968

4 26

00

Pos. Function Description

1 On/Off button The pump is started and stopped with the On/Off button.

2Indicator light for mains connection (green)

Indicates that the pump is ready for operation.

3Indicator light for mains connection (red)

Indicates that the pump is on standby.

4 Pump on (green) Indicates that the pump is running.

5 Auto reset (green)

Indicates that the auto reset function is active. After an alarm, restarting will be attempted every 30 minutes for a period of 24 hours.

6 Alarm (red)Indicates that the pump is in alarm state. Manual resetting is possible by pressingthe On/Off button.

21

4 3

56

Region Pump type Voltage Cable Product number

North America, Canada and Mexico

MQ 3-351 x 110-120 V

None 96515512MQ 3-45 None 96515513MQ 3-35

1 x 220-240 VNone 96515514

MQ 3-45 None 96515515

Other 60 Hz markets

MQ 3-351 x 110-120 V

2 m 96515516MQ 3-45 2 m 96515517MQ 3-25

1 x 220-240 V2 m 96515521

MQ 3-35 2 m 96515518MQ 3-45 2 m 96515519

Page 5: MQ – DATA BOOKLET - · PDF file4 General data MQ Control panel Operation of the MQ pump is effected entirely via the control panel. Fig. 1 MQ control panel Installation Self-cooling

MQTechnical data

Material specification

Fig. 2 Sectional drawing of MQ

Pos. Component Material2 Motor stool with base plate POM + 25 % glass fibre4 Chamber PPO + 20 % glass fibre7 Drain and priming plug POM + 25 % glass fibre

10 Self-priming valve PP + 30 % glass fibre14 Self-priming part PPE/PS + 20 % glass fibre

16 Pump sleeve Stainless steel, DIN W.-Nr. 1.4301, AISI 304

42 Pressure tank Butyl (diaphragm)49 Impeller PPO + 20 % glass fibre and PTFE65 Non-return valve POM + 25 % glass fibre

92 Clamp Stainless steel, DIN W.-Nr. 1.4301, AISI 304

100a Discharge port POM + 25 % glass fibre101 Suction port POM + 25 % glass fibre103104

Shaft seal: Stationary and rotating parts Carbon/ceramics/NBR rubber

150Shaft Stainless steel,

DIN W.-Nr. 1.4005, AISI 416

Motor sleeve Stainless steel, DIN W.-Nr. 1.4301, AISI 304

174a Pressure switch184 Flow sensor

O-rings NBR rubber

TM01

973

3 50

06

101 49 16 4 2

100a

14

7

92

150

184 174a 42

103104

65

10

5

Page 6: MQ – DATA BOOKLET - · PDF file4 General data MQ Control panel Operation of the MQ pump is effected entirely via the control panel. Fig. 1 MQ control panel Installation Self-cooling

6

Technical data MQ

Performance curves

Dimensions Technical data

TM01

967

9 41

03

0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Q [m³/h]

0

20

40

60

80

100

120

140

[ft]H

0 4 8 12 16 Q [US GPM]

0

20

40

60

[psi]p

0

8

16

24

32

40

[m]H

MQ 360 Hz

ISO 9906 Annex A

-25

-45

-35

0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Q [m³/h]

0.0

0.2

0.4

0.6

0.8

1.0

P1[kW]

0.0

0.4

0.8

1.2

[hp]P1

0

5

10

15

20

25

[%]Eta

-25 P1Eta

-45 P1-35 P1

The curves shown correspond to a suction lift of 0 m.

TM02

081

8 02

01

7.5"

12.5

9"

7.55

"

9.44"

22.44"4x3/8" Dia.

4.5"

8.56"

Pump type Voltage I1/1[A]

Istart [A]

P2 Net weight [kg][W] [hp]

MQ 3-35 1 x 110-120 V 7.2 12.5 580 0.79 13.0MQ 3-45 1 x 110-120 V 9.2 12.5 680 0.92 13.0MQ 3-25 1 x 220-240 V 2.2 8.6 400 0.55 13.0MQ 3-35 1 x 220-240 V 3.7 8.6 580 0.79 13.0MQ 3-45 1 x 220-240 V 4.5 8.6 680 0.92 13.0

Page 7: MQ – DATA BOOKLET - · PDF file4 General data MQ Control panel Operation of the MQ pump is effected entirely via the control panel. Fig. 1 MQ control panel Installation Self-cooling

7

Page 8: MQ – DATA BOOKLET - · PDF file4 General data MQ Control panel Operation of the MQ pump is effected entirely via the control panel. Fig. 1 MQ control panel Installation Self-cooling

www.grundfos.com

Subject to alterations.

V7164095 0607 GBRepl. V7164095 0104

Being responsible is our foundationThinking ahead makes it possible

Innovation is the essence

GRUNDFOS A/S . DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00